• 제목/요약/키워드: water purification system

검색결과 306건 처리시간 0.036초

Microbial Activity of Gravel Intertidal Zone for Purification of Polluted Near Shore Water

  • Song, Young-Chae;Gu, Ja-Hwan;Park, In-Seok;Yoo, Jong-Su
    • 한국항해항만학회지
    • /
    • 제28권2호
    • /
    • pp.155-159
    • /
    • 2004
  • Microbial activity of biofilm formed on the surface of gravels from intertidal zone was estimated using an aerobic respirometer system, and compared with that of suspended marine microorganisms contained in a near shore water, The maximum oxygen uptake rate of the suspended marine microorganisms was 0.15mg$O_2$/L/hr, indicating the potential of purification of polluted near shore water. For the gravels from the intertidal zone, the maximum uptake rate of oxygen was affected by the vertical positions, but their gross value was 0.77mg $O_2$/L/hr, which was around 5.1 times higher than the purification potential of polluted near shore water by the microorganisms contained in the near shore water. The nitrogen removed by the gravels from the intertidal zone and the marine microorganisms was about 1/20-1/39 times of the total consumption of oxygen, which was similar to that of the phosphate. The gravel intertidal zone contained lots of particulate organics, over than that in the near shore water, and this was confirmed from the large difference between total oxygen consumption and the removed soluble COD in the microbial activity test. This indicates that the gravel intertidal zone plays an important role in controlling the non-point source pollutants from land, as well as self-purification of polluted near shore water by trapping and degrading the particulate organics.

통합형 오일 정제 시스템의 개발 (Development of an Integrated Oil Purification System)

  • 홍성호;이경희;정남화
    • Tribology and Lubricants
    • /
    • 제38권4호
    • /
    • pp.121-127
    • /
    • 2022
  • This study presents the development of an integrated oil purification system consisting of moisture removal, oil flushing, and oil filtering devices. In this system, the oil flushing device is combined with a micro-bubble generator. Oil purification is necessary for ensuring the high performance of the lubricant through the efficient removal of contaminants and thus enables good maintenance of mechanical systems. The developed purification system removes moisture, varnish, and solid particles. Moreover, during oil purification, the oil flushing device separates foreign materials and contaminants remaining in the lubricating oil piping or mechanical systems. The microbubble generator, which is combined with the oil flushing device, can separate harmful contaminants, such as sludge, wear particles, and rust, from piping or lubrication systems through the cavitation effect. Moisture is removed using a double high-vacuum chamber, while sludge and varnish are removed via electro-absorption using a high-voltage generator. Additionally, the total maintenance cost of the system is reduced through the use of domestically fabricated cartridge filters composed of glass fiber and cellulose. The heater, which maintains the temperature of the lubricant at 60℃, can process 41,000 L of lubricant simultaneously. Multiple tests confirmed that the proposed integrated purification system exhibits good performance in oil flushing and removal of water and varnish.

퍼지제어를 통한 오수-합병정화조의 오니 측정 및 제어시스템에 관한 연구 (The Development using Fuzzy Control of sludge amount inspection and discharge materials of outlet water and affiliated water-purification tank)

  • 박주식;박윤규;강경식
    • 대한안전경영과학회지
    • /
    • 제3권4호
    • /
    • pp.53-63
    • /
    • 2001
  • The individual rotten water purification tank recently discharges wastewater and sewage through the outlet without purification ability. The outlet water and affiliated water purification tank with microorganism cultivator tank cultivates microorganism and then drops the value BOD, COD of sewage and discharges the quality of water into the outlet. The blower and water pump operating continuously prompts the waste of energy and deterioration of equipment. Each room of deposition tank, foaming tank, microorganism cultivator tank is equipment with the sludge detection senses so it can detect the density of each room. The power-drive plant of the blower and water pump which are the system cultivating the microorganism must be made as fuzzy controlization (If the sludge amount of each room become higher, the rate of operation of blower and water pump must heighten, on the contrary, in case of row sludge amount, the total handling amount and microorganism handling amount of each room of control. Tank reducing the rate of operation must be DB. At present, the blower amount in proportion to the sludge and oxyzen demanding amount has to control. Each room mus be checked outlet level of the outlet, also each room must flow backward discharge materials, and must operate feed-back control until we want to be come as a below value of BOD/COD(10PPM ; KS).

  • PDF

정수장에서의 에너지 관리 및 복합센서 검증을 위한 AI 기반 복합센서 사전검증시스템 구축 (Establishment of AI-based composite sensor pre-verification system for energy management and composite sensor verification in water purification plant)

  • 김국일;성민석;안상병;홍성택
    • 한국정보통신학회:학술대회논문집
    • /
    • 한국정보통신학회 2022년도 추계학술대회
    • /
    • pp.43-46
    • /
    • 2022
  • 수용가에서 사용되는 수돗물의 패턴과 양을 정확하게 예측하여 필요한 만큼의 수돗물을 펌프를 이용하여 배수지로 전달하여 저장하고, 필요한 유량이 최소의 전기에너지를 이용하여 적기에 공급되어야 정수장의 최적화 운영을 할 수 있다. 본 논문에서는 수돗물 생산·공급의 안정성을 확보하기 위하여 AI 기반 복합센서를 실증지인 정수장에 적용하기 전에 사전검증할 수 있는 시스템을 구축하여 복합센서별 사전검증 모델을 통해 보완 사항을 도출하고, 제작 과정에 피드백하여 복합 센서 데이터의 품질 및 동작 안정성을 향상시키고자 하였다.

  • PDF

고 플럭스 MF막의 정수처리 실용화에 관한 연구 (Application of water control by high fiux MF membrane)

  • 황상용
    • 환경위생공학
    • /
    • 제23권2호
    • /
    • pp.55-63
    • /
    • 2008
  • All over the world, the existing process of water purification needs more flocculants and chlorine due to a gradual decline in the quality of source water. Therefore, the problem of the remaining aluminium and DBPs in purified water is on the rise. To solve this problem, the process of membrane filter has recently come into the spotight. This study reaches the following conclusions concerning TMP variation in order to solve the dropping of flux throgh a membrane filter when operating a membrane filter system in the process of water purification. 1. In case that a cohesion-precipitation process was introduced to pre-treatment of a membrane filter, initial TMP was very satisfactory(0.27kg/cm) in producing the constantly safe quality of water, $0.04{\sim}0.1$(mean 0.05) NTU by pouring 2mg/l of PACI(10% $Al_2O_3$) used for the existing process of water purification in high-density turbidity at a dry or flood season and at occurrence of high algae. 2. As flux increased at 0.5m/day.m, TMP increased 0.05 kgf/cm. 3. As filtering, operation mode of PVDF MF membrane filtering was 48 minutes and 1 cycle of back washing was 42 minutes, flux was increased 1.5m/day.m and TMP increased $0.25{\sim}0.27kgf/cm$. Without back washing, TMP increased 0.03 kgf/cm per a cycle.

중공사 정밀여과막을 이용한 상수처리용 일체형 시스템 개발 (Submerged Type Water Purification System using Hollow Fiber Microfiltration Membrane)

  • 정규영;김형수;임종성
    • 한국수자원학회논문집
    • /
    • 제32권3호
    • /
    • pp.311-319
    • /
    • 1999
  • 기존의 정수처리 공정인 응집 ·침전·모래여과를 단일 공정인 막분리 공정으로 대체하기 위한 중공사 정밀여과막의 적용 가능성을 검토하였다. 실험은 우선 실험실 규모의 실험에서 여러 가지 운전인자에 대한 수질의 안정성 및 장기 운전 가능성을 검토하였고, 여기에서 최적 운전인자로 얻어진 투과플럭스 0.03m/h, 10분 여과, 2분 정지 (30초간 air scrubbing 세정 포함)의 조건으로 20m3/일 규모의 Pilot Plant를 1년 이상 운전하여 안정성을 검증하는 방법으로 수행되었다. 탁도, SS등 막 투과수 수질은 전 실험 기간 동안 탁월한 제거효율을 나타내었다. 따라서 정수처리 공정에의 중공사 정밀여과막을 이용한 막분리 공정은 적용 가능하다고 판단된다.

  • PDF

상수처리시스템 응집제 주입공정 퍼지 모델링과 제어 (Fuzzy modeling and control for coagulant dosing process in water purification system)

  • 이수범;남의석;이봉국
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 1996년도 한국자동제어학술회의논문집(국내학술편); 포항공과대학교, 포항; 24-26 Oct. 1996
    • /
    • pp.282-285
    • /
    • 1996
  • In the water purification plant, the raw water is promptly purified by injecting chemicals. The amount of chemicals is directly related to water quality such as turbidity, temperature, pH and alkalinity. At present, however, the process of chemical reaction to the turbidity has not been clarified as yet. Since the process of coagulant dosage has no feedback signal, the amount of chemical can not be calculated from water quality data which were sensed from the plant. Accordingly, it has to be judged and determined by Jar-Test data which were made by skilled operators. In this paper, it is concerned to model and control the coagulant dosing process using jar-test results in order to predict optimum dosage of coagulant, PAC(Polymerized Aluminium Chloride). The considering relations to the reaction of coagulation and flocculation, the five independent variables(turbidity, temperature, pH, Alkalinity of the raw water, PAC feed rate) are selected out and they are put into calculation to develope a neural network model and a fuzzy model for coagulant dosing process in water purification system. These model are utilized to predict optimum coagulant dosage which can minimize the water turbidity in flocculator. The efficacy of the proposed control schemes was examined by the field test.

  • PDF

선형계획법을 이용한 정수장 취수계획 최적화 (Optimization of water intake scheduling based on linear programming)

  • 정기문;이인도;강두선
    • 한국수자원학회논문집
    • /
    • 제52권8호
    • /
    • pp.565-573
    • /
    • 2019
  • 본 연구에서는 지능형 정수장 운영시스템 개발 연구의 일환으로 선형계획법(Linear Programming, LP)을 이용한 정수장 취수계획 최적화 모형을 개발하였다. 개발된 최적화 모형은 원수의 정수처리비용의 최소화를 목적함수로 설정하였으며, 취수 후 정수처리에 소요되는 지연시간과 시간별 전력단가를 고려하여 취수가능량, 예측수요량, 정수지 운영수위 등의 제약조건을 만족하는 최적 취수계획을 제시하였다. 국내 H 정수장을 대상으로 경제적이고 안정적인 정수장 운영을 위해 세 가지 최적화 전략을 적용하고, 그 결과를 경제성과 안정성 측면에서 비교, 분석하였다. 개발 모형은 국내 정수장의 보다 효율적인 취수계획 수립을 위한 의사결정 지원시스템의 형태로 실무에서 활용이 가능할 것으로 기대된다.

CFD를 이용한 펌프확산 및 수리낙차 방식의 혼화공정 흐름 분석 (MIXING PROCESS FLOW ANALYSIS OF PDM AND HYDRAULIC MIXING BASIN SYSTEM USING CFD)

  • 이성우;장세명;조용
    • 한국전산유체공학회지
    • /
    • 제22권1호
    • /
    • pp.1-7
    • /
    • 2017
  • The mixing of water and chemicals is an important process in the water purification plant. In this paper, we compare PDM(pump diffusion mixer) and hydraulic mixer at the basin in the mixing process. The proper flow rates are predicted and compared in both mixers using CFD technique. As a result, the flow rate of purifier chemical liquid should be 5% of that of water for the optimal performance of mixing process. The characteristics of the two mixing methods are compared with each other for strong and weak points on the operation of the purification system, discussed in the view point of CFD simulations.

바이오스톤 볼 수처리 시스템에 의한 오염물질 저감 및 저수지의 수질개선효과 산정 (Estimation of Water Quality Improvement and Reduction of Influent Pollution by Installation of Water Treatment System Filled with Bio-stone Ball)

  • 최선화;김흥섭;정세웅
    • 환경영향평가
    • /
    • 제28권5호
    • /
    • pp.471-482
    • /
    • 2019
  • 본 연구에서는 유기성 오염도가 높은 국내 하천 및 호소의 수질정화를 위해 바이오스톤 볼 담체를 이용한 수처리 기술을 개발하였다. 바이오스톤 볼 수처리기술의 오염물질 제거효율 및 저수지 수질개선효과 등을 평가하기 위하여 경기도 시흥시에 위치한 매화저수지에 실증플랜트를 설치하였다. 바이오스톤 볼 수처리시스템의 오염물질 제거효율은 BOD 70.3%(47.2~97.4%), COD 45.3%(26.1~64.7%), TOC 19.2%(8.5~50.0%), SS 82.8%(73.1~92.7%), Chl-a 80.4%(57.2~91.8%), TN 23.2%(6.4~39.5%), TP 51.8%(-1.1~80.1%)로 나타나 BOD, SS, Chl-a에서 평균 70~80% 이상의 매우 높은 정화효율을 나타내었다. 바이오스톤 볼 수처리시스템을 저수지 평시 유입량 설계기준으로 설치하였을 경우의 유입 오염물질 저감량 및 저수지 수질개선효과를 산정하였다. 저감되는 COD 부하량은 13,658 kg으로 연간 39.2%가 저감되고, TP 부하량은 297 kg으로 연간 16.8%가 저감되는 것으로 나타났다. 저수지의 연간 수질개선효과는 TOC $5.3{\rightarrow}4.5mg/L$(14.5%), COD $7.9{\rightarrow}6.8mg/L$(14.5%), Chl-a $42.3{\rightarrow}37.0mg/m^3$(12.5%), T-P $0.201{\rightarrow}0.150mg/L$(25.1%)가 평균적으로 개선되는 것으로 나타났다. 바이오스톤 볼 수처리시스템은 유기성 오염도가 높은 국내 하천 및 호소의 유입수 오염물질 제거 및 수질정화를 위한 수처리 시설로서 현장적용성이 높을 것으로 판단된다.