• 제목/요약/키워드: water meter

검색결과 639건 처리시간 0.029초

수평관 내 물-공기 이상류 거동에 관한 실험적 연구 (An Experimental Investigation on the Behavior of Water-Air Two-phase Flows in a Horizontal Pipe)

  • 조한일;이경수;류시완
    • 한국안전학회지
    • /
    • 제32권1호
    • /
    • pp.75-81
    • /
    • 2017
  • A series of laboratory experiments has been performed in order to investigate the behavior of water-air two-phase flow in a horizontal pipe. A conductivity meter has been applied to detect the irregular alternation of air at the specific points in flows. The experimental condition has been established according to the water and air flowrates. Passing time, which is the time length for a measuring probe to pass through the entire length of a specific bubble, has been defined to evaluate the size of bubbles in the flow. Passing length, which can be considered as the equivalent value to bubble size and determined from the product of passing time and cross-sectional averaged velocity, and its corresponding occurrence frequency have been analyzed to classify the air flow patterns according to the condition of air and water fluxes. From the result, the dependancy of flow patterns on the variation of air-water flux ratio has been investigated and the existence of thresholds also checked for classifying the behavior of air in the flow.

광주시의 환경오염에 관한 조사연구 (수질 오염에 관하여) (Studies on the Environmental Pollution in Gwangju Area -A Study on Water Pollution of Gwangju Stream-)

  • 김병환;강영식
    • 한국환경보건학회지
    • /
    • 제7권2호
    • /
    • pp.97-105
    • /
    • 1981
  • Water Pollution of Gwangju Stream was examined for four months from 22 March 1981 to 7 June, 1981. For checking the water pollution, 6 sampling positions were selected 5 from main stream. We assumed that the water pollution of Gwangju stream was due to the organic materials, which came from the domestic sewage. The apparatus for this test were pH meter (Orion model 301), Dissolved Oxygen & Temperature meter(Delta model 1010). The results we obtained are as follows: 1. The average range for mid-stream(sp. 3, 4) was 3. 10~2.73ppm of Dissolved Oxygen(DO), 80.23~102.95ppm of Biochemical Oxygen Demand (BOD), 195. 10~165.90ppm of Suspended Solid (SS), 6.6~6.7 of pH. 2. The plankton identification in this survey period showed Cyanophyceae is 4 genera 5 species, Bacillariophycea 11 genera 14 species, Chlorophyceae 8 genera 15 species and Zooplankton 6 genera 7 species: total 29 genera 41 species. 3. To appear dominant plankton in polluted water, there were Paramecium, Euglena and Oscillatoria. 4. The results of biological water analysis were as follows: st. 1 was B-mesosaprobic to oligosaprobic, but st. 4 and st. 5 at stream in the midtown area seemed to be polysaprobic.

  • PDF

액체 밀도계 및 pH meter기를 이용한 감수제의 신속품질평가 가능성 분석 (Analysis of the Possibility of Rapid Quality Appraisal of Water-Reducing Agents Using the Liquid Densimeter and pH Meter)

  • 김민상;현승용;백철;조만기;한민철;한천구
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2017년도 춘계 학술논문 발표대회
    • /
    • pp.210-211
    • /
    • 2017
  • According to KS F 2560, water-reducing agents used when mixing concrete are to undergo quality evaluation testing slump, air contents, setting time, etc., when delivered from the admixture factory to the ready mixed concrete site. Yet in actual acceptance testing this could be substituted by the score report of the admixture company, in which a possibility of low reliability lies. Therefore this study sought to analyze whether by artificially changing the solid content rate of lignin- and naphthalene-based water-reducing agents and using a liquid densimeter evaluate the quality of the admixture. The results showed that the Type B liquid densimeter was most appropriate and 50cc the most appropriate capacity for the mass cylinder. Also, judging from the changes in density and pH according to the changes in solid content rate, it concludes that a rapid appraisal of the quality of lignin- and naphthalene-based water-reducing agents would be possible using a Type B liquid densimeter.

  • PDF

AA-GWR Water Retention Meter를 이용한 부동화 농도 측정법

  • 최창학
    • 한국펄프종이공학회:학술대회논문집
    • /
    • 한국펄프종이공학회 2003년도 춘계학술발표논문집
    • /
    • pp.80-92
    • /
    • 2003
  • The water retention of coating colors can be accurately measured by devices such as an AA-GWR water retention meter whose principle of measurement is based on pressure filtration of coatings under an externally applied air pressure over a certain period of time. It was hypothesized that such devices could be also used to determine the immobilization solids(IMS) of coating colors by determining a sudden drop in the rate of dewatering, that is, a sudden change in the drainage curves. To test this hypothesis, the immobilization solids of coating colors containing various thickeners and water retention additives at different levels were first accurately measured by a modified immobilization tester based on the well-known gloss drop method, and then their values were compared with those obtained by an AA-GWR water retention tester. They agreed very well and showed that the mean of the solids differences is 0.36% in the IMS points between both methods. This good agreement was not surprising because both test methods are based on the same end-point, that is, the immobilization solids point at which menisci begin to form at the coating surface. Theoretical considerations supporting this new method for measuring the immobilization solids of coating colors are presented and some recommendations for the test method are discussed. Also, the effect of various thickeners and water retention additives on the properties and printability of coated papers is discussed.

  • PDF

The effects of scour depth and riverbed condition on the natural frequencies of integral abutment bridges

  • Akbari, Reza;Maadani, Saeed;Abedi, Alireza;Maalek, Shahrokh
    • Structural Monitoring and Maintenance
    • /
    • 제6권2호
    • /
    • pp.85-101
    • /
    • 2019
  • The effects of foundation scour depth and riverbed condition on the natural frequencies of a typical cross-river integral abutment bridge have been studied. The conventional operational modal analysis technique has been employed in order to extract the modal properties of the bridge and the results have been used in the Finite Element (FE) model updating procedure. Two tests have been carried out in two different levels of water and wet condition of the riverbed. In the first test, the riverbed was in dry condition for two subsequent years and the level of water was 10 meter lower than the natural riverbed. In the second test, the river was opened to water flow from the upstream dam and the level of water was 2 meter higher than the natural riverbed. The results of these two tests have also been used in order to find to what extend the presence of water flow in the river and saturation of the surrounding soil affect the bridge natural frequencies. Finally, the updated FE model of the bridge has been applied in a series of parametric analyses incorporating the effect of piles' relative scour depth on the bridge natural frequency of the first four vibration modes.

스마트 워터그리드 네트워크의 원격 단말기 보안을 위한 암호화 모듈에 관한 연구 (A Study on Encryption Module for Remote Terminal Security of Smart Water-Grid Network)

  • 박승환;박형모;김창복
    • 한국항행학회논문지
    • /
    • 제17권6호
    • /
    • pp.712-719
    • /
    • 2013
  • 본 논문은 스마트 워터그리드의 원격단말기와 상위 서버단간의 검침 및 제어 데이터의 안정적 전송을 위한 보안모듈에 대해 연구하였다. 제안한 보안모듈은 기존에 보급되어 사용 중인 보안성 없는 원격 단말기에 부착할 수 있도록 구현되었다. 특히, 전기 분야의 스마트그리드와는 달리 스마트 워터그리드는 배터리 전원을 사용하므로 저 전력을 고려하였으며, 지하에 설치되는 계량기 위치에 의한 습하고 열악한 환경이 대단위 네트워크 시스템 구축 시 통신 장애 발생시키는 점을 고려하여 ARIA-GCM-128 대칭키 방식을 채택하였다. 본 논문의 암호화 모듈은 단말기의 검침 데이터와 상위 서버단의 제어 데이터에 대한 보안을 확보하고 임의로 위변조 되는 것을 방지하여 원격검침 시스템에 대한 안정성을 확보할 수 있도록 구현되었다.

습식방식의 초음파 유량계 시스템 개발에 관한 연구 (A Study on the Wet Type Ultrasonic Flow-meter System Development)

  • 이응석;권오훈;노명환;이형석
    • 대한기계학회논문집A
    • /
    • 제29권12권
    • /
    • pp.1638-1644
    • /
    • 2005
  • This paper suggests fur the study on a fluid velocity measuring system using ultrasonic transducer. In general, the time difference method to measure the distance between transducers has been known. In this paper, the practical technology for manufacturing ultrasonic flow meter system is studied using the time difference method. The ultrasonic transducer was designed and manufactured. The transmission and receiving algorithm for ultrasonic signal was studied. The ultrasonic flow measuring system was experimented in laboratory using a water reservoir for verifying the distance measuring accuracy. Finally, it was tested in flow calibration laboratory for the velocity measuring performance. The system, designed in this study, showed 0.3 mm resolution in distance measurement. For precise flow measurement, a high speed triggering algorithm is required for ultrasonic signal receiving.

정전용량 탐침을 이용한 토양수분 측정장치 개발 (Developement of Soil Moisture Meter using Capacitance Probe)

  • 김기복;이남호;이종환;이승석
    • 한국농공학회:학술대회논문집
    • /
    • 한국농공학회 2001년도 학술발표회 발표논문집
    • /
    • pp.65-68
    • /
    • 2001
  • This study was conducted to develop a soil moisture meter using capacitance probe. A parallel cylinder type capacitance probe (C-probe) was fabricated The 5 MHz of crystal oscillator was constructed to detect the capacitance change of the C-probe with moist soil. A third order polynomial regression model for volumetric water content having oscillation frequency changes at 5 MHz as independent variables presented the determination coefficient of 0.979 and root mean square error of $0.031\;cm^{3}cm^{3}$ for all soil samples. A prototype soil moisture meter consisting of the sample container, C-probe, oscillator, frequency counter and related signal procession units presented the correlation coefficient of 0.987 and the root mean square error of $0.032\;cm^{3}cm^{3}$ as compared with the oven drying method for unknown soil samples.

  • PDF

소형 푸루버의 유량계 검증 오차 연구 (Study on Flowmeter Proving Errors of a Small Volume Prover)

  • 백종승;임기원;최용문
    • 대한기계학회논문집
    • /
    • 제14권1호
    • /
    • pp.259-266
    • /
    • 1990
  • 본 연구에서는 지금까지 개발된 각종 소형 푸루버의 작동원리 및 장단점을 분 석 비교한 결과에 따라 이중 실린더형의 소형 푸루버를 직접 설계 제작하고, 개발된 소형 푸루버를 사용하여 펄스 주기 변동특성이 각각 다른 유량계를 대상으로 펄스보간 오차 시험을 실시하였다. 실험결과는 통계적 방법을 도입하여 분석함으로써 유량계 각각에 대하여 기대 검증 정확도 수준을 선정하였다. 또 기대검증 정확도가 좋지 않 게 예상되는 유량계에 대해서는 검증 정확도 향상 방안을 제시하였다.

A Case Study on Energy focused Smart City, London of the UK: Based on the Framework of 'Business Model Innovation'

  • Song, Minzheong
    • International journal of advanced smart convergence
    • /
    • 제9권2호
    • /
    • pp.8-19
    • /
    • 2020
  • We see an energy fucused smart city evolution of the UK along with the project of "Smart London Plan (SLP)." A theoretical logic of business model innovation has been discussed and a research framework of evolving energy focused smart city is formulated. The starting point is the silo system. In the second stage, the private investment in smart meters establishes a basement for next stages. As results, the UK's smart energy sector has evolved from smart meter installation through smart grid to new business models such as water-energy nexus and microgrid. Before smart meter installation of the government, the electricity system was centralized. However, after consumer engagement plan has been set to make them understand benefits that they can secure through smart meters, the customer behavior has been changed. The data analytics firm enables greater understanding of consumer behavior and it helps energy industry to be smart via controlling, securing and using that data to improve the energy system. In the third stage, distribution network operators (DNOs)' access to smart meter data has been allowed and the segmentation starts. In the fourth stage, with collaboration of Ofwat and Ofgem, it is possible to eliminate unnecessary duplication of works and reduce interest conflict between water and electricity. In the fifth stage, smart meter and grid has been integrated as an "adaptive" system and a transition from DNO to DSO is accomplished for the integrated operation. Microgrid is a prototype for an "adaptive" smart grid. Previous steps enable London to accomplish a platform leadership to support the increasing electrification of the heating and transport sector and smart home.