• 제목/요약/키워드: waste treatment facilities

검색결과 189건 처리시간 0.034초

악취의 시공간적 발생 특성 및 분포도 분석 - 강원지역을 대상으로 - (A Study on the Characteristics and Distribution of the Time-Spatial Occurrence of Offensive Odors -Gangwon Province -)

  • 김병욱;현근우;배선학;홍영균;이영섭;이건호;허인량;최승봉
    • 한국환경보건학회지
    • /
    • 제46권4호
    • /
    • pp.376-387
    • /
    • 2020
  • Objectives: This study is aimed at offering basic data for making plans for offensive odor management after researching offensive odor occurrence and characteristics in Gangwon Province. Methods: The data used in the study is based on offensive odor data analyzed by the Gangwon Institute of Health and Environment from 2012 to 2019. The data were reclassified by year, month, facility, and region to identify characteristics of occurrence. Finally, a distribution map of offensive odors was created using ArcGIS. Results: The highest monthly frequency of offensive odor occurrence falls in June, August, and July, and the summer season and third quarter are the highest. According to the latest eight-year data for Gangwon Province, complaints about offensive odors in county areas are more frequent than those in city areas. There are many offensive odor complaints in Wonju, Cheorwon, and Heongsung. The main offensive odor emission facilities are livestock and waste treatment (recycling) facilities. Complaints about offensive odors are relatively lower the Yeongdong area than Yeongseo area, which is considered to be the result of characteristics of land-sea breezes and geographical factors. Offensive odors from livestock facilities count for an average of 53.9% of the total, and the inadequacy rate of livestock facilities averages 36.9%. Conclusions: To maintain a clean environment in Gangwon Province, it is strongly recommended that an offensive odor reduction plan for livestock facilities be established. Areas with a high density of offensive odor occurrence should be identified and systematically managed with short- and mid-term measures. If offensive odors is managed using GIS, it is possible to identify the characteristics of occurrence by time and space and also by facility. In addition, since systematic data management is possible, it is believed that a rapid response to offensive odors, prediction of their spread, and efficient management are possible.

지렁이 퇴비화 운영사례 및 개선방향 (Current Status and future of Vermicomposting Industry in Korea)

  • 김종오;이창호;최훈근
    • 유기물자원화
    • /
    • 제9권4호
    • /
    • pp.89-98
    • /
    • 2001
  • 2003년과 2005년 각각 하수슬러지 및 음식물쓰레기 직매립이 금지되는 시기에 지렁이를 이용한 유기성폐기물처리기술은 환경 친화적 처리방법으로 유기성폐기물 처리비용적 측면에서도 매우 저렴한 처리방법으로 이용되고 있는 기술이다. 그러나 지렁이 이용기술은 도입초기의 이용기술이 현재에도 적용되고 있으며, 체계적인 연구 및 정책적인 지원의 부족 등으로 지렁이 퇴비화 산업의 발전에 많은 영향을 미치고 있다. 따라서 향후 지렁이 이용기술의 보급과 아울러 지렁이 퇴비화 산업의 발전을 위하여 기술적인 문제점인 과대한 사육부지이용 및 처리공정의 자동화 연구가 필요할 것으로 판단된다. 또한 지렁이 이용기술의 체계적인 연구와 국가적 차원의 정책적인 지원방안이 필요하다.

  • PDF

막여과 정수처리공정에서 망간에 의한 막오염 특성 및 화학세정효율 평가 (Evaluation of membrane fouling characteristics due to manganese and chemical cleaning efficiency in microfiltration membrane process)

  • 강준석;박서경;송지영;정아영;이정준;김한승
    • 상하수도학회지
    • /
    • 제31권6호
    • /
    • pp.539-549
    • /
    • 2017
  • In water treatment process using microfiltration membranes, manganese is a substance that causes inorganic membrane fouling. As a result of analysis on the operation data taken from I WTP(Water Treatment Plant), it was confirmed that the increase of TMP was very severe during the period of manganese inflow. The membrane fouling fastened the increase of TMP and shortened the service time of filtration or the cleaning cycle. The TMP of the membrane increased to the maximum of $2.13kgf/cm^2$, but it was recovered to the initial level ($0.17kgf/cm^2$) by the 1st acid cleaning step. It was obvious that the main membrane fouling contaminants are due to inorganic substances. As a result of the analysis on the chemical waste, the concentrations of aluminum(146-164 mg/L) and manganese(110-126 mg/L) were very high. It is considered that aluminum was due to the residual unreacted during coagulation step as a pretreatment process. And manganese is thought to be due to the adsorption on the membrane surface as an adsorbate in feed water component during filtration step. For the efficient maintenance of the membrane filtration facilities, optimization of chemical concentration and CIP conditions is very important when finding the abnormal level of influent including foulants such as manganese.

바이오가스 이용 기술지침 마련을 위한 연구(II) - 정밀모니터링 결과 중심으로 (A Study on Establishment of Technical Guideline of the Installation and Operation for the Biogas Utilization of Power generation and Stream - Results of the Precision Monitoring)

  • 문희성;배지수;박호연;전태완;이영기;이동진
    • 유기물자원화
    • /
    • 제26권1호
    • /
    • pp.65-78
    • /
    • 2018
  • 본 연구는 유기성폐자원(가축분뇨, 음식물류폐기물, 음식물류폐수 등)의 바이오가스 이용에 대한 적정 설계 및 운전 기술지침서 마련하고자 현장조사와 정밀모니터링 등을 실시하였다. 정부의 중장기 바이오가스화 정책에 따라 폐자원의 자원화 시설 확충이 활발히 추진되고 있다. 하지만 생산된 바이오가스를 이용하여 발전 및 스팀으로 활용하는 시설은 효율이 아직은 저조하고 잦은 고장이 발생되고 있다. 전국 11개소 유기성폐자원 바이오가스화 시설을 대상으로 정밀모니터링을 실시하였다. 사계절 평균으로 정밀모니터링 결과를 정리하였을 때, 유기성폐자원 별 효율성 분석에서 유기성분해율은 VS기준 음식물/음폐수는 68.2 %, 가축분뇨는 66.8 %, 하수슬러지의 경우 46.2 %로 전체 평균 58.8 %로 분석되었다. 전처리 전후 바이오가스 성상을 분석한 결과 철염 및 탈황(건식, 습식)을 이용하여 전체 시설의 $H_2S$ 평균은 560 ppm으로 측정되었으며, 저감효율이 90% 이상인 경우 약 40 ppm 까지 감소할 수 있는 것을 확인하였다. 특히 소화조 내에 철염을 투입하면 처리효율 약 93 %이며, 평균 150 ppm까지 감소하는 것을 확인하였다. 제습의 경우 노점온도를 적용한 절대습도와 가스온도에 따른 상대습도를 분석하였으며, 제습설비가 유지보수가 잘되어 가동 중인 시설의 노점온도는 $14^{\circ}C$, 절대습도는 $12.6g/m^3$이며, 상대습도는 35 %로 측정되었다. 따라서 유기성폐자원의 바이오가스화 시설의 단점을 보완하고 바이오가스 이용 최적화 방안을 마련하기 위하여 정밀모니터링을 실시하였다.

보육시설 급식운영관리 실태 조사 (Assessment of Foodservice Management Performance at Child Care Centers)

  • 이미숙;이재연;윤선화
    • 대한지역사회영양학회지
    • /
    • 제11권2호
    • /
    • pp.229-239
    • /
    • 2006
  • This study was carried out to investigate foodservice management practices of 100 child care centers nationwide, and to provide background information for developing foodservice management policies at child care centers. Approximately 20% of the child care centers had a separate dining room; most of the centers were vulnerable to sanitation or safety problems. The percentage of the centers that planned menus was about 60% and 10% established standardized recipes. Fourteen percent of the centers kept records for distribution and menu evaluation and 33% kept sanitation management records. Since only 7% of the centers employed a dietitian, foodservice in most centers were not managed by professionals. The results of menu assessment revealed that 56.5% of the national/public child care centers received 19 points or higher out of 21 points, whereas 5.6% of the private child care centers received the same scores. Proper usage and storage of raw food, sanitary management of equipment and facilities, waste management/leftover food treatment, and basic facility of cooking zones were performed well by many centers. The overall scores of foodservice performance were only 31.2 out of 60 points, representing relatively poor safety management, food procurement management, and facilities and equipment management. These results indicate that the foodservice management of the child care centers are in a relatively poor state. Since nutrition management of the most centers was performed by non-professionals, it may not be possible to provide proper nutrition for health and normal growth of preschool children and to perform efficient nutrition education programs. The following suggestions are strongly recommended in order to improve foodservice performance at child care centers. First, foodservice administration should be performed by a dietitian, and second, efforts should be focused on strengthening nutrition and sanitation management.

건설폐기물 재활용 2차 제품에 대한 확률모델 기반 비용분석 (Probability-based Cost Analysis for Recycling Secondary Products from Construction Waste)

  • 권기현;김도겸;이호재;서은아
    • 한국건설순환자원학회논문집
    • /
    • 제8권2호
    • /
    • pp.227-234
    • /
    • 2020
  • 본 연구에서는 토목건설 분야에서 활용 가능한 폐기물 재활용 2차 제품 후보군 각각에 대한 비용분석 결과를 제시하였다. 각각의 비용 항목에 내재된 불확실성을 고려하여 확률모델 기반 비용 분석을 수행하였으며, 2차 제품 제작에 의해 발생하는 이익 비용을 제시하였다. 폐기물 재활용 시 각각의 공정별 투입 비용 발생은 불가피하며, 이는 2차 제품 대상 후보군별로 달라지는데 제품별 실용화에서 경제성 확보를 위해서는 제품 품질향상 뿐만 아니라 투입 비용의 정확한 산정이 요구된다. 본 연구에서는 폐기물 재활용에 따른 비용분석을 통해 제품별 발생 가능한 이익과 이익발생 확률 산정법을 제시하였다. 재활용 비용분석 항목으로 폐기물 분류 비용, 재활용 처리시설로의 운반비용, 재활용 제품생산비용 등을 고려하였으며, 또한 재활용 제품생산에 따른 이익분석을 위해 폐기물이 재활용 되지 못하고 폐기될 경우와 재활용될 경우를 서로 비교하여 그 차이를 이익으로 환산하여 추정하였다. 건설폐기물 매립지까지 거리가 늘어날수록 재활용에 따른 이익발생이 증가하였고 재활용 시설까지의 거리는 이익발생에 영향을 주었으며, 또한 재활용 제품 선정, 재활용 처리시설의 최적위치 결정, 목표가격 결정 등에 유용하게 활용할 수 있음을 확인하였다.

대청호 정체수역의 수질예측과 관리 (Management of Water Quality of Embayments in Daechong Reservoir)

  • 이종호
    • 환경영향평가
    • /
    • 제3권2호
    • /
    • pp.33-45
    • /
    • 1994
  • Water quality of Chongju and Daejeon Water Intake Tower Region, embayments in Daechong Reservoir was found to be worse than that of main lake after analysis of water which were sampled during April, July, October in 1993. Concentration of COD and SS at those two water intake tower sites were 2.8-5.6 mg/l and 2.2-3.2 mg/l, higher than that of main lake. T-N concentration of those two sites was 1.1-1.9 mg/l similar to that of main lake, and T-P concentration of those two sites was 0.14-0.18 mg/l, higher than that of main lake. This study used water quality model of embayment which can analyse pollutant loads from stream and surrounding land use, advection, decay, and diffusion transport between embayment and main lake. The model can predict water quality of embayment according to the change of pollutant load, water elevation of embayment, quantity of water intake in order to suggest water quality management. This study suggests embayment water quality management alternatives, 1) construction of waste water treatment facilities at embayment and main lake for the decrease of pollutant loading, 2) water intake at main lake less polluted or eutrophicated than embayment, and 3) outflow elevation selection for polluted hypolimnion water outflow during stratification.

  • PDF

해체 데이터베이스 개념적 모델링 및 정보 분류 체계 확립 (Establishment of the Classification scheme and Conceptual Modeling on the Decommissioning Database)

  • 박희성;박승국;정기정;장세규
    • 한국에너지공학회:학술대회논문집
    • /
    • 한국에너지공학회 2002년도 춘계 학술발표회 논문집
    • /
    • pp.43-48
    • /
    • 2002
  • 연구로 1호기와 2호기의 해체 DB 구축을 위한 정보전략계획(ISP: Information Strategy Planning)연구가 수행되었다. 해체 DB 구축 범위를 설정하기 위해 사용자 요구사항과 정보 자료 중요도를 분석하였고, 해체 DB 개념을 정립하였으며, 해체와 관련한 정보 및 자료들의 분류 체계를 확립하였다. 해체와 관련한 20여종의 자료 수집과 연구로 1, 2호기 시설방문을 통한 시설조사 및 현황, 그리고 연구로 해체 설계자와 방사성폐기물 관리 전문가, 방사선안전관리 전문가와의 면담을 통하여 해체 시설정보, 작업자 정보, 폐기물 정보, 그리고 방사선학적 정보를 도출하였다. 또한 해체 정보들을 코드화하였다. 연구를 통하여 얻어진 해체 데이터 모델링 결과와 해체 정보들에 대한 분류 체계 결과는 해체 DB Prototype 설계를 위한 기초자료로 활용될 것이다.

  • PDF

터널 굴착시 발생하는 지하수의 유출량 예측에 관한 연구 (A Study on the Prediction of Outflow of Groundwater in Tunnel Construction Areas)

  • 박선환;장윤영;강형식;최준규;양근호
    • 환경영향평가
    • /
    • 제16권6호
    • /
    • pp.407-419
    • /
    • 2007
  • This study investigated the predicted and abserved outflow of groundwater which occurred during tunnel constructions. Among the 586 road construction projects from 1986 to 2006, 4 route 25 tunnel construction areas and 26 waste water treatment facilities under construction were studied. Most of the tunnel outflow prediction in EIA (Environmental Impact Assessment) process have been classified into the 17 types of units depending on the assessor's options, which have not conformed to the request of the residents and non government organizations. The investigation results showed that the outflow of underground water in tunnel construction areas averaged about $0.133m^3/km{\cdot}min$ with the maximum $0.386m^3/km{\cdot}min$, and that the outflow mostly occurred in the early stage of tunnel excavation and diminished gradually. The prediction of outflow of underground water in the EIA process showed excessive results compared to observed outflow, the even 51.7 times. Consequently for more realistic prediction, current EIA method for prediction of outflow of underground water in tunnel construction areas has to adopt numerical methods coupled with hydraulics and geologic informations from unit methods of present time.

산업폐수의 수처리를 위한 초전도 자기분리 장치 제작 (Superconducting Magnetic Separator for Purification of Industrial Wastewater)

  • 하동우;권준모;고락길;백승규;손명환;이유진;김태형
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2010년도 하계학술대회 논문집
    • /
    • pp.44-44
    • /
    • 2010
  • Conventional water treatment facilities like precipitation process need large-scale equipment and wide space to purify the wastewater of paper factory. In case of massive waste water, high gradient magnetic separation (HGMS) parts are more effective to purify it rapidly and to occupy relatively small space, since large voids at filter with HGMS are adopted. Cryo-cooled Nb-Ti superconducting magnet with room temperature bore in diameter of 100 mm and 600 mm in height was used for magnetic separator. Magnetic filters were designed by the analysis of magnetic field distribution at superconducting magnets.

  • PDF