• Title/Summary/Keyword: water dynamics

Search Result 1,360, Processing Time 0.029 seconds

Visualization Study on Microscale Wetting Dynamics of Water Droplets on Dry and Wet Hydrophilic Membranes

  • Park, Kyungjin;Kim, Seong Yeon;Hong, Jiwoo;Kim, Jong Hyun;Lim, Geunbae
    • Korean Chemical Engineering Research
    • /
    • 제60권2호
    • /
    • pp.277-281
    • /
    • 2022
  • The wetting dynamics of water droplets dispensed on the surface of dry and wet hydrophilic membranes were investigated experimentally from a microscale point of view. By using a high-speed, white-beam x-ray microimaging (WXMI) synchrotron, consecutive images displaying the dynamic motions of the droplets were acquired. Through analyzing the characteristics observed, it was found that the dry hydrophilic membrane showed local hydrophobicity at a certain point during the absorption process with apparent contact angles greater than 90. While on the other hand, the apparent contact angles of a water droplet absorbing into the wet membrane remained less than 90 and showed total hydrophilicity. The observations and interpretation of characteristics that affect the contact, wetting, recoiling, and dynamic behaviors of droplets are significant for controlling liquid droplet impingement in a desired manner.

공업용수 공급시스템의 효율적인 운영을 위한 시스템다이내믹스 모형의 개발 (Development of a System Dynamics Computer Model for Efficient Operations of an Industrial Water Supply System)

  • 김봉재;박수완;김태영;전대훈
    • 상하수도학회지
    • /
    • 제26권3호
    • /
    • pp.383-397
    • /
    • 2012
  • In this study, a System Dynamics (SD) simulation model for the efficient operations of an industrial water supply system was developed by investigating the feedback loop mechanisms involved in the operations of the system. The system was modeled so that as demand is determined the water supply quantity of intake pumping stations and dams are allocated. The main feedback loop showed that many variables such as the combinations of pump operation, unit electric power(kWh/$m^3$), unit electric power costs(won/$m^3$), water level of water way tunnel, suction pressure and discharge of pumping station, and tank and service reservoir water level had causal effects and produced results depending on their causal relationship. The configurations of the model included an intake pumping station model, water way tunnel model, pumping station model (including the tank and service reservoir water level control model), and unit electric power model. The model was verified using the data from the case study industrial water supply system that consisted of a water treatment plant, two pumping stations and four dams with an annual energy costs of 5 billion won. It was shown that the electric power costs could have been saved 7~26% during the past six years if the operations had been based on the findings of this study.

2D 유한요소 해석을 통한 Water injection pump의 동특성 분석 (Analysis of dynamics characteristics of water injection pump through the 2D finite element)

  • 이종명;김용휘;김준호;최현철;최병근
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2014년도 춘계학술대회 논문집
    • /
    • pp.408-414
    • /
    • 2014
  • After drilling operations at the offshore plant to production to crude oil to high pressure. After that time the low pressured of pipe inside when the secondary produce so oil recovery is reduced. At that time injection sea water at the pipe inside through water injection pump that the device Increase recovery so to be research and development at many industry. So developing 3-stage water injection pump at the domestic company. A variety of mathematical analysis during the detailed design analysis was not made through the dynamics characteristic. In this paper, a 2D finite element analysis is performed through the dynamics of the present study was the validation of the model.

  • PDF

어류 차단 스크린 설치에 따른 안동-임하호 연결터널 내 흐름변화에 대한 전산유체동역학 수치모의 (Computational Fluid Dynamics Simulation of Flow Pattern Change in the Andong-Imha Reservoir Connecting Tunnel Due to Fish Exclusion Screens)

  • 안상도
    • 한국물환경학회지
    • /
    • 제30권5호
    • /
    • pp.477-485
    • /
    • 2014
  • Imha Reservoir is connected to Andong Reservoir via a diversion tunnel allowing water to pass between. The diversion tunnel is equipped with screens to exclude exotic largemouth bass due to their predatory impacts on prey assemblages resulting in a degradation of species richness of local fish fauna and extinction of local fish populations in Korea. Flow pattern changes resulting from the fish screens and trash racks were investigated using a computational fluid dynamics (CFD) model. Numerical simulations showed that the decrease in the discharge capacity of the tunnel is approximately 8.6% and the headloss coefficient for fish screen at Andong intake tower was determined to be 1.5. In order not to allow the small fishes enough to pass through the wire openings enter into Imha Reservoir through tunnel, the velocity in the tunnel should be greater than 1.48 m/s which is a critical ascending velocity of the bass. This study suggests that it can keep the velocity higher enough to exclude largemouth bass when a gate opens with the condition of 1.0m difference in water stage between two reservoirs.

시스템 다이내믹스를 이용한 농업용수 재이용시스템 경제성 분석 (Economic Analysis of Wastewater Reuse Systems for Agricultural Irrigation using a System Dynamics Approach)

  • 정한석;서교;장태일;성충현;김학관;박승우
    • 한국농공학회논문집
    • /
    • 제55권2호
    • /
    • pp.9-20
    • /
    • 2013
  • Many studies have reported additional treatment is needed to use wastewater for agricultural purpose. Economic considerations should be taken into account to establish infrastructure for agricultural reuse because of a large amount of water use in irrigation and relatively low water quality requirement. The objective of this study was to conduct economic analysis of wastewater reclamation and reuse systems for agriculture. A system dynamics approach considering complexity and dynamics in the wastewater reuse systems was used for the economic analysis, which are related with social, environmental, and economic problems. Sensitivity and benefit cost analysis for wastewater reuse systems was conducted through the established economic assessment model. The result of sensitivity analysis showed that water resources development and installation cost were the most sensitive for total benefits and costs, respectively. The scenario-based test of the organized economic assessment model shows marginal cost ranges and enables decision-makers to decide reasonable cost for the wastewater reuse systems for agriculture.

시스템 다이나믹스를 이용한 투명성의 수도사업에 대한 영향 분석 (Analyzing Effects of Transparency on a Water Business Case Using System Dynamics)

  • 이상은;김현옥;박희경
    • 상하수도학회지
    • /
    • 제20권4호
    • /
    • pp.605-616
    • /
    • 2006
  • This study focused on analyzing effects of transparency on the water system specifically and quantitatively. It was observed that transparency can give a water utility considerable motives for improving its performance and make the service price meet the production cost. System simulation made sure that these functions of transparency will eventually result in the better service for customers and the more favorable finance for a water utility. Results of this study can help some decision makers and utilities to sort out positive countermeasure for improving transparency.

A comparison of destructive behaviors of distilled water, salty water, sulfuric acid and heat on glass/vinyl ester composites

  • Asli, S.A.;Shokrieh, M.M.;Kamangar, M.A.
    • Composite Materials and Engineering
    • /
    • 제3권3호
    • /
    • pp.167-178
    • /
    • 2021
  • In the present paper, the destructive behavior of distilled water, salty water, sulfuric acid, and heat on glass/vinyl ester composites was investigated by experimental methods. Hetron 922 vinyl ester resin and two types of mat and woven glass fibers as the reinforcements were used to fabricate composite test samples. All samples were immersed in distilled water, salty water, and sulfuric acid with three different concentrations. The tests were performed at 20℃ and 70℃ for the exposure duration of 1, 2, 4, and 8 weeks. Bending tests were performed after aging for all composite samples to check the degradation of the bending modulus and strength. The results show that the effect of distilled water, in comparison with salty water, on the degradation of composite samples was significant. On the other hand, almost non-sensitivity of concentrations of salty water on the weight gain of specimens has been observed. In addition, it was also observed that the degradation of samples at 70℃ temperature is much more than that of at 20℃. Also, it was observed that the flexural modulus of virgin specimens exposed to salty water (2% concentration) has been recovered just after two weeks of immersion. Furthermore, in some cases, composite samples under the sulfuric acid solution have lost almost 80% of their mechanical properties.

인공호소인 영산호의 용존산소 분포와 수층 성층구조의 연관성 분석 (Exploring the Dynamics of Dissolved Oxygen and Vertical Density Structure of Water Column in the Youngsan Lake)

  • 송은숙;조기안;신용식
    • 한국환경과학회지
    • /
    • 제24권2호
    • /
    • pp.163-174
    • /
    • 2015
  • The Youngsan Lake was constructed to supply agricultural water to the extensive rice fields in the basin of the lake in 1981. Hypoxia has often developed in the bottom water of the lake during the warm season although the water depth is relatively shallow (< 16 m). We investigated the spatial and temporal variations of dissolved oxygen (DO) and physical properties such as water temperature, salinity and turbidity to elucidate the effects of change in physical properties on DO dynamics in the lake. Vertical profiles of DO, temperature, salinity, and water density were also explored to verify the development of stratification in relation to DO variation in the water column. Hypoxia (DO < $2mg\;L^{-1}$) was not observed in the upper regions whereas hypoxia was detected in the lower regions during the warm season. Thermocline generally developed in the lower regions during the warm season unlike the previous studies in which no thermocline was observed. However, water column was well mixed when freshwater water was discharged from the reservoir through the sluice gate of the dike. DO concentrations also decreased when halocline or pycnocline developed during the dry season suggesting that the vertical stratification of water column affects DO dynamics although the water depth is shallow in the Youngsan lake.

GDL을 고려한 고분자전해질형 연료전지 모사 단위 유로 채널에서의 물방울 유동 특성에 대한 실험적인 고찰 (Experimental Investigation of the Water Droplet Dynamics inside the Simulated PEMFC Single Flow Channel with GDL)

  • 김한상;지용휘;인지헌;안지용
    • 한국수소및신에너지학회논문집
    • /
    • 제24권1호
    • /
    • pp.76-83
    • /
    • 2013
  • Polymer electrolyte membrane fuel cells (PEMFCs) are regarded as a promising alternative to replace the existing automotive power sources. To get high performance and long-term durability for PEMFC systems, novel water management is essential. To this end, a comprehensive understanding of dynamics of the liquid water droplets within an operating PEMFC plays an important role. In this work, direct visualization of dynamic behaviors of the water droplet in the ex situ unit flow channel of a PEMFC including gas diffusion layer (GDL) is carried out as one of the fundamental studies for novel water management. Water droplet dynamics such as the movement and growth of liquid water droplets are mainly presented. Effects of GDL characteristics and inlet air flow rate on the water droplet transport and its removal from the flow channel are also discussed. The data obtained in this study can contribute to build up the fundamental operating strategy including balanced water removal capacity for automotive PEMFC systems.