• Title/Summary/Keyword: water additives

Search Result 613, Processing Time 0.04 seconds

A Study on the Recycling of Metals and Removal of Organics By Electrochemical Treatment of Mixed Waste Water of Surface Finishing Industry (표면처리 공정에서 발생하는 혼합 폐수의 전기화학적 처리에 의한 중금속의 재활용 및 유기물의 제거에 관한 연구)

  • 김영석;이중배
    • Journal of the Korean institute of surface engineering
    • /
    • v.36 no.2
    • /
    • pp.184-193
    • /
    • 2003
  • Cyclic sweep voltametry was performed to investigate the electrochemical behavior of heavy metal ions and the organic additives in surface finishing process. And electrolysis using parallel plate electrode electrolyzer was carried out to simulate the treatment of real waste water. Results showed that more than 99 percent of Cu was recovered and selective recovery of Cu in mixed waste water was possible, but the possibility of economical recovery of Ni and Cr were very low due to the evolution of hydrogen gas. Electrochemical oxidation of cyanide and organic additives on anode showed very excellent removal rate. The complete removal of several hundred ppm of cynide was possible within several tens minutes and organics within 2 or 3 hours. Even in case of concentrate waste water, the complete removal of COD by using NaCl and air stirring seemed to be possible.

Investigation of Inhibition Effect on Hydrate Formation by Chemical Additives (화학첨가제를 이용한 하이드레이트 형성 억제 효과 분석)

  • Lee, Jeong-Hwan;Baek, Young-Soon
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2005.06a
    • /
    • pp.618-621
    • /
    • 2005
  • In this study, the phenomena of hydrate formation and inhibition were investigated according to varying the concentrations using methanol and ethylene glycol as chemical additives. The results reveal that the used additives display better inhibition effects compared to pure water by decreasing the formation temperature and the inhibition performance of methanol is superior to that of ethylene glycol. As a conclusion, the plugging phenomena of flowline in natural gas product ion. subsea and frozen field pipelines can be predicted by examining the hydrate formation and inhibition conditions. Specifically, the results of this study can be applied to the selection of the prevention criteria and method of hydrate formation.

  • PDF

A Study on the Extinguishing Performance of Water Mist with Additives (첨가제가 혼합된 미세물분무의 소화성능에 관한 연구)

  • 이경덕;신창섭
    • Fire Science and Engineering
    • /
    • v.16 no.1
    • /
    • pp.1-7
    • /
    • 2002
  • Halogen-based fire suppressing agents have environmental problems because they cause the stratospheric ozone depletion and globe warming. Hence, fire suppression system using fine water mist became the center of interest as a substitution of halon. As a study about this, it is in progress to make the optimum droplet size by using water mist nozzles and to improve the extinguishing performance of water mist by using additives. Before this study, the extinguishing time of ethanol and n-heptane pool fire was measured with changing of water mist droplet size, flow density, discharge pressure, and fire size. In this study, on adding the additives to improve physical and chemical extinguishing performance of water mist, the extinguishing performance would evaluate and the optimum condition would find out. As a result, in case of ethanol pan 1 pool fire, the extinguishing time of the water mist by adding of 2.5 wt% NaCl and 0.3% AFFF got shorter 27% and 60% than the pure water mist. Adding of AFFF was to decrease the flame temperature by forming thin film on the fuel surface and to decrease the evaporation of n-heptane fuel. In case of NaCl, alkali salt crystals showed on the flame surface.

Effect of the Environmental Issue Instruction on the University Student's Environmental Literacy (환경쟁점수업이 대학생의 환경소양 신장에 미치는 영향)

  • Park, Ki-Hak
    • Journal of environmental and Sanitary engineering
    • /
    • v.23 no.4
    • /
    • pp.1-11
    • /
    • 2008
  • The goal of today's environmental education is to enhance the understanding of the serious of environmental problems and the interactions among environment. With this perspectives people need to be aware that environmental education is no longer a liberal arts in university education, but play a vital role within the socio-cultural context. This study was performed to assess the changes in the university student's attitudes and consciousness in real life after the education of a point at issues of environmental problems. For this study 11 questionnaires which were composed of large scale environmental problems(water and air pollution), and small scale environmental problems(food additives, GMO, endocrine disrupter) were performed with self-administered by university students(n=781) who made a application for liberal arts related to environmental subjects. According to the analysis the most student's consciousness of a point at issue of environmental problems(water pollution, air pollution, additives, GMO, endocrine disrupter), and practical attitudes(i.e., practical attendant at congregation and internet voting) were change statistically significant(p<0.01) after the education of a point at issue of environmental problems rather than before. Specially, the score for the item of the large scale problem of environmental issues(water pollution, air pollution) were decreased significantly(p<0.01), but the score for the small scale problems, such as food additives, GMO, endocrine disrupter were increased significantly(p<0.01) after the education of a point at issue of environmental problems(p<0.01). And among the students that participated, 97.7% responded that such a point at issues of environmental problem is needed at the university. With this educational improvements supports the states that the education of a point at issue of environmental problems were more essential, practical and needed to students at university rather than that of an existing instruction. Thus, further studies are required to develop the education of environmental issues at universities like STSE programme.

The Influences of Additives and Curing Temperature on the Expansion Pressure of Calcium Oxide Hydration (생석회의 팽창압 발현에 미치는 첨가제 및 양생온도의 영향)

  • Kim, Won-Ki;Soh, Jeong-Soeb;Kim, Hoon-Sang;Kim, Hong-Joo;Lee, Won-Jun;Shin, Jin-Ho
    • Journal of the Korean Ceramic Society
    • /
    • v.44 no.9
    • /
    • pp.529-535
    • /
    • 2007
  • Calcium oxide has been used as a demolition agent in fracturing rocks and old concrete structures, etc. With the agent, demolition work can be done in safety without a noise, vibration and any other pollution, since high expansive pressure is obtained gradually by only mixing the agents with water and pouring the slurry into boreholes. But application of the non-explosive demolition agent is a time-consuming job, especially in winter. Essentially, this problem is related to the reaction rate of calcium oxide with water. This study examines the influence of additives such as cement and anhydrite on expansion pressure of calcium oxide at different curing temperatures. The expansion pressure of calcium oxide began to increase steadily with the rise of the curing temperature. When mixing calcium oxide alone with water, blown-out shot occurred. But as additives were added to calcium oxide, the reaction of calcium oxide delayed and the expansion pressure showed gradual increment. Especially, anhydrite showed a superior delaying effect than cement on the reaction of calcium oxide.

AA-GWR Water Retention Meter를 이용한 부동화 농도 측정법

  • Choe, Chang-Hak;Joy, Margaret K.;Lee, Do-Ik
    • Proceedings of the Korea Technical Association of the Pulp and Paper Industry Conference
    • /
    • 2003.04a
    • /
    • pp.80-92
    • /
    • 2003
  • The water retention of coating colors can be accurately measured by devices such as an AA-GWR water retention meter whose principle of measurement is based on pressure filtration of coatings under an externally applied air pressure over a certain period of time. It was hypothesized that such devices could be also used to determine the immobilization solids(IMS) of coating colors by determining a sudden drop in the rate of dewatering, that is, a sudden change in the drainage curves. To test this hypothesis, the immobilization solids of coating colors containing various thickeners and water retention additives at different levels were first accurately measured by a modified immobilization tester based on the well-known gloss drop method, and then their values were compared with those obtained by an AA-GWR water retention tester. They agreed very well and showed that the mean of the solids differences is 0.36% in the IMS points between both methods. This good agreement was not surprising because both test methods are based on the same end-point, that is, the immobilization solids point at which menisci begin to form at the coating surface. Theoretical considerations supporting this new method for measuring the immobilization solids of coating colors are presented and some recommendations for the test method are discussed. Also, the effect of various thickeners and water retention additives on the properties and printability of coated papers is discussed.

  • PDF

Studies on the Determination Method of Hydrogen Peroxide in Foods (식품 중 과산화수소의 분석법에 관한 연구)

  • Lee, Tal-Soo;Lee, Young-Ja;Park, Jae-Seok;Kwon, Yong-Kwan;Hwang, Jung-Yeon;Lee, Ju-Yeun;Lee, Chul-Won
    • Korean Journal of Food Science and Technology
    • /
    • v.34 no.6
    • /
    • pp.998-1001
    • /
    • 2002
  • Micro-LC method for the quantitative determination of hydrogen peroxide in foods has been established. This method was carried out on cation-exchange resin gel column using distilled water as mobile phase with 50 mM sodium sulfate as electrolyte. The detection was performed with an electrochemical detector (ECD) at 0.6 voltage. Under this analytical condition, the recovery rates of hydrogen peroxide in tomato and lemon were 98.3 and 97.4%, respectively. Among 28 food types, hydrogen peroxide concentrations were 0.6, 0.5, 1.9, 0.9, 0.5, 0.6, 0.9, 0.8, and 0.4 ppm in banana, peach, orange, strawberry, pepper, onion, cucumber, burdock, and egg plant, respectively, Whereas none was detected in remaing 19 samples.

Properties of reduced and quenched converter slag

  • Ko, In-Yong;Ionescu Denisa;T. R. Meadowcroft
    • Proceedings of the IEEK Conference
    • /
    • 2001.10a
    • /
    • pp.542-546
    • /
    • 2001
  • Converter slag has some compositional similarities to portland cement. But it has no hydration properties due to it's quite high concentrations of FeO(20-35%), MnO(4-6.5%). So it is needed to reduce the concentrations of iron and manganese of converter slag to use as cement additives by enhancing it's hydration properties. In this study, converter slag was modified it's composition by mixing of silica, alumina and quenched BF slag and reduced in induction furnace and quenched in running water. The hydraulic properties and structures of modified and quenched converter slag are significantly changed depend on the amount and kinds of additives. The addition of alumina up to 10% and BFQ slag up to 20% by weight on converter slag was effective to enhance the hydraulic properties of modified and quenched slag. The addition of reduced and quenched converter slag up to 20% by weight in replacement of portland cement in mixing of concrete mortar were shown higher compressive strength than 100% cement concrete mortar.

  • PDF

Development of Chemical Cleaning Agents for Cleaning Indoor Water Supply Pipes (옥내급수관 세척용 화학세정제 개발 연구)

  • Lee, Jae-Hoon;Jung, Jae-Yong;Park, Yong-Bae;Bae, Jae-Heum;Woo, Dal-Sik;Sin, Hyun-Duk
    • Clean Technology
    • /
    • v.16 no.3
    • /
    • pp.162-171
    • /
    • 2010
  • The objective of this study is to develop cleaning agents for the indoor water supply pipe which is environmentally friendly and suitable for removing scale by using various organic acids, inorganic acids, and some additives. Among various organic acids, oxalic acid, citric acid, and malic acid showed good cleaning efficiency of iron oxides which were main components of the indoor water supply pipe scale. Several cleaning agents were formulated by adding chemical additives into these organic acids and evaluated for removal of iron oxides. In this study, it was found that nonionic surfactants were excellent for the removal of iron oxide scale among various additives. Two types of cleaning agents($F_1$, $F_2$) with comparatively high solvent power for iron oxides were formulated in this study. The cleaning agents $F_1$ made by organic acids and some additives were formulated to be safe and environmentally friendly, but seemed to have disadvantage due to their comparatively low cleaning efficiency of iron oxide than $F_2$. But, the cleaning agents $F_2$ prepared by adding inorganic acid a little to $F_1$ showed comparatively good cleaning efficiency of iron oxide and could be recommended for removing hard scale of iron oxides in the indoor water supply pipe. Thus, it is considered that the formulated cleaning agents should be selected based on the extent of scale in the indoor water supply pipe.