• 제목/요약/키워드: water chemical characteristics

검색결과 2,151건 처리시간 0.04초

Fundamental Characteristics of Mortar According to the Changes in the Solid Content Rate of the Water-Reducing Agent (감수제의 고형분율 변화에 따른 모르타르의 기초적 특성)

  • Kim, Min-Sang;Lee, Jae-Jin;Hyun, Seong-Yong;Kim, Tae-Woo;Han, Min-Cheol;Han, Cheon-Goo
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 한국건축시공학회 2017년도 춘계 학술논문 발표대회
    • /
    • pp.156-157
    • /
    • 2017
  • It is possible in the case of the chemical admixtures for concrete currently being used in actual work sites to omit quality evaluation and replace it with the scores of the admixture manufactures; this can create a problem of decline in reliability in quality on the work site. Therefore this study sought to analyze the degree of influence changes in the solid content rate of lignin- and naphthalene-based water-reducing agents have on the fundamental characteristics of cement mortar. The results showed that in fresh mortar, the flow and amount of air decreases with decrease in the solid content ratio. In hardened mortar, the condensation strength had hardly any effect on the use of lignin-based water-reducing agent, but naphthalene-based water-reducing agent increased with the decrease in the solid content ratio.

  • PDF

A Study on the Ultrasonic Application for the Efficiency Elevation of Hydrogen Fuel Production (On the Decrease of Overpotential by LSV) (수소 연료생산의 효율 향상을 위한 초음파 응용에 관한 연구(LSV에 의한 과전압 저감 중심으로))

  • Ju, Eunsun;Park, Youngchul;Song, Mingeun;Son, Seungwoo
    • Transactions of the Korean hydrogen and new energy society
    • /
    • 제14권3호
    • /
    • pp.187-194
    • /
    • 2003
  • The production of hydrogen fuel depends basically on the water electrolysis. The study on the decrease of overpotential which activates the hydrogen production is the core to elevate the hydrogen production efficiency on principle. Characteristics on the overpotential decrease are observed through the micro reaction by ultrasonic in electrolytic cell. For the above, the electrochemical analyzer, i.e., BAS is applied, Experiments with ultrasonic forcing into 4 kinds of solution such as city water, city water plus nitrogen. distilled water, and distilled water plus nitrogen are carried out. And concentrations of KOH are 0%, 10%, 20% and 30%. The basic characteristics of the overpotential decrease are obtained through the analysis by LSV technique in sweep technique. In results, it is clarified that the ultrasonic influences the decrease of overpotential to obtain the efficiency elevation of hydrogen fuel production.

Investigating Water Quality Data of Finished Water in Domestic Water Treatment Plants (1994-1998) (국내 정수장 정수 수질자료의 특성분석 (1994년-1998년까지 5년간 자료를 중심으로))

  • Yoon, Jeyong;Cho, Soonhaeng;Kim, Haeshim
    • Journal of Korean Society on Water Environment
    • /
    • 제16권4호
    • /
    • pp.431-443
    • /
    • 2000
  • Water quality data from water treatment plants in Korea during 1994-1998 were investigated to find out the characteristics of their non compliance. The number of plants surveyed were approximately 600 and the number of samples were over 30,000. Ten parameters of water quality selected in this study and their non compliance % (inside parenthesis) were as follows: Heterotrophic plate count (0.14%), Total coliforms (0.08%), $NH_3$-N (0.29%), $NO_3$-N (0.14%), THMs (0.02%), Turbidity (0.11%), Residual chlorine (5.5%), $KMnO_4$ consumption (0.04%), Hardness (0.03%), pH (0.07%). These levels of non compliance were compared to those obtained from WIDB (Water Industry Database, 1996) of American Water Works Association. This study strongly supported that small water plants (<10,000 tons/day) were more vulnerable in meeting the regulation criteria of many water quality parameters such as Heterotrophic plate count. Total coliforms, $NO_3$-N, THMs, Turbidity, Residual chlorine, $KMnO_1$ consumption, Hardness and pH. The $NH_3$-N concentration was especially high in winter and its violation was frequently found in the specific areas such as the downstream of major rivers. The average THMs concentration was surprisingly low, indicating $13{\mu}g/L$ which is 43% of US. Accordingly, these characteristics must be reflected in establishing the effective management of water quality policy of drinking water in Korea.

  • PDF

Characteristics of Quality and Flow of Water Resources at Palaces in Seoul Metropolitan (서울 시내 궁궐 수원의 수질과 유동 특성)

  • Naranchimeg., B;Lee, Jae-Min;Woo, Nam-C.;Kim, Youn-Tae;Lee, Kang-Jin
    • Journal of Soil and Groundwater Environment
    • /
    • 제16권2호
    • /
    • pp.61-76
    • /
    • 2011
  • This study was objected to provide suggestions for best management practices to restore the cultural and historical values of the wells in Palaces as well as their water qualities. Water resources in the five Palaces in Seoul Metropolitan, including Gyeongbokgung, Changdeokgung, Changgyeonggung, Jongmyo Shrine, and Deoksugung, were surveyed for their physical flows and chemical compositions from April to July in 2010. Ground waters in most wells were found at depths within 5 m from the ground surface, showing typical water-table aquifer systems. Hydraulic gradients indicate water resources in Gyeongbokgung, Changdeokgung, and Changgyeonggung flowing toward south, and toward east in Deoksugung area. Especially, water-level fluctuation data at S-10 in Deoksugung implied the influence of groundwater discharge facility. In Jongmyo Shrine, water was not detected in wells, indicating the water level was lower than the well depth. Based on the water chemistry and stable isotope analyses, water resources and their qualities appeared to be formed by the water-rock interaction along the groundwater paths. S-10 (Deoksugung) and S-14 (Changgyeonggung) samples were contaminated with nitrate ($NO_3$) in levels of higher than Korean drinking water standard, 10 mg/L as $NO_3$-N, but once in four sampling campaigns. In the situation that water resources in Palaces still maintain natural characteristics, the materials that will be used for the restoration and improvement of the Palace water supplies should be carefully selected not to disturb the natural integrity. In addition, because the wells are located in the center of metropolitan area, a systematic monitoring should be applied to detect and to manage the potential impacts of underground construction and various pollution sources.

Tests on Superplasticizers for High Strength Concrete (고강도 콘크리트용 고성능감수제 성능평가)

  • 노재호;김기철;조일호;한정호;박연동
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 한국콘크리트학회 1994년도 가을 학술발표회 논문집
    • /
    • pp.151-156
    • /
    • 1994
  • This study is to investigate the quality of superplasticizers in domestic market. Therefore, the physico-chemical characteristics, the fluidity characteristics of fresh cement paste and mortar were tested. Also fresh and hardened properties of mortars and concretes using these superplasticizers were tested. From these results, differences of quality among superplasticizers are checked clearly in low water/cement ratio. And it is concluded that several superplasticizers have better dispersion ability than others in every tests. It has known that all samples are naphtalene sulfornate formaldehede types by the UV(ultra-violet) test.

  • PDF

Assessment of Hydraulic Behavior and Water Quality Variation Characteristics in Underground Reservoir (지하저수조의 수리적 거동과 수질변화 특성 평가)

  • Lee, H.D.;Bae, C.H.;Kim, J.H.;Hwang, J.W.;Hong, S.H.
    • Journal of Korean Society on Water Environment
    • /
    • 제21권1호
    • /
    • pp.52-58
    • /
    • 2005
  • The assessment on characteristics of hydraulic behavior and water quality variations of underground reservoirs of buildings were studied. Firstly, it was thought that underground reservoir capacities($m^3$) of buildings should be not determinated by the uniform and same methods but be estimated on the basis of the dwelling areas on dominated households and their residential characteristics, because these characteristics influence significantly on actual water usages and patterns of buildings. Secondly, it was likely that the average reduction rate of residual chlorine in underground reservoirs were affected from the their capacities, because the average reduction rate of residual chlorine in underground reservoirs under $1,000m^3$ was 43 percent, on the other hand, that rate of underground reservoirs over $1,000m^3$ was 60 percent. Thirdly, through the field investigation, the retention time of drinking water in underground reservoirs were in the range from 0.3 day to 3.9 day. In addition to, the average reduction rate of residual chlorine were depended largely on the retention time of drinking water. When the retention time was under 24 hours, the average reduction rate of residual chlorine was 45 percent, and in case of over 24 hours, was 49 percent. Fourth, water level in underground reservoirs was averagely varied in the range from 0.1 m to 2.65 m at the height of underground reservoirs. If considered actual height of underground reservoirs, 37.6 percent of the height of underground reservoirs was only used. Consequently, the frequency of the inflow and outflow of drinking water in underground reservoir were very increased, and had an effect on the reduction of residual chlorine. Lastly, the investigations on hydraulic structure characteristics of underground reservoirs inside showed the locations of inflow and outflow of drinking water almost were in the opposite direction. And some buildings had several baffles in the middle. Nevertheless, their installations had no beneficial for the improvement of water quality.

Electrochemical Characteristics of Highly Porous Carbon Prepared by Chemical Activation Method for EDLC (화학적 활성법으로 제조된 EDLC용 고다공성 탄소전극의 전기화학 특성)

  • Eo, Soo-Mi;Kim, Han-Joo;Oh, Seung-Mo;Park, Soo-Gil
    • Proceedings of the KIEE Conference
    • /
    • 대한전기학회 2005년도 제36회 하계학술대회 논문집 C
    • /
    • pp.2010-2012
    • /
    • 2005
  • Activated carbon was activated with chemical treatment to attain high surface area with porous structure. We have been considered activated carbon is the ideal material for high voltage electric double layer capacitor due to their high specific surface area, good conductivity and chemical stability. In this study we found that increase in electrochemical capacitance due to activated carbon. Also chemically activated carbon and water treatment have resulted larger capacitance and also exhibits better electrochemical behavior, and is about 15% more than in untreated state. The structural change in activated carbon through chemical treatment activation was investigated by using SEM and XRD. In this study, the dependence of the activation behavior with KOH in the micro structure of host materials will be discussed. Furthermore, the relation to the electric double layer capacitance, especially the specific capacitance per unit area, is also discussed.

  • PDF

Heat Treatment Effect on Anti-Tacking Properties of an Zn-stearate/TEA-stearate/Water Emulsion System

  • Qin, Pei;Lee, JinBae;Ha, KiRyong;Ahn, WonSool
    • Elastomers and Composites
    • /
    • 제54권3호
    • /
    • pp.241-246
    • /
    • 2019
  • Carbon master batch (CMB) rubber sheets, which are stored in stacks, are difficult to separate during reuse because of the adhesion between sheets caused by the stacked weight over time. To solve this problem, in the actual rubber product manufacturing process, various anti-tacking agents (solid powder or liquid surfactants) are applied to the sheet surface. In this study, the emulsion samples of zinc (Zn)-stearate/triethanolamine (TEA)-stearate mixtures were prepared using TEA-stearate as a surfactant, prepared using an industrially manufactured Zn-stearate powder, and their basic anti-tacking properties were studied. During the process of manufacturing emulsion, a heat treatment process and an auxiliary surfactant were introduced to improve the dispersion stability. Results showed that the heat-treated sample exhibited a significant improvement in terms of sedimentation, storage stability, and anti-tacking characteristics since the Zn-stearate particles were reduced to a smaller size by the heat-treatment than that of the original Zn-stearate powder.

Adsorption Performance of Basic Gas over Pellet-type Adsorbents Prepared from Water Treatment Sludge (정수장 슬러지로부터 제조한 입상흡착제의 염기성 가스 흡착 성능)

  • Bae, Junghyun;Park, Nayoung;Lee, Choul Ho;Park, Young-Kwon;Jeon, Jong-Ki
    • Korean Chemical Engineering Research
    • /
    • 제51권3호
    • /
    • pp.352-357
    • /
    • 2013
  • In this study, the pellet-type adsorbents were prepared by extrusion using water treatment sludge. Effects of binder and calcination on physical and chemical properties of pellet-type adsorbents were investigated. The porous structure and surface characteristics of the adsorbents were studied using nitrogen adsorption, compression strength, scanning electron microscope, X-ray diffraction, and infrared spectroscopy of adsorbed pyridine. With increasing of binder content to 5 wt%, the compressive strength of pellet-type adsorbent could be improved more than three times, but the surface area reduced by 30%, and thus the breakthrough time of trimethylamine was shortened. The breakthrough time of the trimethylamine, a basic gas, could be increased more than three times through calcination, which seems to be due to generation of acid sites composed of Lewis acid and Br$\ddot{o}$nsted acid sites on the adsorbent surface.

Adsorption Characteristics of Water Vapor on Zeolite (Zeolite의 수증기 흡착특성)

  • Lee, Song-Woo;Na, Young-Soo;An, Chang-Doeuk;Lee, Min-Gyu
    • Journal of Environmental Science International
    • /
    • 제20권5호
    • /
    • pp.667-672
    • /
    • 2011
  • The purpose of this work is to present the experiment results by a dynamic adsorption of water vapor on pelletized zeolites (ADZ300, ADZ400, and ADZ500) in fixed bed. The breakthrough curves of water vapor with several different concentrations and temperature in the range of 25~45 $^{\circ}C$ on zeolite bed were investigated. In the same conditions, the breakthrough time on ADZ400 and ADZ500 were little longer than ADZ300, and the equilibrium adsorption capacity on ADZ500 was highest. The higher the concentration of water vapor was, the faster the breakthrough time was, and the slope of breakthrough curves showed a tendency to increase. The faster the flow rate of water vapor was, the faster the breakthrough time was relatively, but variations between flow rate and breakthrough time did not have a proportional relationship. The breakthrough curve maintained constant gradient in spite of variation of flow rate in the same concentration. The temperature rise in zeolite bed by adsorption heat was occurred in the early stage of adsorption. After water molecule layers were formed on the surface of zeolite, the temperature was slowly cooled by water vapors continuously flowed in as constant temperature. The greater the concentration of water vapor and adsorption temperature were, the temperature difference in zeolite bed was increased.