Analysis of Spatial Water Quality Variation in Daechung Reservoir (대청호 수리-수질의 공간적 변동 특성 분석)

  • Lee, Heung Soo;Chung, Se Woong;Choi, Jung Kyu;Oh, Dong Geun;Heo, Tae Young
    • Journal of Korean Society on Water Environment
    • /
    • v.27 no.5
    • /
    • pp.699-709
    • /
    • 2011
  • The uses of multi-dimensional hydrodynamic and water quality models are increasing to support a sustainable management of large dam reservoirs in Korea. Any modeling study requires selection of a proper spatial dimension of the model based on the characteristics of spatial variability of concerned simulation variables. For example, a laterally averaged two-dimensional (2D) model, which has been widely used in many large dam reservoirs in Korea, assumes that the lateral variations of hydrodynamic and water quality variables are negligible. However, there has been limited studies to give a justification of the assumption. The objectives of this study were to present the characteristics of spatial variations of water quality variables through intensive field monitoring in Daechung Reservoir, and provide information on a proper spatial dimension for different water quality parameters. The monitoring results showed that the lateral variations of water temperature are marginal, but those of DO, pH, and conductivity could be significant depending on the hydrological conditions and local algal biomass. In particular, the phytoplankton (Chl-a) and nutrient concentrations showed a significant lateral variation at R2 (Daejeongri) during low flow periods in 2008 possibly because of slow lateral mixing of tributary inflow from So-oak Stream and wind driven patchiness.

Prediction of Chlorophyll-a Changes due to Weir Constructions in the Nakdong River Using EFDC-WASP Modelling

  • Seo, Dong-Il;Kim, Min-Ae;Ahn, Jong-Ho
    • Environmental Engineering Research
    • /
    • v.17 no.2
    • /
    • pp.95-102
    • /
    • 2012
  • To evaluate the effect of the 4 major rivers restoration project in the Nakdong River to water quality of the river, the Environmental Fluid Dynamics Code (EFDC) and Water Quality Analysis Simulation Program (WASP), are applied in series. Results showed overall decrease in biochemical oxygen demand ($BOD_5$) concentrations and increase in chlorophyll-a concentrations, while total nitrogen and total phosphorous concentrations did not show significant changes, relatively. Decrease in $BOD_5$ concentrations seems to be influenced by an increased hydraulic residence time, which may allow more time for the degradation of organic material. Changes in Chlorophyll-a (Chl-a) concentration, due to the project were more significant for the upper stream areas that show relatively low Chl-a concentration ranges (less than 20 g/L). After the introduction of the Geumho River in the middle part of the Nakdong River, rapid growth of phytoplankton was observed. However, in this middle part of the Nakdong River, the ratio of Chl-a concentration change are less significant, compared to the upper stream areas, due to the project. In the lower stream area, Chl-a concentration decreased after the project. This seems to be resulted from the decreased light availability, due to increased depth, while the nutrient concentrations have been high enough to support phytoplankton growth.

Water-Quality Analysis for Gokgyo Stream in Chonan Asan Region and Pollution Source Control Strategy Using GIS (천안/아산권역내 곡교천의 수질분석 및 지리정보체계를 이용한 유역 오염원 관리방안에 관한 연구)

  • 황병기;이상호
    • Journal of Environmental Science International
    • /
    • v.9 no.6
    • /
    • pp.443-447
    • /
    • 2000
  • Chonan and Asan city have been a focal point due to rapid development as the first station for Express Railroad and key cities West Coast Development Region. Gokgyo stream adjacent to the cities plays an important role as a drainage channel for an agriculture and a discharger of urban storm water. Waster quality of the stream has been deteriorating caused by pollution sources such as a untreated wastewater discharge and runoff from the watershed. In the study, we conducted 4 surveys in April, May, July, and September to understand the current state of water quality for the stream and to make it possibe to predict future water-quality variation for future development. The system runs on a personal computer under the windows enviroment and provides extensive graphic user interface(GUI) for user-friendly assessment. Using the pull-down menus provided by the GUI panel, the user is able to operate the system by pointing and clicking the icon to identify the state of water-quality at locations concerned. Furthermore, we developed an integrated watershed management system. The constructed system could be a useful tool as a decesion maker for pollution source control strategy.

  • PDF

A Study on THMs Formation in Service Waters and Waste Waters at Kunsan (군산지역 용 . 폐수중의 THMs생성 및 배출에 관한 연구)

  • 황갑수;이영남;김강주;여성구;김진삼
    • Journal of Environmental Health Sciences
    • /
    • v.27 no.4
    • /
    • pp.41-46
    • /
    • 2001
  • Trihalomethane(THMs) levels in drinking tap water, indoor swimming pool water and industrial effluent in Kunsan area were surveyed in this study. During experimental period, the monthly averages of THMs in drinking tap water from Keumkang wide-area supply ranged from 15$\mu\textrm{g}$/ι/to 50 $\mu\textrm{g}$ showing the highest level in summer. 3 indoor swimming pools showed the monthly average levels of THMs formation ranging from 8$\mu\textrm{g}$/ι/to 20$\mu\textrm{g}$/ι and the pool under public management seemed to maintain its water quality more stable than those under private management THMs concentrations in the effluents. discharged from 10 manufacturing companies, ranged from N.D. to 95$\mu\textrm{g}$/ι and it was estimated that the overall THMs level discharged front those manufacturing companies is not high, reflecting the traces recorded for most effluents. The composition ratios of individual THMs for industrial effluents showed a difference from those for drinking water and swimming pool water, along with their wide variations according to the company and relatively high composition ratios of Br substituents.

  • PDF

A Study on the Application and Design Procedure of Multi-Purpose Wet Detention Ponds for Improving Water Quality - Case Study of NamAk New Town Development Area - (다목적 저류지의 수질개선을 위한 설계과정 및 적용에 관한 연구 - 남악 신도시 개발지를 대상으로 -)

  • Woo, Chang-Ho
    • Journal of the Korean Society of Environmental Restoration Technology
    • /
    • v.7 no.1
    • /
    • pp.97-109
    • /
    • 2004
  • The disposal of stormwater is one of the major problems in urban water management. One method of reducing peak runoff rates and other detrimental impacts of stormwater is detention storage. Detention ponds as a water quality control alternatives have been investigated by a number of researchers. Recognizing multiple roles such as flood peak attenuation, pollution removal and aesthetic enhancement, the design and management of detentions ponds deserve more research. The purpose of this research is to establish design criteria wet detention ponds to improve water quality. Water quality in detention pond discharge might be improve with physical, chemical and biological alterations. Physical alteration was focused in this study. There are several methods for estimating the suspended solid control capability of wet detention ponds. Existing models of suspended solids removal are based on sedimentation and gravity settling theory. The pollutant trap efficiency of pond is a function of several interrelating factors. Detention time is the most important factor, because it determine gravity settling quantities of pollutants. Desirable modification of physical factors for improvement of water quality in wet detention ponds are volume ratio, area ratio, length to width ratio, depth, out let location, bottom soil type. In order to apply design procedure in actual site, Namak new town development area was selected.

A Study on the Potable Water Purification System with Pre-Ozone and Ultra Filtration Membrane of Hollow Fiber Type (전오존과 중공사형 한외여과막을 이용한 간이정수처리시스템에 관한 연구)

  • Kim, Min-Kuk;Chun, Yang-Kun
    • Journal of Korean Society on Water Environment
    • /
    • v.21 no.2
    • /
    • pp.196-204
    • /
    • 2005
  • The objective of this study is to evaluate the possibility to apply pre-ozone and membrane system for drinking water. This system is improved in fouling control by pre-ozone system. It is composed of ultrafiltration hollow fiber type membrane and ozone reactor. The result of this study is that the flux is increased about 10.7% and decreased in TMP by the pre-ozone. Also, backwashing pressure decreased about 18%. The optimum concentration of residual ozone is 0.3~0.5 ppm. During the period, the recovery ratio of this system was turned out to be 90% as the flowrate of effluent is $67.1m^3/day$. When the TMP and backwashing pressure was $0.85kg/cm^2$ and $1.10kg/cm^2$, this system was stable without sudden fouling. Finally, the quality of effluent is satisfied the guidelines for potable water quality such as turbidity, color, E.coli, Mn, Al, Fe and so on.

Modeling the Relationship between Land Cover and River Water Quality in the Yamaguchi Prefecture of Japan

  • Amiri, Bahman Jabbarian;Nakane, Kaneyuki
    • Journal of Ecology and Environment
    • /
    • v.29 no.4
    • /
    • pp.343-352
    • /
    • 2006
  • This study investigated the relationship between land cover and the water quality variables in the rivers, which are located in the Yamaguchi prefecture of West Japan. The study area included 12 catchments covering $5,809\;Km^2$. pH, dissolved oxygen, suspended solid, E. coli, total nitrogen and total phosphorus were considered as river water quality variables. Satellite data was applied to generate land cover map. For linking alterations in land cover (at whole catchment and buffer zone levels) and the river water quality variables, multiple regression modeling was applied. The results indicated that non-spatial attribute (%) of land cover types (at whole catchment level) consistently explained high amounts of variation in biological oxygen demand (72%), suspended solid (72%) and total nitrogen (87%). At buffer zone-scale, multiple regression models that were developed to represent the linkage between the alterations of land cover and the river water quality variables could also explain high level of total variations in suspended solid (86%) and total nitrogen (91%).

Bench-scale Experiment on Catalytic Decomposition of 1,2 Dichlorobenzene by Vanadia-Titania Catalyst

  • Jeong, Ju-Young;Chin, Sung-Min;Jurng, Jong-Soo
    • Journal of Environmental Science International
    • /
    • v.18 no.7
    • /
    • pp.709-714
    • /
    • 2009
  • Catalytic activities of $V_2O_5/TiO_2$ catalyst were investigated under reaction conditions such as reaction temperature, catalyst size, inlet concentration and space velocity. A 1,2-dichlorobenzene(1,2-DCB) concentrations were measured in front and after of the heated $V_2O_5/TiO_2$ catalyst bed, and conversion efficiency of 1,2-DCB was determined from it's concentration difference. The conversion of 1,2-DCB using a pellet type catalyst in the bench-scale reactor was lower than that with the powder type used in the micro flow-scale reactor. However, when the pellet size was halved, the conversion was similar to that with the powder type catalyst. The highest conversion was shown with an inlet concentration of 100 ppmv, but when the concentration was higher or lower than 100 ppmv, the conversion was found to decrease. Complete conversion was obtained when the GHSV was maintained at below 10,000 $h^{-1}$, even at the relatively low temperature of $250^{\circ}C$. Water vapor inhibited the conversion of 1,2-DCB, which was suspected to be due to the competitive adsorption between the reactant and water for active sites.

Emergy Cost-Benefit Evaluation of the Down Stream of Nakdong River Using Environmental-Ecological Concept (환경 생태학적 개념을 이용한 낙동강 하류의 에머지 비용-편익 평가)

  • Jung, Hwa-Sook;Lee, Seog-Mo;Son, Hyeng-Sik;Son, Hee-Jong
    • Journal of Environmental Science International
    • /
    • v.22 no.4
    • /
    • pp.507-514
    • /
    • 2013
  • The Nakdong River being used as drinking water sources for the Busan metropolitan city has the vulnerability of water management due to the fact that industrial areas are located in the upper Nakdong River. This study used emergy analysis method to evaluate ecological-economics of water treatment systems of D water treatment plant (WTP) where located in the downstream of the Nakdong River. The emergy methodology is a system evaluation tool that uses energy as the common currency to compare different resources on a common basis. Emergy yield ratio (EYR) and emergy sustainability index (EmSI) of D WTP were 1.16 and 0.18, respectively. It means not resources and sustainable system but consumer goods and not sustainable system. Ratio of emergy benefit to the purchaser (EBP) shows 2.7 times higher than economic costs. To change the weak water source and situations we need to diversity water intake.

Studies on Environmental Impact of Pulp and Addtives in Liner Papermaking

  • Seo, Jin-Ho;Kim, Hyoung-Jin
    • Proceedings of the Korea Technical Association of the Pulp and Paper Industry Conference
    • /
    • 2006.06b
    • /
    • pp.441-444
    • /
    • 2006
  • A lot of water is using in the paper mill for dilution, washing, sealing, and other process operation. As the regulation of water environment has been more tightened than ever before, water management in the paper mill becomes the most important task. Topics on reducing fresh water and increasing recycling water have been studied. Further, an interest in zero-effluent system has been increased. The pH of waste water in paper mill is usually weak acidic or neutral. The waste water in the paper mill includes water insoluble organic materials that are not easy to be dissolved in the water, inorganic materials that never react with water and chemical additives that are used to recycled fiber. This study investigated on the effect of various materials used in paper mill on COD. This data could be used to control the environmental load in paper mill. COD caused by raw materials and NBDCOD (Non Bio Degradable COD) after the activated sludge process are investigated in this study. Results obtained in this study can be used in a simulation program designed to control environmental load in the paper mill.

  • PDF