• 제목/요약/키워드: water cycle management

검색결과 291건 처리시간 0.036초

산림생태계 수자원 공급서비스 계량화 모형의 국내적용성 분석 (Applicability Analysis of Water Provisioning Services Quantification Models of Forest Ecosystem)

  • 최현아;이우균;송철호;이종열;전성우;김준순
    • 한국환경복원기술학회지
    • /
    • 제17권4호
    • /
    • pp.1-15
    • /
    • 2014
  • Forest ecosystems generate variety of important goods and services for human well-being. As a growing concern of climate change and water shortage, it is necessary to quantify, model and map water balance in forest. In this study, we have analyzed 11 overseas forest water supply models (AIM, ATEAM, CENTURY, (E)SWAT, GUMBO, InVEST, PLM, SAVANNA, WaSSI, WaterGAP, WBM) and compared their scale, input and out data, availability of the models and analyzed the applicability of the models to Korea. As a result, InVEST and WaterGAP model appeared to be applicable for quantifying water provisioning services in Korea. A systematic approach for applying to evaluate water balance in forest was suggested based on our quantification approach.

과학적 물관리를 위한 ICT기반 실시간 수문정보시스템 구현 (Implementation of ICT-based Real-time Hydrological Data Acquisition and Processing System for Scientific Water Management)

  • 장성원;정창욱;조경훈;신지수
    • 한국정보통신학회:학술대회논문집
    • /
    • 한국정보통신학회 2022년도 춘계학술대회
    • /
    • pp.303-305
    • /
    • 2022
  • 우리나라는 지형학적, 수문학적 특성상 연중편차가 심한 물순환 특성을 보이고 있고, 최근에는 지구온난화와 기상이변 등으로 인해 수문현상의 변동성이 더욱 커지고 있다. 따라서 홍수, 가뭄 등 수문현상을 신속하게 파악하고 대비하기 위해서는 최신 ICT 기술을 융합한 과학적인 물관리의 필요성이 커지고 있다. 이에 K-water는 인공위성을 통해 실시간으로 수집하고 있는 수문자료와 GIS, CCTV를 연계하여 현장의 상황을 보다 직관적으로 확인할 수 있는 실시간 수문정보시스템(HDAPS : Hydrological Data Acquisition and Processing System)을 운영하여 홍수와 가뭄에 대비하고 있다. 본 논문에서는 K-water의 실시간 수문정보시스템을 소개하고 국민의 생명과 재산을 보호하기 위한 활용방안을 고찰해 보고자 한다.

  • PDF

LID 시범단지 설계절차 제시 및 빗물관리용량 산정 (Presentation of the Design Process and Capacity Estimation of Rainwater Management for LID Pilot Project)

  • 정종석;김경진
    • 토지주택연구
    • /
    • 제9권3호
    • /
    • pp.19-27
    • /
    • 2018
  • 도시재생 사업이 한창이다. 도시재생 사업이 순환형의 지속가능 개발이 되기 위해서는 빗물순환 복원이 필수적이다. 즉, 도시재생 사업에서의 LID 설계 프로세스가 필요하다. 먼저 기존 LID 설계 과정을 조사, 분석하였다. 기존 LID 설계는 현장의 특성과 빗물 흐름에 대한 고려가 부족하여 적절한 LID 시설 선정에 많은 제한이 있었다. 기존 설계 과정의 한계를 해결하기 위해 GIS를 이용한 수계분석이 필요하고, 빗물 흐름을 고려하는 LID 시설 설치가 중요하다. 또한, 본 연구는 토지주택연구원을 대상으로 LID 시범단지 사업을 수행하는 과정에서 발생한 사항들을 정리, 분석함으로써 도시재생 사업에 적용할 수 있는 방안을 제시하였다.

A Reduced-Boron OPR1000 Core Based on the BigT Burnable Absorber

  • Yu, Hwanyeal;Yahya, Mohd-Syukri;Kim, Yonghee
    • Nuclear Engineering and Technology
    • /
    • 제48권2호
    • /
    • pp.318-329
    • /
    • 2016
  • Reducing critical boron concentration in a commercial pressurized water reactor core offers many advantages in view of safety and economics. This paper presents a preliminary investigation of a reduced-boron pressurized water reactor core to achieve a clearly negative moderator temperature coefficient at hot zero power using the newly-proposed "Burnable absorber-Integrated Guide Thimble" (BigT) absorbers. The reference core is based on a commercial OPR1000 equilibrium configuration. The reduced-boron ORP1000 configuration was determined by simply replacing commercial gadolinia-based burnable absorbers with the optimized BigT-loaded design. The equilibrium cores in this study were directly searched via repetitive Monte Carlo depletion calculations until convergence. The results demonstrate that, with the same fuel management scheme as in the reference core, application of the BigT absorbers can effectively reduce the critical boron concentration at the beginning of cycle by about 65 ppm. More crucially, the analyses indicate promising potential of the reduced-boron OPR1000 core with the BigT absorbers, as its moderator temperature coefficient at the beginning of cycle is clearly more negative and all other vital neutronic parameters are within practical safety limits. All simulations were completed using the Monte Carlo Serpent code with the ENDF/B-VII.0 library.

Estimation of greenhouse gas emissions from an underground wastewater treatment plant

  • Kyung, Daeseung;Jung, Da-Yoon;Lim, Seong-Rin
    • Membrane and Water Treatment
    • /
    • 제11권3호
    • /
    • pp.173-177
    • /
    • 2020
  • Wastewater treatment plants (WWTPs) have been recognized as one of the significant greenhouse gas (GHG) generators, due to the complex biochemical reaction and huge consumption of energy and materials. Recently, WWTPs have been built underground and they will be confronted with the challenges of mitigating GHG emissions and improving the quality of treated wastewater. Here, we focus on estimating GHG emissions to set up effective management plans for a WWTP built underground. First, we apply the process-based life cycle assessment (LCA) with an inventory database of the underground WWTP for a case study. Then, we identify significant factors affecting GHG emissions during service life using sensitivity analysis and suggest the proper tactics that could properly reduce GHG emissions from the WWTP.

수온에 따른 강도다리 Platichthys stellatus의 산소소비 리듬 (Diel Rhythm of Oxygen Consumption of the Starry Flounder Platichthys stellatus by Water Temperature)

  • 변순규;정민환;이종하;이배익;구학동;박상언;김이청;장영진
    • 한국수산과학회지
    • /
    • 제41권2호
    • /
    • pp.113-118
    • /
    • 2008
  • Diel rhythm of oxygen consumption (OC) of the starry flounder Platichthys stellatus was measured at different water temperatures in a closed recirculating seawater system with a respiratory chamber. The fish consumed 70.5, 79.7, and 90.6 mg $O_2/kg/hr$ at 15, 20, and $25^{\circ}C$, respectively, showing a linear increase in OC with water temperature. The OC of fish showed a clear diel rhythm, with lower values during the day and higher values at night, in accordance with the light (09:00-21:00) and dark (21:00-09:00) phases of the diel cycle (12L:12D) in water at 15 and $20^{\circ}C$. However, the OC of the fish showed an unclear diel rhythm with the light and dark phases of the diel cycle at $25^{\circ}C$. The respective OC at 15, 20 and $25^{\circ}C$ was 63.8, 72.4, and 88.4 mg $O_2/kg/hr$ during the light phases and 77.2, 87.1, and 92.8 mg $O_2/kg/hr$ during the dark phase. The starry flounder is thought to be a nocturnal fish with a higher OC at night, while it rests during the day. Its OC was the most stable in the light, when it did not feed. Consequently, the night-time OC is the active OC and the day-time OC is the resting OC in the starry flounder.

다목적 용수를 고려한 제주도 농업용 지하수 이용량 모델 개발 (Development of Agricultural Groundwater Usage Model Considering Multipurpose Water in Jeju Island)

  • 안중기;송성호;이동림
    • 한국환경과학회지
    • /
    • 제24권4호
    • /
    • pp.515-524
    • /
    • 2015
  • The estimation of groundwater usage in Jeju island is important to understand hydrologic cycle system and to plan management of water resource because large amounts of groundwater have been used for agricultural and domestic purpose. The model has been developed to estimate agricultural groundwater usage for garlic at uplands and citrus at orchards raising outdoors using the soil water balance model from FAO 56, respectively. The total amount of water supplied for the crop evapotranspiration and the multipurpose function such as sprout promotion can be simulated by the model. However, due to the discrepancy of water use in initial stage between calculated and observed, the model was calibrated and verified using actual groundwater usage monitoring data for 3.5 years (2011.6 to 2014.12) at three uplands for garlic and three orchards for citrus. Consequently, it would be concluded that the model simulated efficiently actual water usage in that root mean square (RMS) and normalized RMS of the validation stage were less than 8.99 mm and 2.43%, respectively, in two different conditions.

수변도시 물순환 관리 목표 산정 (Estimation of Water Cycle Management Goal in Waterfront City)

  • 김형산;이상진;김백중;백종석
    • 한국수자원학회:학술대회논문집
    • /
    • 한국수자원학회 2017년도 학술발표회
    • /
    • pp.413-413
    • /
    • 2017
  • 도시화로 인한 불투수면적의 증대는 지하수함량 감소, 도시열섬화 증가 및 도시 하천의 건천화를 발생시켰으며, 최근들어 이러한 문제를 해결하기 위해 지자체를 중심으로 도시지역의 물순환 회복을 위한 노력이 증가하고 있다. 또한 도시개발에 따른 물순환 왜곡 문제를 해결하고자 개발단계에서부터 도시개발에 필요한 물순환 목표를 설정하여 도시를 개발하는 수변도시 및 물순환 도시를 계획하고 있다. 이러한 수변도시의 물순환 설계시 고려해야할 사항으로 강우의 발생으로 인한 빗물은 소유역별 분산관리를 통해 발생지점에서 해결할 수 있도록 하는 방안과 개발되는 대상지역의 물순환을 개발 이전의 물순환 체계에서 크게 변화가 없도록 개발하는 방안이 제시되고 있다. 이를위해 저영향개발과 같은 비점오염 처리 시설과 더불어 LID 시설이 추가된다면 좀더 합리적인 물순환 과정에 도달할 수 있을 것이다. 본 연구에서는 K-water에서 수변도시로 개발하고 있는 송산그린시티사업의 동측지구를 대상으로 물순환 계획 및 설계에 대하여 검토하고 분석하였다. 기존 물순환 계획이 수립되어 있는 도시의 주요내용을 검토하였으며, 향후 분석결과를 실제적으로 적용할 때 발생할 수 있는 문제점에 대한 고려사항을 제시하였다.

  • PDF

RFID를 이용한 수자원시설관리기법 개발 (Development of method management for water resources facilities using RFID)

  • 황의호;고덕구;이근상;이을래
    • 한국수자원학회:학술대회논문집
    • /
    • 한국수자원학회 2009년도 학술발표회 초록집
    • /
    • pp.1723-1728
    • /
    • 2009
  • 수자원시설물의 유지관리와 조사, 계획, 설계, 제작, 설치, 운전, 보전을 거쳐 폐기에 이르는 시설물의 Life Cycle을 관리하기 위해 IT 기술을 이용하여 설비를 체계적으로 운영 관리하고 있다. 수자원시설의 점검관리에 있어 기존의 관리방법은 점검자가 관리항목을 대장에 기입하고 기입한 자료를 PC에 저장하여 관리함으로써, 업무의 복잡성 및 중복성이 발생됨으로써 업무효율이 저하되고 있는 실정이다. 이에 따라, 본 연구에서는 이러한 문제점을 효율적으로 해결하기 위하여 유비쿼터스 기술인 RFID를 현장에 적용하기 위하여 수자원시설에 대하여 표준코드를 정립하였으며, 수자원시설 이력관리 구축을 위하여 RFID 현장에 적용하고, RFID 리더기를 이용하여 시설물의 이력 관리 시스템과 연동하여 체계적인 시설관리 기반을 구축하였다. 이로써, 시스템을 통해 관리되는 시설물의 이력정보를 활용하여 설비 교체주기, 통계자료 조회, 예산 반영 계획수립 등의 업무에 즉시 적용이 가능하며 체계적이고 효율적인 업무수행이 가능할 것으로 판단된다.

  • PDF

Temporal variability of Evapotranspiration simulated by different models at the croplands

  • Choi, Min-Ha;Lee, Jin-Woo;Kim, Tae-Woong;Cho, Yong-Sik
    • 한국수자원학회:학술대회논문집
    • /
    • 한국수자원학회 2009년도 학술발표회 초록집
    • /
    • pp.535-539
    • /
    • 2009
  • Evapotranspiration (ET) is one of the main factor to understand the hydrologic cycle on land surfaces of entire globe. It accounts for about 65% of precipitation returning to the atmosphere. Accurate estimation of the ET is essential to many applications of water resources management, hydrology, meteorology, climatology, and agriculture. Over the past few decades, there have been extensive efforts to develop and validate a number of ET models. Priestley-Taylor (P-T) and Food and Agriculture Organization Penman-Monteith (P-M) models are generally recognized as simple, but great operational approaches to estimate ET over different land cover types. In this study, we compare/validate different models of increasing complexity, P-T, P-M, and Common Land Model (CLM) in croplands, IA.

  • PDF