• 제목/요약/키워드: water purification system

검색결과 306건 처리시간 0.041초

오수/합병정화조의 배출물 제어시스템 연구 (The control system of sludge amount inspection and discharge materials of outlet water and affiliated water-purification tank)

  • 박주식;김건호;오지영;임총규;강경식
    • 대한안전경영과학회:학술대회논문집
    • /
    • 대한안전경영과학회 2001년도 추계학술대회
    • /
    • pp.193-202
    • /
    • 2001
  • The individual rotten water purification tank recently discharges wastewater and sewage through the outlet without purification ability. The outlet water and affiliated water purification tank with microorganism cultivator tank cultivates microorganism and then drops the value BOD, COD of sewage and discharges the quality of water into the outlet. The blower and water pump operating continuously prompts the waste of energy and deterioration of equipment. Each room of deposition tank, foaming tank, microorganism cultivator tank is equipment with the sludge detection senses so it can detect the density of each room. The power-drive plant of the blower and water pump which ate the system cultivating the microorganism must be made as fuzzy controlization (If the sludge amount of each room become higher, the rate of operation of blower and water pump must heighten, on the contrary, in case of row sludge amount, the total handling amount and microorganism handling amount of each room of control. Tank reducing the rate of operation must be DB. At present, the blower amount in proportion to the sludge and oxygen demanding amount has to control. Each mom must be checked outlet level of the outlet, also each room must flow backward discharge materials, and must operate feed-back control until we want to be come as a below value of BOD/COD(10PPM ; KS).

  • PDF

공공하수처리시설의 총인기준 강화에 따른 비용효과분석 (Analysis of the cost effectiveness according to T-P standard enforcement of public sewage treatment facilities)

  • 정원구;임재명
    • 산업기술연구
    • /
    • 제31권A호
    • /
    • pp.135-145
    • /
    • 2011
  • This study was conducted to analyze the cost effectiveness in line with total phosphorus standard enforcement of public sewage treatment facilities. The additional cost for the total phosphorus removal process was calculated to analyze the cost effectiveness of the advanced water purification process. The analysis results showed that the T-P removal by coagulation sedimentation was more efficient than the advanced water purification facilities in terms of facilities investment cost, and if the coagulation filteration was used for T-P removal, the activated carbon process among the advanced water purification techniques was more efficient in terms of facilities investment cost. In this study, the effects of the T-P removal process that will be additionally introduced according to the tightening of the effluent T-P standard were analyzed within a limit. The actual benefits of improved T-P concentration in the water source will provide diverse values, including the leisure water, environment improvement water, eco-system in the water source and industrial water, in addition to the advanced water purification.

  • PDF

산소용해수와 미생물제재를 이용한 호소 및 폐쇄수역의 정화기술 (Purification Technology in Closed Water like a Reservoir and Pond using Oxygen Solubilized Device and Standardized Microorganism Culture System)

  • 서성녀;김영택;박철휘
    • 한국물환경학회지
    • /
    • 제21권2호
    • /
    • pp.118-124
    • /
    • 2005
  • The oxygen solubilized device(O.S.D) and standardized microorganism culture system is more efficient than physical and chemical purification techniques in closed water. This study was to determine how the O.S.D and standardized culture system is efficient in purification capacity in closed water based on the lab scale and pilot plant. In the batch test, inducing the quantitative results from pilot plant operation condition, removal efficiency of COD and TN were about 48.3% and 35% respectively, while SS and chlorophyll-a were 94.9% and 68.7%. The pilot plant results showed that suspended solid(SS) and chlorophyll-a removal efficiency were 60% and 59% respectively, due to coagulation characteristics by standardized culture. Total nitrogen(TN) and total phosphorus(TP)showed good effect for the purification of target pond water quality from field data. Additionally, released velocity was determined in control condition of $5.31mgPO{_4}^{3-}{\cdot}m^{-2}{\cdot}day^{-1}$ and $2486.8mgCOD{\cdot}m^{-2}{\cdot}day^{-1}$. Otherwise, phosphate and COD reflux in the aeration and microorganism condition was showed $-9.95mgPO{_4}^{3-}{\cdot}m^{-2}{\cdot}day^{-1}$ and $-397.88mgCOD{\cdot}m^{-2}{\cdot}day^{-1}$. This technology is the most effective not only removal of SS and chlorophyll-a but also control of phosphate and COD release which is very important phenomena in evaluating water quality in closed water like a reservoir and pond.

네트워크 통합관리시스템과 보안스위치를 이용한 반송정수장 무선랜 구축사례 (The case study on wireless lan design technique for Bansong purification plant using network integrated management system and security switch)

  • 박은철;최현주
    • 상하수도학회지
    • /
    • 제32권4호
    • /
    • pp.309-315
    • /
    • 2018
  • Currently, the commercialization of the $5^{th}$ Generation (5G) service is becoming more prevalent in domestic communication network technology. This has reduced communication delay time and enabled large-capacity data transmission and video streaming services in real-time. In order to keep pace with these developments, K-water has introduced a smart process control system in water purification plants to monitor the status of the water purification process. However, since wireless networks are based on the public Long Term Evolution (LTE) network, communication delay time remains high, and high-resolution video services are limited. This is because communication networks still have a closed structure due to expense and security issues. Therefore, with 5G in its current form, it is very difficult to accommodate future services without improving the infrastructure of its communication networks. In recognition of these problems, this study implemented the authentication and management function of wireless networks on a wired network management system in the K-water Bansong water purification plant. The results confirmed that wired Local Area Network (LAN) services give a higher security performance than an expensive commercial wireless LAN system. This was achieved by using an Internet Protocol (IP) address management system of wired networks and the packet filtering function of the Layer2 (L2) switch. This study also confirmed that it is possible to create a wireless LAN service that is 3.7 times faster than the existing LTE communication network.

A Field Study for Sustainable Community Empowerment through Appropriate Technology of Water Purification and the Concept of Feces Standard Money in Hatphain Village, Lao PDR

  • Heo, Huijin;Choi, Mi-Jin;Im, Tae Hyug;Cho, Jaeweon
    • 적정기술학회지
    • /
    • 제7권2호
    • /
    • pp.151-161
    • /
    • 2021
  • The application of appropriate technologies in a developing country is an opportunity to introduce green technology which may lead people to imagine a better life. This point is at the intersection of appropriate technology and sustainable development. This research focuses on Hatphain village where there is no clean water, sewage system, or power lines. Two environmental technologies (an unpowered water purification system, Ongdalsaem and an eco-toilet system, BeeVi toilet) were introduced, based on the concepts of the environmental self- sustainable village and feces Standard Money (fSM). We found that the Ongdalsaem was effective in reducing the concentration of nitrogen and lead in the water in Hatphain. The BeeVi water-free toilet was installed, allowing urine and feces to be separated and used as compost. We strived to spread ideas of sustainability using new eco-circulation experiences and encouraging learning about environmental technology through practical and playing facilities that residents managed themselves.

저류지 생태공원 설계모형 개발에 관한 연구 (A Study on the Development of Design Model of Ecological Park as Stormwater Storage Facilities)

  • 변우일
    • 한국환경복원기술학회지
    • /
    • 제9권3호
    • /
    • pp.1-16
    • /
    • 2006
  • The purpose of this study is to develop design model of ecological park as stormwater storage facilities. The results are as follows : First, the design model of ecological park as stormwater storage facilities consider ecological and landscape characteristics such as high efficiency of land use, function as disaster prevention, ecological water purification, formation of habitat for flora and fauna. Second, this study demonstrates two types of plane structure and eight types of designed section. They can be combined and designed depending on conditions of each site. The facilities of stormwater storage conduct disaster prevention system and ecological park. Retention pond in stormwater storage facilities for ecological park also should be made for ecological restoration in the site. Third, the ecological park provide the basis for ecological network from in-site to out-site. Therefore its conservation and restoration plan consider the ecosystems of the site. Fourth, the most important factor for maintenance and management for retention pond is keeping water quality. Sustainable Structured wetland Biotop system is suggested for ecological water purification system in the retention pond which is one of the constructed wetland system using multi-celled aquatic plant and pond. This system can also provide habitat for animals and plants, water friendly park for men, and beautiful landscape.

비접촉식 자외선램프를 이용한 살균/정화 수도꼭지 (A Water Tap Equipped with a Sterlization/Purification System of Non-contact UV-lamp)

  • 민경원;원종헌;이현철;한동열
    • 산업기술연구
    • /
    • 제27권B호
    • /
    • pp.3-7
    • /
    • 2007
  • Ultraviolet light(UV-C, wavelength: 200~280nm) is employed profitably for sterilizing drinking water. For most water serving apparatus such as a water purifier, a water cooler and heater, a coffee vending machine and etc., pre-sterilized water may be contaminated secondarily with bacillary inhabitation in a container before serving. In consideration of this problem, a household water tap which is equipped with a sterilization/Purification device in combination with non-contact UV-lamp, was designed to sterilize and purify water at the last outlet just before serving. Hopefully this simple but creative item may be commercialized for household and public use.

  • PDF

산소용해수를 이용한 호소 저질 및 수질개선에 관한 실험적 연구 (An Experimental Study on the Pond Sediment and Water Quality Purification using Oxygen Solubilization Device(OSD) System)

  • 김영택;배윤선;노은경;박철휘;이연구
    • 상하수도학회지
    • /
    • 제20권1호
    • /
    • pp.94-103
    • /
    • 2006
  • The pollution in closing water can be caused by not only artificial factor like sewage but also natural factor like elution from sediment. In this study we analyzed Sediment Oxygen Demand (SOD) for verification of sediment purification effect and sediment elution experiment as well as general items like COD, TN, TP, SS to complement and assess the effect of sediment and water quality. The experiment result showed that the release rate of OSD system were 4 times and 3 times as large as control for P and Fe respectively. SOD for operated OSD system and control were $12.18gO_2{\cdot}m^{-2}{\cdot}d^{-1}$ and $47.95gO_2{\cdot}m^{-2}{\cdot}d^{-1}$. From water qualities analyzed by COD, TN, TP, SS, chlorophyll-a, the removal efficiency increase of TN, TP, chlorophyll-a and COD were about 10~20%, 40~50% and 10% respectively. In conclusion, OSD can contribute to improvement of both the waterbody and the sediment environment effectively.

Microbial Activity of Gravel Intertidal Zone for Purification of Polluted Near Shore Water

  • Song, Young-Chae;Gu, Ja-Hwan;Park, In-Seok;Yoo, Jong-Su
    • 한국항해항만학회:학술대회논문집
    • /
    • 한국항해항만학회 2004년도 춘계학술대회 논문집
    • /
    • pp.233-239
    • /
    • 2004
  • Microbial activity of biofilm formed on the surface of gravels from intertidal zone was estimated using an aerobic respirometer system, and compared with that of suspended marine microorganisms contained in a near shore water. The maximum oxygen uptake rate of the suspended marine microorganisms was 0.15mg O$_2$/L/hr, indicating the potential of purification of polluted near shore water. For the gravels from the intertidal zone, the maximum uptake rate of oxygen was affected by the vertical positions, but their gross value was 0.77mg O$_2$/L/hr, which was around 5.1 times higher than the purification potential of polluted near shore water by the microorganisms contained in the near shore water. The nitrogen removed by the gravels from the intertidal zone and the marine microorganisms was about 1/20-1/39 times of the total consumption of oxygen, which was similar to that of the phosphate. The gravel intertidal zone contained lots of particulate organics, over than that in the near shore water, and this was confirmed from the large difference between total oxygen consumption and the removed soluble COD in the microbial activity test. This indicates that the gravel intertidal zone plays an important role in controlling the non-point source pollutants from land, as well as self-purification of polluted near shore water by trapping and degrading the particulate organics.

  • PDF