• Title/Summary/Keyword: water quality model test

Search Result 131, Processing Time 0.028 seconds

A Water Model Study on Molten Metal Flow in Die Cavity of Die Casting (다이캐스트 주물의 금형공동내에서 탕류에 관한 수모델적 연구)

  • Kim, Myung-Jae;Choi, Hee-Ho;Cho, Nam-Don
    • Journal of Korea Foundry Society
    • /
    • v.14 no.6
    • /
    • pp.576-589
    • /
    • 1994
  • Water modeling experiments and computer simulation for the predictions of defects of die castings are very important to produce high quality castings with less cost. The relation between the variable air vent system and the characteristics of the fluid flow in the die cavity is studied by using water modeling tests, which give ideas on reasonable designing of die cavity, vent arrangement and gating system. In order to test the water modeling, injection is done by using water containing NaCl. Flow behaviors in cavities are visualized by high speed camera and video tape recorder, and local filling time is measured with electrode sensors. Special attention is paid to the configuration of die cavity. Simulated results by computer are examined and compared with the results of water modeling experiments. There are close correlations between the simulated results and water modeling ones.

  • PDF

A Study on Fuzzy Control Method of Energy Saving for Activated Sludge Process in Sewage Treatment Plant (하수처리 활성오니공정의 에너지 절감을 위한 퍼지 제어 방법에 관한 연구)

  • Nahm, Eui-Seok
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.67 no.11
    • /
    • pp.1477-1485
    • /
    • 2018
  • There are two major issues for activated sludge process in sewage treatment plant. One is how to make sewage be more clean and the other is the energy saving in sewage treatment process. The major monitoring sewage qualities are chemical oxygen demand, phosphorus, nitrogen, suspended solid in effluent. These are transmitted to the national TMS(Telemetry Monitoring System) at every hour. If these exceed the environmental standard, the environmental charges imposed. So, these water qualities are to be controlled below the environmental standard in operation of sewage treatment plant. And recently, the energy saving is also important in process operation. Over 50% energy is consumed in blowers and motors for injection oxygen into aeration tank. So, with the water qualities to be controlled below the environmental standard, the energy saving also is to be accomplished for efficient plant management. Almost researches are aimed to control water quality without considering energy saving. AI techniques have been used for control water quality. AI modeling simulator provided the optimal control inputs(blower speed, waste sludge, return sludge) for control water quality. Blower speed is the main control input for activated sludge process. To make sewage be more clean, the excessive blower speed is supplied, but water quality is not better than the previous. In results, non necessary energy is consumed. In this paper we propose a new method that the energy saving also is to be accomplished with the water qualities to be controlled below the environmental standard for efficient plant management. Water qualities in only aeration tank are used the inputs of fuzzy models. Outputs of these models are chemical oxygen demand, phosphorus, nitrogen, suspended solid in effluent and have the environmental standards. In test, we found this method could save 10% energy than the previous methods.

A Study on the Coagulant Dosing Control Based on Neural Network and Streaming Current Detector for Water Treatment Plant (신경망과 유동전류계를 이용한 정수장 응집제 주입제어에 관한 연구)

  • Kim, Ki-Pyung;Kim, Yong-Yeol;Yoo, Jun;Kang, Yi-Seok
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.10 no.6
    • /
    • pp.551-556
    • /
    • 2004
  • Coagulation process is one of the most important processes in water treatment procedures for stable and economical operation, and coagulant dosing of this process for most plants is generally determined by the jar test. However, this method does not only take a long time to analyze and get the result but also has difficulties in applying to automatic control. This paper shows the feasibility of applying neural network to control the coagulant dosing automatically in water treatment plant. To be specific, the predicted results of the neural network model is shown to be similar to that of jar test. The input variables for learning the neural network are turbidity, water temperature, pH, and alkalinity. Combining the neural network and SCD(Streaming Current Detector) for feedforward and feedback control of injecting coagulant, a rapid change of the raw water quality can be accommodated.

Airborne Hyperspectral Imagery availability to estimate inland water quality parameter (수질 매개변수 추정에 있어서 항공 초분광영상의 가용성 고찰)

  • Kim, Tae-Woo;Shin, Han-Sup;Suh, Yong-Cheol
    • Korean Journal of Remote Sensing
    • /
    • v.30 no.1
    • /
    • pp.61-73
    • /
    • 2014
  • This study reviewed an application of water quality estimation using an Airborne Hyperspectral Imagery (A-HSI) and tested a part of Han River water quality (especially suspended solid) estimation with available in-situ data. The estimation of water quality was processed two methods. One is using observation data as downwelling radiance to water surface and as scattering and reflectance into water body. Other is linear regression analysis with water quality in-situ measurement and upwelling data as at-sensor radiance (or reflectance). Both methods drive meaningful results of RS estimation. However it has more effects on the auxiliary dataset as water quality in-situ measurement and water body scattering measurement. The test processed a part of Han River located Paldang-dam downstream. We applied linear regression analysis with AISA eagle hyperspectral sensor data and water quality measurement in-situ data. The result of linear regression for a meaningful band combination shows $-24.847+0.013L_{560}$ as 560 nm in radiance (L) with 0.985 R-square. To comparison with Multispectral Imagery (MSI) case, we make simulated Landsat TM by spectral resampling. The regression using MSI shows -55.932 + 33.881 (TM1/TM3) as radiance with 0.968 R-square. Suspended Solid (SS) concentration was about 3.75 mg/l at in-situ data and estimated SS concentration by A-HIS was about 3.65 mg/l, and about 5.85mg/l with MSI with same location. It shows overestimation trends case of estimating using MSI. In order to upgrade value for practical use and to estimate more precisely, it needs that minimizing sun glint effect into whole image, constructing elaborate flight plan considering solar altitude angle, and making good pre-processing and calibration system. We found some limitations and restrictions such as precise atmospheric correction, sample count of water quality measurement, retrieve spectral bands into A-HSI, adequate linear regression model selection, and quantitative calibration/validation method through the literature review and test adopted general methods.

Modeling of Particle Removal in the Coarse Media of Direct Horizontal-Flow Roughing Filtration (Direct Horizontal-Flow Roughing Filtration의 조립 여상에서의 입자 제거 모델링)

  • Ahn, Hyo-Won;Park, No-Suk;Lee, Sun-Ju;Lee, Kyung-Hyuk;Wang, Chang-Keun
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.19 no.3
    • /
    • pp.338-347
    • /
    • 2005
  • Horizontal-Flow Roughing Filtration (HRF) is one of altemative pretreatment methods e.g. prior to Slow Sand Filtration (SSF). However, some of its limitations are that the effluent quality drops drastically at higher turbidity (>200 NTU) and at higher filtration rate (>1 m/h). To overcome these drawbacks, we suggested Direct Horizontal-Flow Roughing Filtration (DHRF), which is a modified system of Horizontal-Flow Roughing (HRF) by addition of low dose of coagulant prior to filtration. In this study to optimize the DHRF configuration, a conceptual and mathematical model for the coarse compartment has been developed in analogy with multi-plate settlers. Data from simple column settling test can be used in the model to predict the filter performance. Furthermore, the model developed herein has been validated by successive experiments carried out. The conventional column settling test has been found to be an handy and useful to predict the performance of DHRF for different raw water characteristics (e.g. coagulated or uncoagulated water, different presence of organic matter, etc.) and different inital process conditions (e.g. coagulant dose, mixing time and intensity, etc.). An optimum filter design for the coarse compartment (grain size 20mm) has been found to be of 3 m/h filtration rate with filter length of 4-4.5 m.

Stability Test Using Froude Scaling Method of Emergency Flotation System for Helicopter (Froude Scaling 기법을 적용한 헬기 비상부주 장비 해수면 안정성 입증 시험)

  • Chang, In-Ki;Ryu, Bo-Seong;Kim, Joung-Hun;Kim, Young-Jin
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.43 no.12
    • /
    • pp.1089-1096
    • /
    • 2015
  • A marine helicopter should remain sufficiently upright to permit safe evacuation of all personnel with a flotation system. And the rule requires that after ditching in water, the adequate flotation time will allow the occupants to leave the rotorcraft. To this end, stability test of the emergency flotation system for Korean marine helicopter was performed by using "Froude scaling method" in water tank. Test configuration and conditions were determined in consideration of the helicopter loading condition and related specifications. Test results meet the stability requirements at sea state code 4 and sea state code 2 with puncture conditions.

Effects of Turbulent Mixing and Void Drift Models on the Predictions of COBRA-IV-I

  • Yoo, Yeon-Jong;Hwang, Dae-Hyun;Nahm, Kee-Yil;Sohn, Dong-Seong
    • Proceedings of the Korean Nuclear Society Conference
    • /
    • 1996.05b
    • /
    • pp.284-289
    • /
    • 1996
  • The predictions of the COBRA-IV-I code with the modified turbulent mixing and void drift models have been compared with the diabatic two-phase flow data on equilibrium quality. The turbulent mixing model based on an equal mass exchange of the existing COBRA-IV-I code has been modified to that based on an equal volume exchange between adjacent subchannels, and a void drift model has been newly incorporated in the code. To evaluate the performance of the equal volume exchange turbulent mixing model and the effects of the void drift model, the diabatic steam-water two-phase flow data obtained for the 9-rod bundle test under the typical operating conditions of the boiling water reactor(BWR) conducted by the General Electric (GE) were analyzed by the modified COBRA-IV-I code. The analysis indicates that the equal volume exchange turbulent mixing model with void drift predicts the observed two-phase flow data trends better than the equal mass exchange model, and to predict the correct data trends a more physically based void drift model need to be developed.

  • PDF

Estimating the Attribute Values of 4 Major River Estuaries in Korea -Focusing on Testing for the IIA Assumption in MNL Model and the Alternative Models- (4대강 하구의 속성 가치 추정 -다항로짓모형에서 IIA가정의 검토와 대안 모형을 중심으로-)

  • Shin, Youngchul
    • Environmental and Resource Economics Review
    • /
    • v.22 no.3
    • /
    • pp.521-545
    • /
    • 2013
  • This study applied choice experiment(CE) method(which is included in the stated preference method) to estimate values of some important attributes(i.e. type of estuary, water quality of river in estuary, water quality of sea in estuary, biodiversity level of estuary) of 4 major river(Hangang, Guemgang, Yeongsangang, Nakdonggang) estuaries in Korea. Although the multinomial logit model(MNL) is generally applied to analyse the CE data, testing for IIA assumption with the Hausman and McFadden test in MNL model shows that the IIA assumption in our data is rejected. Therefore, the heteroscedastic extreme value model(HEV) and the multinomial probit model(MNP) which are not based on the IIA assumption are used to analyse our CE data. As results, the coefficients and the elicited economic values of MNL model are seriously distorted if the IIA assumption is not satisfied in MNL model. The estimation results of MNP model show that the economic values are elicited as 352.3 billion won(95% C.I. 261.1 - 477.8 billion won) for natural estuary, 411.5 billion won(95% C.I. 338.5 - 525.5 billion won) for one grade improvement of river water quality in estuary, 358.9 billion won(95% C.I. 292.5 - 457.0 billion won) for one grade improvement of sea water quality in estuary, and 151.9 billion won(95% C.I. 99.0 - 218.6 billion won) for one grade improvement of biodiversity level of estuary. Therefore, the value of estuary is reached to 2,197.0 billion won(95% C.I. 1,721.0 - 2,879.9 billion won) if any natural estuary in 4 major rivers has good water quality of river in estuary(i.e. 2nd grade), good water quality of sea in estuary(i.e. 1st grade), and good biodiversity level of estuary.

Water Quality Level Model Using the Discriminant Analysis for the Small Streams of Rural Area in the Han River Watersheds (판별분석을 이용한 한강권역 농업용 하천수의 수질등급모형)

  • Choi, Chul-Mann;Lee, Jong-Sik;Cho, Nam-Jun;Ryu, Hui-Yong;Park, Seong-Jin;Kim, Jin-Ho;Yun, Sun-Gang;Lee, Jeong-Taek
    • Korean Journal of Environmental Agriculture
    • /
    • v.27 no.2
    • /
    • pp.105-110
    • /
    • 2008
  • The main purpose of this work is the development of water quality level model using the data such as DO, EC, BOD, $COD_{Cr},\;NH_3-N,\;NO_3-N,\;PO_4-P$, T-N, T-P, and SS in 88 agricultural streams of the Han river watersheds. To grant water quality level for each parameters, it divided into 20% respectively in the order of water quality level. On the basis of the lowest water quality level, water quality of streams was assigned. As the result, number of stream corresponding to Level Ⅰ was 0, Level II was 1 stream, Level III was 3 streams, Level IV was 22 streams, and Level V was 62 streams. By standardized canonical discriminant function coefficient, $NO_3-N$ was the highest in 0.427 at the discriminant power. According to discriminant function for water quality level, it was equal to $-4.648+3.246{\times}[NO_3-N],\;-5.084+3.456{\times}[NO_3-N],\;-4.298+3.067{\times}[NO_3-N],\;and\;-7.369+4.396{\times}[NO_3-N]$ from Level II to Level V, respectively. As a result of test at real data of the Han river watersheds in 2007, the suitability of water quality level model was high to 88.4%.

Development study of ground water management system making use of GIS ( Well analysis program, connection program of ground water modeling ) (GIS를 이용한 지하수관리시스템 개발 연구 (관정분석 프로그램, 지하수모델링 연계프로그램))

  • 이병호;김양빈;설민구;송양권;송무영
    • Proceedings of the KSEG Conference
    • /
    • 2002.04a
    • /
    • pp.235-248
    • /
    • 2002
  • Ground water development skill growth and life circumstances improvement increase ground water use. So managerial difficulties and various problems about ground water occur. Poor ground water management organization, lack of management person, thoughtless development add ground water pollution and lack of water volume. And local excessive developments or abandoned well occur. This paper presents ground water management system model making use of GIS and helps effective management by realizing necessary analysis functions in ground water management system and ground management methods. Local information of ground water recorded and development data, site examination data made D/B. And linearment analysis data making use of a satellite image data, hydraulic test data, the quality of water examination data, these local characteristic values made out thematic maps and making use of these data can form elementary data of ground water modeling It makes easy to understand environmental development conditions and pollution source conditions about new ground water development location, linearment growth, DRASTIC, the quality of water examination. Ground water management system making use of these functions can choose right location of ground water.

  • PDF