• Title/Summary/Keyword: washing-machines

Search Result 76, Processing Time 0.027 seconds

Efficiency Improvement for Concentrated Flux IPM Motors for Washing Machines

  • Yoon, Keun-Young;Kwon, Byung-Il
    • Journal of Electrical Engineering and Technology
    • /
    • v.9 no.4
    • /
    • pp.1277-1282
    • /
    • 2014
  • Concentrated flux interior permanent magnet (CFIPM) motors have the advantage that their utilization of flux linkage is more efficient than that of general IPM motors and CFIPM motors are suitable for washing machine motors, which demand low-speed, high-torque specifications. However, low efficiency occurs in the low-speed high-torque mode considering the high-speed operation for spin mode. This paper proposes a magnet overhang structure between the rotor core that reduces leakage flux and improves efficiency for a CFIPM in wash mode. Optimization of the 3D design of magnet overhang structures is performed to improve the efficiency with the same quantity of permanent magnets. The validity of the optimal design is experimentally verified through the fabrication of prototypes.

A Study on the Evaluation of Water Consumption in Electric Appliances using Water Footprint - Focusing on Washing Machine - (Water Footprint 개념을 이용한 가전제품의 수자원 사용량 산정 (세탁기를 중심으로))

  • Jo, Hyun-Jung;Kim, Woo-Ram;Park, Ji-Hyoung;Hwang, Young-Woo
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.25 no.5
    • /
    • pp.691-697
    • /
    • 2011
  • In this study, by using the Water footprint technique, the water consumption by washing machines, which holds higher ranks in using water than any other electric appliances, was analyzed during their life cycle. The life cycle is defined as raw materials production step, manufacturing step, and using step. In raw materials production step, Input materials were researched by using LCI DB(Life Cycle Inventory Database) and the water consumption was calculated with consideration of approximately 65% Input materials which were based weight. In manufacturing step, the water consumption was calculated by the amount of energy used in assembly factories and components subcontractors and emission factor of energy. In using step, referring to guidelines on carbon footprint labeling, the life cycle is applied as 5 years for a washing machine and 218 cycles for annual bounds of usage. The water and power consumption for operating was calculated by referring to posted materials on the manufacture's websites. The water consumption by nation unit was calculated with the result of water consumption by a unit of washing machine. As a result, it shows that water consumption per life cycle s 110,105 kg/unit. The water consumption of each step is 90,495 kg/unit for using, 18,603 kg for raw materials production and 1,006 kg/unit for manufacturing, which apparently shows that the using step consume the most water resource. The water consumption by nation unit is 371,269,584tons in total based on 2006, 83,385,649 tons in both steps of raw material production and manufacturing, and 287,883,935 tons in using step.

Fabrication and Simulation of Displacement Properties of Ultrasonic Generator Handpiece (초음파 절삭기 핸드피스부 제작 및 변위 특성 시뮬레이션)

  • Kim, Seung-Won;Yoo, Ju-Hyun;Lee, Jie-Young
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.31 no.3
    • /
    • pp.152-155
    • /
    • 2018
  • Ultrasonic wave technologies have been widely used in ultrasonic washing machines, ultrasonic surgery, ultrasonic welding machines, ultrasonic sensors, and medical instruments. Ultrasonic surgery can be realized through the cavitation effect of ultrasonic waves. In this study, piezoelectric ceramics were manufactured to achieve the optimum design of a piezoelectric vibrator in a handheld generator for ultrasonic surgery. The best specimen showed the excellent piezoelectric properties of kp=0.624, Qm=1,531, and $d_{33}=356pC/N$. Numerical modeling based on the finite element method was performed to find the resonance frequency, the anti-resonance frequency, and the displacement properties of the handheld ultrasonic generator. Maximum displacement was observed in the six-step piezoelectric vibrator at $6.36{\mu}m$.

Analysis of microplastics released from textiles according to filter pore size and fabric weight during washing (세탁 중 세탁물 중량과 여과 기공 크기에 따른 미세플라스틱 분석)

  • Choi, Sola;Kwon, MiYeon;Park, Myung-Ja;Kim, Juhea
    • Journal of the Korea Fashion and Costume Design Association
    • /
    • v.23 no.1
    • /
    • pp.37-45
    • /
    • 2021
  • This study observed the release of microplastics according to washing weights and filtering conditions, measured microplastic generation rates, fiber lengths, and fiber diameters. This study attempted to present data for the development of filters that decrease microplastic generation. For test samples, polyester piled knit fabric (cut-pile) was selected, which currently has the highest amount of consumption in the clothing industry, but can easily cause marine pollution because of its low biodegradability. For test equipment, a drum washer was used and microplastics were collected using two filter pore sizes, 5 ㎛ and 20-25 ㎛. Microplastic fibers weights and lengths were measured. The results of the experiment showed the following: 1) The release of microplastics differed according to the fabric weights and washing process; 2) washing fabric weights showed a differences in the collection amount according to the filter pore size (5 ㎛, 20-25 ㎛); 3) observations of differences in the lengths of the microplastics that occur during the washing process by filter pore size were made. Fibers with shorter lengths appeared with filter pore sizes of 5㎛ in comparison to filter pore sizes of 20-25㎛. The results from this study on microplastic generation by fabric during washing, demonstrated the following conclusions that can be used to reduce the release of microplastics. First, the release of microplastics according to fabric weights and washing courses are affected by physical force. Therefore, it is necessary to reduce the amount of physical force due to water flow, increase the fabric weight, or wash the material in low temperatures. Second, in the manufacturing of washing machines, microplastic filtration can be promoted or legislatation supporting microplastic filtration can be introduced.

Analytical studies of bovine mastitis management by standard plate counts(SPC) and somatic cell counts(SCC) (젖소 유방염 관리에 따른 세균 및 체세포수 등급 실태 조사 분석)

  • 허정호;정명호;박영호;조명희;이주홍
    • Korean Journal of Veterinary Service
    • /
    • v.21 no.3
    • /
    • pp.285-300
    • /
    • 1998
  • 1. The number of average milking cows, clinical forms of mastitis, mastitis-developing cows, and cows killed by mastitis a year were 25.7, 1.8(7%), 6.3(26%), and 2.7(10.1%)heads, respectively. The annual grade changes of standard plate counts(SPC) and somatic cell counts(SCC) showed the grade 1A of SPC diminished sharply from April to August, we think it was due to the lack of proper management in farming season and the grade 3 of SCC indirectly influenced increased in huge during August. 2. The average number of parturitions of farms was 2.3, but 50% of below 1 parturition were 22 farms(31%), 50% of above 3 parturitions were 16(23%) out of 71 farms. According to grades of the number of parturitions of milking cows per each farm, the farms' grades recording 3 parturitions and 50% were little bit excellent. 3. The actual situation research of foremilking CMT revealed 35 out of 74 farmer didn't do CMT Among them(35 out of 74 farmers), 80% did not test thanks to the troublesome process of the CMT. SCC grade 3, among farms who did foremilking CMT once or twice a month and who did not were 29% and 40% respectively and SPC grade 1A were 55% and 9%, respectively. 4. The research of actual situation on milking management let us know 29 farms(39%) did not do lastmilking, 37 farms(49%) usually did overmilking, and 34 farms(46%) did milking for 4 or 5 minutes. Grades according to average requiring times of milking showed SCC grade 1 of farms milking within 7 minutes was 11% and SPC grade 1A was 34%, on the other side, farms milking more than 7 minutes were 0% in SCC grade 1 and 13% in SPC grade 1A. Grades according to the starting time of milking after rubbing teats showed SPC grade 1A of farms starting milking at about 1 minute and over 2 minutes were 50% and 20%, respectively. 5. The research of actual situation on hygienic milking management uncovered 65 farms(88%) were using one towel which was used in washing teats and udders to wash more than 3 to 4 cows, and 53 farms(72%) were using one dried towel to dry udders not for each cow but for more than 3 to 4 cows after washing. Also, on milking turns disclosed 30 farms(40%) were milking cows in the order of incoming without isolation of a dominant group. According to grades of towels used in washing teats and udders, farms using a towel for each cow were 56% and a towel for over 3 cows were 31% in SPC grade 1A. According to using-or-not grades of dried towels after washing udders, farms using a towel for each cow were 79% and a towel for over 3 cows were 21% in SPC grade 1A. 6. Farms doing teat-dipping before milking were 7(10%), not doing teat-dipping after milking, or doing sometimes were 9(12%), and doing right after milking were 57(77%). And farms doing teat-dipping after dry cows and before delivery were 21(28a ). Farms using bethadine as an antiseptic solution were 70(95%), 40 farms(59%) diluted it with water as weak as 5 to 10 times, and on drying cows 64 farms(87%) slowly did it more than 2 days. Grade 1A of SPC of farms doing teat-dipping at every milking was 38%, farms doing occasionally or not was 33%, and farms doing it right after milking was 37% and doing after milking more than 5 cows was 20%. Grade 1A of SPC among farms diluting bethadine 5 times and diluting 5 to 10 times with water were 36% and 33%, respectively, and Grade 3 of SCC were 35% and 32%, respectively. 7. Studies on nonlactating period medical treatment, as the cows were on dry, 54 farms treated with their own hands.73 farms(98%) had bovine mastitis treated for themselves. And on applying medicines against mastitis, 55 farmers chose them on the basis of their own experience, 42 farms(57%) were treated more than 3 days. 41 farms(55%) dumped away the mastitis infected milk separately, 24 farms(32%) were feeding and milking at the same time. 8. Fifty-six farms(76%) always washed and disinfected milking machines after milking. Farms using the milking machines at low, or variable vacuum pressures, or at the vacuum pressure, set at the moment of its installation were 31(42%), and farms that did not know pulsation ratio were 27(37%). Farms changing liners when they were torn 8(11%), 58 farms(78%) said they checked milking system when there were wrong with them, 31 farms(42%) changed milking hoses when they found out problems, and 42 farms(57%) cleaned vacuum and milking systems when they felt dirty. The SPC grade 1A of farms washing and sterilizing milking machines was 38% and farms only washing was 28%.

  • PDF

Drop Analysis of a Package and Cushion Performance of Drum Washing Machine (드럼 세탁기 포장재 낙하해석 및 완충 특성)

  • Kim, Chang-Sub;Bae, Bong-Kook;Sung, Do-Young
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.34 no.11
    • /
    • pp.1733-1740
    • /
    • 2010
  • The analysis of the dynamic behavior of the packaging of a drum washing machine has been carried out under the drop impact conditions. LS-DYNA software is used for performing the finite element analysis, and the validations are performed by comparing with the impact acceleration, effective stress and deformation of cushioned package with high-speed camera during free drop test. By analyzing the cushion characteristics and the design parameters of the original packaging, a packaging with an improved design is developed, and this design is validated on the basis of the results of the distribution test which consists of drop test, vibration test, stacking test, squeez test and so on. The drop impact simulation and analysis methods developed in this study can be adopted to successfully improve the cushioning provided by the packaging and to reduce the cost involved in developing new packaging for drum washing machines.

Analysis of Disinfection Practices in Foodservice Operations According to the Application of Hazard Analysis and Critical Control Point (식품안전관리인증기준 적용 여부에 따른 급식시설의 소독 실태 분석)

  • Park, Min-Seo;Lee, Hye-Yeon;Bae, Hyun-Joo
    • Journal of the FoodService Safety
    • /
    • v.2 no.2
    • /
    • pp.103-110
    • /
    • 2021
  • This study was conducted to compare and evaluate the difference in washing and disinfection when the Hazard Analysis and Critical Control Point (HACCP) protocol was applied to foodservice operations. The results of the survey were as follows: Among the 116 foodservice operations surveyed, 67.2% were HACCP-compliant and 32.8% were not HACCP-compliant. Also, 62.9% served meals once daily, and 79.3% conducted food safety education once a month. Compared to HACCP non-compliant foodservice operations, the disinfection performance of HACCP-compliant operations was significantly better concerning worktables (p<0.001), food inspection tables (p<0.001), preparation tables for distribution (p<0.01), serving tables (p<0.01), overflow and trenches(p<0.05), sinks (p<0.05), and insect attracting lamps (p<0.01). Similarly, the disinfection performance of HACCP-compliant foodservice operations was significantly better for 18 cooking utensils and personal tools such as food slicers (p<0.001), multiple cooking machines (p<0.05), tray carts (p<0.001), stainless steel tools (p<0.001), rubber gloves (p<0.05). Worktables (45.1%), serving tables (29.6%), sinks (37.0%), and scales (21.6%) were most often disinfected 'at the end of each task', while food inspection tables (36.5%), food preparation tables for distribution (31.2%), dish machines (34.2%), overflow and trenches (25.7%), and floors (25.8%) were most often disinfected 'once a day'. All cooking utensils were most often disinfected 'at the end of each task'. 'Chemical disinfection' was most frequently used in all foodservice facilities. To improve the food safety management of foodservice operations, it is necessary to apply the HACCP protocol and comply with the washing and disinfection manual.

A Study of the Salt Rejection from the Surface of Marine Waste using Ultra Fine Bubble (초미세기포를 이용한 해양쓰레기 표면 내 염분제거에 관한 연구)

  • Kim, Bo-Min;Kim, Kwang-Koo;Park, Chan-Gyu
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.22 no.6
    • /
    • pp.11-18
    • /
    • 2021
  • Nano bubble water is used in various washing processes, including cleaning of solar panels, salt rejection of roads, and cleaning precision parts of machines. High cleaning efficiency and water conservation are obtained by applying nano bubbles during pretreatment of the marine waste cleaning system. This study compared the salt rejection of nano bubble water, and it was revealed that marine waste was produced by wood immersed in 200,000 mg/L NaCl solution. Using tap water and nano bubble water for washing, comparisons of the surface salt concentrations of wood were determined according to the nozzle, orifice diameter, pump speed and washing time. Decreased surface salt concentration was observed on the wood surface with increasing washing time. Water consumption was optimal between 5- and 10-seconds washing time. Increasing orifice diameter of the nozzle reduced the spraying pressure, with consequent increase in the wood surface salt concentration, thereby establishing the importance of orifice diameter of the nozzle. Compared to levels obtained with tap water, salt concentration of the wood surface after washing with nano bubble water was 2.2% lower with sector nozzle, and 30.9% lower with circular nozzle. In the washing experiment using nano bubble water, the salt concentration on the wood surface was about 9.5 mg/L lower when washed with sector nozzle than the circular nozzle.

A Study on the Dynamic Characteristics of Free-Friction Stroke Damper by Finite Element Method (유한요소법을 이용한 Free-Friction Stroke 댐퍼의 동특성 해석)

  • Ku, Hi-Chun;Lee, Jae-Wook;Yoo, Wan-Suk
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.33 no.12
    • /
    • pp.1417-1426
    • /
    • 2009
  • Various types of damper are usually applied to reduce noise and vibration for mechanical systems. Especially, for washing machines, the free-friction stroke damper is installed. The behavior of the free-friction stroke damper has nonlinear characteristics such as hysteresis and viscoelastic properties because of its foam material. First of all, the dynamic experiments were carried out by using a MTS machine to find characteristics of the free-friction stroke damper. And the simulation model of the free-friction stroke damper and characteristics of a foam material were evaluated by using optimization technique. To make a good simulation model which can show the dynamic characteristics, it is important to understand the working mechanism of the damper. The Finite Element Method (FEM) technique can help us instinctively understand the damping phenomenon under operating conditions, because we can observe the condition of damper at every step in the simulation by using it. Also, by changing factors, we can comprehend the variation of characteristics of damper. So, in this paper, a study on the dynamic characteristics of free-friction stroke damper by FEM is focused on. Finally, the possibility which physical experiments can be replaced into simulations is shown.

Life-cycle Cost Analysis of Using Rainwater Harvesting Systems in Hong Kong Residential Buildings (홍콩 주거건물에서 우수활용시스템의 생애주기비용분석)

  • Gao, Xing;Kim, Youngchul;Lee, Hyun Woo
    • Journal of the Korean housing association
    • /
    • v.25 no.3
    • /
    • pp.53-62
    • /
    • 2014
  • This paper investigates whether the use of Rainwater Harvesting Systems (RWHSs) to provide water for washing machines in Hong Kong residential buildings would be financially attractive. In such systems, rainwater is accumulated and reused for doing laundry, garden irrigation, flushing toilets, and even drinking. Thus, the analysis of RWHSs' financial feasibility is essential for construction projects. RainCycle is used to validate financial feasibility, considering particular circumstances and data relevant to the Hong Kong context. A range of different scenarios by adjusting three factors are evaluated: catchment area, water demand, and discount rate. It is suggested that $2,000m^2$ would be a suitable catchment area in a typical Hong Kong residential building and it is demonstrated how water demand and discount rate influence the financial performance of RWHSs. In particular, the financial performance of RWHSs is sensitive to discount rates. The results suggest that the RWH system would be worthwhile for buildings with a lower number of floors, but would barely achieve financial validation in Hong Kong's super high-rise residential buildings.