• Title/Summary/Keyword: wall confinement effect

Search Result 33, Processing Time 0.022 seconds

Experimental behavior of circular flyash-concrete-filled steel tubular stub columns

  • Zhang, Yang;Fu, Guang-Yuan;Yu, Chen-Jiang;Chen, Bing;Zhao, She-Xu;Li, Si-Ping
    • Steel and Composite Structures
    • /
    • v.22 no.4
    • /
    • pp.821-835
    • /
    • 2016
  • The paper presents an experimental study of the structural behavior of circular flyash-concrete-filled steel tubular stub columns under axial compressive loads. In this study, 90% and 100% by weight of the cement in the concrete core was replaced with flyash. Twenty-seven specimens were tested to study the influence of flyash content, wall thickness of the steel tube, and curing age on the ultimate capacity and confinement effect. The experimental results were compared with the design values calculated using AISC-LRFD (1999), ACI (1999), AIJ (1997) and Eurocode 4 (1994). From the experimental study, it was determined that the confinement effect of circular steel tubes filled with high content flyash concrete was better than that of specimens filled with ordinary Portland cement concrete. The 5.88-mm-thick steel tube filled with 100% flyash concrete was equivalent in strength to a steel tube filled with C30 concrete at 28 days.

Effect of tube area on the behavior of concrete filled tubular columns

  • Gupta, P.K.;Verma, V.K.;Khaudhair, Ziyad A.;Singh, Heaven
    • Computers and Concrete
    • /
    • v.15 no.2
    • /
    • pp.141-166
    • /
    • 2015
  • In the present study, a Finite Element Model has been developed and used to study the effect of diameter to wall thickness ratio (D/t) of steel tube filled with concrete under axial loading on its behavior and load carrying capacity. The model is verified by comparing its findings with available experimental results. Influence of thickness and area of steel tube on strength, ductility, confinement and failure mode shapes has been studied. Strength enhancement factors, load factor, confinement contribution, percentage of steel and ductility index are defined and introduced for the assessment. A parametric study by varying length and thickness of tube has been carried out. Diameter of tube kept constant and equals to 140 mm while thickness has been varied between 1 mm and 6 mm. Equations were developed to find out the ultimate load and confined concrete strength of concrete. Variation of lateral confining pressure along the length of concrete cylinder was obtained and found that it varies along the length. The increase in length of tubes has a minimal effect on strength of tube but it affects the failure mode shapes. The findings indicate that optimum use of materials can be achieved by deciding the thickness of steel tube. A better ductility index can be obtained with the use of higher thickness of tube.

Effect of axial loading conditions and confinement type on concrete-steel composite behavior

  • Nematzadeh, Mahdi;Fazli, Saeed
    • Computers and Concrete
    • /
    • v.25 no.2
    • /
    • pp.95-109
    • /
    • 2020
  • This paper aims to analytically study the effect of loading conditions and confinement type on the mechanical properties of the concrete-steel composite columns under axial compressive loading. The axial loading is applied to the composite columns in the two ways; only on the concrete core, and on the concrete core and steel tube simultaneously, which are called steel tube-confined concrete (STCC) and concrete-filled steel tube (CFST) columns, respectively. In addition, the confinement is investigated in the three types of passive, short-term active and long-term active confinement. Nonlinear finite element 3D models for analyzing these columns are developed using the ABAQUS program, and then these models are verified with respect to the recent experimental results reported by the authors on the STCC and CFST columns experiencing active and passive confinements. Axial and lateral stress-strain curves as well as the failure mode for qualitative verification, and compressive strength for quantitative verification are considered. It is found that there is a good consistency between the finite element analysis results and the experimental ones. In addition, a parametric study is performed to evaluate the effect of axial loading type, prestressing ratio, concrete compressive strength and steel tube diameter-to-wall thickness ratio on the compressive behavior of the composite columns. Finally, the compressive strength results of CFST specimens obtained via the finite element analysis are compared with the values specified by the international codes and standards including EC4, CSA, ACI-318, and AISC, with the results showing that ACI-318 and AISC underestimate the compressive strength of the composite columns, while EC4 and CSA codes present overestimated values.

Wall charge effects on structural properties of a coarse-grained FENE polyelectrolyte confined in slit nanochannels by Brownian dynamics simulation

  • Jeon, Jong-Gu;Chun, Myung-Suk
    • Korea-Australia Rheology Journal
    • /
    • v.19 no.2
    • /
    • pp.51-59
    • /
    • 2007
  • A polyelectrolyte chain confined in a slit nanochannel exhibits a structural transition from the one in free space. In this paper, the effect of the long-range electrostatic interactions between the xanthan polyelectrolyte and the slit wall on the confined xanthan conformation is investigated via the Brownian dynamics simulation. A neutral and two negatively charged surfaces of polydimethylsiloxane (PDMS) and glass are combined to make four kinds of slit channels with different charge characteristics: i) neutral-neutral, ii) glass-glass, iii) neutral-PDMS and iv) neutral-glass walls. Their walls are characterized by uniform surface charge densities determined from experimental data of zeta potential. Both the nonmonotonic chain size variation and the loss of long-range bond vector correlation, previously observed under confinement in the PDMS-PDMS slit, are also found in the neutral slit, demonstrating the nonelectrostatic origin of such crossover behaviors. As expected, the effect of wall charges is negligible at sufficiently high medium ionic strength of 100mM but it becomes significant in the opposite limit of 0.01mM. In the latter case, the high charge density of glass walls strengthens the effective confinement of a negatively charged polyelectrolyte and produces a xanthan structure comparable to that confined in a much narrower neutral slit. The obtained structural data suggest the possibility of controlling the structure of confined polyelectrolytes by the modification of surface charge characteristics of micro/nanofluidic devices in combination with the adjustment of the medium ionic strength.

Ducti1ity, Evaluation of Circular Reinforced Concrete Piers with an Internal Steel Tube (강관 내무보강 중공교각의 연성도 평가)

  • 강영종;최진유;김도연;한택희
    • Proceedings of the KSR Conference
    • /
    • 2001.05a
    • /
    • pp.241-248
    • /
    • 2001
  • The ductility of circular hollow reinforced concrete columns with one layer of longitudinal and spiral reinforcement placed near the outside face of the section and the steel tube placed on the inside face of the section is investigated. Such hollow sections are confined through the wall thickness since the steel tube is placed. The results of analytical moment-curvature analyses for such hollow sections are compared with those for the circular section with the sane diameter. In this study, moment-curvature analyses are conducted with Mandel's confined concrete stress-strain relationship in which the effect of confinement is to increase the compression strength and ultimate strain of concrete. The moment-curvature analyses confirmed that the ductility is primarily influenced on the ultimate strain. The variables influenced on the ultimate strain is the ratio and yield strength of confining reinforcement and the compression strength for confined concrete. From this ultimate strain - the transverse reinforcement ratio relationship, the transverse reinforcement ratio for circular hollow reinforced columns with confinement is proposed. The proposed transverse reinforcement ratio is confirmed by experimental results.

  • PDF

Evaluation of interfacial shear stress in active steel tube-confined concrete columns

  • Nematzadeh, Mahdi;Ghadami, Jaber
    • Computers and Concrete
    • /
    • v.20 no.4
    • /
    • pp.469-481
    • /
    • 2017
  • This paper aims to analytically investigate the effect of shear stress at the concrete-steel interface on the mechanical behavior of the circular steel tube-confined concrete (STCC) stub columns with active and passive confinement subjected to axial compression. Nonlinear 3D finite element models divided into the four groups, i.e. circumferential-grooved, talc-coated, lubricated, and normal groups, with active and passive confinement were developed. An innovative method was used to simulate the actively-confined specimens, and then, the results of the finite element models were compared with those of the experiments previously conducted by the authors. It was revealed that both the predicted peak compressive strength and stress-strain curves have good agreement with the corresponding values measured for the confined columns. Then, the mechanical properties of the active and passive specimens such as the concrete-steel interaction, longitudinal and hoop stresses of the steel tube, confining pressure applied to the concrete core, and compressive stress-strain curves were analyzed. Furthermore, a parametric study was performed to explore the effects of the concrete compressive strength, steel tube diameter-to-wall thickness ratio, and prestressing level on the compressive behavior of the STCC columns. The results indicate that reducing or removing the interfacial shear stress in the active and passive specimens leads to an increase in the hoop stress and confining pressure, while the longitudinal stress along the steel tube height experiences a decrease. Moreover, prestressing via the presented method is capable of improving the compressive behavior of STCC columns.

An Experimental Study on the High-Strength Concrete Shear Wall using Rectangular Steel Tubes (각형강관을 사용한 고강도 콘크리트 전단벽체에 대한 실험적 연구)

  • 최기봉;조순호;김명준;오종환
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 1997.04a
    • /
    • pp.460-467
    • /
    • 1997
  • Compared to normal-strength concrete, high-strength concrete has the lower lateral expansion capacity caused by the higher elastic modulus and the lower internal crack characteristic. Therefore, the effect of the lateral confining action of hoops appears slowly and also in inefficient Nevertheless. it has been reported that the strength and deformation capacity of high-strength concrete is improved by well-distributed hoops. Due to that argument, this investigation has been compared and analyzed by the experimental works on the deformation capacity and the confinement mechanism of high-strength concrete shear wall of the high-rise building reinforced by rectangular steel tubes and rectangular hoops at both edges of the shear wall.

  • PDF

Numerical Study of Detonation Wave Structure and Dynamics in a Circular Tube (원형관 내 데토네이션 파 구조 및 동적 특성 수치 연구)

  • Cho, Deok-Rae;Kim, Jong-Kwan;Jang, Keun-Jin;Choi, Jeong-Yeol
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2012.05a
    • /
    • pp.278-281
    • /
    • 2012
  • Numerical studies were performed to investigate the three-dimensional front structure and dynamics features of detonation wave propagating in a circular tube such as Pulse Detonation Engine (PDE). By carrying out a series of parametric study using one step irreversible Arrhenius kinetics model, mechanisms of the three-dimensional front structure were investigated for two-, three-, four and six-cell mode detonations. A comparison with two-dimensional results, the effects of slapping transverse waves in radial direction were confirmed. In the all muti-cell modes, the detonation front structures and smoked-records on the wall are formed by the propagation of transverse waves along the wall in clockwise and counter-clockwise while the slapping move in radial direction. And the strength of reflected waves on the curved wall is changed by the multi-dimensional confinement effect.

  • PDF

Deformation Analysis of Geosynthetic Reinforced Retaining Wall by Using Temperature Dependent Confined Tension Test Results (온도제어 구속인장시험에 의한 토목섬유 보강토옹벽의 변위해석)

  • 김홍택;방윤경;조용권
    • Journal of the Korean Geotechnical Society
    • /
    • v.19 no.2
    • /
    • pp.97-106
    • /
    • 2003
  • In this study, the effect of temperature and soil confining stress on geosyntheic stress-strain properties was quantified by performing the temperature dependent confined tension tests for four types of geosynthetic including woven geotextile, composite, geomembrane and geogrid specimen. Temperature instrumentation on the GRS-retaining wall constructed in Jaechon-shi area was also performed to examine the a seasonal temperature variation of geosynthetic reinforcements in the backfill. Based on the test results, a comparison was made between unconfined and confined moduli far each temperature to quantify the soil confinement and temperature effect on stress-strain properties. And it was also proposed that the simple expressions for the secant moduli of geosynthetics as a function of temperature and confining stress on geosynthetics. As a result of the FDM analysis of GRS-retaining wall, the method of considering the effect of temperature and confining stress on geosynthetic reinforcements when performing the FDM analysis of GRS-retaining wall was proposed.

An Experimental Study on Heat Transfer and Flow Characteristics of a Circular Impinging Jet on a Flat Plate : Effects of Nozzle Wall Thickness and Nozzle Exit Pressure (원형 제트 충돌 열전달과 유동 특성에 관한 실험적 연구 : 노즐 벽 두께와 노즐 출구 압력의 영향)

  • Yoon, Sangheon;Yang, Geunyoung;Sohn, Dong Kee;Choi, Mansoo
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.23 no.10
    • /
    • pp.1285-1295
    • /
    • 1999
  • An experimental study on heat transfer and flow characteristics of a circular impinging jet on a flat plate has been carried out. Of particular interests are the effects of nozzle wall thickness and nozzle exit pressure. Experimental apparatus has been designed to view heating plate coated by TLC from the opposite side of the nozzle in order to measure heat transfer rates for cases of very small nozzle to plate spacings. A visualization study of jet flows has also been performed. As the nozzle wall thickness increases at small nozzle to plate spacings, the effect of mixing is inhibited due to the confinement caused by the finite nozzle wall, consequently, heat transfer rates have been decreased. At small nozzle to plate spacings, heat transfer rates and nozzle exit pressures are increased together, therefore, enhancement of heat transfer at small nozzle to plate spacings should be considered in conjunction with the need of more fan power to generate the same Reynolds numbers.