• 제목/요약/키워드: water flow path

검색결과 163건 처리시간 0.031초

밸브후단에서의 다회선 초음파 유량계의 특성변화 (Installation Effects on the Characteristics of Multi-path Ultrasonic Flowmeter with Valve)

  • 황상윤;서경호;김병찬;김경식;장학수
    • 유체기계공업학회:학술대회논문집
    • /
    • 유체기계공업학회 2000년도 유체기계 연구개발 발표회 논문집
    • /
    • pp.65-74
    • /
    • 2000
  • A five path ultrasonic and/or magnetic flowmeter were installed after valve. Five path ultrasonic flowmeter were tested to obtain it's performance in a water flow standard system and magnetic flowmeter. It's varied with straight pipe length(nD), install direction and valve position. All the results are summerized. The multi-path flowmeters(MUF) showed up to $\pm0.5{\%}$ at a 2, 4, 8, 15D spacing : the MUF was significantly better than magnetic flowmeter at disturbed flow conditions.

  • PDF

CFD-ACE를 이용한 연료 전지 냉각판의 최적 설계 (Optimization of Fuel-cell stack design using CFD-ACE)

  • 홍민성;김종민
    • 한국공작기계학회:학술대회논문집
    • /
    • 한국공작기계학회 2003년도 추계학술대회
    • /
    • pp.14-18
    • /
    • 2003
  • Feul-cell system consists of fuel reformer, stack and energy translator. Among these parts, slack is a core part which produces electricity directly. In order to set a stack module, fabrication of appropriate stack, design of water flow path in stack, and control of coolant are needed. Especially, water or air is used as a coolant to dissipate heat. The different temperature of each electric cells after cooling and the high temperature of the stack affect the performance of the stack, Therefore, it is necessary that the relationship between coolant, healing rate, width of slack, properties of stack, and the shape of water flow path must be understood. For the optimal design, the computational simulation by CFD-ACE has been conducted and the resulting database has been constructed.

  • PDF

배수경로 이질성에 의한 순간단위도 형상의 상대적 기여도 평가 (The assessment of the relative contribution of the shape of instantaneous unit hydrograph with heterogeneity of drainage path)

  • 최용준;김주철;김재한
    • 한국수자원학회논문집
    • /
    • 제42권11호
    • /
    • pp.897-909
    • /
    • 2009
  • 본 연구에서는 지리정보체계(GIS)의 격자 기반 GIUH 모형을 이용하여 배수경로의 이질성에 따른 지표면 유동과 하천망 유동의 상대적 기여도를 정량적으로 평가하였다. 대상유역은 국제수문개발계획(IHP)의 평창강, 보청천 및 위천 유역의 17개 소유역을 선정하였다. 각 대상유역에 대해 지표면과 하천의 배수경로길이에 대한 평균과 분산을 추정-분석하였다. 또한 관측 수문사상과 결합하여 GIUH 모형의 동적매개변수인 특성 유속을 지표면과 하천에 대해 산정하였다. 산정된 경로길이와 특성유속을 통해 유하시간의 분포, 즉 순간단위도의 평균 및 분산을 추정하여 배수경로의 이질성에 따른 각각의 기여도를 평가 하였다. 연구 결과 순간단위도의 형상을 결정하는 분산의 영향은 중소규모 유역(500 $km^2$이내)에서 지표면의 영향이 지배적이었다. 따라서 소규모 유역에서 GIUH 적용 시 지표면의 유동을 중요하게 고려해야 할 것이다.

상수도용 계량 밸브 임펠러 회전수에 따른 유동해석에 관한 연구 (A Study on the Flow Analysis According to Impeller Speed for City Water Supply Measuring Valve)

  • 김태준;이중섭;이치우
    • 한국산업융합학회 논문집
    • /
    • 제26권2_2호
    • /
    • pp.307-313
    • /
    • 2023
  • This study conducts the flow analysis on the basis of the impeller RPM of water metering valve. The software used for the flow analysis is STAR-CCM+. In terms of the structure of the metering valve, it has an impeller installed inside, and a metering chamber has inlet and outlet holes. The flow analysis on the water metering valve drew the following conclusions: Regarding the flow field in the valve, the impeller had the highest velocity distribution, and complex flow field was generated in the metering chamber. In particular, since the path between the inlet and outlet holes in the metering chamber and the valve body was narrow, there was a section that had flow field interference. The flow rate and flow coefficient distribution according to the impeller RPM were on the linear increase. Given that, it showed the feature of the valve used for water metering on the basis of the impeller RPM.

감천항의 해수유동 특성 (Flow Characteristics of Gamcheon Harbour)

  • 김기철;김재중;장필훈
    • 한국항만학회지
    • /
    • 제13권2호
    • /
    • pp.409-418
    • /
    • 1999
  • Gamcheon Bay has complicated and unique flow pattern which is affected by topography characteristics of a semi-closed bay and warm water discharge from the power plant located at the bay. It is very important to consider warm water discharge with tidal period and wind effects, which are mainly acting on the surface flow patterns in Gamcheon Bay. The results of observation show as follows; i) Because Gamcheon bay has much elongated shape to the north-south direction and narrow entrance with two separated breakwaters, the flow is very weak inside the bay. ii) The main flow path is at the west side of the bay. The direction of flood current is northward along the west side of the bay and the direction of ebb current is southward along the west side of the bay. The southward direction of warm water discharge has curved to the west side of the bay. iii)At the period of flood current for neap tide, the flow direction is southward in the bay, which is thought by the effects of warm water discharge. But at the bottom layer, the effects of tidal current reached to the middle of the bay, and showed features like eddy. iv) The wind effect is very strong, especially, prominent in the west and east side of the bay.

  • PDF

케비테이션 제트 유동을 이용한 발전 시스템 (A Power-Generation System using Cavitation jet flow)

  • 나정수;이강주;이봉렬;주남식
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2010년도 춘계학술대회 초록집
    • /
    • pp.162.1-162.1
    • /
    • 2010
  • Cavitation phenomenon has long been a difficult problem that regarded as negative event to fluid machines or industrial facilities. In the latest, however, some engineers became to understand the power of cavitation and use it to cleaning wall after developing cavitation nozzle. In this paper, we introduce new concept for power-generation system using cavitation jet flow maid by nozzle and impulse turbine in vacuum condition. The vacuum needed to make cavitation is generated naturally by Torricelli's vacuum, 10.23m effective head drop without additional power. We analyzed water's boiling and the steam's mean free path according to vacuum purity levels for nozzles and turbine blades. The nozzles make water accelerate in the neck and boil in expansion section of the nozzles. The shape of the impulse turbine is designed for absorption of the molecule's kinetic energy of the steam.

  • PDF

연료 전지 냉각판의 최적 설계 (A Study on the Optimization of Fuel-Cell Stack Design)

  • 홍민성;김종민
    • 한국공작기계학회논문집
    • /
    • 제12권6호
    • /
    • pp.92-96
    • /
    • 2003
  • Feul-Cell system consists of fuel reformer, stack and energy translator. Among these parts, stack is a core part which produces electricity directly. In order to set a stack module, fabrication of appropriate stack, design of water flow path in stack and control of coolant are needed. Especially, oater or air is used as a coolant to dissipate heat. The different temperature of each electric cell after cooling affects the performance of the stack. Therefore, it is necessary that the relationship between coolant hearing rate, width of stack, properties of stack, and the shape of water flow path must be understood. For the optimal design, the computational simulation by CFD-ACE has been conducted and the resulting database has been constructed.

증기발생기 급수링 관통손상 원인 및 영향 고찰 (Study on Cause and Effect of SG Feed Water Ring Through-Wall Hole)

  • 이성호;이요섭
    • 한국압력기기공학회 논문집
    • /
    • 제11권1호
    • /
    • pp.61-68
    • /
    • 2015
  • The function of Feed Water Ring is to provide the flow path from Feedwater Nozzle to inside of SG(steam generator). Significant amounts of general FAC on the outside of the Feed Water Ring are not likely due to the low flow velocities in this area. However, on the interior of the Feed Water Ring, there may be areas of local higher flow velocity which could lead to higher FAC rates. These may include the inlet tee from the Feedwater Nozzle into the Feed Water Ring, the areas where the Feed Water Ring changes diameter, and especially the entrance area to the J-Nozzles. In this paper, the results of root cause analysis of through-wall hole observed at domestic WH 51F SG Feed Water Ring and its effect on the integrity and performance of SG are described. And, the maintenance strategy for WH 51F SG Feed Water Ring and the monitoring strategy for Downcomer Feed Water Ring of CE System 80 SG are presented.

An Overall Investigation of Break Simulators for LOCA Scenarios in Integral Effect Tests

  • Kim, Yeon-Sik;Park, Hyun-Sik
    • 에너지공학
    • /
    • 제23권4호
    • /
    • pp.73-88
    • /
    • 2014
  • Various studies on the critical flow models for sub-cooled and/or saturated water were reviewed, especially on Fauske, Moody, and Henry for basic theoretical models; Zaloudek for insight into physical phenomena for a critical flow in an orifice type flow path; Sozzi & Sutherland for a critical flow test of saturated and sub-cooled water at high pressure for orifice and nozzles; and a Marviken test on a full-scale critical flow test. In addition, critical flow tests of sub-cooled water for the break simulators in integral effect test (IET) facilities were also investigated, and a hybrid concept using Moody's and Fauske's models was considered by the authors. In the comparison of the models for the selected test data, discussions of the effect of the diameters, predictions of the critical flow models, and design aspects of break simulator for SBLOCA scenarios in the IET facilities were presented. In the effect of diameter on the critical flow rate with respect to all dimensional scales, it was concluded that the effect of diameter was found irrespective of diameter sizes. In addition, the diameter effect on slip ratio affecting the critical flow rate was suggested. From a comparison of the critical flow models and selected test data, the Henry-Fauske model of the MARS-KS code was found to be the best model predicting the critical flow rate for the selected test data under study.

곡관후단의 직관거리와 센서위치에 따른 초음파유량계의 오차특성 (Error Characteristics of Clamp-on Ultrasonic Flowmeters Depending on Location of Sensors and Downstream Straight Run of Bent Pipe)

  • 이동근;조용
    • 대한기계학회논문집B
    • /
    • 제35권8호
    • /
    • pp.861-868
    • /
    • 2011
  • 관로를 통과하는 유체의 양을 측정하기 위해 설치된 유량계는 주기적인 교정과 비교측정을 통하여 측정의 정확도와 신뢰성을 확보하고 있다. 이때 사용되는 기준기는 휴대용 즉 센서가 관로의 외벽에 부착되는 건식 초음파유량계이며 사용되는 측정센서의 수량에 따라 1회선, 2회선, 4회선으로 구분된다. 본 연구의 대상은 K-water에서 주로 사용하고 있는 유량계를 선정한 후 직관거리가 충분히 확보된 상태에서 실험대상 유량계가 갖는 고유오차와 유동교란인자인 2중 곡관 후단에서의 직관거리별 오차에 대한 특성실험을 실시하였다. 실험결과를 기준으로 허용오차를 만족하는 센서위치 즉, 관로외부에 부착하는 각도와 곡관 후단으로부터의 이격거리 및 최적의 회선수를 제시하여 유량측정기술 향상을 통한 수처리 공정관리 및 유수율 제고기반을 마련하였다.