• Title/Summary/Keyword: volume rendering

Search Result 278, Processing Time 0.026 seconds

Development of Graphical Solution for Computer-Assisted Fault Diagnosis: Preliminary Study (컴퓨터 원용 결함진단을 위한 그래픽 솔루션 개발에 관한 연구)

  • Yoon, Han-Bean;Yun, Seung-Man;Han, Jong-Chul;Cho, Min-Kook;Lim, Chang-Hwy;Heo, Sung-Kyn;Shon, Cheol-Soon;Kim, Seong-Sik;Lee, Seok-Hee;Lee, Suk;Kim, Ho-Koung
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.29 no.1
    • /
    • pp.36-42
    • /
    • 2009
  • We have developed software for converting the volumetric voxel data obtained from X-ray computed tomography(CT) into computer-aided design(CAD) data. The developed software can used for non-destructive testing and evaluation, reverse engineering, and rapid prototyping, etc. The main algorithms employed in the software are image reconstruction, volume rendering, segmentation, and mesh data generation. The feasibility of the developed software is demonstrated with the CT data of human maxilla and mandible bones.

Verification of Dose Evaluation of Human Phantom using Geant4 Code (Geant4 코드를 사용한 인체팬텀 선량평가 검증)

  • Jang, Eun-Sung;Choi, Ji-Hoon
    • Journal of the Korean Society of Radiology
    • /
    • v.14 no.5
    • /
    • pp.529-535
    • /
    • 2020
  • Geant4 is compatible with the Windows operating system in C++ language use, enabling interface functions that link DICOM or software. It was simulated to address the basic structure of the simulation using Geant4/Gate code and to specifically verify the density composition and lung cancer process in the human phantom. It was visualized using the Gate Graphic System, i.e. openGL, Ray Tracer: Ray Tracing by Geant4 Tracing, and using Geant4/Gate code, lung cancer is modeled in the human phantom area in 3D, 4D to verify the simulation progress. Therefore, as a large number of new functions are added to the Gate Code, it is easy to implement accurate human structure and moving organs.

Development of 3D Modeling Technology of Human Vacancy for Bio-CAD (Bio-CAD를 위한 인체공동부의 3차원 모델링 기술 개발)

  • Kim, Ho-Chan;Bae, Yong-Hwan;Kwon, Ki-Su;Seo, Tae-Won;Lee, Seok-Hee
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.26 no.12
    • /
    • pp.138-145
    • /
    • 2009
  • Custom medical treatment is being widely adapted to lots of medical applications. A technology for 3D modeling is strongly required to fabricate medical implants for individual patient. Needs on true 3D CAD data of a patient is strongly required for tissue engineering and human body simulations. Medical imaging devices show human inner section and 3D volume rendering images of human organs. CT or MRI is one of the popular imaging devices for that use. However, those image data is not sufficient to use for medical fabrication or simulation. This paper mainly deals how to generate 3D geometry data from those medical images. A new image processing technology is introduced to reconstruct 3D geometry of a human body vacancy from the medical images. Then a surface geometry data is reconstructed by using Marching cube algorithm. Resulting CAD data is a custom 3D geometry data of human vacancy. This paper introduces a novel 3D reconstruction process and shows some typical examples with implemented software.

A Dual Modeling Method for a Real-Time Palpation Simulator

  • Kim, Sang-Youn;Park, Se-Kil;Park, Jin-Ah
    • Journal of Information Processing Systems
    • /
    • v.8 no.1
    • /
    • pp.55-66
    • /
    • 2012
  • This paper presents a dual modeling method that simulates the graphic and haptic behavior of a volumetric deformable object and conveys the behavior to a human operator. Although conventional modeling methods (a mass-spring model and a finite element method) are suitable for the real-time computation of an object's deformation, it is not easy to compute the haptic behavior of a volumetric deformable object with the conventional modeling method in real-time (within a 1kHz) due to a computational burden. Previously, we proposed a fast volume haptic rendering method based on the S-chain model that can compute the deformation of a volumetric non-rigid object and its haptic feedback in real-time. When the S-chain model represents the object, the haptic feeling is realistic, whereas the graphical results of the deformed shape look linear. In order to improve the graphic and haptic behavior at the same time, we propose a dual modeling framework in which a volumetric haptic model and a surface graphical model coexist. In order to inspect the graphic and haptic behavior of objects represented by the proposed dual model, experiments are conducted with volumetric objects consisting of about 20,000 nodes at a haptic update rate of 1000Hz and a graphic update rate of 30Hz. We also conduct human factor studies to show that the haptic and graphic behavior from our model is realistic. Our experiments verify that our model provides a realistic haptic and graphic feeling to users in real-time.

A Virtual Sculpting System using Haptic Interface (햅틱 인터페이스를 이용한 가상 조각 시스템)

  • Kim Laehyun;Park Sehyung
    • Journal of KIISE:Computer Systems and Theory
    • /
    • v.31 no.12
    • /
    • pp.682-691
    • /
    • 2004
  • We present a novel haptic sculpting system where the user intuitively adds to and carves out material from a volumetric model using new sculpting tools in the similar way to handling real clay Haptic rendering and model deformation are implemented based on volumetric implicit surface. We enhance previous volume-based haptic sculpting systems by presenting fast and stable force computation on 3D models to be deformed. In order to bridge the gap between fast haptic process (1 KHz) and much slower visual update frequency(~30Hz), the system generates intermediate implicit surfaces between two consecutive physical models being deformed. It performs collision detection and force computation on the intermediate surface in haptic process. The volumetric model being sculpted is visualized as a geometric model which is adaptively polygonized according to the surface complexity. We also introduce various visual effects for the real-time sculpting system including mesh-based solid texturing, painting, and embossing/engraving techniques.

Development of a High-Speed Endoscopic OCT System and Its Application to Three-Dimensional Intravascular Imaging in Vivo (고속 내시경적 OFDI 시스템 개발과 이를 이용한 3차원 생체 혈관 내부 이미징)

  • Cho, Han Saem;Jang, Sun-Joo;Oh, Wang-Yuhl
    • Korean Journal of Optics and Photonics
    • /
    • v.25 no.2
    • /
    • pp.67-71
    • /
    • 2014
  • Intravascular optical coherence tomography (OCT) enables imaging of the three-dimensional (3D) microstructure of a blood vessel wall. While 3D vascular visualization provides detailed information of the vessel wall and intraluminal structures, a longitudinal imaging pitch that is several times bigger than the imaging resolution of the system has limited true high-resolution 3D imaging. In this paper we demonstrate high-speed intravascular OCT in vivo, acquiring images at a rate of 350 frames per second. A 47-mm-long rabbit aorta was imaged in 3.7 seconds, after a short flush with contrast agent. The longitudinal imaging pitch was 34 micrometers, comparable to the transverse imaging resolution of the system. Three-dimensional volume rendering showed greatly enhanced visualization of tissue microstructure and stent struts, relative to what is provided by conventional intravascular imaging speeds.

Comparing volumetric and biological aspects of 3D-printed interim restorations under various post-curing modes

  • Song, Gun;Son, Ji-Won;Jang, Ji-Hyun;Choi, Sung-Hyeon;Jang, Woo-Hyung;Lee, Bin-Na;Park, Chan
    • The Journal of Advanced Prosthodontics
    • /
    • v.13 no.2
    • /
    • pp.71-78
    • /
    • 2021
  • Purpose. This study aims to compare the volumetric change, degree of conversion (DOC), and cytotoxicity of 3D-printed restorations post-cured under three different conditions. Materials and Methods. 3D-printed interim restorations were post-cured under three different conditions and systems: 5 min, 30 min, and 24 h. Three-unit and six-unit fixed dental prostheses (n = 30 for each case) were printed; ten specimens from each group were post-cured and then scanned to compare their volumetric changes. Root-mean-squared (RMS) values of the data were acquired by superimposing the scanned files with original files. Thirty disk-shaped specimens were printed to evaluate the DOC ratio. Fourier transform infrared spectroscopy was used to compare the DOCs of 10 specimens from each group. Human gingival fibroblasts were used to measure the cell viability of every specimen (n = 7). The data from this experiment were employed for one-way analysis of variance and Tukey's post-hoc comparisons. Results. Differences between the three-unit restorations were statistically insignificant, regardless of the post-curing conditions. However, for the six-unit restorations, a high RMS value was acquired when the post-curing duration was 30 min. The average DOC was approximately 56 - 62%; the difference between each group was statistically insignificant. All the groups exhibited cell viability greater than 70%, rendering them clinically acceptable. Conclusion. The post-curing conditions influenced the volume when the length of the restoration was increased. However, this deviation was found to be clinically acceptable. Additionally, post-curing did not significantly influence the DOC and cytotoxicity of the restorations.

Effective problem mitigation strategy of lithium secondary battery silicon anode utilized liquid precursor (에틸벤젠을 이용한 실리콘 산화물 음극재의 효과적인 카본 코팅 전략)

  • Sangryeol Lee;Seongsu Park;Sujong Chae
    • Journal of the Korean institute of surface engineering
    • /
    • v.56 no.1
    • /
    • pp.62-68
    • /
    • 2023
  • Silicon (Si) is considered as a promising substitute for the conventional graphite due to its high theoretical specific capacity (3579 mAh/g, Li15Si4) and proper working voltage (~0.3V vs Li+/Li). However, the large volume change of Si during (de)lithiation brings about severe degradation of battery performances, rendering it difficult to be applied in the practical battery directly. As a one feasible candidate of industrial Si anode, silicon monoxide (SiOx) demonstrates great electrochemical stability with its specialized strategy, downsized Si nanocrystallites surrounded by Li+ inactive buffer phase (Li2O and Li4SiO4). Nevertheless, SiOx inherently has the initial irreversible capacity and poor electrical conductivity. To overcome those issues, conformal carbon coating has been performed on SiOx utilizing ethylbenzene as the carbon precursor of chemical vapor deposition (CVD). Through various characterizations, it is confirmed that the carbon is homogeneously coated on the surface of SiOx. Accordingly, the carbon-coated SiOx from CVD using ethylbenzene demonstrates 73% of the first cycle efficiency and great cycle life (88.1% capacity retention at 50th cycle). This work provides a promising synthetic route of the uniform and scalable carbon coating on Si anode for high-energy density.

Design of Acoustic Source Array Using the Concept of Holography Based on the Inverse Boundary Element Method (역 경계요소법에 기초한 음향 홀로그래피 개념에 따른 음원 어레이 설계)

  • Cho, Wan-Ho;Ih, Jeong-Guon
    • The Journal of the Acoustical Society of Korea
    • /
    • v.28 no.3
    • /
    • pp.260-267
    • /
    • 2009
  • It is very difficult to form a desired complex sound field at a designated region precisely as an application of acoustic arrays, which is one of important objects of array systems. To solve the problem, a filter design method was suggested, which employed the concept of an inverse method using the acoustical holography based on the boundary element method. In the acoustical holography used for the source identification, the measured field data are employed to reconstruct the vibro-acoustic parameters on the source surface. In the analogous problem of source array design, the desired field data at some specific points in the sound field was set as constraints and the volume velocity at the surface points of the source plane became the source signal to satisfy the desired sound field. In the filter design, the constraints for the desired sound field are set, first. The array source and given space are modelled by the boundary elements. Then, the desired source parameters are inversely calculated in a way similar to the holographic source identification method. As a test example, a target field comprised of a quiet region and a plane wave propagation region was simultaneously realized by using the array with 16 loudspeakers.

Differential Subsampling with Cartesian Ordering Contrast-Enhanced Magnetic Resonance Angiography for the Preoperative Assessment of Anterolateral Thigh Flap

  • Yunfeng Shen;Xiucun Li;Chao Zhang;Hai Zhong;Weiqiang Dou
    • Korean Journal of Radiology
    • /
    • v.23 no.8
    • /
    • pp.803-810
    • /
    • 2022
  • Objective: To investigate the clinical application of differential subsampling with Cartesian ordering (DISCO) contrast-enhanced (CE) magnetic resonance angiography for anterolateral thigh (ALT) flap transplantation, using operative findings as a reference. Materials and Methods: Thirty patients (21 males and nine females; mean age ± standard deviation, 45.5 ± 15.6 years) who were scheduled to undergo reconstruction with ALT flaps between June 2020 and June 2021 were included in the prospective study. Before ALT flap transplantation, patients were scanned using CE-DISCO imaging. All acquired DISCO images of the 60 lower limbs (both sides from each patient) were analyzed using maximum intensity projection and volume rendering methods. Two experienced radiologists were employed to examine the patterns of the lateral circumflex femoral artery (LCFA), its branches, and perforators and their skin termini, which were compared with the operative findings. Results: Using CE-DISCO, the patterns of the LCFA and its branches were clearly identified in all patients. Four different origins of the LCFA were found among the 60 blood vessels: type I (44/60, 73.3%), type II (6/60, 10.0%), type III (8/60, 13.3%), and type IV (2/60, 3.3%). Owing to a lack of perforators entering the skin, two patients did not undergo ALT flap transplantation. For the remaining 28 patients, the ALT flaps in 26 patients were successfully operated without flap reselection during the operation, while the remaining two patients underwent other surgical procedures due to the thin diameter of the perforator or injury of the perforator during the operation. The success rate of flap transplantation was 92.8% (26/28). All transplanted flaps exhibited good blood supply and achieved primary healing without infection or delayed healing. Conclusion: CE-DISCO imaging can be an effective method for preoperative perforator imaging before ALT flap transplantation.