• 제목/요약/키워드: water main

검색결과 4,638건 처리시간 0.034초

Design of Micro Water Supply System Using Solar Energy

  • Sharma, Ekisha;Khatiwada, Nawa Raj;Ghimire, Anish
    • 적정기술학회지
    • /
    • 제5권1호
    • /
    • pp.8-17
    • /
    • 2019
  • Solar pumps, for water lift systems, is becoming popular in rural areas for supplying drinking water in dry seasons when its need is elevated. The development in technology has also made solar pumps readily available and cheap which has increased its demands. So, for scattered settlements having a limited budget for operation and maintenance costs, solar pump is preferred over grid connected electrical pumping systems. This primary objective of the study was to design a solar photovoltaic pumping drinking water supply system for a small health post which is about 45 km east from Kathmandu, the capital city of Nepal. The study also compared and verified the final design with the system's existing design prepared by a development agency. The water source for this study was a confined aquifer 115m below the surface. The water demand was calculated to be 11m3 per day. A 1500 kPa submersible pump attached to a motor was selected and installed. Along with that twelve solar panels, reservoir, transmission main and distribution main was designed. The outcomes conclude solar photovoltaic pumping water supply systems to be cost-effective with an estimated cost of only USD 0.84 million per MLD. Solar pumps require low maintenance and operation costs and its repairs can quickly be done by the local people. The study also shows that solar technology produces no sound, needs no fuel making it environmentally friendly.

수질 취약지역 및 관말에서 플러싱 적용 먹는물 수질 개선 효과 (Effects of flushing techniques on water quality at extremity with low chlorine residuals in drinking water distribution systems)

  • 고경훈;권지향;김인자;임우혁
    • 상하수도학회지
    • /
    • 제25권3호
    • /
    • pp.313-324
    • /
    • 2011
  • Several complaints from consumers on red or turbid waters were often filed at the same places although various efforts were made to improve water quality in the drinking water plant. The red water problems were occurred due to corrosion of main water pipe, especially at extremity. The low concentrations of chlorine indicating poor water quality were detected at the problematic location. To solve the poor water quality at the extremity, flushing techniques, i.e., conventional flushing, unidirectional flushing, and continuous flushing, were recently practiced. In this study, effects of conventional flushing on water qualities were examined by comparing turbidity and residual chlorine before and after flushing. In addition, more detailed analyses on water qualities at the tap water were conducted to learn a reduction pattern during flushing. Five items from geographic information system of water distribution were used to obtain a relationship with water quality, washing duration or amounts of washing water. The flushing was effective to meet the National Drinking Water Quality Standard with simple and relatively short time operation. The key operational parameter in flushing was amounts of washing water which should be estimated based on water quality of the consumer's tap water. The positive relationship between the residual chlorine and pipe length implied that detention time in the pipeline was the main cause of the complaints. More experiments on effectiveness of flushing are needed to determine reasonable strategies of flushing.

다변량 통계기법을 이용한 미호천 본류 수질특성 평가 (Assessment of Water Quality in the Miho Stream Using Multivariate Statistics)

  • 윤혜영;김지현;채민희;조윤해;천세억
    • 환경영향평가
    • /
    • 제28권4호
    • /
    • pp.373-386
    • /
    • 2019
  • 본 연구는 금강 수계 주요 지류인 미호천수계를 대상으로 수계의 공간적 특성을 조사하고, 수질분석과 통계분석을 이용하여 수질에 영향을 주는 주요인을 파악하였다. 조사 대상은 미호천 수계의 본류에서 수질측정망을 운영 중인 7개 지점으로 선정하였고, 2012년부터 2017년까지 6년간 측정망 수온 등 16개 항목, 기상자료 등을 사용하여 다변량 통계분석을 실시하였다. 수질 분석 결과, 유기물질 지표인 BOD와 COD의 6년간 평균 농도는 환경부 수질 및 수생태계 생활환경기준(하천)과 비교하여 III등급(보통)으로 나타났다. 지점별 비교 결과 질소계열과 인계열의 농도는 상류 지점에서 가장 높게 나타났으며, 이후 감소하는 경향을 보이다 수리적, 지형적 영향으로 다시 증가하는 것으로 나타났다. 공간 및 수질 특성을 고려한 계층적 군집분석 결과, 총 3개의 군집으로 평가되었으며, 수계에 유입되는 오염원의 영향이 큰 것으로 나타났다. 각 군집과 본류 전체를 대상으로 실시한 주성분 및 요인분석 결과, 각각 3~4개의 주성분이 추출되었다. 요인분석 결과 제1요인은 본류와 Cluster1,3에서 질소계열 요인과 계절적 요인, Cluster2에서 질소계열 요인과 수온으로 나타나 미호천 수계의 수질에 가장 큰 영향을 미치는 인자는 질소계열의 농도인 것으로 나타났다.

Defining a Smart Water City and Investigating Global Standards

  • Lee, Jung Hwan;Jang, Su Hyung;Lee, Yu Jin
    • 한국수자원학회:학술대회논문집
    • /
    • 한국수자원학회 2022년도 학술발표회
    • /
    • pp.505-505
    • /
    • 2022
  • This study shows the first output of the three-year project (2021-2023) to develop a Smart Water City (SWC) Global Standard and Certification Scheme ley by K-water, International Water Resources Association (IWRA) and Asia Water Council (AWC). There are three major parts in the first year. In Part 1, it investigates the essential features of cities today and details the water challenges currently faced and likely to be confronted in the future. It also investigates the functions that water fulfills in the urban environment, and how ICTs can contribute to improving those functions by each Urban Water Cycle. A definition of a Smart Water City is proposed following a discussion on the meaning of "smart development". This part of the report also presents different city cases from countries around the world to illustrate the urban water challenges and the technological and non-technological solutions that cities have put in place, including national and/or local policies and strategies. In Part 2, it defines what global standards indicators and certification schemes are and identifies their characteristics. Especially, it analyses in detail eight relevant standards and certification schemes measuring sustainable development and/or water resources management in urban settings. Standards elaborated by international organizations are distinguished from those developed by the private sector, non-governmental organizations, and by academia. Finally, this study suggests the right direction to develop SWC global standard frameworks and certification schemes. And then, it shows the main tasks for the Stage 2 (second year) project. Basically, the framework for a future SWC standard (consisting three main pillars: Technical, Governance and Prospective pillars) will be fully defined in Stage 2.

  • PDF

Experimental Studies on Acration in Water

  • Paik, Nam-Won;Chung, Kyou-Chull
    • 한국환경보건학회지
    • /
    • 제2권1호
    • /
    • pp.25-28
    • /
    • 1975
  • The main purpose of the aeration units in activated sludge process is to enable micro-organisms to metabolize the constituents of the waste effectively by supplying sufficient oxygen for their respiration. Normally, aeration is achieved by bringing the mixture of waste and sludge into intimate contact with air. The main type of aeration unit is diffused air unit in which air is injected into the liquid in the form of bubbles. The object of these laboratory studies is to compare the performance of three laboratory scale aeration systems at various depths of submergence, aerating water with and without the addition of a surface active agent.

  • PDF

사이드스트림 오존 접촉조에서 수처리 효율 향상을 위한 정적혼합기와 미세기포에 관한 연구 (A Study on the Static mixer and Microbubble of the Sidestream Ozone Contact System to Improve Water Treatment Efficiency)

  • 김진훈;박종호
    • 상하수도학회지
    • /
    • 제23권6호
    • /
    • pp.763-768
    • /
    • 2009
  • Ozone is a strong oxidant and a powerful disinfectant. In general, it has been used in drinking water treatment during last 100years. Ozone dissolution features are defined by the two categories of ozone contactors, bubble-diffuser and sidestream ozone contactor. Currently, sidestream-injection systems are gaining in popularity but operating cost might be slightly higher. Sidestream ozone system dissolve ozone into a sidestream flow via an injection setup or in the main process flow stream in some sidestream arrangements. The sidestream flow is subsequently mixed with the main process flow stream, which is directed to a reation tank or pipeline for oxidation and disinfection reactions. The purpose of this study is to suggest optimal operating pressure, to figure out the static-mixer effect and to understand the microbubble characteristics of ozone to improve dissolution efficiency.

어항의 정온도 향상과 수질개선을 위한 기초적 연구 (A Fundamental Study on the Improvement of Harbour Tranquility and Water Quality of Fishing Port)

  • 류청로;김종화;박종화
    • 수산해양기술연구
    • /
    • 제26권4호
    • /
    • pp.341-352
    • /
    • 1990
  • The purpose of this research is to develop the design/control method that can be used for the improvement of harbour tranquility and water quality of fishing ports. For this end, firstly, the hydraulic environmental characteristics of fishing ports in the coastal waters of the Korean Peninsula are analysed and discussed combined with disasters of facilities and vessels in the ports. Secondly the problems of water quality control is pointed out considered with the improvement measures of harbour tranquility such as the methods of lengthen of main breakwaters and construction of wave absorbing structures. Finally, the control characteristics of composite functions of water quality and tranquility of fishing port are discussed and the improved control method si proposed using the experimental results for the various measures. The proposed measure is proved to be a applicable method to improve these two main functions on the design of fishing port.

  • PDF

Design of Satellite System for the Back-up System of Unmanned Control Plant

  • Chung, Kee-Heon;Yoon, Young-Hwan;Byun, Doo-Gyoon
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2001년도 ICCAS
    • /
    • pp.170.4-170
    • /
    • 2001
  • Safety and confidence of the communications network is the main purpose for the unmanned control systems, in terms of appling a satellite communications network to the water treatment and supply plant communication system. Since the unmanned control systems were applied in the industrial site, the lack of confidence on the communications network has been presented continuously as a main problem for the unmanned and automation systems. Therefore, satellite communications network was presented as one of the methods to solve this problem, supporting the wire used telecommunication. In addition to the safety of a communications network, there is the retrenchment of expenditure. This dual communications network has ...

  • PDF

벽천 디자인에 관한 연구 (A study on great wall design of the main gate in campus)

  • 한혜련
    • 한국실내디자인학회:학술대회논문집
    • /
    • 한국실내디자인학회 2004년도 추계학술발표대회 논문집
    • /
    • pp.173-174
    • /
    • 2004
  • The Great Wall is an element in University which stand outs as a landmark. The Great Wall is located in front of the grand staircases of the gymnasium in the main gate area. Falling water and Lights shows a spectacle panorama in various point of view. Water falls down the top of the grand staircases and the front walls. And the red, blue and green lights brighten the falling water in the evenings. Also the relief of the palm tree and turtle symbolizes the University Identity. The wall is comprehends not only the day and the night but four seasons. The Water, Lights, and the Relief are coordinates well along with the new building in campus.

  • PDF

SMART 원자로용 냉각재 순환펌프의 온도특성에 관한 연구 (A Study on the Temperature Characteristics of Main Coolant Pump for System-integrated Modular Advanced Reactor)

  • 구대현;방덕제;강도현;김종인;조윤현
    • 대한전기학회논문지:전기기기및에너지변환시스템부문B
    • /
    • 제49권5호
    • /
    • pp.320-326
    • /
    • 2000
  • The canned motor of 3-phase induction is used for main coolant pump(MCP). The type of motor is canned-motor that stator and rotor are welded by sealed can. So, cooling water flows in the air gap of the canned motor as an independent cycling cooling system from the air gap to yoke of the motor to prevent high temperature of stator can and to lubricate bearing. Heat exchange is occurred between cooling water in the air gap and cooling water from the exterior pump to prevent rising of temperature in the motor. I has to analyze the characteristics of can exactly because the loss and the heat in the can are very important to design MCP. Therefore, thermal analysis is studied considering the effect of eddy-current los induced in the can.

  • PDF