• 제목/요약/키워드: water pressure test

검색결과 1,284건 처리시간 0.027초

수명배수공법에 있어서 부압의 영향에 관한 실험적 연구 (The Effects of Negative Pressure on Horizontal Drain Method)

  • 김정기;김지용;정승용;김수삼
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2001년도 봄 학술발표회 논문집
    • /
    • pp.551-558
    • /
    • 2001
  • The horizontal drain method is one of methods improving reclamation ground. This method reduces consolidation time by using drained installed horizontally, and negative pressure is applied on end of these drains by vacuum pump. But, effective negative pressure still wasn't evaluated in applying this method to reclamation ground. To estimate optimum negative pressure, soil box test that make a model the in-situ by installing horizontal drains in the center is performed pressing different vacuum pressure In the laboratory, and the variations in settlement and volume of drained water through the drains during consolidation process were measured. Also, water content with distance from drain and with depth is measured after the test.

  • PDF

삽입된 광섬유 브래그 격자 센서를 이용한 필라멘트 와인딩된 복합재료 압력탱크의 내부 변형률 모니터링 (Internal Strain Monitoring of Filament Wound Pressure Tanks using Embedded Fiber Bragg Grating Sensors)

  • 김철웅;박상욱;박상오;김천곤;강동훈
    • 한국복합재료학회:학술대회논문집
    • /
    • 한국복합재료학회 2005년도 춘계학술발표대회 논문집
    • /
    • pp.17-20
    • /
    • 2005
  • In-situ structural health monitoring of filament wound pressure tanks were conducted during water-pressurizing test using embedded fiber Bragg grating (FBG) sensors. We need to monitor inner strains during working in order to verify the health condition of pressure tanks more accurately because finite element analyses on filament wound pressure tanks usually show large differences between inner and outer strains. Fiber optic sensors, especially FBG sensors can be easily embedded into the composite structures contrary to conventional electric strain gages (ESGs). In addition, many FBG sensors can be multiplexed in single optical fiber using wavelength division multiplexing (WDM) techniques. We fabricated a standard testing and evaluation bottle (STEB) with embedded FBG sensors and performed a water-pressurizing test. In order to increase the survivability of embedded FBG sensors, we suggested a revised fabrication process for embedding FBG sensors into a filament wound pressure tank, which includes a new protecting technique of sensor heads, the grating parts. From the experimental results, it was demonstrated that FBG sensors can be successfully adapted to filament wound pressure tanks for their structural health monitoring by embedding.

  • PDF

지오컴포지트를 이용한 양압력 제거공법 (Uplift Pressure Removal System in Underground Structure by Utilizing Geocomposite System)

  • 신은철;김종인;박정준
    • 한국지반공학회논문집
    • /
    • 제22권9호
    • /
    • pp.61-68
    • /
    • 2006
  • 최근 대규모 토목 건설 프로젝트는 용지 매입비용 및 각종 민원으로 인하여, 공유수면을 매립하거나 해안 및 하천지역의 용지를 활용하고 있다. 공유수면을 매립한 지반이나 해안 및 하천 지역의 지반은 충분한 지지력을 발휘하지 못하는 연약지반이 대부분이다. 이러한 연약지반은 주로 점토나 실트와 같은 미세한 입자의 흙이나 간극이 큰 유기질토 또는 이탄, 느슨한 모래 등으로 이루어진 토층으로 구성되어 있으며, 지하수위가 높기 때문에, 제체 및 구조물의 안정과 침하 문제를 발생시킬 수 있다. 본 연구에서는 지오컴포지트의 수리특성을 평가하기 위해 상재하중에 따른 통수성과 전수성 실내시험을 수행하였으며, 지하수위가 높은 지반에 지하구조물을 축조할 경우 발생될 수 있는 지하수 누수 및 양압력을 제거하기 위하여 토목섬유를 적용한 배수시스템을 연구하였다. 지반의 조건상 양압력으로 인한 문제점이 많이 발생되는 매립지의 준설토를 이용하여 실내배수실험을 수행하였다. 실내 배수실험에서는 실험기 하부에 토목섬유 배수층을 설치한 후에 상부에 준설토를 다져 넣고 상부에서 단계별 수압을 가하여 배수량과 간극수압을 측정하여 각각의 수압에 따른 계측값들과 이론적인 값들과 비교하였다. 실내배수실험의 타당성을 분석하기 위하여 흙이나 암석과 같은 다공질 재료의 간극수압 분포나 이동을 해석하기 위한 2차원 유한요소 해석프로그램을 이용하여 수치해석을 수행하여 실내실험의 결과와 비교하였다.

상수관로 압력계 최적 위치선정을 위한 데이터기반 시험분석 (Data-based Analysis for Pressure Gauge Optimal Positioning in Water Supply Pipeline)

  • 이호현;홍성택
    • 한국정보통신학회논문지
    • /
    • 제25권6호
    • /
    • pp.834-840
    • /
    • 2021
  • 먹는 물을 생산하여 공급하는 상수도 관로에 있어서 압력계에 대한 설치와 관리 방안이 미비함에 따라 압력데이터 신뢰성의 확보 및 운영관리의 어려움을 겪고 있는 실정이다. 관망 및 펌프 등 운영관리 효율화 및 SWM(Smart Water Management)을 구현하기 위해서는 하부 계측 센서의 정확한 데이터 취득을 통하여 의사결정이 이루어져야 한다. 따라서, 본 연구에서는 게이트 밸브와 버터플라이 밸브를 중심으로 관로의 직경(D)을 기준으로 전단 -3D에서부터 후단 7D까지 압력계를 설치하여 밸브의 개도율을 조절하며 데이터를 취득하는 직관 거리 시험을 실시하였으며, 관로에 수직으로 상단(180°)부터 하단(0°)까지 45° 각도 간격으로 압력계를 설치한 후 수직 위치 시험을 실시하였으며, 이 결과들을 바탕으로 압력계의 최적 위치선정 방안을 제시하고자 한다.

섬유혼합 점토의 비배수 강도 특성에 대한 연구 (Study on the Undrained Strength Characteristics of Fiber Mixed Clay)

  • 박영곤;장병욱
    • 한국농공학회:학술대회논문집
    • /
    • 한국농공학회 1998년도 학술발표회 발표논문집
    • /
    • pp.382-387
    • /
    • 1998
  • Triaxial compression tests were run to study on the undrained strength characteristics of fiber mixed kaolin clay(Hadong). The influence of various test parameters such as amount and aspect ratio(ratio of length to diameter) of fiber, confining stress was also investigated. Test results showed that the increase in aspect ratio was increased in deviator stress at failure, but no effect on pore water pressure at failure. Deviator stress at failure was also increased at 0.5% mixing ratio(weight fraction of fiber to that of soil solid) of fiber but it was, thereafter, decreased and wits reached to constant after 2% mixing ratio. On the contrary, Pore water pressure at failure was increased as mixing ratio of fiber was greater than 1%. Deviator stress and pore water pressure of both clay and fiber mixed clay(FMC) at failure were increased as confining stress was increased. Deviator stress of FMC at failure was about 10% larger than that of clay, but pore water pressure of FMC at failure was almost similar to that of clay.

  • PDF

1-G 진동대 실험을 이용한 시트파일 보강재의 액상화 및 피해 방지 효과 (Liquefaction Prevention and Damage Reduction Effect of Reinforcement by Sheet Pile Using 1-G Shaking Table Test)

  • 심성훈;윤종찬;손수원;김진만
    • 한국지진공학회논문집
    • /
    • 제24권5호
    • /
    • pp.211-217
    • /
    • 2020
  • Earthquake preparedness has become more important with recent increase in the number of earthquakes in Korea, but many existing structures are not prepared for earthquakes. There are various types of liquefaction prevention method that can be applied, such as compaction, replacement, dewatering, and inhibition of shear strain. However, most of the liquefaction prevention methods are applied before construction, and it is important to find optimal methods that can be applied to existing structures and that have few effects on the environment, such as noise, vibration, and changes in underground water level. The purpose of this study is to estimate the correlation between the displacement of a structure and variations of pore water pressure on the ground in accordance with the depth of the sheet file when liquidation occurs. To achieve this, a shaking table test was performed for Joo-Mun-Jin standard sand and an earth pressure, accelerometer, pore water pressure transducer, and LVDT were installed in both the non-liquefiable layer and the liquefiable layer to measure the subsidence and excess pore water pressure in accordance with the time of each embedded depth. Then the results were analyzed. A comparison of the pore water pressure in accordance with Hsp/Hsl was shown to prevent lateral water flow at 1, 0.85 and confirmed that the pore water pressure increased. In addition, the relationship between Hsp/Hsl and subsidence was expressed as a trend line to calculate the expected settlement rate formula for the embedded depth ratio.

산사태 모형실험을 통한 강우강도 및 사면경사 변화와 간극수압과의 관계 연구 : 편마암 풍화토를 대상으로 (Characterization on the Relationships among Rainfall Intensity, Slope Angle and Pore Water Pressure by a Flume Test : in Case of Gneissic Weathered Soil)

  • 채병곤;이성호;송영석;조용찬;서용석
    • 지질공학
    • /
    • 제17권1호
    • /
    • pp.57-64
    • /
    • 2007
  • 본 연구는 국내에서 산자태 발생빈도가 매우 높은 편마암 풍화토를 대상으로 산사태 모형실험장치를 이용하여 강우강도 및 사면경사에 따른 간극수압 변화의 관계를 파악하기 위하여 수행되었다. 본 연구에서는 강우강도와 사면경사의 변화에 따른 다양한 실험조건하에서 일정 시간 간격으로 간극수압, 사면붕괴양상 및 변위 등을 각각 측정하였다. 실험결과에 따르면, 강우강도에 따른 간극수압의 관계는 강우강도가 클수록 간극수압 증가시간이 빠르며, 모형 토조의 위치별 간극수압 증가시간도 사면 상부에서 가장 빠른 것으로 측정되었다. 이를 표준사를 이용한 실험결과(채병곤 외, 2006)와 비교해 볼 때, 편마암 풍화토는 강우의 침투속도가 표준사에 비해 느린 것을 알 수 있으며, 이로 인해 사면하부로의 강우이동이 상대적으로 원활하지 않아 사면 상단부에서 간극수압의 증가가 빠른 것으로 해석된다. 한편, 간극수압의 증가는 사면의 경사가 작은 경우 먼저 발생하는 것으로 나타났다. 이러한 현상 역시 편마암 풍화토의 느린 강우 침투속도에 기인하는 것으로 생각된다.

미분무수 소화시스템의 도로터널 적용을 위한 실물 화재 실험 (Full-scale Fire Suppression Test for Application of Water Mist System in Road Tunnel)

  • 한용식;최병일;김명배;이유환;소수현
    • 한국화재소방학회논문지
    • /
    • 제25권3호
    • /
    • pp.51-56
    • /
    • 2011
  • 도로터널에서의 미분무수 소화시스템의 화재진압 특성을 조사하기 위해 실물 터널 화재 실험을 수행하였다. 적용된 소화시스템은 압력이 3.5 bar인 저압 물분무 소화설비와 60 bar인 고압 미분무수 소화시스템이다. 미분무수 소화시스템은 물분무 소화시스템의 1/6 만큼의 소화용수량을 사용한다. 화원 (fire source)은 실물 승용차와 유류화재를 모사한 화원면적 $1.4m^2$의 헵탄 연료 팬 화재로 구성하였다. 터널 내의 환기조건을 구현하기 위해 실물모형 터널의 한쪽 끝단에 유속(0.9~3.8 m/sec 범위) 발생장치를 설치하였으며, 화원에서 하류 방향으로 터널 내 온도분포는 K-type 열전대 트리를 사용하여 측정하였다. 실험 결과 고압 미분무수 소화시스템은 B급 화재의 경우 저압 물분무 시스템과 동등한 수준의 냉각효과를 보였다.

PE배관 버트 융착 시간에 따른 융착 특성 변화 (The Fusion Characteristic Varying with Butt Fusion Times for Polyethylene Pipe)

  • 이영순;장영오
    • 한국안전학회지
    • /
    • 제13권4호
    • /
    • pp.199-205
    • /
    • 1998
  • Butt fusions were practiced with butt fusion in the various conditions of fusion temperatures, pressure and time, and the tests of tesile strength, breaking water pressure and fusion features were also practiced so that the reliability of the butt fusion and the fittets fusion condition may be closely examined. And the width, height and thickness of the beads were also closely measured. The fittest fusion result was achieved in the condition of the temperature of $210^{\circ}C$, heating time hight pressure of 14 seconds on the pressure of $1.5kg/cm^2$, heating time hight pressure of 100 seconds and pressure buid-up time of 11 seconds. And in case of the temperature of $250^{\circ}C$, the fittest fusion result was showed in the condition of the heating time hight pressure of 3 seconds on the pressure of 1.0$kg/cm^2$, the heating time low pressure variable of 100 seconds. heating time hight pressure of 14 seconds and the heating maintenance of around 60 seconds. The result of breaking water pressure test of a test piece fusion in the fittest fusion condition was that the fusion condition of the PE pipe showed a good stability and hight reliance. Through this test, it is proved that the temperature of fusion PE pipes can be increased to $250^{\circ}C$ from $210^{\circ}C$. And it can be expected that the above fusion method greatly helps to reduce the fusion time.

  • PDF

콘크리트와 도막 방수층 계면에 발생되는 수증기압에 관한 실험적 연구 (An Experimental Study of Water Vapor Pressure that occurs at the Interface of a Fluid-Applied Membrane and Concrete)

  • 고진수;김문희;이성복;신윤호
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2006년도 추계 학술논문 발표대회 논문집
    • /
    • pp.147-150
    • /
    • 2006
  • Of the total defects that have occurred recently in the Korean construction market, over 30% are caused by the construction of defective waterproofing, and the phenomenon of air pockets in the waterproofing layer, which is caused by the concrete vapor pressure, is known to be the primary cause of defective waterproofing. Accordingly, in this study the theory about the relationship between water pressure and temperature as well as the damp-proofing volume of concrete and, then, the change of vapor pressure volume was measured and analyzed by making a test sample after spraying a dampness remover and a waterproofing material to a prepared test body. As a result of measuring the water vapor pressure for the surface temperature of the waterproofing layer with the fluid-applied membrane temperature based on about $10^{\circ}C$, which is the average temperature of Seoul, it was found that first, the fluid-applied membrane elevated up to about $40^{\circ}C$, and the water vapor pressure generated from the fluid-applied membrane was about $0.3kgf/cm^2$ when the surface temperature of the waterproofing layer was raised up to about $80^{\circ}C$. Second, when the fluid-applied membrane temperature of the waterproofing layer was raised from $30^{\circ}C\;to\;35^{\circ}C,\;about\;0.1kgf/cm^2$ of water vapor pressure was generated, and when supplying a thermal source to raise the fluid-applied membrane temperature of the waterproofing layer from $35^{\circ}C\;to\;40^{\circ}C$, approximately $0.05kgf/cm^2$ of water vapor pressure was generated.

  • PDF