• Title/Summary/Keyword: waste disposal

Search Result 1,467, Processing Time 0.026 seconds

Relationship of Ceramic Insulation Panel System Development and Verification of LCC

  • Han, Min-Cheol;Jeon, Kyu-Nam;Lee, Gun-Cheol;Kim, Tae-Hui
    • Journal of the Korea Institute of Building Construction
    • /
    • v.12 no.4
    • /
    • pp.386-392
    • /
    • 2012
  • In this study, life cycle cost (LCC) is analyzed according to insulation panel system type using a deterministic LCC analysis method. Through this analysis, it was found that the construction cost in the deterministic LCC analysis for Ceramic panels was low compared to the construction cost for metal and stone panels. Also, the difference in cost between the Ceramic panel and the metal panel was about 2 times. In the area of maintenance cost, it was found to be similar to the previously analyzed construction cost, in which the metal panel has the highest cost due to the high cost of construction and the frequent need for maintenance. In the case of the stone panel, a small difference in cost is shown compared with that of the Ceramic panel, but the cost is higher than the Ceramic panel. Regarding the cost of waste disposal, the Ceramic panel can reduce the cost by at least 1.5 times and up to 2 times compared to other panel systems. Finally, in the analysis of sensitivity according to changes in discount rates, the Ceramic panel and metal panel systems have a similar cost, and the cost of the metal panel is a bit larger than that of other panel systems. Thus, in the subjects used in the analysis, the Ceramic panel system shows the highest economic benefits.

Current Status of Infection Prevention and Control Programs for Emergency Medical Personnel in the Republic of Korea

  • Oh, Hyang Soon;Uhm, Dong Choon
    • Journal of Preventive Medicine and Public Health
    • /
    • v.48 no.6
    • /
    • pp.330-341
    • /
    • 2015
  • Objectives: Emergency medical personnel (EMPs) are pre-hospital emergency responders who are at risk of exposure to infections and may also serve as a source for the transmission of infections. However, few studies of infection control have specifically addressed EMPs in the Republic of Korea (hereafter Korea). The goal of this study was to assess the current status of infection prevention and control programs (IPCPs) for EMPs in Korea. Methods: A cross-sectional survey was conducted to quantitatively assess the resources and activities of IPCPs. A total of 907 EMPs in five metropolitan cities completed a structured questionnaire from September 2014 to January 2015. The data were analyzed using descriptive statistics, multi-response analysis, and the chi-square test. Results: The mean age of the participants was $34.8{\pm}15.1years$. IPCPs were found to have weaknesses with regard to the following resources: the assignment of infection control personnel (ICP) (79.5%), hand hygiene resources such as waterless antiseptics (79.3%), the use of paper towels (38.9%), personal protective equipment such as face shields (46.9%), and safety containers for sharps and a separated space for the disposal of infectious waste (10.1%). Likewise, the following activities were found to be inadequately incorporated into the workflow of EMPs: education about infection control (77.5%), post-exposure management (35.9%), and the decontamination of items and spaces after use (88.4%). ICP were found to have a significant effect on the resources and activities of IPCPs (p<0.001). The resources and activities of IPCPs were found to be significantly different among the five cities (p<0.001). Conclusions: IPCPs for EMPs showed some limitations in their resources and activities. IPCPs should be actively supported, and specific IPCP activities for EMPs should be developed.

Applying a Life-Cycle Assessment to the Ultra Pure Water Process of Semiconductor Manufacturing

  • Tien, Shiaw-Wen;Chung, Yi-Chan;Tsai, Chih-Hung;Yang, Yung-Kuang;Wu, Min-Chi
    • International Journal of Quality Innovation
    • /
    • v.6 no.3
    • /
    • pp.173-189
    • /
    • 2005
  • A life-cycle assessment (LCA) is based on the attention given to the environmental protection and concerning the possible impact while producing, making, and consuming products. It includes all environmental concerns and the potential impact of a product's life cycle from raw material procurement, manufacturing, usage, and disposal (that is, from cradle to grave). This study assesses the environmental impact of the ultra pure water process of semiconductor manufacturing by a life-cycle assessment in order to point out the heavy environmental impact process for industry when attempting a balanced point between production and environmental protection. The main purpose of this research is studying the development and application of this technology by setting the ultra pure water of semiconductor manufacturing as a target. We evaluate the environmental impact of the Precoat filter process and the Cation/Anion (C/A) filter process of an ultra pure water manufacturing process. The difference is filter material used produces different water quality and waste material, and has a significant, different environmental influence. Finally, we calculate the cost by engineering economics so as to analyze deeply the minimized environmental impact and suitable process that can be accepted by industry. The structure of this study is mainly combined with a life-cycle assessment by implementing analysis software, using SimaPro as a tool. We clearly understand the environmental impact of ultra pure water of semiconductor used and provide a promotion alternative to the heavy environmental impact items by calculating the environmental impact during a life cycle. At the same time, we specify the cost of reducing the environmental impact by a life-cycle cost analysis.

Ammonium Chloride Solution Leaching of Crude Zinc Oxide Recovered from Reduction of EAF′s Dust

  • Youn, Ki-Byoung
    • Proceedings of the IEEK Conference
    • /
    • 2001.10a
    • /
    • pp.365-369
    • /
    • 2001
  • EAF's dust has been treated mainly by pyrometallurgical reduction process in rotary kiln furnace to recover valuable metal elements such as Zn and to avoid the disposal of hazardous materials to waste. Recently, hydrometallurgical eletrowinning of zinc from a zinc-amino chloride solution obtained by the leaching of EAF's dust was developed to recover high grade zinc metal from EAF’s dust. But there are some disadvantages in each process such as difficulty of operation condition control and sticking problem in kiln process and low extractability and recovery of zinc owing to insoluble zinc-ferrite in electrowinning process. We propose a new combined process of pyrometallurgical one and hydrometallurgical one to treat EAF's dust efficiently and economically. In this study, ammonium chloride solution leaching of crude zinc oxide recovered from reduction of EAF's dust was carried out to find out the efficiency of zinc extraction from it and the possibility for performance of eletrowinning in the proposed process. Effects of various leaching variables ruck as leaching temperature, concentration of leaching solution and leaching time were investigated. And the leaching results of the crude zinc oxide were compared with those of EAF's dust. The extraction percents of zinc in ammonium chloride solution leaching of the crude zinc oxide recovered from reduction of EAF's dust were above 80% after 60 minutes of leaching under the leaching condition of 4M NH$_4$CI concentration and above leaching temperature of 7$0^{\circ}C$. And the concentrations of zinc in the leached solution were obtained above 50g/$\ell$. The activation energy calculated for zinc extraction in NH$_4$CI leaching was 58.1 KJ/㏖ for EAF's dust and 15.8 KJ/㏖ for the crude zinc oxide recovered from reduction of EAF's dust.

  • PDF

Feasibility test on EDZ detection by using borehole radar survey

  • Cho, Seong-Jun;Kim, Jung-Ho;Son, Jeong-Sul;Kim, Chang-Ryol;Sugn, Nak-Hun
    • 한국지구물리탐사학회:학술대회논문집
    • /
    • 2006.06a
    • /
    • pp.239-244
    • /
    • 2006
  • Borehole radar reflection surveys were carried out in the horizontal borehole to detect EDZ while constructing the tunnel for the research facility of the nuclear waste disposal in Korea. The horizontal borehole has been bored at a length of 35 m from shelter to be parallel with the tunnel which would be planed. While the tunnel has been constructing with the explosive excavation, the borehole radar reflection surveys carried out 5 times with the interval of 2 or 4 days for monitoring EDZ. The most typical change of the reflection event resulted from the face of the wall of tunnel which had been produced newly by the excavation of the tunnel daily, EDZ has been detected with constructing images of difference between two measurement stages, and also the change of EDZ through the time has been done, which is due to the generation of crack and weakening of the rock strength of the face of the tunnel's wall near previous portion of the face of a blind end of tunnel according to explosive excavation.

  • PDF

Adsorption of Heavy Metals Cd, Cu and Zn on Peat (Peat에 의한 중금속(重金屬) Cd, Cu, Zn의 흡착(吸着))

  • Han, Kang-Wan;Choi, Hyun-Ok
    • Korean Journal of Environmental Agriculture
    • /
    • v.11 no.3
    • /
    • pp.195-200
    • /
    • 1992
  • Heavy metal adsorption on peat was studied to examine the utilization of abundant natural resouces as pollution control. The smaller the peat particle size, the more the heavy metals studied were adsorbed. Adsorption of heavy metals on peat was greater in single metal solutions than in mixed solutions, and the order of adsorption amount on peat was Cu > Cd > Zn. The most effective pH range of the adsorption of Cd, Zn, and Cu was between 4 and 6. With increasing the concentration of heavy metals the amount of adsorption on peat was increased, but the adsorption ratio was decreased. The adsorption of heavy metals on peat was fitted to the Freundlich isotherm and peat was appeared to be an effective adsorbent of the heavy metals. The treatment of polyethyleneimine(PEI) on the peat surface effectively increased adsorption capacity of the heavy metals. Because of its higher energy content, the heavy metal adsorbed peat could be utilized as a energy source. After burning the peat, the reduced peat volume could be save the expenses for waste disposal.

  • PDF

A Methodology to Formulate Stochastic Continuum Model from Discrete Fracture Network Model and Analysis of Compatibility between two Models (개별균열 연결망 모델에 근거한 추계적 연속체 모델의 구성기법과 두 모델간의 적합성 분석)

  • 장근무;이은용;박주완;김창락;박희영
    • Tunnel and Underground Space
    • /
    • v.11 no.2
    • /
    • pp.156-166
    • /
    • 2001
  • A stochastic continuum(SC) modeling technique was developed to simulate the groundwater flow pathway in fractured rocks. This model was developed to overcome the disadvantageous points of discrete fracture network(DFN) modes which has the limitation of fracture numbers. Besides, SC model is able to perform probabilistic analysis and to simulate the conductive groundwater pathway as discrete fracture network model. The SC model was formulated based on the discrete fracture network(DFN) model. The spatial distribution of permeability in the stochastic continuum model was defined by the probability distribution and variogram functions defined from the permeabilities of subdivided smaller blocks of the DFN model. The analysis of groundwater travel time was performed to show the consistency between DFN and SC models by the numerical experiment. It was found that the stochastic continuum modes was an appropriate way to provide the probability density distribution of groundwater velocity which is required for the probabilistic safety assessment of a radioactive waste disposal facility.

  • PDF

Borehole Heater Test at KAERI Underground Research Tunnel (지하처분연구시설(KURT)에서의 시추공 히터 시험)

  • Kwon, S.;Lee, C.;Yoon, C.H.;Jeon, S.W.;Cho, W.J.
    • Tunnel and Underground Space
    • /
    • v.21 no.3
    • /
    • pp.225-234
    • /
    • 2011
  • In this study, an in situ heater test for investigating the thermo-mechanical behavior related to heat flow was carried out. It was the first in situ heater test in Korea. For the test, an adequate design of heater, observation sensors, and data logging system was developed and installed with a consideration of the site condition and the test purposes. It was possible to observe that steep joints are overwhelmingly developed in the test area from a joint survey. The major rock and rock mass properties at the test site could be determined from the thermal and mechanical laboratory tests using the rock cores from the site. From the measured rock temperature distribution, it was possible to observe the influence of the rock joints and the heat flow through tunnel wall. When the heater temperature was maintained as $90^{\circ}C$, the rock temperature at 0.3 m from the heater hole was increased up to $40^{\circ}C$.

Studies on the Improvement of Butt Welding Characteristic of Polyethylene Pipes (PE 이중벽관의 맞대기 융착 용접 강도 향상에 관한 연구)

  • An, Ju-Seon;Lee, Kyng-Won;Kim, Jae-Sung;Lee, Bo-Young
    • Journal of Welding and Joining
    • /
    • v.29 no.1
    • /
    • pp.85-89
    • /
    • 2011
  • Waste water is disposed to sewage disposal plant by underground PE double wall pipes. Various processes have been introduced to join PE pipes, but most of these methods have many disadvantages such as costs, lack of reliability and difficulties in joining, etc. Recently butt welding has been paid much attention to joint PE pipes as this process has many advantages such as cost, safety and reliability. In this study, newly developed heat plate, a patent-pending heat plate with a groove, was used to butt-weld PE double wall pipes with different misalignment gaps to simulate real underground conditions, and the butt welding temperature of PE pipe was determined by thermal analysis (Thermal Gravimetric Analysis, Differential Scanning Calorimetry and Dynamic Mechanical Analysis). The resulting joining characteristics of double wall pipes were compared with those from a conventional heat plate, in terms of stiffness, flattening and leakage tests. The results from the stiffness and flattening test showed that there were no big differences between the butt-welded joints made from these two plates. From the leakage test, although PE pipes welded with a conventional heat plate did leak below the required test conditions (10 min. at 0.75kgf/cm2), the pipes welded with a patent-pending grooved heat plate did not show any leakage even at a pressure 1.5 times higher than the required conditions. It was noted that by utilizing a grooved heat plate more complete fusion at the pipe joints could be obtained, which in turn induced a high quality joints.

Characteristics of Malodor Pollutants and Their Dispersion Measured in Several Industrial Source Regions in Yangsan (양산시 산업단지에서 측정한 악취물질의 농도 분포 특성 및 대기확산 모델링)

  • Song, Sang-Keun;Shon, Zang-Ho;Kim, Yoo-Keun;Park, Heung-Jai
    • Journal of Environmental Science International
    • /
    • v.18 no.10
    • /
    • pp.1103-1114
    • /
    • 2009
  • In this study, the environmental behavior of malodor pollutants (MPs: $H_2S$, $CH_3SH$, DMS, and DMDS) was investigated around areas influenced by strong anthropogenic processes based on observations and modeling study (a CALPUFF dispersion model). The MP emission concentrations were measured from 8 industrial source regions (tire plants (S1-S3), waste water disposal plant (S4), and oil refinery (S5) in an urban center area and paper mill/incineration plant (S6) and livestock feedlots (S7-S8) in Ungsang area) in Yangsan city during a fall period in 2008 (21 October 2008). Overall, the most MPs emitted from the urban center area were found to affect the malodor pollution in their downwind areas during early morning (06:00 LST) and nighttime (18:00 and 21:00 LST), compared with those in the Ungsang area. For malodor intensity, the most MPs in the urban center area (especially S1 and S2) were found to be a significant contributor, whereas $CH_3SH$ and $H_2S$ in the Ungsnag area (especially S6) were the dominant contributor. The model study showed agreement in the spatial distributions of simulated MPs with those of the observations. The largest impact of MPs in the urban center area on the malodor pollution in its residential areas occurred at S1, S2, and S3 sites during nighttime, while that of MPs in the Ungsang area occurred at S6 and S8 sites. This may be caused mainly by the high MP emissions and in part by wind conditions (prevailing northeasterly winds with low wind speeds of 2-3 m/s).