• Title/Summary/Keyword: water deficiency

Search Result 294, Processing Time 0.036 seconds

Optimal Reservoir Operation Models for Paddy Rice Irrigation with Weather Forecasts(Ill) -Model Application- (기상예보를 고려한 관개용 저수지의 최적 조작 모형(III) -모형의 적용-)

  • 김병진;박승우;정하우
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.36 no.3
    • /
    • pp.47-59
    • /
    • 1994
  • The irrigation reservoir operation models developed were tested with weather and field data, and the sensitivity of the water requirement deficiency indices(WRDI) were checked with different initial reservoir storages, irrigated areas, and other water uses from the reservoir storage. Seven reservoir release rules were applied to Yongseol Reservoir. Twenty year WRDIs were computed to check performances of those reservoir release rules. Mean WRDIs were 138, 198, 198, 200, 240, 344, and 1033mm for ROM, TOS, COS, CRR, MSC, FAS, and SRC, respectively. The results indicated that ROM contributes consistently to higher operation efficiencies of an irrigation reservoir. The test results of LFROM and SFROM showed that reservoir operation with the proposed optimization technique ROM would be better suited for an irrigation district than those with the other rules. And the proposed model could be used as a tool to improve reservoir operations.

  • PDF

Development of Heat Wave Indices for Korean Peninsula

  • Chandrasekara, Sewwandhi S.K.;Kwon, Hyun-Han
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2020.06a
    • /
    • pp.366-366
    • /
    • 2020
  • The drought is one of the extreme natural disasters observed in any climate zone and it is due to the deficiency in moisture. The flash drought is identified recently as a subdivision of drought and it is an extreme event distinguished by sudden onset and rapid intensification of drought conditions with severe impacts. The main cause for the flash drought is coupled situation due to precipitation deficit and high evapotranspiration. Hence, heat waves plays major role in identification of flash drought. Therefore, this study focused on identifying changes in distribution of heat waves for Korean Peninsula. The daily maximum and minimum temperature data were used in this study. The heat wave, heat wave intensity and heat wave intensity index were derived. The results of the study would be an input for the future studies on identification of flash drought in Korean Peninsula.

  • PDF

SPECTRAL ANALYSIS OF WATER-STRESSED FOREST CANOPY USING EO-l HYPERION DATA

  • Kook Min-Jung;Shin Jung-Il;Lee Kyu-Sung
    • Proceedings of the KSRS Conference
    • /
    • 2005.10a
    • /
    • pp.7-10
    • /
    • 2005
  • Plant water deficiency during drought season causes physiological stress and can be a critical indicator of forest fire vulnerability. In this study, we attempt to analyze the spectral characteristics of water stressed vegetation by using the laboratory measurement on leaf samples and the canopy reflectance spectra extracted from satellite hyperspectral image data. Leaf-level reflectance spectra were measured by varying moisture content using a portable spectro-radiometer. Canopy reflectance spectra of sample forest stands of two primary species (pine and oak) located in central part of the Korean peninsula were extracted from EO-l Hyperion imaging spectrometer data obtained during the drought season in 2001 and the normal precipitation year in 2002. The preliminary analysis on the reflectance spectra shows that the spectral characteristics of leaf samples are not compatible with the ones obtained from canopy level. Although moisture content of vegetation can be influential to the radiant flux reflected from leaf-level, it may not be very straightforward to obtain the spectral characteristics that are directly related to the level of canopy moisture content. Canopy spectra form forest stands can be varied by structural variables (such as LAt, percent coverage, and biomass) other than canopy moisture content.

  • PDF

Analysis of 2-Dimensional Shallow Water Equations Using Multigrid Method and Coordinate Transformation

  • Lee, Jong-Seol;Cho, Won-Cheol
    • International Union of Geodesy and Geophysics Korean Journal of Geophysical Research
    • /
    • v.26 no.1
    • /
    • pp.1-14
    • /
    • 1998
  • Various numerical methods for the two dimensional shallow water equations have been applied to the problems of flood routing, tidal circulation, storm surges, and atmospheric circulation. These methods are often based on the Alternating Direction Implicity(ADI) method. However, the ADI method results in inaccuracies for large time steps when dealing with a complex geometry or bathymetry. Since this method reduces the performance considerably, a fully implicit method developed by Wilders et al. (1998) is used to improve the accuracy for a large time step. Finite Difference Methods are defined on a rectangular grid. Two drawbacks of this type of grid are that grid refinement is not possibile locally and that the physical boundary is sometimes poorly represented by the numerical model boundary. Because of the second deficiency several purely numerical boundary effects can be involved. A boundary fitted curvilinear coordinate transformation is used to reduce these difficulties. It the curvilinear coordinate transformation is used to reduce these difficulties. If the coordinate transformation is orthogonal then the transformed shallow water equations are similar to the original equations. Therefore, an orthogonal coorinate transformation is used for defining coordinate system. A multigrid (MG) method is widely used to accelerate the convergence in the numerical methods. In this study, a technique using a MG method is proposed to reduce the computing time and to improve the accuracy for the orthogonal to reduce the computing time and to improve the accuracy for the orthogonal grid generation and the solutions of the shallow water equations.

  • PDF

Long Term Affecting Factors on Major Water Quality Items of Landfill Leachate (매립장 침출수 주요 수질항목에 대한 장기 영향요소)

  • Chun, Seung-Kyu;Kim, Min Hyuk;Won, Jong Chul
    • Journal of Soil and Groundwater Environment
    • /
    • v.26 no.1
    • /
    • pp.24-33
    • /
    • 2021
  • Analysis of long term affecting factors on water quality items of gas emission form (BOD, COD) and leachate emission form (T-N, non-bio-degradable COD (NBDCOD)) was performed for the SUDOKWON 1st Landfill Site (LS1) and 2nd Landfill Site (LS2). As landfill gas was generated, BOD and COD decreased from 6,887 and 20,025 mg/L in 1993 to 49.5 and 670.2 mg/L in 2019, respectively. TN and NBDCOD increased with waste decomposition but gradually decreased after landfill closure because of the precipitation infiltration effect. Due to the drastic decline of carbon in the leachate, the BOD/TN ratios of LS1 and LS2 declined from 13.0 and 17.0 during early stage of the landfill to 0.07 and 0.16 in 2019, respectively; LS2 and NBDCOD/COD increased from 0.25 to 0.65 during the same period. These conditions caused carbon deficiency in denitrification treatment and a chemical post-treatment request for NBDCOD. The different behaviors of gas emission and leachate emission items suggest the necessity of different strategic approaches in the long term perspective.

Wireless safety monitoring of a water pipeline construction site using LoRa communication

  • Lee, Sahyeon;Gil, Sang-Kyun;Cho, Soojin;Shin, Sung Woo;Sim, Sung-Han
    • Smart Structures and Systems
    • /
    • v.30 no.5
    • /
    • pp.433-446
    • /
    • 2022
  • Despite efforts to reduce unexpected accidents at confined construction sites, choking accidents continue to occur. Because of the poorly ventilated atmosphere, particularly in long, confined underground spaces, workers are subject to dangerous working conditions despite the use of artificial ventilation. Moreover, the traditional monitoring methods of using portable gas detectors place safety inspectors in direct contact with hazardous conditions. In this study, a long-range (LoRa)-based wireless safety monitoring system that features the network organization, fault-tolerant, power management, and a graphical user interface (GUI) was developed for underground construction sites. The LoRa wireless data communication system was adopted to detect hazardous gases and oxygen deficiency within a confined underground space with adjustable communication range and low power consumption. Fault tolerance based on the mapping information of the entire wireless sensor network was particularly implemented to ensure the reliable operation of the monitoring system. Moreover, a sleep mode was implemented for the efficient power management. The GUI was also developed to control the entire safety-monitoring system and to manage the measured data. The developed safety-monitoring system was validated in an indoor testing and at two full-scale water pipeline construction sites.

Occurrence of Perchlorate in Drinking Water in Korea (국내 주요 정수장 수돗물의 퍼클로레이트 검출현황)

  • Kim, Hyun-koo;Kim, Joung-hwa;Lee, Youn-hee
    • Journal of Korean Society on Water Environment
    • /
    • v.23 no.6
    • /
    • pp.822-828
    • /
    • 2007
  • Perchlorate is an unregulated contaminant but recently many cases of perchlorate contamination have been reported in the US. In Japan, also, a couple of contamination incidents caused by perchlorate occurred. Against this backdrop, investigation on perchlorate was urgent for Korea. Accordingly, perchlorate investigation in tap water and river water was conducted one time a week for seven consecutive weeks at major water sources of Korea including Han River, Guem River, Yeong-san River, and Nak-dong River. Perchlorate was not found at Han River, Guem River, and Yeong-san River. However, all the 4 tap water samples in Nak-dong River recorded high level of perchlorate. Among others, NT1 located at Daegu posted the highest value of $22.3{\mu}g/L$. This level is lower than $24.5{\mu}g/L$, the threshold recommended by US EPA. Still, perchlorate contamination in drinking water can deal a heavy blow to nerve development of infants and children by causing iodine deficiency. At the 1st and 2nd investigations, perchlorate concentration reached $18.7{\sim}95.6{\mu}g/L$ and $4.0{\sim}25.6{\mu}g/L$ respectively, both of which are relatively higher. The high perchlorate concentration in Nak-dong River was possible because of the waste water discharged from LCD manufacturing factory which was located at NS3 in Gumi, Korea. Perchlorate concentration of waste water from the factory was $730{\sim}1,858{\mu}g/L$.

Water and Sodium Balance of Body Fluid (체액의 수분 및 나트륨 균형)

  • Kim, Ji-Hong
    • Childhood Kidney Diseases
    • /
    • v.14 no.2
    • /
    • pp.111-119
    • /
    • 2010
  • The maintenance of the osmolality of body fluids within a very narrow physiologic range is possible by water balance mechanisms that control the intake and excretion of water. Main factors of this process are the thirst and antidiuretic hormon arginine vasopressin (AVP), secretion regulated by osmoreceptors in the hypothalamus. Body water is the primary determinant of the osmolality of the extracellular fluid (ECF), disorders of body water homeostasis can be divided into hypo-osmolar disorders, in which there is an excess of body water relative to body solute, and hyperosmolar disorders, in which there is a deficiency of body water relative to body solute. The sodium is the predominant cation in ECF and the volume of ECF is directly proportional to the content of sodium in the body. Disorders of sodium balance, therefore, may be viewed as disorders of ECF volume. This reviews addresses the regulatory mechanisms underlying water and sodium metabolism, the two major determinants of body fluid homeostasis for a good understanding of the pathophysiology and proper management of disorders with disruption of water and sodium balance.

Growth, Deficiency Symptom and Tissue Nutrient Contents of Leaf Perilla (Perilla frutesens Britt) Influenced by Phosphorus Concentrations in Fertigation Solution (인산 시비농도가 잎들깨의 생육, 결핍증상 및 무기원소 함량에 미치는 영향)

  • Choi, Jong-Myung;Park, Jong-Yoon
    • Journal of Bio-Environment Control
    • /
    • v.16 no.4
    • /
    • pp.358-364
    • /
    • 2007
  • This study was carried out to investigate the effect of phosphorus concentrations in fertilizer solution on growth and development of nutrient deficiency in leaf perilla (Perilla frutesens). The nutrient concentrations in above ground plant tissue, petiole sap and soil solution of root media were also determined. Phosphorus deficiency resulted in a slow growth, lustreless leaves, suffused purple tining in older leaves and falling prematurely. Elevation of P concentrations in fertilizer solution increased the crop growth at 75 days after transplanting. The fresh weight in 0, 0.5 and 4.0 mM treatments were 0.48 g, 9.28 g, and 25.5 g, respectively, and dry weights were 0.06 g, 1.46 g and 4.13 g, respectively. The P concentrations in above ground plant tissue and petiole sap in 4.0 mM treatment were 1.78% and $2.040mg{\cdot}kg^{-1}$, respectively, at 75 days after transplanting. The soil P concentration in 4.0 mM treatment was $1.26mg{\cdot}kg^{-1}$ when it was determined by the 1:2 (sample:water) method. These results indicated that P concentrations higher than 0.3% in above ground plant tissue, $900mg{\cdot}kg^{-1}$ in petiole sap, and $0.57mg{\cdot}kg^{-1}$ in soil solution should be maintained to ensure proper growth of leaf perilla (Perilla frutesens).

Effect of Corni Fructus on Testosterone Deficiency Syndrome in In vitro and In vivo (In-vitro와 In-vivo에서 산수유의 남성갱년기 개선효과)

  • Kim, Tae Muk;Jung, Ho Kyung;Jang, Ji Hun;Sim, Mi Ok;Lee, Mu Jin;Cho, Jung Hee;Cho, Hyun Woo
    • Korean Journal of Pharmacognosy
    • /
    • v.47 no.3
    • /
    • pp.264-272
    • /
    • 2016
  • This study was carried out to evaluate the preventive effect of the Corni Fructus (SSU) 50 % EtOH extract (SSU-E50) against bisphenol A (BPA) toxicity in Leydig cells and improving testosterone deficiency syndrome in orchidectomized Sprague-Dawly (SD) rats. Antioxidant properties were measured by radical scavenging activity of SSU-E50 in ABTS assay and DPPH assay. Also, real-time polymerase chain reaction(real-time PCR) was performed to quantify the mRNA expression levels of antioxidant enzyme. SD rats were divided into eight group: normal, sham operation (Sham), orchidectomized (ORX), ORX treated with testosterone 1 mg/kg (Tes. 1), ORX treated with SSU water extract 100 mg/kg (SSU-A 100) and 300 mg/kg (SSU-A 300), ORX treated with SSU 50 % EtOH extract 100 mg/kg (SSU-E 100) and 300 mg/kg (SSU-E 300). On a comparative basis, the SSU showed better activity quenching ABTS with an IC50 value of 0.29 mg/ml and DPPH with an IC50 value of 0.33 mg/ml. Cell viability was evaluated by MTS assay as described not cytotoxic at the highest concentration of $500{\mu}g/ml$. Cytotoxicity of BPA showed in $200{\mu}M$, but definitely survived by treatment with SSU in Leydig cells. In addition, SSU increased the mRNA expression levels of antioxidant enzyme in BPA induced Leydig cells. Superoxide dismutase (SOD) level was slightly increased and malondialdehyde (MDA) level was decreased with SSU-A 100 in in-vivo. These results suggest that Corni Fructus extracts have the greatest property as a natural anti-oxidative and improves testosterone deficiency syndrome source.