• 제목/요약/키워드: water level sensor

검색결과 172건 처리시간 0.026초

부분적으로 유체가 채워진 원통형 관내의 외팔보 진동해석 (Vibration Analysis of an Cantilever Beam in Partially Liquid-Filled Cylindrical Pipe)

  • 권대규;유계형;방두열;이성철
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2003년도 춘계학술대회논문집
    • /
    • pp.1073-1078
    • /
    • 2003
  • This paper presents the vibration characteristics of a cantilever beam in contact with a fluid using a PZT actuator and PVDF film. dynamic behaviors of a flexible beam-water interaction system are examined. The effect of the liquid level on free vibration of the composite beam in a partially liquid-filled circular cylinder is investigated. The coupled system is subject to an undisturbed boundary condition un the fluid domain. In the vibration analysis of a wetted beam. the decoupled analyses between beam and fluid have been conventionally employed by considering first the composite beam vibration in the all and secondly Performing the correction taking account for surrounding fluid effects. That is, this investigation was to look at how natural frequencies, mode shapes. and damping are affected by liquid level variations. The signals from the sensor according to the applied input voltage are digitalized and filtered in order to obtain the dynamic characteristics of the composite beam in contact with fluid. It was found that the coupled natural frequencies decreased with the fluid level for the identical composite beam due to added mass effect. In case of the free-free boundary condition, the natural frequency gently decreased at fluid water level between 20% and 80% in the first tending mode and we found out the bends of stair shape for added mass effect of the fluid.

  • PDF

광섬유와 OTDR을 이용한 실시간 수위 및 온도 측정 (Real-time Measurements of Water Level and Temperature using Fiber-optic Sensors Based on an OTDR)

  • 심혁인;유욱재;신상훈;장재석;김재석;장경원;조승현;문주현;이봉수
    • 전기학회논문지
    • /
    • 제63권9호
    • /
    • pp.1239-1244
    • /
    • 2014
  • In this study, two fiber-optic sensors were fabricated to measure water level and temperature using optical fibers, a coupler, a Lophine and an OTDR (optical time-domain reflectometer). First, using Fresnel's reflection generated at the distal-ends of each optical fiber, which was installed at different depth, we measured the water level according to the variation of water level. Next, we also measured the temperature of water using a temperature sensing probe based on the Lophine, whose absorbance changes with the temperature. The measurable temperature range of the fiber-optic sensor is from $5^{\circ}C$ to $65^{\circ}C$ because the maximum operation temperature of the optical fiber without a physical deterioration is up to $80^{\circ}C$.

지하수위에 따른 철도사면의 안정성 변화 (The Variation of Slope Stability by Ground Water Level in Railway Lines)

  • 김현기;신민호;신지수
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2008년도 추계학술대회 논문집
    • /
    • pp.789-795
    • /
    • 2008
  • Slope stability is affected by various factors. For safety management of slopes, monitoring systems have been widely constructed along railway lines. The representative data from the systems are variations of ground profile such like ground water level and pore water pressure etc. and direct displacement measured by ground clinometer and tension wire sensor. Slopes are mainly effected by rainfall and rainfall causes the decrease of factor of safety(FOS). Because FOS varies linearly by the variation of ground water level and pore pressure, it has a weak point that could not define the time and proper warning sign to secure the safety of the train. In this study, alternative of FOS such as reliability index and probability of failure is applied to slope stability analysis introducing the reliability concept. FOS, reliability index, probability of failure and velocity of probability of failure of the slopes by variation of ground water level are investigated for setting up the specification of safety management of slopes. By executing case study of a slope(ILLO-IMSUNGLI), it is showed to be applied to specification of safety management.

  • PDF

Observation of Water Level and Temperature Properties by using a Giant Magnetoresistance-Spin Valve Film

  • Choi, Jong-Gu;Park, Kwang-Jun;Lee, Sang-Suk
    • Journal of Magnetics
    • /
    • 제17권3호
    • /
    • pp.214-218
    • /
    • 2012
  • The water level and temperature properties for the cooling system of potassium titanyl phosphate laser systems were observed. The middle point of the GMR-SV magnetoresistance curve is set in the neighborhood of high magnetic sensitivity (2.8 %/Oe). The experimental results for resistance dependence on water height and temperature showed linear regions with rates of 0.4 ${\Omega}/mm$ and 0.1 ${\Omega}/^{\circ}C$, respectively. The proposed results were found to be for adjusting the water level and temperature in the laser cooling system.

선박 평형수 처리 시스템의 안드로이드 원격 모니터링 시스템 (Android Remote Monitoring System of Ballast Water Treatment System)

  • 최휘민;서지노;이광섭;김선종;김주만
    • 한국인터넷방송통신학회논문지
    • /
    • 제15권6호
    • /
    • pp.217-224
    • /
    • 2015
  • 본 논문에서는 안드로이드 기반 장치에서 선박 평형수 처리 시스템의 센서 데이터를 시간과 장소에 구애받지 않고 원격 모니터링이 가능한 시스템을 설명한다. 제안하는 원격 모니터링 시스템은 선박 내에 설치된 선박 평형수 처리 시스템에 문제가 발생하였을 경우 파견되는 엔지니어를 위한 정보를 제공한다. 시스템은 선박으로부터 수집된 센서데이터를 보존하는 서버와 이동이 자유로운 모바일 장치로 구성된다. 서버의 센서 데이터는 모바일 장치에서 원하는 조건을 입력하고 요청한다. 모든 센서 데이터를 수신할 경우 모바일에서 처리되는 시간이 길어져 문제가 발생했을 때 치명적일 수 있는 중요도가 높은 센서 데이터만을 수신하여 사용자에게 제공한다. 서버와 모바일 장치의 데이터 송수신은 안전한 통신을 위해 TCP/IP를 사용한다. 본 시스템에서는 선박 평형수 처리 시스템의 원격 모니터링 정보를 통해 센서의 고장을 예측한다.

Reactor Vessel Water Level Estimation During Severe Accidents Using Cascaded Fuzzy Neural Networks

  • Kim, Dong Yeong;Yoo, Kwae Hwan;Choi, Geon Pil;Back, Ju Hyun;Na, Man Gyun
    • Nuclear Engineering and Technology
    • /
    • 제48권3호
    • /
    • pp.702-710
    • /
    • 2016
  • Global concern and interest in the safety of nuclear power plants have increased considerably since the Fukushima accident. In the event of a severe accident, the reactor vessel water level cannot be measured. The reactor vessel water level has a direct impact on confirming the safety of reactor core cooling. However, in the event of a severe accident, it may be possible to estimate the reactor vessel water level by employing other information. The cascaded fuzzy neural network (CFNN) model can be used to estimate the reactor vessel water level through the process of repeatedly adding fuzzy neural networks. The developed CFNN model was found to be sufficiently accurate for estimating the reactor vessel water level when the sensor performance had deteriorated. Therefore, the developed CFNN model can help provide effective information to operators in the event of a severe accident.

Design, analyses, and evaluation of a spiral TDR sensor with high spatial resolution

  • Gao, Quan;Wu, Guangxi;Yu, Xiong
    • Smart Structures and Systems
    • /
    • 제16권4호
    • /
    • pp.683-699
    • /
    • 2015
  • Time Domain Reflectometry (TDR) has been extensively applied for various laboratory and field studies. Numerous different TDR probes are currently available for measuring soil moisture content and detecting interfaces (i.e., due to landslides or structural failure). This paper describes the development of an innovative spiral-shaped TDR probe that features much higher sensitivity and resolution in detecting interfaces than existing ones. Finite element method (FEM) simulations were conducted to assist the optimization of sensor design. The influence of factors such as wire interval spacing and wire diameter on the sensitivity of the spiral TDR probe were analyzed. A spiral TDR probe was fabricated based on the results of computer-assisted design. A laboratory experimental program was implemented to evaluate its performance. The results show that the spiral TDR sensor featured excellent performance in accurately detecting thin water level variations with high resolution, to the thickness as small as 0.06 cm. Compared with conventional straight TDR probe, the spiral TDR probe has 8 times the resolution in detecting the water level changes. It also achieved 3 times the sensitivity of straight TDR probe.

낙동강에서 클로로필(Chlorophyll) 측정을 위한 클로로필 센서와 아세톤 추출법의 비교분석에 관한 연구 (A study on comparison and analysis of chlorophyll sensor with aceton extraction for chlorophyll measurement in the Nakdong River)

  • 박주현;이경진;조재원;전숙례;강선홍
    • 상하수도학회지
    • /
    • 제29권3호
    • /
    • pp.325-335
    • /
    • 2015
  • Concerns about water quality in the Nakdong River have been raised because the Nakdong River will change from a lotic environment to a lentic environmental due to the installation of eight weirs to be constructed as part of the Four Major Rivers Restoration Project. The rapid urbanization and industrialization of the middle and the lower reaches of Nakdong River causes the indiscreet discharge of uncleanly living sewage and industrial wastewater. And the water quality of lower reaches of Nakdong River is getting seriously worse. Owing to the water shortage of Nakdong River and the closing of reaches because of the estuary dyke in the dry season, the velocity of a moving fluid is almost accumulated under 0.03m/sec. Then a pollutant is piled up on the bottom of the river. Polluted sediment is formed and nutrition level of water is increased more and more. The eutrophication state propagated to dark brown or green from eutrophication often comes out. Therefore in this study, we measured Chl. a of chlorophyll sensor (YSI6600V2) and aceton extraction through field observation in the Nakdong River and Samrangjin. And we evaluated the reliability of chlorophyll sensor. In correlation analysis between chlorophyll sensor and aceton extraction, it shows high relation in general. And it also shows high relation among the chlorophyll sensor and aceton extraction of the dominant diatom (Skeletonema costatum), Dinophyta (Prorocentrum minimum) in the Nakdong River estuary by laboratory analysis results.

다중모드 광섬유 융착형 침수 감지 센서 개발 (Development of submersion sensors using multi-mode fibers spliced with a fiber Bragg grating)

  • 손경락;계광현;심준환;조석제
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제33권6호
    • /
    • pp.925-931
    • /
    • 2009
  • This paper reports a preliminary experimental investigation and characterization of an optical fiber-based submersion sensor system for applications in water flooding and leakage. The sensor system comprises a multi-mode fiber spliced with fiber Bragg grating and an intensity-based interrogator. Submersion tests were conducted in water-air and Glycerin-air environments. By the refractive index of the fiber-probe surrounding materials, the reflectance and the detecting power level is determined. When the probe is dipped into the water, the optical output power dramatically decreases from -7.5dBm to -17.5dBm. But, the center of Bragg wavelength is not affected in spite of external material changes. Temporal response characteristics of the sensor system is investigated to verify the real-time reaction. When the probe is immersed into the liquid, there is no transition time.

잔류염소 측정용 전기화학센서의 유효성 (Effectiveness of the Electrochemical Sensor for the Free Chlorine Measurement)

  • 김홍원;정남용
    • 한국생산제조학회지
    • /
    • 제21권5호
    • /
    • pp.720-725
    • /
    • 2012
  • Sodium hypochlorite is used worldwide as a water disinfectant and in bleaching agent. Sodium hypochlorite applied to water initially undergoes hydrolysis to form free chlorine consisting of hypochlorous acid(HOCl) and hypochlorite ion($OCl^-$). For free chlorine determination, an electrochemical method is simple due to the electroactivity of free chlorine; it measures current and is free of most reagents. Amperometric free chlorine sensor has been developed with gold (Au)-based electrode. The 3-electrode free chlorine sensor whose working and counter electrodes were Pt exhibited excellent response to HClO at +400mV vs. Ag/AgCl/sat. KCl. In addition, the use of a pH error correction algorithm provided a reliable measurement of residual free chlorine in water sample without any pretreatment in the normal pH range(pH 6~8) of municipal water supply. The free chlorine sensor installed in on-line monitoring system could be used to continually monitor the level of residual free chlorine in real samples.