• 제목/요약/키워드: water pumping speed

검색결과 23건 처리시간 0.021초

동력경운기(動力耕耘機) 기관(機関)의 효율적(效率的) 이용(利用)에 관한 연구(硏究) (A Study on Efficient Utilization of Power-Tiller Engines)

  • 류관희;박금주
    • Journal of Biosystems Engineering
    • /
    • 제9권2호
    • /
    • pp.1-7
    • /
    • 1984
  • The engines mounted on power-tillers are used as power source in various kinds of works such as plowing, harrowing, transporting, spraying, water pumping and threshing, etc. But the engines have not been used effectively from a standpoint of fuel consumption because of lack of proper power transmission system and lack of understanding of fuel consumption characteristics of the engines. Therefore, this study was attempted to establish proper power transmission system between the power-tiller engines and various implements. In order to accomplish the above objective, firstly, power requirement and pulley sizes for various implements, which are driven by the power-tiller engines, were investigated to find out whether the power transmission system is proper. Secondly, partload variable engine-speed test was conducted for 3 different sizes of diesel engines to measure to specific fuel consumption. Thirdly, the present power transmission systems were analyzed in terms of specific fuel consumption, and proper power transmission systems were suggested for various implements. The results of this study are summarized as follows: 1. Power requirement for each fixed-type implement of power-tiller varied from 1.5 ps to 11 ps according to its type and operating conditions, but generally in the range of 2.5 ps to 7 ps. 2. Each power tiller and implement were equipped with only one size of pully with few exeptions. With the present power transmission systems, the engines can't be utilized effectively in terms of fuel economy. The pulley size of engine or implement should be diversified to provide the optimum engine speed for different implements. 3. For a diesel eninge with the rated power output of 6 ps, the optimum engine speed to minimize specific fuel consumption was 2200 rpm for the power reguirement in the range of 6 ps or more, 1700 rpm in the range of 4 to 6 ps, and 1200 rpm in the range of 4 ps or less. 4. For a diesel engine with the rated power output of 8 ps, the optimum engine speed was 2200 rpm for the power requirement in the range of 7 ps or more, 1700 rpm in the range of 4.8 to 7 ps, and 1200 rpm in the range of 4.8 ps or less. 5. For a diesel engine with the rated power output of 10 ps, the optimum engine speed was 2200 rpm for the power requirement in the range of 8.4 ps or more, 1700 rpm in the range of 5.4 ps to 8.4 ps, and 1200 rpm in thr range of 5.4 ps or less. 6. Provided the existing implements are dirven by 8 ps diesel engines, the optimum size of engine pulley should be larger than 120mm for the works of requiring less than 4 ps and 90-110mm for the works requiring 4.5-6.5 ps in order to minimize fuel consumption.

  • PDF

진공펌프 물 배기속도 측정 설비 구축

  • 이동주;박종윤;인상렬
    • 한국진공학회:학술대회논문집
    • /
    • 한국진공학회 2016년도 제50회 동계 정기학술대회 초록집
    • /
    • pp.109.2-109.2
    • /
    • 2016
  • 현민지브이티(Genesis)는 중소기업청 중소기업개발지원사업의 일환으로 진행된 2014년도 구매조건부 신제품 개발사업에 선정되어 '극저온 G-M냉동기를 이용한 대용량 Cold Trap개발'과제를 수행하면서 32인치 급으로 수분에 대해서 30,000[L/s] 이상의 배기속도를 가지는 대형 CWP를 개발하고 있다. 1차년도(2015년) 목표는 80K에서 200W급 단단 G-M극저온 냉동기를 개발하는 것이고, 2차년도(2016년) 목표는 이를 장착하여 30,000[L/s]의 물 배기속도 능력을 갖춘 32인치(800mm)급 직부형(appendage) CWP를 개발하는 것이다. 여기에서 가장 큰 문제점은 CWP 시스템의 물 배기속도를 실제로 측정하는 것이다. 왜냐하면 지금까지는 물(H2O)이 가진 독특한 물리적 특성으로 인해 배기속도 측정에 많은 어려움이 있어 이론적으로 계산한 값을 사용해 왔다. (심지어 크라이오 펌프 제조사 조차도 실험하지 않고 이론적인 계산 값을 일반적으로 사용한다.) 그러나 최근 본 과제 외에 물 배기속도 측정에 관한 요구사례와 일부 크라이오 펌프 제조사에서 수행하고 있다는 보고가 있는 바, 실제 물배기속도 시스템을 구축하여 이론과 실제 사이의 차이와 측정의 어려움 등에 관해 규명하고자 하였다. 물 배기속도 측정 방법은 크게 2가지로 나눌 수 있다. 첫째, 시스템으로 흘리는 물의 양을 Liquid MFC를 이용하여 먼저 측정한 후 Vaporizer로 보내어 기화 시키며 배기속도를 측정하는 방법. 둘째, 물을 Vaporizer로 먼저 기화시킨 후에 High Temp. MFM으로 기체 유량을 측정하며 배기속도를 측정하는 방법이 그것이다. 이에 국내 최초로 두 가지 방법 모두를 사용하여 표준화 된 물 배기속도 측정 설비를 구축하였고, 20인치(500mm) 크라이오 펌프와 인라인(inline)형 CWP 모델에 대한 물 배기속도 측정을 성공적으로 완료할 수 있었다. 향후 본 시험 방법과 결과를 토대로 32인치(800mm) 직부형 CWP 모델에 대한 물 배기속도 측정시험을 수행하고자 한다.

  • PDF

고주파 인가시의 KSTAR ICRF 안테나의 진공특성 (Vacuum Characteristics of KSTAR ICRF Antenna during RF Operation)

  • 배영덕;곽종구;홍봉근
    • 한국진공학회지
    • /
    • 제15권3호
    • /
    • pp.314-324
    • /
    • 2006
  • KSTAR ICRF 안테나의 진공특성을 실험적으로 조사하였다. 제작된 안테나를 총 유효배기속도 1015 l/s의 진공펌프가 장착된 시험용 진공용기에 설치하였으며, 고주파 시험하기 전에 시간에 따른 압력 변화, 총기체 부하, 도달 진공도 등을 측정하였다. 낮은 출력의 고주파를 반복적으로 인가함으로서 세정 효과를 확인하였다. 안테나에 고주파를 인가하여 시험하는 동안 진공도 변화를 측정하였으며, 압력 상승에 의해 방전이 유발되는 한계 압력을 조사하였다. 본 안테나의 경우 고주파 인가 중에 진공용기의 압력이 $10^{-4}$ mbar 이상이 되면 방전이 일어났다. 장펄스 시험에서 안테나의 온도와 시험용 진공용기의 압력을 측정하여 안테나를 냉각하지 않은 상태에서 운전이 가능한 전압을 조사하였으며, 냉각했을 때의 결과와 비교하였다.