• Title/Summary/Keyword: wall following

Search Result 671, Processing Time 0.028 seconds

Efficiency Analysis for RFID-based Curtain Wall of unit Type Construction (RFID 기술 적용에 따른 유닛타입 커튼월 공사의 효율성 분석)

  • Kang, Hyun-Koo;Ha, Young-Seo;Lim, Chul-Woo;Kim, Chang-Duk;Yu, Jung-Ho
    • Korean Journal of Construction Engineering and Management
    • /
    • v.9 no.3
    • /
    • pp.206-213
    • /
    • 2008
  • Due to the following reasons, the management of curtain wall parts and material is very Important. Firstly, curtain wall work is one of the main works in High-rise building construction for it takes about $10{\sim}15%$ of the total construction cost. Secondly, the whole process of curtain wall work including manu acture, delivery, storage, installation and maintenance is very complicated and sometimes more than 30 companies involve in the process. Thus there are many control points for curtain wall units. Thirdly, there are not enough space on site for material storage and this situation is more serious for sites in urban area. The purpose of this research is to validate an information systems using RFID technology that is developed to manage the curtain wall units following the process of curtain wall work. For the validation, the cycle times of curtain wall work before and a ter the system was used. The results show that using the systems shorten the cycle time of the curtain wall work. Thus it is concluded that the system can increase the efficiency of managing curtain wall work.

Thermal Performance Evaluation Monitoring Study of Transparent Insulation Wall System (투명단열 축열벽 시스템의 열성능 평가 실험 연구)

  • Kim, B.S.;Yoon, J.H.;Yoon, Y.J.;Baek, N.C.;Lee, J.S.
    • Journal of the Korean Solar Energy Society
    • /
    • v.23 no.1
    • /
    • pp.1-8
    • /
    • 2003
  • Various efforts to combine new high-tech materials with solar system have been progressed nowadays in order to improve the performance of the existing passive solar system. TIM(Transparent Insulation Material) replacing the conventional outer building envelope glazing as well as the wall is good example for this trend. TI integrated wall is a thermal mass wall with a special shaped TIM instead of using typical envelope materials The tested TIM type is a small(diameter 4mm and thickness 50mm) capillary tube of Okalux model and cement brick(density 1500kg/m3). The purpose of this study was to analyze the thermal performance through the actual measurements performed in a test cell. This study was carried out to justify the following issues. 1) the impact of Tl-wall over the temperature variations 2) the impact of mass wall surface absorptance over the transient thermal behavior and 3) the impact of thermal mass wall thickness over the temperature variations. Finally, as results indicated that the peak time of room temperature was shifted about one hour early when absorptance of thermal mass wall changed from 60% to 95% for the 190mm thickness thermal mass wall test case. the temperature difference of both surfaces of thermal mass wall surface showed about $23^{\circ}C$ during a day of March for the 380mm thickness thermal mass wall case. However, the thermal mass wall was over-heated by outside temperature and solar radiation in a day of May the temperature difference of both surfaces of thermal mass wall surface was indicated $10^{\circ}C$ and inside temperature was observed more than average 22C.

Experimental Study of Strength and Ductility on Masonry Wall Frame and Shear Wall Frame Subjected to Cyclic Lateral Loading (반복-횡력을 받는 조적벽 골조와 전단벽 골조의 내력 및 연성에 관한 실험적 연구)

  • Lee, Ho;Byeon, Sang-Min;Jung, Hwan-Mok;Lee, Taick-Oun
    • Journal of Korean Association for Spatial Structures
    • /
    • v.13 no.2
    • /
    • pp.83-91
    • /
    • 2013
  • The core aim of this dissertation is to empirically scrutinize a strength characteristic of beam-column frame subjected to the cyclic lateral load, a beam-column frame of un-reinforced masonry wall, and a shear wall frame. First and foremost, I embark upon making three prototypes vis-$\grave{a}$-vis this research. By conducting this process, I touch on an analysis of cyclic behavior and a damage characteristic of the beam-column frame, the beam-column frame of un-reinforced masonry wall, and the shear wall frame. What is more, through the previous procedure, the next part delves into the exact stress transfer path and the destructive mechanism to examine how much and how strong the beam-column frame of un-reinforced Masonry Wall does have a resistance capacity against earthquake in all the architecture constructed by the above-mentioned frame, as well as school buildings. In addition to the three prototypes, two more experimental models, a beam-column frame and shear wall frame, are used to compare with the beam-column frame of un-reinforced masonry wall. Lastly, the dissertation will suggest some solutions to improve the resistance capacity against earthquake regarding all constructions built with non bearing wall following having examining precisely all the analysis with regard to not only behavior properties and the damage mechanism of the beam-column frame and the beam-column frame of un-reinforced Masonry Wall but also the resistance capacity against earthquake of non bearing wall and school buildings.

Improvement and Evaluation of Seismic Resistant Performance of Reinforced Concrete Infilled Masonry Frame with Restraining Factor of Frame (철근콘크리트 프레임면내 조적벽체의 골조 구속에 따른 내진성능 평가 및 개선)

  • Shin, Jong-Hack;Ha, Gee-Joo;Lee, Hee-Jong
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.5 no.3
    • /
    • pp.131-139
    • /
    • 2001
  • Experimental programs were accomplished to improve and evaluate the structural performance of RC frame structures with masonry infilled wall, such as the hysteretic behavior, the maximum horizontal strength, crack propagation, and ductility etc. Test variables are restraining factors of frame, with or without masonry infilled wall, and masonry method. Six reinforced concrete rigid frame and masonry infilled wall were tested and constructed in one-third scale size under vertical and cyclic loads simultaneously. Based on the test results, the following conclusions can be made. For masonry infilled wall with restraining factors of frame(IFWB-1~3), cumulated energy dissipation capacities were increased by 1.35~1.60 times in comparision with that of masonry infilled wall(IFB-1) at final stage of testing. For masonry infilled wall with restraining factors of frame, maximum horizontal capacities were increased by 1.91~2.24 times in comparision with that of rigid frame.

  • PDF

A 4-axis NC Lettering System for the Side-wall of the Automobile Tire (타이어 사이드판의 문자 가공을 위한 4축 가공 시스템)

  • Lee, Cheol-Soo;Park, Gwang-Ryeol
    • IE interfaces
    • /
    • v.11 no.2
    • /
    • pp.65-78
    • /
    • 1998
  • The letters of the automobile tire are usually engraved on the side-wall. The shape of the side-wall is a sculptured surface generated by the rotational sweeping of a profile curve. The letters laid on the side-wall are usually designed by a 2-dimensional CAD. It is impossible to machine the letters on the surface accurately by 3-axis NC machining, because the axis of cutter should be tilted to align with the normal vector of the surface. In this case. the degree of freedom for the machine is at least four. This paper describes an idea for tool path generation of a 4-axis machine by using the 2-dimensional CAD data of the letters and the surface of the side-wall. This study includes the following procedures; (1) measuring the profile of the side-wall surface and curve-fitting of the measured points. (2) the 'non-parallel projection' of the letters on the side-wall, and (3) an inverse kinematics of the 4-axis lettering machine. Procedures in this paper are programmed in C-language on Windows95 environment. With a PC based CNC controller and a 4-axis lettering machine. these are tested sucessfully for the practical use.

  • PDF

Comparison of structural foam sheathing and oriented strand board panels of shear walls under lateral load

  • Shadravan, Shideh;Ramseyer, Chris C.;Floyd, Royce W.
    • Advances in Computational Design
    • /
    • v.4 no.3
    • /
    • pp.251-272
    • /
    • 2019
  • This study performed lateral load testing on seventeen wood wall frames in two sections. Section one included eight tests studying structural foam sheathing of shear walls subjected to monotonic loads following the ASTM E564 test method. In this section, the wood frame was sheathed with four different types of structural foam sheathing on one side and gypsum wallboard (GWB) on the opposite side of the wall frame, with Simpson HDQ8 hold down anchors at the terminal studs. Section two included nine tests studying wall constructed with oriented strand board (OSB) only on one side of the wall frame subjected to gradually applied monotonic loads. Three of the OSB walls were tied to the baseplate with Simpson LSTA 9 tie on each stud. From the test results for Section one; the monotonic tests showed an 11 to 27 percent reduction in capacity from the published design values and for Section two; doubling baseplates, reducing anchor bolt spacing, using bearing plate washers and LSTA 9 ties effectively improved the OSB wall capacity. In comparison of sections one and two, it is expected the walls with structural foam sheathing without hold downs and GWB have a lower wall capacity as hold down and GWB improved the capacity.

Blunt Transection of the Entire Anterolateral Abdominal Wall Musculature Following Seatbelt-Related Injury

  • Kim, Hohyun;Kim, Jae Hun;Kim, Gil Hwan;Sun, Hyun-Woo;Park, Chan Ik;Park, Sung Jin;Lee, Chan Kyu;Kim, Suk
    • Journal of Trauma and Injury
    • /
    • v.33 no.2
    • /
    • pp.128-133
    • /
    • 2020
  • Traumatic abdominal wall hernias (TAWHs) are uncommon and the incidence of this, which is rarely encountered in clinical practice, has been estimated at 1%. Furthermore, blunt transection of the entire abdominal wall musculature caused by seatbelt is a very rare complication. We report a case of adult with a complete disruption of the entire anterolateral abdominal wall muscle following the seatbelt injury. A 32-year-old male was wearing a seat belt in a high speed motor vehicle collision. Abdominal computed tomography (CT) scan revealed the complete disruption of bilateral abdominal wall musculatures including TAWH without visceral injury. However, injuries of small bowel and sigmoid colon were observed in the intra-operative field. The patient underwent the repair by primary closure of the defect with absorbable monofilament sutures. This case suggests that especially in TAWH patients, even if a CT scan is normal, clinicians should keep the possibility of bowel injury in mind, and choose a treatment based on the clinical findings.

Seismic Reliability Assessment of Mid- and High-rise Post-tensioned CLT Shear Wall Structures

  • Sun, Xiaofeng;Li, Zheng;He, Minjuan
    • International Journal of High-Rise Buildings
    • /
    • v.9 no.2
    • /
    • pp.175-185
    • /
    • 2020
  • Currently, few studies have been conducted to comprehend the seismic reliability of post-tensioned (PT) CLT shear wall structures, due to the complexity of this kind of structural system as well as due to lack of a reliable structural model. In this paper, a set of 4-, 8-, 12-, and 16-storey benchmark PT CLT shear wall structures (PT-CLTstrs) were designed using the direct displacement-based design method, and their calibrated structural models were developed. The seismic reliability of each PT-CLTstr was assessed based on the fragility analysis and based on the response surface method (RSM), respectively. The fragility-based reliability index and the RSM-based reliability index were then compared, for each PT-CLTstr and for each seismic hazard level. Results show that the RSM-based reliabilities are slightly less than the fragility-based reliabilities. Overall, both the RSM and the fragility-based reliability method can be used as efficient approaches for assessing the seismic reliabilities of the PT-CLTstrs. For these studied mid- and high-rise benchmark PT-CLTstrs, following their fragility-based reliabilities, the 8-storey PT-CLTstr is subjected to the least seismic vulnerability; while, following their RSM-based reliabilities, the 4-storey PT-CLTstr is subjected to the least seismic vulnerability

Analysis of the Chest Wall Reconstruction Methods after Malignant Tumor Resection

  • Gang Yeon Jo;Sae Hwi Ki
    • Archives of Plastic Surgery
    • /
    • v.50 no.1
    • /
    • pp.10-16
    • /
    • 2023
  • Background The chest wall defects can be caused by various reasons. In the case of malignant tumor resection of the chest wall, it is essential to reconstruct the chest wall to cover the vital tissue and restore the pulmonary function with prevention of paradoxical motion. With our experience, we analyzed and evaluated the results and complications of the chest wall reconstructions followed by malignant tumor resection. Methods From 2013 to 2022, we reviewed a medical record of patients who received chest reconstruction due to chest wall malignant tumor resection. The following data were retrieved: patients' demographic data, tumor type, type of operation, method of chest wall reconstruction of the soft and skeletal tissue and complications. Results There were seven males and six female patients. The causes of reconstruction were 12 primary tumors and one metastatic carcinoma. The pathological types were seven sarcomas, three invasive breast carcinoma, and three squamous cell carcinomas. The skeletal reconstruction was performed in six patients. The series of the flap were eight pedicled latissimus dorsi (LD) myocutaneous flaps, two pectoralis major myocutaneous flap, two vertical rectus abdominis myocutaneous free flap, and one LD free flap. Among all the cases, only one staged reconstruction and successful reconstruction without flail chest. Most of the complications were atelectasis. Conclusion In the case of accompanying multiple ribs and sternal defect, skeletal reconstruction would need skeletal reconstruction to prevent paradoxical chest wall motion. The flap for soft tissue defect be selected according to defect size and location of chest wall. With our experience, we recommend the reconstruction algorithm for chest wall defect due to malignant tumor resection.

Electron Microscopic Observations of the Effects of Thiocarbanilides(L-1) on Dermatophytes (표재성(表在性) 진균(眞菌)의 Thiocarbanilide(L-1) 처리효과에 대(對)한 전자현미경적(電子顯微鏡的) 관찰(觀察))

  • Koh, Choon-Myung;Kim, Tai-Won;Lew, Joon
    • The Journal of the Korean Society for Microbiology
    • /
    • v.5 no.1
    • /
    • pp.9-18
    • /
    • 1970
  • The present study is of ultra-fine structures of Trichophyton rubrum, Trichophyton mentagrophytes, Microsporum canis and Epidermophyton floccosum by means of electron microscopy and reveals the following. 1. In contrast to the bacteria, the normal fungus contains nuclear membrane, mitochondria, endoplasmic reticulun, distinct cell wall and cell membrane and secretory granules as observed in the higher plants and animals. 2. Thickening of the cell wall, inapparent cell wall, inapparent cell membrane with the appearance of electron thin area(ETA) and increase of inclusions were observed in the L-1 treated groups. 3. Thickening of cell wall and increase of ETA were more apparent in the Epidermophyton floccosum than the other groups. 4. Increase of electron thin area was thought to be associated with autolysis.

  • PDF