• Title/Summary/Keyword: water pollution level

Search Result 478, Processing Time 0.026 seconds

Evaluation of Pollution Level Attributed to Nonpoint Sources in Nakdonggang Basin, Korea (낙동강수계 권역별 비점오염원 오염도 평가)

  • Lee, Jaewoon;Kwon, Heongak;Choi, Hanyoung
    • Journal of Environmental Impact Assessment
    • /
    • v.23 no.5
    • /
    • pp.393-405
    • /
    • 2014
  • In this study, the nonpoint sources were evaluated by calculating the Nadonggang basin regional water quality and nonpoint source pollution load discharged. And were selected the banks of first administration based on the results and the direction of the next administration. As a results of estimating the water quality about BOD concentration in the mid influence area in the Nakdonggang basin, it was founded that 10 sites for 'Ia' water quality level, 6 sites for 'lb' water quality level, 5 sites for 'II' water quality level, 1 sites for 'I' water quality level. The estimation of COD concentration in the mid influence area, It showed that 9 sites for 'Ib' water quality level, 6 sites for 'II' water quality level, 6 sites for 'III' water quality level, 1 site for 'IV' water quality level. The assessment of water quality made Mid influence area of Gumhogang, Nakdong Goryung, Nakdong Milyang and Namgang selected as the mid influence area of high pollution. And delivery loads of nonpoint sources were calculated for mid influence area in Nakdonggang basin(max delivery load : 17,706.7 kg/day for Gumhogang influence area). As the result of calculating NPS(nonpoint sources) delivery load and water quality at influence area in Nakdonggang basin, Gumhogang influence area was selected as an area for management priority among nonpoint sources.

A Study on The Change of University Student's Consciousness and Behavior for Environmental Problems Before and After Environmental Education(II) (환경교육 전.후 학생들의 환경문제에 대한 태도와 인식변화에 관한 연구(II))

  • Park, Ki-Hark;Lee, Duck-Nan
    • Journal of environmental and Sanitary engineering
    • /
    • v.22 no.4
    • /
    • pp.105-117
    • /
    • 2007
  • The research was conducted based on the 1012 cases questionnaire for the purpose of to evaluate the change effect of university student's consciousness and behavior before and after lecture on environmental problems. And this questionnaires were performed with self-administered by the university student who made a application for liberal arts related to environmental subjects. The results were as follows. According to the analysis results the most students responded that the most serious problem of environmental pollution before the lecture on environmental education was a genetic modified organism(3.64/4.00), but the most serious problem of environmental pollution was changed to the topic of water pollution(3.96/4.00) after the lecture on environmental problem. And also according to the analysis results dributed by gender were that boy students show a higher concerning(170%) than that of girl students(150%). The most good results obtained after lecture on environmental problem were water pollution(23.0%), air pollution(11.5%), waste material pollution(10.9%), food additives (10.0%), genetic modified organism(8.0%), endocrine disrupter(7.5%), respectively. And according to the analysis results distributed by a grade were that the concerning of a low grade(freshman, sophomore)were higher than that of a high grade(junior, senior) in the topic of water pollution, air pollution, waste material pollution. But there were high level of awareness on the topic of food additives, genetic modified organism, endocrine disrupter to the all students(freshman to senior). And according to the analysis results distributed by a major field of study were that students who major in art & athletics, liberal art and etc(public health) were show a deep concerning than that of science & engineering. Finally, the environmental education during the university class were effectively contribute to increase the awareness of the seriousness of environmental pollution problem(8.2%) and also contribute to the practical life after class also increase their consciousness of environmental problem(59.8%).

Application Load Duration Curve for Evaluation of Impaired Watershed at TMDL Unit Watershed in Korea (수질오염총량 단위유역의 유량조건별 수체 손상 평가를 위한 부하지속곡선 적용성 연구)

  • Hwang, Ha-Sun;Yoon, Chun-Gyeong;Kim, Ji-Tae
    • Journal of Korean Society on Water Environment
    • /
    • v.26 no.6
    • /
    • pp.903-909
    • /
    • 2010
  • The purpose of this study was evaluated on the applicability of Load Duration Curve Method (LDC Method) using HSPF watershed model and sampling data for efficient TMDLs in Korea. The LDC Method was used for assessment pollutant characteristics in watershed and water quality variation in each water flow level. Load Duration Curve is applied for judge the level of impaired water-body and can be estimated the impaired level by pollutant, such as BOD, T-N, and T-P in this study depending on variation of stream flow. As a result, BOD, T-P was usually exceed the standard value at low flow and dry hydrologic period. Improvement of effluent concentration from WWTP and riparian buffer protection zone are effective to improve the water quality. T-N showed the worst condition at mid-range hydrologic period and moist hydrologic period. Therefore, soil erosion control program and BMPs for non-point source pollution control is effective for recovery the water quality, which can be useful method for management of water quality in the plan of recovery water quality spontaneously. Applicability of LDC Method was evaluated in the Nakbon A watershed. However, we need to consider more detailed and accumulated data set such as accurate GIS data and detail pollution data, and WWTP discharge water quality data for accurate evaluation of watershed. Overall, The LDC Method is adequate for evaluation of watersheds characteristics, and its application is recommended for watershed management and TMDL Implementation.

Conservation Strategy on Stream Water Quality in the Mt. Bughansan National Park (II) -­With a Special Reference to the Factor influenced on Stream Water Quality Pollution­- (북한산국립공원의 계류수질 보전 전략 (II) ­-계류수질오염 영향인자를 중심으로­-)

  • Park, Jae-Hyeon
    • Journal of the Korean Society of Environmental Restoration Technology
    • /
    • v.5 no.1
    • /
    • pp.8-18
    • /
    • 2002
  • This research was conducted to establish the conservation strategy of stream water quality by analyzing the factors influenced on stream water quality in the northeastern part of Mt. Bughansan National Park from July 1998 to October 2001. The number of visitors resulted in the significant increase of electrical conductivity, which affected on pollution of the stream water quality. According to the multiple regression analysis, the pH of the stream water was related to dissolved oxygen and temperature of water at the 1% significant level. The electrical conductivity of the stream water was related to number of visitors, amount of $K^+$ and ${NO_3}^-$, total amount of ions, percentages of $Cl^-$ and $Na^+$ caused by solifluction soil at the 1% significant level. The anions($Cl^-$, ${NO_3}^-$ and ${SO_4}^{2-}$) of the stream water were related to number of visitors, electrical conductivity, air temperature, hardness, amount of ${NO_3}^-$, ${SO_4}^{2-}$, total ions, percentage of $Cl^-$, ${NO_3}^-$, ${SO_4}^{2-}$, amount of $Ca^{2+}$ caused by solifluction soil at the 1% significant level. To prevent the pollution of stream water in the northeastern part of Mt. Bughansan National Park, it is recommended that the number of visitors in the park should be managed and rehabilitated rapidly by measure to eco-friendly during the spring season.

Determination of Interception Flow by Pollution Load Budget Analysis in Combined Sewer Watershed (II) - Establishment of Intercepting Capacity and Reduction Goal of Overflow Pollution Load - (오염부하 물질수지 분석을 통한 합류식 하수관거 적정 차집용량 결정(II) - 차집용량과 월류오염부하 삭감목표 설정 -)

  • Lee, Doojin;Shin, EungBai
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.19 no.5
    • /
    • pp.557-564
    • /
    • 2005
  • The objective of this study is to evaluate a criteria of intercepting capacity and a reduction goal of overflow pollution load in combined sewer system. In the current criteria of intercepting capacity in the domestic sewage facility standard, it is known that three times of peak sewage (Q) in dry period or runoff flow by 2mm/hr is not appropriate since the intercepted flow is estimated by runoff and show different result even in the same watershed. Though a reduction goal of overflow pollution load can be determined from 1) same level of storm-water runoff pollution load in separated storm sewer, 2) less than 5% sewage load in dry weather period, by the domestic sewage facility standard, the simulated results from storm-water model show large differences between two criteria. While it is predicted that sewage pollution load standard three time larger than separated storm sewer standard in high population density and urbanized area, it is shown that separate storm sewer standard larger than sewage pollution load standard in middle population density and developing area. Accordingly, it is proposed that more reasonable intercepting flow and reduction goal of overflows pollution load should be established to minimize discharging pollution load in combined sewer systems. For the purpose, a resonable standard has to be amended by pollution load balance considering the characteristics of a watershed for generation, collection, treatment, and discharging flow.

Variation of hazardous substances in sewage ecotoxicological assessment (하수 원수내 유해물질 변화에 따른 생태독성평가)

  • Seo, Byong-Won;Lee, Ju-Hwa;Lee, Yong-Hoon;Kang, Seon-Hong
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.27 no.5
    • /
    • pp.603-610
    • /
    • 2013
  • According to industrialization, increased toxic chemicals discharge has been causing water pollution. Especially domestic sewage is a major source of water pollution. Sixty percent of the total wastewater discharged is domestic sewage. Self-purification capacity of rivers and streams is drastically reduced by the emission of domestic sewage, industrial wastewater and livestock wastewater. Although domestic sewage is managed by implementing standards and regulations, toxicity effect of domestic sewage to humans and the environment is not yet clearly understood. In this study, by using daphnia magna, the ecotoxicity of domestic swage was assessed. Cl, Cu, Pb, COD, T-N, DO, pH and residual chlorine were investigated as background concentrations. The experiments were conducted with water samples obtained from three local sewage treatment plants. The experiment results indicated that higher level of toxicity corresponds to the higher pollution concentrations. The higher level of combinations of background concentrations such as heavy metals leads to the worse ecotoxicity. Especially, the Cu concentration affects the TU value.

Characteristics on Stream Water Quality in the Northeastern Part of Puk'ansan National Park(III) - With a Special Reference to the Factor Influenced on Stream Water Quality Pollution - (북한산국립공원(北漢山國立公圓) 북동사면(北東斜面) 일대(一帶) 계류수질(溪流水質) 특성(特性)(III) - 계류수질(溪流水質) 오염(汚染)에 미치는 영향인자(影響因子)를 중심(中心)으로 -)

  • Park, Jae Hyeon
    • Journal of Korean Society of Forest Science
    • /
    • v.89 no.3
    • /
    • pp.297-305
    • /
    • 2000
  • This research was conducted to analyze the factors influenced on stream water quality pollution in the northeastern part of Puk'ansan National Park from July, 1998 to November, 1999. The number of visitor and the percentage of the amount of $Cl^-$ resulted in the increase of electrical conductivity, which affected on pollution of the stream water quality. The relationships between those factors should be statistical significance at the 5% level in multiple regression. The multiple regression equations for the percentage of dissolved oxygen at the stream water quality showed that dissolved oxygen and water temperature had statistical significance at the 1% level. The multiple regression equations for the amount of $Cl^-$ at the stream water quality showed that electrical conductivity, the amount of cation($K^+$, $Na^+$), the amount of $SO_4{^{2-}}$, total amount of ion, the percentage of the amount of $Cl^-$, and the percentage of the amount of $SO_4{^{2-}}$ had statistical significance at the 5% and 1% level. Also, The multiple regression equations for the amount of $NO_3{^-}$ at the stream water quality showed that the amount of cation($Na^+$, $Ca^{2+}$), the amount of $SO_4{^{2-}}$, the percentage of the amount of $Cl^-$, and the percentage of the amount of $NO_3{^-}$ had statistical significance at the 5% and 1% level. The multiple regression equations for the amount of $SO_4{^{2-}}$ at the stream water quality showed that the amount of $NO_3{^-}$, total amount of ion had statistical significance at the 5% level.

  • PDF

Effects of the Addition of Water-soluble Polymers on Silk Dyeing (수용성 고분자를 이용한 견의 염색)

  • 황은경;김문식;이동수
    • Journal of Sericultural and Entomological Science
    • /
    • v.40 no.2
    • /
    • pp.136-142
    • /
    • 1998
  • The low-pollution dyeing condition and dyeing method suitable for the silk fiber were investigated. Instead of surfactants, water-soluble polymers and electrolytes were added as auxiliary agents in the new process of dyeing. By the new method, the level dyeing and sufficient exhaustion were achieved. The K/S values of silk fabrics were little different among electrolytes added in the dye-bath.

  • PDF

Evaluation of Stream Water Quality to Select Target Indicators for the Management of Total Maximum Daily Loads (수질오염총량관리 대상물질 선정을 위한 하천수질 평가)

  • Park, Jun Dae;Park, Jae Hong;Oh, Seung Young;Lee, Jae Kwan
    • Journal of Korean Society on Water Environment
    • /
    • v.29 no.5
    • /
    • pp.630-640
    • /
    • 2013
  • It is one of the most critical steps identifying impaired waterbodies exactly in the selection of target water quality indicators for the management of Total Maximum Daily Loads (TMDLs). Excess ratio and excess level were applied and analyzed by the stream zone basis in order to evaluate water impairment for Nakdong, Geum, Youngsan and Seomjin rivers. Each river basin was divided into stream zones in the light of its watershed and waterbody characteristics. Selected water quality parameters discussed in this study were pH, DO, BOD, COD, SS, T-P, T-Coli and F-Coli. The excess ratios of the water quality parameters were used to discriminate water bodies that did not meet water quality standards. The excess levels were used to classify the degradation of water quality. The excess ratios and the excess levels to the water quality criteria of the medium influence areas were used for each stream zone. The results indicate that the excess ratios and the excess levels are varied on the stream zone in each river basin. Three parameters, pH, DO and SS, met water quality standards in all stream zones. The other five parameters indicated very high excess ratios in most waterbodies, and especially T-P and T-Coli revealed to be very high excess levels in some waterbodies. These parameters could be considered as major target indicators for the management of TMDLs.

The Water Quality Assessment based on the Algal Communities and Biotic Indices in Hongcheon river, Gangwon-do (강원도 홍천강의 조류군집과 생물학적 지수에 의한 수질 평가)

  • Baek, Jun Soo;Kim, Hun Nyun;Lee, Ok-Min
    • Journal of Korean Society on Water Environment
    • /
    • v.30 no.6
    • /
    • pp.596-604
    • /
    • 2014
  • This research has studied the physicochemical environmental factors and communities of epilithic diatom and phytoplanktons at Hongcheon river from December 2011 to September 2012. In case of TN, the result was hypertrophic, and for TP, it ranged from mesotrophic to eutrophic. As for BOD, Hongcheon river was rated level II or better, according to the water quality level; values were found to be below 3mg/L at most sites. Total of 83 and 114 taxa of epilithic diatom and phytoplanktons respectively, were found during the research. When assessed using the TSI, it ranged from oligomesotrophic to eutrophic. In case of DAIpo, it ranged from 64.1 to 99.5, and TDI ranged from 51.5 to74.0. These results signify good water quality, level B or better, for Hongcheon river. P-IBI was rated moderate to low, which showed higher pollution than other indices. Among the biological water quality measures analyzed in the Hongcheon river study, DAIpo best matches TDI and BOD, while TDI showed greater pollution. Therefore, P-IBI appears to be inappropriate when assessing the domestic small rivers and lakes.