• 제목/요약/키워드: wastewater reuse

검색결과 281건 처리시간 0.026초

Application of Membrane and Adsorption Hybrid Processes for Industrial Wastewater Reuse

  • Jeun, Joung-Ick;Kwon, Tea-Ouk;Moon, Il-Shik;Jung, Heung-Joe;Lee, Jae-Wook
    • 한국막학회:학술대회논문집
    • /
    • 한국막학회 2004년도 Proceedings of the second conference of aseanian membrane society
    • /
    • pp.113-116
    • /
    • 2004
  • Water demand and wastewater production is steeply increasing and the gap between water supply and demand is getting wider. Wastewater is considered a major water resource in many countries. Therefore, wastewater reuse has been considered as a promising solution to the shortage of water resources (Madwar and Tarazi, 2002; Fane, 1996; Bodalo-Santoyo et al., 2003; Mohsen and Jaber, 2002; Nicolaisen, 2002; Lawrence2002).(omitted)

  • PDF

하수의 농업적 재이용에 따른 논 담수 내 미생물 위해성 평가 (Microbial Risk Assessment in Reclaimed Wastewater Irrigation on a Paddy Field)

  • 이한필;윤춘경;정광욱;손장원
    • 한국물환경학회지
    • /
    • 제25권1호
    • /
    • pp.69-75
    • /
    • 2009
  • Water stress has become a major concern in agriculture. Korea suffers from limited agricultural water supply, and wastewater reuse has been recommended as an alternative solution. A study was performed to examine the effects of microorganism concentration in the ponded-water of a paddy rice field with reclaimed-water irrigation for evaluating the microbial risk to farmers and neighborhood children. Most epidemiological studies were performed based on an upland field, and they may not directly applicable to paddy fields. Beta-Poisson model was used to estimate the microbial risk of pathogen ingestion. Their risk value increased significantly high level after irrigation and precipitation. It implies that agricultural activities such as plowing, and fertilizing, and precipitation need be practiced a few days after irrigation considering health risks. The results about field application of the microbial risk assessment using E. coli showed difference according to monitoring time and treatment plot. Result of the microbial risk assessment showed that risk values of ground-water and reclaimed secondary wastewater irrigation were lower than directly use of wastewater treatment plants' effluent. This paper should be viewed as a first step in the application of quantitative microbial risk assessment of E. coli to wastewater reuse in a paddy rice farming.

하수처리수 재이용에 따른 하천과 해역의 환경복원 및 수질관리 모델링 (Environmental Restoration and Water Quality Management Modeling of Coastal Area by Reuse of Treated Wastewater)

  • 이대인;윤양호;박일흠;이규형;조현서
    • 한국환경과학회지
    • /
    • 제16권4호
    • /
    • pp.505-521
    • /
    • 2007
  • This study estimated response of water duality and pollutant behavior according to the discharge and reuse of treated wastewater by three-dimensional eco-hydrodynamic model, and suggest plan that water quality management and environmental restoration in the coastal area including urban stream of Yeosu, Korea. Dispersions of low-saline water and COD by treated wastewater loads (design facility capacity, about $110,000m^3/d$) were very limited in near of effluent site. Nutrients, however, increase compared to the other water quality factors, especially total nitrogen was very sensitive to input loads. When reuse some of treated wastewater to Yeondeung stream, nitrogen was big influence on estuarine water quality. Although current characteristics of treated wastewater such as discharge and water quality were negligible to the change of marine environment, effluent concentration of COD, TN and TP, especially 40% of TN, are reduced within the allowable pollutant loads for satisfy environmental capacity and recommended water duality criteria. Also, controls of input point/non-point sources to Yeondeung stream and base concentration of pollutants in coastal sea itself are very necessary.

Municipal wastewater reclamation for non-potable use using hollow- fiber membranes

  • Waghmare, Sujata;Masid, Smita;Rao, A. Prakash;Roy, Paramita;Reddy, A.V.R.;Nandy, T.;Rao, N.N.
    • Membrane and Water Treatment
    • /
    • 제1권3호
    • /
    • pp.207-214
    • /
    • 2010
  • Approximately 80% of water used in urban areas reappears as municipal wastewater (MWW). Reclamation of MWW is an attractive proposition under the present scenario of water stressed cities in India. In this paper, we attempted to reclaim MWW using lab-scale hollow- fiber (HF) membrane modules for possible reuse in non-potable applications. Experiments were conducted to evaluate the efficiency of virgin HF ($M_1$) and modified HF ($M_2$) modules. The $M_2$ module consists of HF modified with a skin layer formed through interfacial polymerization of m-phenylenediamine with trimesoyl chloride (MPD-TMC). The molecular weight cut-off (MWCO) of $M_1$ was 44000 g/mol and that of $M_2$ 10000 -14000 g/mol on the basis of rejection of polyethylene glycol. The combination of $M_1$ and $M_2$ modules was able to reduce concentrations of most of the pollutants in sewage and improved the treated water quality to the acceptable limits for non potable reuse applications. It is found that about 98-99% of the initial flux is recovered by the backwashing process, which was approximately two times in a month when operated continuously.

처리수 재이용을 위한 최종침전지 유출수의 급속여과공정 처리특성 (Treatment Characteristics of Rapid filtration Process treating Secondary Clarifier Effluent for Wastewater Reuse)

  • 한동우
    • 한국수자원학회논문집
    • /
    • 제35권2호
    • /
    • pp.213-220
    • /
    • 2002
  • 하수 처리수의 재이용을 위하여 표준활성슬러지법에 의한 생물학적 처리 후 최종침전지 유출수를 급속여과공정으로 처리하기 위한 Pilot Plant 실험연구가 수행되었다. 또한, 활성슬러지와 연계된 급속여과공정과 포기조 후단에 응집제를 주입하는 활성슬러지 이후 급속여과 처리하는 공정과의 비교 실험도 행해졌다. 최종침전지 유출수를 급속여과공정으로 처리한 경우 여과속도는 100m/day, 여과지속시간은 40시간 이하로 운전하는 것이 타당한 것으로 나타났으며, 여과지의 역세척 주기는 여과속도 100m/day일 때 40시간에 1회 정도가 되었다. 여과지 역세척 시 역세척 방법은 공세 1분, 공세+수세 30초, 수세 1분, 공세·수세 2분, 수세 3분, 안정 30초, 배수 10분의 순으로 행하는 것이 효과적이었으며, 수세속도는 10LPM으로 전체 여과수량의 2%정도였다. 표준활성슬러지 시스템에 의한 2차 처리수를 잡용수로 재이용 하기 위해서는 폭기조 후단에 응집제를 첨가하여 여과 공정을 후속공정으로 하는 시스템으로 유용하게 사용할 수 있을 것으로 판단된다.

하.폐수 처리용 MBR 분리막 기술 및 산업동향과 발전방향 (Trends in the Technology and Market of Membrane Bioreactors (MBR) for Wastewater Treatment and Reuse and Development Directions)

  • 조일형;김지태
    • 멤브레인
    • /
    • 제23권1호
    • /
    • pp.24-44
    • /
    • 2013
  • MBR 기술은 지난 20여 년 동안 처리성능과 효율성 그리고 비용절감 측면에서 빠른 속도로 발전하고 있다. 또한 안정적인 하수처리와 하수재이용관점에서 핵심기술로 널리 인식되고 있다. 본고에서는 MBR 기술의 개발과 상업적 응용에 관한 발전과정을 재조명하고 세계 시장의 전망을 제시하고자 한다. 주요 적용기술에 대해 다음 5가지 측면에서 검토하여 제시하였는데 1) MBR 기술의 진화, 2) MRBs의 상업용 기술, 3) 대용량 MBR 플랜트 설치 사례, 4) MBR 시장의 성장, 5) 기술의 발전방향 순으로 제시하였다. 마지막으로 MBRs에 대한 경제적, 환경적, 그리고 기술적 측면에서 향후 발전방향을 1) 초기투자비, 2) 처리 수질, 3) 분리막 소재/모듈, 4) MBR 장비와 공정, 5) 운영비용, 향후 6) 혐기성 MBRs 공정과 같은 차세대 기술 분야로 나누어 제시하였다.

우리 나라의 하수도현황과 전망 (State of Swerage Systems and Prospects in Korea)

  • 김갑수
    • 환경위생공학
    • /
    • 제8권2호
    • /
    • pp.65-84
    • /
    • 1993
  • This study reviewed the current status and problems of sewerage system in Korea and then proposed possible methods to correct the problems. Also, evaluation of future development in sewerage system is included. It can be summarized as follows : 1. Investment in sewerage system is relatively low . 0.23% of GNP, Considering that the investment portion is 0.35% in OECD and 0.63% in Japan, it should be increased further. 2. The reasons wily the investment in sewerage system is low can be ' (1) Low priority is given to the investment in sewerage system. Local government builds and operates its own wastewater treatment plant. Local government as well as residents prefer to invest their money in roadwork, housing and parks to in wastewater treatment facilities because of greater investment effects. (2) Besides capital investment, more maintenance cost is needed for sewerage system. Proper operation of wastewater treatment facilities requires a well-trained operator. Because of public conception that operation of wastewater treatment facility is a dirty job, it is difficult to find a well-trained operator. (3) It is difficult to estimate the effect of sewerage system (4) Cost required to build and maintain wastewater treatment facility should be paid by people, who benefit from the facility. People to benefit are sometimes different from people to pay. 3. Advanced treatment is necessary to protect the bay aura and raw water source as well as to prevent eutrophication of lakes and ponds. 4. Wastewater treatment facility were mainly build in big cities during the decade of 1980. Followings should be solved first to expand the facilities. (1) Rapid repair and construction of sewer. (2) Technical development of wastewater treatment . Prevention of efficient and economical wastewater . Development of efficient and economical wastewater treatment techniques . Development of high-efficiency treatment using bioreactor . Reuse of wastewater treatment plant effluent (3) Sludge treatment and disposal . Composting of sludge cakes . Development of techniques to reduce the volume of sludge cake : incineration and reuse of sludge ash and slag. (4) Utilization of wastewater treatment facilities . Construction of community parks or sports families(ie, on the tops of the covered aeration tanks and sedimention tanks) Construction of wastewater treatment facilities under ground and of parking facilities and community parks above ground. (5) Education of wastewater treatment personal.

  • PDF

Reduction of waterborne microorganisms in treated domestic wastewater for reuse in agriculture: Comparison between floating media filter and sand filter

  • Semsayun, Chalanda;Chiemchaisri, Wilai;Chiemchaisri, Chart;Patchanee, Nopparat
    • Environmental Engineering Research
    • /
    • 제20권4호
    • /
    • pp.403-409
    • /
    • 2015
  • This study aims to investigate the use of a floating media filter (FMF) to eliminate waterborne microorganism in treated domestic wastewater for reuse in agriculture. A conventional sand filter (SF) was used concurrently to compare treated water quality. The total/fecal coliforms and somatic coliphage were employed as fecal indicators. The result showed that the FMF was fed with 3 times higher infiltration rate ($15m^3/m^2.h$) than that in the SF ($5m^3/m^2.h$), in which both filters gave similar coliform removal at 6 hours operation. The somatic coliphage elimination tended to increase with operational time for the FMF while that of the SF showed decreasing trend. When a 24 hour continuous operation was applied for the FMF, it showed better removal of somatic coliphage (78%), fecal coliforms (60%) and total coliforms (56%) than that of 6 hour operation. In conclusion, the FMF gave better performance than the SF did by producing a good quality of treated water for agriculture in terms of waterborne microorganisms including turbidity and suspended solids.

Evaluation of effects of textile wastewater on the quality of cotton fabric dye

  • Kaykioglu, Gul;Ata, Reyhan;Tore, Gunay Yildiz;Agirgan, Ahmet Ozgur
    • Membrane and Water Treatment
    • /
    • 제8권1호
    • /
    • pp.1-18
    • /
    • 2017
  • In this study, reuse of biologically treated wastewater of denim washing and dyeing industry has been evaluated by membrane technologies. After that experiments were carried out at laboratory scale in textile dyeing unit by using obtained permeate water samples on 100% cotton based raw fabric belonging to examined industry. During membrane experiments, two different UF (UC100 and UC030) and two different NF (NP010 and NP030) were evaluated under alternative membrane pressures. In permeate water obtained on selected samples, conductivity at the range of $1860-2205{\mu}S/cm$, hardness at the range of 60 to 80 mg/L, total color at the range of 2.4 to 7.6 m-1 and COD at the range of 25-32 mg/L was determined. The following analyzes were performed for the dyed fabrics: perspiration fastness, rub fastness, wash fastness, color fastness to water, color fastness to artificial light, color measurement through the fabric. According to analysis results, selected permeate water have no negative impact on dyeing quality. The study showed that membrane filtration gave good performance for biologically treated textile wastewater, and NF treatment with UF pre-treatment was suitable option for reuse of the effluents.

Use of laminar flow water storage tank (LFWS) to mitigate the membrane fouling for reuse of wastewater from wafer processes

  • Sun, Darren Delai;Wu, You
    • Membrane and Water Treatment
    • /
    • 제3권4호
    • /
    • pp.221-230
    • /
    • 2012
  • This study employed the modified fouling index (MFI) to determine the performance of a two-step recycling system - a membrane filtration integrated laminar flow water storage (LFWS) tank followed by an ion exchange process to reclaim ultrapure water (UPW) from the wastewater generated from semiconductor wafer backgrinding and sawing processes. The first step consisted of the utilization of either ultrafiltration (UF) or nanofiltration (NF) membranes to remove solids in the wastewater where the second step consisted of an ion exchanger to further purify the filtrate. The system was able to produce high purity water in a continuous operating mode. However, higher recycling cost could be incurred due to membrane fouling. The feed wastewater used for this study contained high concentration of fine particles with low organic and ionic contents, hence membrane fouling was mainly attributed to particulate deposition and cake formation. Based on the MFI results, a LFWS tank that was equipped with a turbulence reducer with a pair of auto-valves was developed and found effective in minimizing fouling by discharging concentrated wastewater prior to any membrane filtration. By comparing flux behaviors of the improved system with the conventional system, the former maintained a high flux than the latter at the end of the experiment.