Application of hydrology model and Monitoring on pumped-storage section in islands district (도서지역 양수저류 관개지구의 모니터링 및 수문모델 적용)

  • Kim, Young-hwa;Park, Ji-Sung;Lee, Yong-il;Han, Kuk-Heon;Kim, Chae-Soo
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2004.05b
    • /
    • pp.215-219
    • /
    • 2004
  • In this study, Types of irrigation water development in islands district were classified. The types were reservior, fleshwater lake, pumped storage, etc. Most of islands district has delveloped reuse irrigation system as a pumped storage system. But. Irrigation water-reuse ratio doesn't define a basis clearly and the value of measurement for water-reuse ratio doesn't exist so far. so, we measured Irrigation water-reuse to clarify for water-reuse ratio in a pumped storage system. Also, we need to develop hydrologic analysis and water balance method with characteristic factor of islands district. that make use of plan about security of agriculture water efficiently in islands district.

  • PDF

TRAVELING WAVE SOLUTIONS FOR A SHALLOW WATER MODEL

  • Jung, Soyeun
    • Honam Mathematical Journal
    • /
    • v.39 no.4
    • /
    • pp.649-654
    • /
    • 2017
  • In this note, we seek traveling wave solutions of a shallow water model in a one dimensional space by a simple but rigorous calculation. From the profile equation of traveling wave solutions, we need to investigate the phase portrait of a one dimensional ordinary differential equation $\tilde{u}^{\prime}=F(\tilde{u})$ connecting two end states of the traveling wave solution.

Improvement of Structure to Prevent Water Infiltration and oil leakage for Reduction Units of KTX (KTX 감속구동장치 수분유입 및 누유 방지를 위한 구조개선)

  • Lee, Min-Soo;Kim, Yong-Kee
    • Proceedings of the KSR Conference
    • /
    • 2007.05a
    • /
    • pp.20-25
    • /
    • 2007
  • KTX is being operated on Kyung-Pu High Speed Railroad Line and Ho-Nam Railroad Line from April 2004. Reduction units is occurring water infiltration at heavy snow and oil leakage because of labyrinth structure. This paper describes design method and evaluation technology to improve structure to prevent water infiltration and oil leakage for reduction units of KTX. This reduction units need high power and high speed to run and they have to make optimal lubricant without change current interface.

  • PDF

Evaluation of Ecotoxicity and Characteristics on Indirect Effluents and Related Wastewater (간접방류사업장 관련 폐수의 생태독성수준 및 특성 평가)

  • Kim, Jongmin;Shin, Kisik;Lee, Soohyung;Lee, Jungseo;Lee, Taekjune
    • Journal of Korean Society on Water Environment
    • /
    • v.33 no.4
    • /
    • pp.481-486
    • /
    • 2017
  • This paper aims to evaluate the characteristics of direct and indirect effluents'toxicity level and difference between two test durations (24 h and 48 h) of test method. The proportion of the indirect effluent samples which exceeded the ecotoxicity permit limitations (TU 1 or TU 2) showed more than 2 times higher than that of direct effluent samples. However, effluent toxicity of Wastewater Treatment Plants (WTPs) indicated less than TU 1 regardless of influent toxicity. From this results, treatment process was thought to have a good efficiency. WTP Salinity was very similar between influent and effluent. This trend could be reconfirmed by the component ratio of ion concentration between them and $Na^+$, $SO_4^{2-}$, $C^-$ lions which have a greater percentage than other ions. In addition, in case of high salinity, toxicity value also showed high level. To judge from above results, indirect effluents which were exempted from application of ecotoxicity standards, may need a new effluent limitations regardless of the treatment efficiency of WTP. According to circumstances, effective countermeasure may need to restrain the discharge of salinity-contained effluents which came from indirect-effluent factories. Test duration comparative study indicated that 48 h results were higher toxicity (exceeding rate of ecotoxicity criteria) than 24 h by the 5 to 5.4 percentage. 24 h test duration seemed to be useful in case of rapid detection, whereas 48 h test method could be applied for reinforcement of ecotoxicity regulatory system.

Parallel Reservoir Analysis of Drought Period by Water Supply Allocation Method (공급량 배분기법을 이용한 갈수기 병렬저수지 해석)

  • Park Ki-Bum;Lee Soon-Tak
    • Journal of Environmental Science International
    • /
    • v.15 no.3
    • /
    • pp.261-269
    • /
    • 2006
  • In this study, an optimization technique was developed from the application of allocation rule. The results obtained from the water supply analysis and reliability indices analysis of Andong dam and Imha dam which are consist of parallel reservoir system are summarized as the followings; Allocation rule(C) is effective technique at the parallel reservoir system because results of the water supply analysis, storage analysis and reliability indices analysis is calculated reasonable results. Also, reliability indices analysis results are not sufficient occurrence based reliability or quantity based reliability. Thus reliability indices analysis are need as occurrence based reliability, quantity based reliability vulnerability, resilience, average water supply deficits and average storage. And water supply condition is better varying water supply condition than constant water supply condition.

The investigation of erosion control works' condition in East sea fire area (동해안 대형 산불피해지의 사방사업 실태진단)

  • Yeom, Kyu-Jin;Chun, Kun-Woo;Cha, Doo-Song;Lee, Si-Young;Lee, Hyun-Kyu;Lee, Myung-Woog;Kim, Youn-Jin;Lee, Jin-Ho;Kim, Suk-Woo;Tsugio, Ezaki
    • 한국방재학회:학술대회논문집
    • /
    • 2007.02a
    • /
    • pp.509-512
    • /
    • 2007
  • The fire area need management to prevent enlargement of collapes and sinkage. and it need that repair Vegetation sack work, Soil arresting structure, Terrace-sodding works, Direct seeding works in greening works and Water cushion in erosion control dam. The whole of the Concrete stream grade stabilization structures were broken, it need to be repair. As pass the time, a lot of structures were abandoned. Therefore, it need to reorganize erosion control structures and the method of construction in the fire area

  • PDF

Developing a performance index for efficient improving techniques and implement of Smart Water Management (스마트물관리기술 평가툴 개발)

  • Lim, Kwangsuop;Lee, Namsoo
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2016.05a
    • /
    • pp.578-578
    • /
    • 2016
  • In the past decade, many countries developed varies promising theories, methodologies and technologies for water resources management, such as Smart Water in Korea, eWater in Australia, Intelligent Water in Untied States, and Internet of Water in China. It is no exaggeration to say that Smart Water Management(SWM) will have a major role to play in addressing the global water challenges in the background of climate change, population growth and rapid urbanization. As a result, we can see major shifts taking place in the structure of the water industry, with a need for new approaches, skills, and water management policies. All these point towards a brighter future for the smart water sector and a new water paradigm, with applications and potential throughout the water cycle. However, each countries have their technology and industry standard system which may swift similar innovation and technology into different channels. In that sense, developing a common performance index and standard docking adapter for assessing Smart Water Management Initiatives(SWMI) is crucial for drawing a linkage of SWMI and SWMs to a way to implement advanced technology across Asia and Pacific. The performance index and standard docking adapter will facilitate quantitative and qualitative effects of utilized SWM techniques.

  • PDF

Development of replacement priority by analysis of effect of water meter replacement (수도미터 교체 우선순위 선정기준 개발)

  • Son, Dong-Wan;Kim, Dong-Hong;Lee, Doo-Jin;Jung, Kwan-Sue
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.28 no.5
    • /
    • pp.509-516
    • /
    • 2014
  • This study describes a reasonable planning method for water meter replacement which can minimize the metering under-registration for an increasement of revenue water. The increment analysis of real water usage was used to establish a replacement plan. The meter replacement database collected from K City was used as the basis of this analysis. The database included 964 connections of domestic and non-domestic consumers that had their meter replaced by aging at 2011. The result showed that the corelation between unregistered water volume and water meter age was lower than commonly expected where the current criteria of replacement is only water meter age(8 years) excluding the meters older than 13 years. And in the analysis result of water usage for 8 years, the total amount and increment of water usage had a significant effect on unregistered water volume. However the relation was different tendency as a total volume and slope of increment. In case of total water volume was larger than 10,000, larger than 7,000 and increment of 0.0 ~ -0.3, larger than 6,000 and increment more than -0.3 were analysed to need a replacement because of metering under-registration.

Investigation on the Removal of Dissolved Aluminum Ion in Drinking Water (정수중(淨水中)의 용존(溶存)알루미늄 제어방안(制御方案)의 조사(調査))

  • Choi, Suing-Il;Kim, Moon-Jeong
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.11 no.1
    • /
    • pp.42-52
    • /
    • 1997
  • The affection of activated carbon on the dissolved aluminum ion in drinking water has been observed. In addition, the aluminum ion removal capability of activated, alumina, chitosan, and ion exchange resin have been investigated. Experimental results indicated that the coal based activated carbon released considerable amount of aluminum ion to the water while coconut shell based activated carbon didn't. However the release was not continuous. Activated alumina didn't show any recognizable removal capability for aluminum ion in water. Particulate chitosan has removed aluminum ion although dissolved chitosan has not. However it need to development a regeneration process for chitosan to be an effective mean for aluminum ion removal. Ion exchange resin showed a reliable aluminum ion removal capability. The ion exchange capacity was 2.63 meq/g resin for the aluminum ion in drinking water.

  • PDF

Effect of Increased Water Intake on the Alleviation of Heat Stress in Chicken (수분 섭취의 증가가 닭의 고온 스트레스 완화에 미치는 효과)

  • 이봉덕
    • Korean Journal of Poultry Science
    • /
    • v.21 no.2
    • /
    • pp.93-99
    • /
    • 1994
  • Chickens subjected to heat stress decrease their heat production by consuming less feed. The lowered feed intake naturally brings about decreased production performance of chicken. The only exception to this is the increased survivability. Birds drink less when they eat less. In hot enviror-mental temperature, chicken need more water for increased heat loss through evaporation an increased urine excretion. Thus, the increased water intake may alleviate the heat stress of chicken. Various electrolytes supplementation to feed or drinking water can alleviate the heat stress of chicken by their effect of increasing water intake. Lasalocid, an ionophorous coccidiostat, was found to have the effect of increasing water consumption of chicken, thereby improving the lowered production performance of heat-stressed chicken. Finally, dietary fiber could be another possible element which can exert beneficial effects on heat-stressed chicken.

  • PDF