DEVELOPMENT OF NIGHT COOLING SYSTEM FOR GREENHOUSE USING COOL AIR AND WATER FROM AN ABANDONED COAL MINE

  • Whoa S. Kang;Wie S. Kang;Lee, Gwi H.
    • Proceedings of the Korean Society for Agricultural Machinery Conference
    • /
    • 1996.06c
    • /
    • pp.1136-1145
    • /
    • 1996
  • This study was to develop the most effective cooling system which is needed to cool greenhouse during summer night to get early blooming of strawberries. Various cooling systems were designed and constructed to utilize the cool air and water from tan abandoned coal mine. Cooling systems built for this study were an evaporative cooling system with pad, cooling system using a small or large radiator , and duct cooling system using cool are drawn from coal mine. These systems were individual tested to investigate their effects on cooling greenhouse during summer night. Also, a combined cooling system was tested with operating an evaporative cooling system, small radiator, and duct cooling system simultaneously. The results in this study showed that individual cooling systems such as evaporative cooling system, small radiator, and cooling duct had about the same effect on cooling greenhouse. The combined system had little better cooling effect than that of individual cooling syst m except the large radiator . The most effective system for cooling of greenhouse was obtained with using a large a large radiator as the heat exchanger. With operating a large radiator, temperature inside the greenhouse was dropped to about 15-16$^{\circ}C$ while outside temperature was 23-24$^{\circ}C$ during summer night.

  • PDF

Effect on Household Absorption Chiller by the Supply of the Cooling Water (냉각수 보급이 가정용 흡수식 냉난방기의 성능에 미치는 영향)

  • 이호생;김동휘;최병권;김재돌;윤정인
    • Proceedings of the Korean Society of Marine Engineers Conference
    • /
    • 2002.05a
    • /
    • pp.267-272
    • /
    • 2002
  • The electric heat pump requiring HCFCs as a refrigerant has been for most residential air-conditioners in Korea. They cause a surge up electric power demand during summer. Moreover, the use of HCFCs and HFCs causes a serious problem to the global environment such as global warming and ozone layer destruction. An absorption chiller and heater could solve such problems. It was built and tested for analyzing the performance of the absorption chiller/heater. Experiment was done with a 1.5RT household absorption chiller and heater. It was experimented that the cooling capacity, gas capacity, COP were researched by the temperature of cooling water. The change of the cooling water temperature have effect the temperature(or pressure) of the parts on absorption chiller The result of the change of the cooling water temperature have the effects of the absorption chillers. This data will help to operate the household absorption chiller and heater.

  • PDF

Temperature analysis of extra vessel electromagnetic pump cooling for a Micro nuclear reactor with an electric power of 20 MW

  • Tae Uk Kang;Hee Reyoung Kim
    • Nuclear Engineering and Technology
    • /
    • v.56 no.1
    • /
    • pp.275-282
    • /
    • 2024
  • Lead bismuth eutectic (LBE) is used as coolant for MicroURANUS, a small marine nuclear power plant, and this coolant is transported in the plant by an electromagnetic pump. Given the considerable heat generated by the electromagnetic pump, the cooling of the pump is essential. This study compared air cooling and water-cooling methods and found that the maximum temperatures during air and water cooling were 640 K and 372 K, respectively. These findings were utilized to design an electromagnetic pump with water-cooling. The maximum temperature of the pump was lower than the boiling point of water; thus, the pump did not require a separate pressurization. Consequently, the resistance problem of the coil and the deformation problem of the material caused by generated heat can be solved through water-cooling.

Evaluation for the Cooling Capability of Secondary Cooling Tower in HANARO (하나로 2차 냉각탑의 냉각능력 평가)

  • Park, Yong-Chul;Wu, Jong-Sup;Cho, Yeong-Gurb;Ryu, Jeong-Soo
    • 유체기계공업학회:학술대회논문집
    • /
    • 2000.12a
    • /
    • pp.345-350
    • /
    • 2000
  • The heat produced by the fission in the fuel of HANARO, 30 MW research reactor, is transferred from the primary cooling water to the secondary cooling water through heat exchangers, and the heat absorbed by the secondary cooling water is released into the atmosphere by the 33 MW cooling tower which is a mechanical induced draft and counter flow type. If the outlet temperature of cooling tower exceeds 33 of due to the loss of the cooling tower performance under reactor operation above $50\%$ of the full power, the reactor power should be reduced to half of the full power for safe operation. Therefore, the cooling capability of cooling tower should be maintained for the reactor to be normally operated. To predict the capability of cooling tower for full power reactor operation of 30 MW, the performance test of cooling tower was done at the reactor present power of 24 MW and the capability was respectively evaluated by characteristics and performance curves methods in accordance with the Code of Cooling Tower Institute of U.S.A. to confirm the reliability of evaluation. As a result, it was confirmed, through the results of each evaluation, that the cooling capability of cooling tower meets the design required heat load. Also, the equations of the performance and the characteristics curves of the cooling tower, based on the collected data during this performance test, was obtained for developing the calculation program to predict the cooling capability during reactor operation.

  • PDF

Effect of Refrigerant Pipe Length on Sea Water Cooling System Performance (해수냉각시스템 성능에 미치는 냉매배관길이의 영향)

  • Yun, Jeong-In;Jo, Yeong-Je
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.34 no.3
    • /
    • pp.346-351
    • /
    • 1998
  • The purpose of this study is analyzing the performance of sea water cooling system under various refrigerant pipe length. In sea water cooling system, the increase of refrigerant pipe length cause increases of pressure drops. These pressure drops cause fresh gas in liquid pipe and increase specific volume in gas pipe outlet, so sea water cooling system capacity is decreased by decrease of refrigerant mass flow rate. Sea water cooling system capacity in refrigerant pipe length 70m is decreased more than 30% when compared with pipe length 10m and the decrease of the coefficient of performance is nearly 20%.

  • PDF

CHANGES IN STAGNATION REGION AND RESIDENCE TIME OF COOLING WATER FOR VARIOUS FLOW CHANNEL GEOMETRY OF WATER COOLING GRATE (수냉식 화격자 유로 형상에 따른 냉각수의 정체 영역 및 체류 시간 변화)

  • Song, D.K.;Kim, S.B.;Park, D.W.
    • Journal of computational fluids engineering
    • /
    • v.21 no.2
    • /
    • pp.106-111
    • /
    • 2016
  • Waste-to-energy facilities including incinerators are known as an efficient method to reduce wastes. In waste-to-energy facilities, more efficient cooling system is still needed for grates as the energy density of waste increased. For better cooling performance with the water-cooled grates, optimal design of cooling water pathways is highly beneficial. We performed numerical investigation on fluid flow and residence time of cooling water with change of the geometry of the cooling water pathway. With addition of round shaped guide vanes in the water pathway, the maximum residence time of flow is reduced(from 4.3 sec. to 2.4 sec.), but there is no significant difference in pressure drop between inlet and outlet, and average residence time at the outlet. Furthermore the flow stagnation region moves to the outlet, as the position of the round shaped guide vanes is located to the neck point of pathways.

Effects of Water Amount in Refrigerant on Cooling Performance of Vehicle Air Conditioner (냉매 내 수분의 혼입량이 차량 에어컨의 냉각성능에 미치는 영향)

  • Moon, Seong-Won;Min, Young-Bong;Chung, Tae-Sang
    • Journal of Biosystems Engineering
    • /
    • v.36 no.5
    • /
    • pp.319-325
    • /
    • 2011
  • This study was conducted to figure out the diagnosis basis of cooling performance depending on water amount in the refrigerant of air conditioner, which can be estimated by the temperatures and pressures along the refrigerant circulation line. A car air conditioner of SONATA III (Hyundai motor Co., Korea) was tested at maximum cooling condition at the engine speed of 1500 rpm in the room controlled at 33~$35^{\circ}C$ air temperature and 55~57% relative humidity conditionally. Measured variables were temperature differences between inlet and outlet pipe surfaces of the compressor, condenser, receive drier and evaporator; and high pressure and low pressure in the refrigerant circulation line; and temperature difference between inlet and outlet air of the cooling vent of evaporator. In this study, changes of the water amount in the refrigerant were correlated to the temperatures and pressure changes and also water amount caused poor cooling performance. As water amount increased in the refrigerant in the air conditioner, the performance of the cooling or the heat transfer became worse. Temporal variations of the surface temperature of the evaporator outlet pipe and the low-side pressure showed various patterns that could estimate the water amount. When the water amount caused bad cooling performance, the patterns of the temperature of the evaporator outlet pipe indicated irregular fluctuation greater than $5^{\circ}C$. When the diagnosis system is using just external sensors of the low-side pressure and the temperatures of inlet and outlet air of cooling vent of the evaporator, the precise pattern of bad cooling performance caused by excess water amount in the cooling line was irregular pressure fluctuation, 25 kPa under 120 kPa, and temperature, $12^{\circ}C$ and less.

Thermal Performance Characteristics of Closed-Wet Cooling Tower (밀폐형 냉각탑의 열성능 특성에 관한 실험적 연구)

  • Sarker, M.M.A.;Kim, E.P.;Moon, C.G.;Yoon, J.I.
    • Journal of Power System Engineering
    • /
    • v.9 no.2
    • /
    • pp.88-92
    • /
    • 2005
  • The experiment of thermal performance about closed-wet cooling tower was conducted in this study. A closed cooling tower is a device similar to a general cooling tower, but with cooling tower replaced by a heat exchanger. The test section for this experiment has the process that the cooling water flows from the top of the heat exchanger to the bottom side in the inner part of the tube, and spray water flows in the gravitational direction in the outer side. Air comes in direct contact with the spray water at the outer side of the tube while passing from the lower the upper part having a counterflow to the spray water. The heat transfer pipe used in this experiment is a bare-type tube having an outer diameter of 15.88mm. The heat exchanger is consisted of seven rows and fifteen columns. In this experiment, thermal performance of the cooling tower is derived from overall heat transfer coefficients between the process fluid and sprayed water and volumetric overall mass transfer coefficient between sprayed water and air.

  • PDF

Water Quality Control System Development for Cooling Towers (냉각탑 수질관리를 위한 자동화 시스템 개발)

  • Lee, Ki-Keon;Song, Moo-Jun;Lee, Young-Jae;Sung, Sang-Kyung;Kang, Tae-Sam
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.14 no.1
    • /
    • pp.36-41
    • /
    • 2008
  • Cooling tower is an important equipment of the cooling systems for large buildings like factory and department store. Water used for cooling in cooling tower is reused continuously. If the water is polluted, corrosion and scale can happen at equipments and pipes. In order to prevent this problem, it is necessary to control the water quality using chemicals. To control the water quality, an automatic control system is designed, fabricated, and experimented. The control system is based on an imbedded microcontroller. Relays are used for power driving, an LCD and LED for display, and RS485 for remote data acquisition. Monitoring program is also developed for easy man-machine interface and extraction of data stored in the imbedded processor and EEPROM. The control system calculates amounts of chemicals necessary using sensor data and injects the chemicals into the cooling tower on proper time. The developed water quality control system is expected to reduce cost of maintenance and extend the lifetime of the cooling systems with low cost.

The performance evaluation of outdoor unit cooling system in a residential apartment complex (주상복합의 실외기 형태에 따른 냉방시스템 성능 평가)

  • Kyung, Seo-Kyung;Kim, Yun-Jin;Lim, Jung-Hee;Kim, Byung-Seon
    • 한국태양에너지학회:학술대회논문집
    • /
    • 2008.11a
    • /
    • pp.263-268
    • /
    • 2008
  • In a residential complex case, the efficiency of land use are maximized, but a variation of external condition such as load in-equality, the increase in wind velocity and solar radiation by a height causes increasing energy in a building. Besides, because of increasing window size for a lighting and a view, it comes heating load in winter and cooling load in summer. A choice of cooling-system is important for this reason. Recently an internal high-rise residential complex installs an air-cooling system and operates individual heating. However, this study applies water-cooling used one public cooling-tower instead of an air-cooling system, also with an efficiency test of an air and a water-cooling system, consider an internal applicability.

  • PDF