• 제목/요약/키워드: vote distribution

검색결과 31건 처리시간 0.019초

자기 조직화 지도를 이용한 다중 평면영역 검출 (Multiple Plane Area Detection Using Self Organizing Map)

  • 김정현;등죽;강동중
    • 제어로봇시스템학회논문지
    • /
    • 제17권1호
    • /
    • pp.22-30
    • /
    • 2011
  • Plane detection is very important information for mission-critical of robot in 3D environment. A representative method of plane detection is Hough-transformation. Hough-transformation is robust to noise and makes the accurate plane detection possible. But it demands excessive memory and takes too much processing time. Iterative randomized Hough-transformation has been proposed to overcome these shortcomings. This method doesn't vote all data. It votes only one value of the randomly selected data into the Hough parameter space. This value calculated the value of the parameter of the shape that we want to extract. In Hough parameters space, it is possible to detect accurate plane through detection of repetitive maximum value. A common problem in these methods is that it requires too much computational cost and large number of memory space to find the distribution of mixed multiple planes in parameter space. In this paper, we detect multiple planes only via data sampling using Self Organizing Map method. It does not use conventional methods that include transforming to Hough parameter space, voting and repetitive plane extraction. And it improves the reliability of plane detection through division area searching and planarity evaluation. The proposed method is more accurate and faster than the conventional methods which is demonstrated the experiments in various conditions.

사무실 공간의 냉방시 천장 및 바닥 급기 공조 방식에 따른 열환경 평가 실험 (Experimental Analysis of Thermal Comfort of an Office Space for Ceiling and Floor Supply Air Conditioning Systems)

  • 조용;권혁승;김성현;김영일
    • 설비공학논문집
    • /
    • 제12권9호
    • /
    • pp.810-816
    • /
    • 2000
  • Thermal comfort plays an important role in modern office buildings. Four major factors affecting thermal comfort are air temperature, velocity, humidity and radiation temperature. Distribution of these thermal factors in indoor space depends largely on the air flow which is related to the method of supplying and extracting air. In this study, an experimental analysis on indoor thermal comfort is conducted to study the difference between a ceiling supply cooling system and a floor supply one. The two cooling systems are applied to an office space during summer season and the distributions of temperature, velocity, radiation temperature and PMV are measured. Results show that the floor supply cooling system is superior in terms of thermal comfort and energy saving. Studies need to be done, however, to reduce the vertical temperature difference of a floor supply air conditioning system.

  • PDF

A study on village economic cooperative in the city of China

  • Chen, Lifeng;Jin, Shanyue
    • International Journal of Advanced Culture Technology
    • /
    • 제8권3호
    • /
    • pp.1-9
    • /
    • 2020
  • According to the 2012 social blue book released by the Chinese Academy of Social Sciences, China's urban population reached 50% in 2011. With the migration from marriage and new household registration, many urban collective assets have been formed in cities. Due to the unclear property rights and the emptiness of the main body, the distribution of collective assets mostly depends on the village cadres. The central government is preparing relevant laws and regulations to fill this legal gap, while the scheme of restructuring is decided by the villagers' vote, the local government coordinate the land acquisition and management. With the process of urbanization, a large number of second-generation of demolition studied abroad, which has attracted worldwide attention. In addition to the huge amount of compensation, due to the continuous rising of the land price, the value of the collective property and enterprises on the land also keep rising, the management agency of these assets is named village economic cooperative. This paper seeks to analyze the current status and future direction of these wealthy organizations, propose solutions to some existing problems.

교실 천장형 Unit의 위치에 따른 온열환경 평가 연구 (A Study on the Evaluation of Thermal Environment according to the Location of Ceiling Type Unit in Classroom)

  • 조성우;최정민;손영환
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2005년도 동계학술발표대회 논문집
    • /
    • pp.135-140
    • /
    • 2005
  • Installation of ceiling type unit is achieved by one of efforts for agreeable classroom environment embodiment along with economic growth. But research about changing the position of ceiling type unit is lacking in present. Therefore, this thesis is to study the thermal environment of 5 different position cases of ceiling type, namely Case A, B, C, D, E. Here, Case C is the case that has the position of ceiling type center of the classroom and the other 4 alternatives are 0.7 m away from the Case C according to x and z axis. In this thesis temperature distributions, air current distribution, heat amenities such as PMV of occupants are analyzed as the environmental factors. Through these factors, Case C and Case D are the better position alternatives than the alternatives of Case A, Case B and Case E because the latter cases the air current reaches directly to indoor occupants so that occupants feel chilly. This thesis has a conclusion under the condition of only one inlet air temperature and seat arrangement. But afterwards more inlet air condition and seat arrangement must be considered.

  • PDF

겨울철 가습 및 환기에 따른 교실내 쾌적환경 분석 (Analysis of Comfortable Environment in the Classroom with Humidification and Ventilation in Winter)

  • 성내리;정성일;이재근;박종훈
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2008년도 하계학술발표대회 논문집
    • /
    • pp.1213-1219
    • /
    • 2008
  • This experimental study was to analyze thermal comfort and indoor air quality(IAQ) with ventilation and humidification in the classroom when system air conditioner was operated. The thermal comfort was estimated by the PMV index and the concentration of $CO_2$ and total suspended particle(TSP) were measured and compared with ventilation and humidification. As a result, the class room temperature distribution was $2{\sim}5^{\circ}C$ low during operating ventilation system and humidification. At 60% RH, PMV values of measuring points were ranged from +0.5 to -0.5 indicating optimal the range of thermal comfort. The average concentration of $CO_2$ gas and TSP were reduced 645 ppm, 0.17 mg/$m^3$ respectively, during operating the ventilation system. From the results, to maintain comfortable environment in the heated classroom, the ventilation and humidification were needed in winter season.

  • PDF

기류유인팬을 이용한 새 국립중앙박물관 로튠다에서의 열환경 평가 (Evaluation on Thermal Environment Installed Ventilating Fans in the Rotunda at New National Museum of Korea)

  • 이승철
    • 설비공학논문집
    • /
    • 제16권3호
    • /
    • pp.303-309
    • /
    • 2004
  • In order to improve thermal comfort in the Rotunda, which is high and wide visiting space of the new national museum of Korea, eight ventilating fans were installed near the ceiling of Rotunda. It has been analyzed thermal comfort of Rotunda with/without ventilating fans by numerical simulation. To evaluate thermal comfort of the Rotunda, well-known indices, PMV and PPD were introduced. The results of present investigation show that temperature distribution of the case with fans is closer to target temperature than the case with-out fans at the breathing zone. In the case without fans, thermal stratification with 16$^{\circ}C$ of temperature difference occurs along the height of the Rotunda which makes the thermal environment worse and the PPD values reach up to 50% in the 6th floor connection passage. In the case with fans, however, the vertical temperature difference were reduced to 9$^{\circ}C$ and the PPD values were lower below 20%. Consequently, the ventilating fans adopted on this study are effectively used for improving the thermal comfort in large space structure with thermal stratification.

실내수영장의 열, 기류 및 습도환경에 관한 연구 (A Study of Thermal, Air-flow and Humidity Conditions in an Indoor Swimming Pool)

  • 강석윤;이태구;문종선;이재헌
    • 설비공학논문집
    • /
    • 제15권8호
    • /
    • pp.683-689
    • /
    • 2003
  • The thermal comfort of an indoor swimming pool is different from that of general indoor space because of the characteristics of large space and the wear conditions of swimmers. Dew condensation by humid air not only makes mold on the floor, wall and roof but also decreases the durability of buildings by penetrating into their structures. In this study, the characteristics of the flow field, the temperature field and the humidity distribution in an indoor swimming pool have been examined by the numerical method to estimate the level of thermal comfort and the generation rate of dew condensation. The results showed that the dew condensation regions were spread widely at the eastern parts of the swimming pool due to the insufficient air flow rate with low velocity and temperature. To prevent the generation of dew condensation in a region, a sufficient warm air flow rate should be supplied to make an air mixing. The values of PMV at horizontal plane of 1.5 m height have the range of -1.0∼1.2, which means the suitable level for swimmers.

차량 내부 탑승자의 쾌적성 평가를 위한 초기 냉방운전 성능에 대한 수치해석적 연구 (Numerical Analysis on the Initial Cool-down Performance Inside an Automobile for the Evaluation of Passenger's Thermal Comfort)

  • 김윤기;양장식;백제현;김경천;지호성
    • 한국자동차공학회논문집
    • /
    • 제18권5호
    • /
    • pp.115-123
    • /
    • 2010
  • Cool-down performance after soaking is important because it affects passenger's thermal comfort. The cooling capacity of HVAC system determines initial cool down performance in most cases, the performance is also affected by location, and shape of panel vent, indoor seat arrangement. Therefore, optimal indoor designs are required in developing a new car. In this paper, initial cool down performance is predicted by CFD(computational fluid dynamics) analysis. Experimental time-averaging temperature data are used as inlet boundary condition. For more reliable analysis, real vehicle model and human FE model are used in grid generation procedure. Thermal and aerodynamic characteristics on re-circulation cool vent mode are investigated using CFX 12.0. Thermal comfort represented by PMV(predicted mean vote) is evaluated using acquired numerical data. Temperature and velocity fields show that flow in passenger's compartment after soaking is considerably unstable at the view point of thermodynamics. Volume-averaged temperature is decreased exponentially during overall cool down process. However, temperature monitored at different 16 spots in CFX-Solver shows local variation in head, chest, knee, foot. The cooling speed at the head and chest nearby panel vent are relatively faster than at the knee and foot. Horizontal temperature contour shows asymmetric distribution because of the location of exhaust vent. By evaluating the passenger's thermal comfort, slowest cooling region is found at the driver's seat.

소매점 볼런터리 체인 활성화의 선행요인과 결과 (Antecedents and Consequences of Cooperation in Retail Voluntary Chain)

  • 이호택
    • 유통과학연구
    • /
    • 제14권6호
    • /
    • pp.65-73
    • /
    • 2016
  • Purpose - Recently, the management conditions of small independent retailers are getting worse everyday as large-scale marts and franchised convenience stores are increasing. The objective of this research is to find out the antecedents and consequences of cooperation in voluntary chain in order to enhance small independent retailer's competitiveness. Voluntary chains, also called affiliation or symbol groups, or allied group represent a high market shared in some European countries like Italy, France, and Germany. Nevertheless, there are still limitations in this research from academic fields. Drawing from network theory, the author investigates the relationship between antecedent factors in voluntary chain cooperation, such as participation benefits, justice of compensation, and autonomy in voluntary chain, and relationship specific asset. The author also attempts to examine the relationship between the relationship specific asset and cooperation of voluntary chain member shop and cooperation and consequence factors of voluntary chain cooperation, such as efficiency, group cohesiveness, and long-term relationship. Research design, data, and methodology - The author presented conceptual framework integrating the major antecedents and consequences of voluntary chain cooperation. The data were collected from 174 independent small retailers who joined K-voluntary chain. K-voluntary chain consists of small independent retailers. In accordance with their status, each entrepreneur associated with the voluntary group can own one or more outlets and can be a part of the life and the decision-making process of the group. This participation is not based on company turnover or on the number of outlets, but based on a one member, one vote system. To verify the research model and test hypotheses, the author carefully investigated the reliability, content validity, convergent validity, and discriminant validity of the proposed model. The data were analyzed by using SPSS 18.0 and AMOS structural equation modeling program. Results - The results of this study are as follows. First, as antecedent variables, participation benefits and justice of compensation have positive effect on the relationship specific assets of voluntary chain members. Second, voluntary chain members' relationship specific asset also directly related to the level of its cooperation to chain headquarter. Third, cooperation of voluntary chain member shop facilitates efficiency, group cohesiveness, and long-term relationship. Unexpectedly, there are no effect autonomy in voluntary chain to relationship specific asset. Conclusions - This research shows several theoretical and practical implications to both marketing scholars and marketers. In terms of theoretical implications, this study applies to network theory and network theory variables to explain the antecedent and consequence factors of cooperation in voluntary chain. From the point of view from business management, most of all, this study shows the way how to reinforce competitiveness of voluntary chain. Specifically, it is necessary for voluntary chain headquarter to give higher level of participation benefit and justice of compensation to its members. Second, the results also indicate what the consequence factors of cooperation in voluntary chain. In other words, to increase the level of marketing efficiency, group cohesiveness, long-term orientation in retail voluntary chain, and chain headquarter need to facilitate participants' cooperation.

도시근린공원의 열환경 개선을 위한 열쾌적성 평가 (An Evaluation of Thermal Comfort on Urban Neighborhood Park for Improving Thermal Environment)

  • 임은나;이우성;최철현;송봉근;정성관
    • 한국지리정보학회지
    • /
    • 제16권4호
    • /
    • pp.153-170
    • /
    • 2013
  • 본 연구는 도시 근린공원의 열쾌적성을 평가하고 이에 따른 열환경 개선방안을 도출하고자 연구를 진행하였다. 먼저 공원의 주요 열환경 인자의 분포특성 및 공간 유형별 차이를 평가한 결과, 기온, 상대습도, 풍속의 경우 공간적으로 뚜렷한 차이를 보이지 않았다. 그러나 평균복사온도는 공간의 개방정도 및 포장재질에 따라 큰 차이를 나타내는 것으로 확인되었다. 추출된 열환경 인자를 토대로 공간 유형에 따른 열쾌적성을 평가한 결과, 광장의 PMV(Predicted Mean Vote, 예상온열감) 지수가 4.39로 가장 높게 나타났으며, 동선의 경우 2.58, 녹지 1.90 그리고 휴게공간은 0.42로 평가되었다. 이러한 열쾌적성을 결정하는 열환경 요인에 대한 중요도를 평가해보기 위하여 PMV 회귀모형을 구축한 결과, 평균복사온도(1.084), 풍속(-0.280), 기온(0.013), 상대습도(-0.009)의 순으로 PMV에 대한 상대적인 중요도가 높게 나타났다. 열환경적 측면에서 개선이 필요한 지역을 대상으로 시나리오 분석을 실시한 결과, 반사율, 색상, 포장재질의 물리적 특성 변화를 통해 인체가 체감하는 열쾌적성을 향상시킬 수 있으며, 실제 공원에 이를 적용하여 개선안을 마련할 수 있을 것으로 판단된다.