• 제목/요약/키워드: water for injection

검색결과 1,368건 처리시간 0.027초

갈수기 정수장운영관리 사례 - 갈수기 pH저감제(황산)투입에 의한 정수처리효율 향상 (Improvement of Water Treatment Efficiency by pH Decreasing Agent (H2SO4) for Droughty Seasons)

  • 가길현;김윤용;이준호;안치화;한인섭;민병대
    • 한국물환경학회지
    • /
    • 제24권4호
    • /
    • pp.415-422
    • /
    • 2008
  • Drinking water treatment is enhanced by coagulant dosages and chlorine injection because of pH increase in raw water in droughty seasons such as spring and fall. But water quality deterioration is occurred by increase in residual aluminium and disinfection by-products. Coagulation process can be used to control natural organic matter (NOM) during water treatment. The effect of coagulation process appeared to depend on the pH of water rather than coagulant dosages. In this study, for water treatment in high pH season $H_2SO_4$ was applied for pH adjustment at full scale. Before and after pH adjustment by $H_2SO_4$ injection, water quality of drinking water was evaluate. In the result of investigation of total organic carbon (TOC) removal in high pH season, TOC was removed approximately 30~40%, which showed decrease in water treatment efficiency. Also, it is increased both particle numbers and residual Al concentration in the water. After $H_2SO_4$ injection for adjustment to pH<7.5 in settled water, treated water turbidity decreased in 0.047 NTU from 0.059 NTU, and particle numbers of filtered water decreased in 20/mL from 90/mL. On the other side, TOC removal efficiency increased in approximately 10% after adjustment of pH. In the result of decrease in pH in raw water through more coagulants and prechlorine without $H_2SO_4$ injection, trihalomethanes (THMs) concentration increased in $16{\mu}g/L$ from $8{\mu}g/L$.

해수침투 저감을 위한 담수주입시험 및 지구물리 모니터링 (Fresh Water Injection Test to Mitigate Seawater Intrusion and Geophysical Monitoring in Coastal Area)

  • 박권규;신제현;황세호;박인화
    • 지구물리와물리탐사
    • /
    • 제10권4호
    • /
    • pp.353-360
    • /
    • 2007
  • 본 연구에서는 담수 주입에 의한 해수침투 개선 가능성을 확인하기 위해 담수주입 현장 실증시험을 수행하였으며, 담수 주입 효과 및 거동 평가를 위해 시추공에서의 다채널 전기전도도 모니터링과 물리검층, 지표에서의 전기비저항 및 자연전위 모니터링을 수행하고 그 적용성을 평가하였다. 담수주입 전후 및 주입 기간 중 수행된 물리검층과 다채널 전기전도도 모니터링 결과 담수 주입에 따른 공내수 및 대수층의 전기전도도의 감소 양상과, 이러한 주입효과가 수개월 이상 지속됨을 확인할 수 있었다. 담수주입에 따른 지하수의 유동 탐지를 목적으로 한 자연전위 모니터링의 경우, 현장 기상 여건 및 비분극 전극의 장기간 활용에 따른 문제로 인해 의미 있는 결과를 얻지 못하였으나 전기비저항탐사 모니터링의 경우에는 주입 담수에 의한 영향이 주입정 주위의 전기비저항 증가 양상으로 관측되어 담수체 거동과 영향 반경을 확인할 수 있었다. 이로부터 담수주입에 의한 담수체의 거동 평가와 개선효과를 판단하는 방법으로서 지구물리 기법들이 효과적으로 적용될 수 있으며, 이러한 평가기술에 기반 한 최적설계가 이루어질 경우 담수주입기술이 해수침투 피해 개선을 위해 효과적으로 적용될 수 있을 것으로 판단된다.

Gravity-Injection Core Cooling After a Loss-of-SDC Event n the YGN Units 3 & 4

  • Seul, Kwang-Woo;Bang, Young-Seok;Kim, Hho-Jung
    • Nuclear Engineering and Technology
    • /
    • 제31권5호
    • /
    • pp.476-485
    • /
    • 1999
  • In order to evaluate the gravity-injection capability to maintain core cooling after a loss-of-shutdown-cooling event during shutdown operation, the plant conditions of the Yong Gwang Units 3&4 were reviewed. The six cases of possible gravity-injection paths from the refueling water tank (RWT) were identified and the thermal-hydraulic analyses were performed using the RELAP5/MOD3.2 code. The core cooling capability was significantly dependent on the gravity-injection path, the RCS opening, and the injection rate. In the cases with the pressurizer manway opening higher than the RWT water level, the coolant was held up in the pressurizer and the system pressure continued increasing after gravity-injection. The gravity injection eventually stopped due to the high system pressure and the core was uncovered. In the cases with the injection path and opening on the same leg side, the core cooling was dependent on whether the water injected from the RWT passed the core region or not. However, in the cases with the injection path and opening on the different leg side, the system was well depressurized after gravity-injection and the core boiling was successfully prevented for a long-term transient. In addition, from the sensitivity study on the gravity-injection flow rate, it was found that about 54 kg/s of injection rate was required to maintain the core cooling and the core cooling could be provided for about 10.6 hours after event with that injection rate from the RWT. Those analysis results would provide useful information to operators coping with the event.

  • PDF

물 분사 시스템에 의한 소형 디젤엔진의 NOx 및 그 외 배출물의 특성에 관한 연구 (A Study on the Characteristics of NOx and another Emisson by Water Injection System for a Light-Duty Diesel Engine)

  • 최재성;남정길
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제29권6호
    • /
    • pp.628-636
    • /
    • 2005
  • In this paper. the effects of a WI(Water Injection) in the intake pipe for a 4-cylinder Dl(Direct Injection) diesel engine are investigated experimentally, The WI system was controlled by the duty cycle from the intake manifold's temperature and MAF(Manifold Air Flow) First. effect of EGR on NOx reduction was investigated. Then WI system was applied to reduce NOx As the results. we can make the NOx map and visualize the NOx results by variation of engine speed and engine load It was known that effect of WI system on NOx reduction without the EGR was better than the with EGR base engine except of low load and speed condition.

탄산가스 주입이 압출팽화 옥수수전분의 성질에 미치는 영향 (Effect of $CO_2$Gas injection on Properties of Extruded Corn Starch)

  • 류기형;강선희;이은용;임승택
    • 한국식품영양과학회지
    • /
    • 제26권3호
    • /
    • pp.436-442
    • /
    • 1997
  • Corn starch was extruded under relatively low shear, high moisture, and low temperature. Puffing of corn starch dough was induced by injecting $CO_2$gas in the range from 0MPa to 0.09MPa. Piece density and compressive modulus for puffed corn starch were decreased by increasing the injection pressure to 0.07MPa, and increased above 0.07MPa. the microstructure of corn starch puffed with $CO_2$gas showed thick cell size, compared with those puffed with steam. RVA paste viscosity curves of corn starch puffed with $CO_2$had different patterns from those puffed with steam, probably resulted from partial gelatinization of starch. Water absorption and solubility were not significantly changed by $CO_2$injection pressure, but the average degree of polymerization was reduced by higher $CO_2$injection. The water absorption, water solubility, and the average degree of polymerization for corn starch puffed with $CO_2$were significantly lower than those puffed with steam.

  • PDF

Scanning Electron Microscopic Study of Slime Formations in a Water Injection Station of Oil India Limited in Assam, India

  • Bhagobaty, Ranjan K.;Purohit, S.;Nihalani, M.C.
    • Applied Microscopy
    • /
    • 제45권4호
    • /
    • pp.249-253
    • /
    • 2015
  • Microorganisms specifically groups of bacteria exhibiting physiological activities of production of acids are a major cause of concern because of their ability to induce corrosion in oil field pipelines and metal systems involved in water handling. Water Injection Stations as a means of secondary recovery from existing oil producing reservoirs, are often employed in most upstream oil and gas industries to ensure replenishment of voidage, maintenance of reservoir pressure and optimization of crude emulsion throughput. In the present study, scanning electron microscopy of macroscopic orange coloured slime formations sampled from leaking valves on the flow-lines of a Water Injection Stations of Oil India Limited revealed the presence of filamentous bacterial mats in association with diatoms. The species composition of the acidic slime formations from the sampled locations reveal the possible role of acid producing iron oxidizing bacteria (IOB) like Acidithiobacillus ferrooxidans in association with Gomphonema sp. in creating conditions for bio-corrosion.

Nozzle effect on the formation of Methane hydrate

  • 서향민;박성식;김남진
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2008년도 추계학술대회 논문집
    • /
    • pp.226-229
    • /
    • 2008
  • When methane hydrate is artificially formed to store and transport large quantity of natural gas, its reaction time may be too long and the gas consumption in water becomes relatively low, the reaction rate between water and methane gas is low. Therefore, the present investigation focuses on the rapid production of hydrates and increases the gas consumption by injecting water into methane gas utilizing nozzle. the hydrate in water injection using a nozzle formed rapidly more than that in gas injection, and the gas consumption of methane hydrate in water injection is about three to four times greater than that in gas injection according to subcooling.

  • PDF

1단용 액체로켓엔진 후류의 물분사 방식에 따른 수치적 냉각 성능 평가 (Numerical Evaluation of Cooling Performance of 1st Stage Liquid Rocket Engine Plume by Water Injection Types)

  • 문윤완;김승한;설우석
    • 한국추진공학회:학술대회논문집
    • /
    • 한국추진공학회 2010년도 제35회 추계학술대회논문집
    • /
    • pp.739-740
    • /
    • 2010
  • 1단용 액체로켓엔진 후류 때문에 발생하는 유도로의 열적 부하를 감소시키기 위한 방법 중 물분사 방식의 효과적인 냉각 성능을 고찰하기 위해 두 가지 방법과 다양한 물분사 조건에 대해 수치적 계산을 수행하였다. 중앙분사 방식이 측면분사 방식보다 보다 효과적으로 후류를 냉각시켜 유도로의 열적부하를 감소시킴을 알 수 있었다.

  • PDF

2D 유한요소 해석을 통한 Water injection pump의 동특성 분석 (Analysis of dynamics characteristics of water injection pump through the 2D finite element)

  • 이종명;김용휘;김준호;최현철;최병근
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2014년도 춘계학술대회 논문집
    • /
    • pp.408-414
    • /
    • 2014
  • After drilling operations at the offshore plant to production to crude oil to high pressure. After that time the low pressured of pipe inside when the secondary produce so oil recovery is reduced. At that time injection sea water at the pipe inside through water injection pump that the device Increase recovery so to be research and development at many industry. So developing 3-stage water injection pump at the domestic company. A variety of mathematical analysis during the detailed design analysis was not made through the dynamics characteristic. In this paper, a 2D finite element analysis is performed through the dynamics of the present study was the validation of the model.

  • PDF

충진층식 세정집진기의 집진특성 실험 (An Experiment on the Particle Collection Characteristics in a Packed Wet Scrubber)

  • 유경훈;노희환;최은수;김종균
    • 설비공학논문집
    • /
    • 제15권4호
    • /
    • pp.305-311
    • /
    • 2003
  • DOP aerosol particles with geometric mean diameter of 0.5-3.0 ${\mu}{\textrm}{m}$, geometric standard deviation of 1.1-1.3 and total number concentration of 1,500-8,000 Particles/㎤ were used to determine collection efficiencies of a packed wet scrubber with respect to particle size. The tested operating variables included air velocity and water injection rate. It was shown from the experimental results that the collection efficiencies increased with increasing water injection rate and decreasing air velocity. Meanwhile, as for the particle size variation, all of the collection efficiency curves increased rapidly between 0.57-1.41${\mu}{\textrm}{m}$ for the range of water injection rate above 30 L/min. It was also seen that the collection efficiency of a packed wet scrubber is mainly governed by the mechanism of inertial impaction.