• 제목/요약/키워드: voltage-to -current converter

검색결과 1,853건 처리시간 0.025초

하나의 스위치를 사용한 영전압-전류 스위칭 벅 컨버터 (Zero Voltage and Zero Current Switching Buck Converter Using a Single Swi)

  • 김기준;김태웅;이성백
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1998년도 하계학술대회 논문집 F
    • /
    • pp.1866-1868
    • /
    • 1998
  • This paper propose zero voltage and zero current switching buck converter using a single switch. This converter is electrically equivalent to two basic buck converter in a cascade. Proposed converter is switching at high frequency and operate in high efficiency at wide load range due to resonant switching.

  • PDF

Active CDS-Clamped L-Type Current-Fed Isolated DC-DC Converter

  • Nguyen, Minh-Khai;Duong, Truong-Duy;Lim, Young-Cheol;Choi, Joon-Ho
    • Journal of Power Electronics
    • /
    • 제18권4호
    • /
    • pp.955-964
    • /
    • 2018
  • In this paper, an active capacitor-diode-switch (CDS) snubber is proposed for L-type current-fed isolated DC-DC converters. The proposed CDS-clamped converter has a number of advantages. It can achieve wide range zero-voltage switching (ZVS) on two switches, a continuous input current with a low ripple, a reduction of one active switch and high efficiency. The operating principles, analysis and parameter design guideline are presented. A 300 W prototype is built to test the proposed converter. Simulation and experimental results are shown at 30 V input voltage and 400 V output voltage.

포워드 컨버터의 스위치 전압 스트레스 감소를 위한 효율적 클램프 (An Efficient Clamp to Reduce Switch Voltage Stress of Forward Converter)

  • 김만고
    • 전력전자학회논문지
    • /
    • 제21권1호
    • /
    • pp.10-18
    • /
    • 2016
  • In this study, an efficient clamp is proposed to reduce the switch voltage stress of a forward converter. The proposed clamp consists of a conventional LC snubber, a tertiary winding, and a diode. When the switch is turned OFF, the magnetizing inductor energy of the transformer is recovered directly into the flyback output, which is the tertiary winding and diode network, instead of circulating in the LC snubber. Therefore, switch voltage stress and circulating current caused by the magnetizing inductor energy are reduced. This condition improves the efficiency of the forward converter with limited switch voltage stress. A theoretical analysis and the design guidelines of the proposed converter are provided. Experimental results are also reported.

축소차원 Luenberger 관측기를 이용한 단상 PWM 컨버터의 고역률 제어 (The High Power Factor Control of a Single Phase PWM Converter using a Reduced-Order Luenberger Observer)

  • 양이우;김영석
    • 대한전기학회논문지:전기기기및에너지변환시스템부문B
    • /
    • 제49권8호
    • /
    • pp.529-535
    • /
    • 2000
  • In this paper, a current control system of a single phase PWM AC/DC converter using a reduced-order Luenberger observer without source voltage sensors is proposed. The sinusoidal input current and unity input power factor are realised based on the estimated source voltage performed by the reduced-order Luenberger observer using actual currents and DC link voltage. The poles of the reduced-order Luenberger observer are placed in the left half plane of s-plane by the pole-placement method in order to acquire the stability of the observer. The magnitude and the phase of the estimated source voltage are used to accomplish the unity power factor. The proposed method is implemented by DSP(Digital Signal Processor). Experimental Results verify that the reduced-order observer estimates the source voltage without the estimation error and the control system accomplishes the unity power factor, and constant DC link voltage.

  • PDF

전압 전류 혼합구동방식을 적용한 동기정류기형 플라이백 DC-DC 컨버터 (A Flyback DC-DC Converter Employing a Synchronous Rectifier Driven by a New Voltage/Current Mixed Method)

  • 이달우;안태영
    • 대한전기학회논문지:전기기기및에너지변환시스템부문B
    • /
    • 제55권9호
    • /
    • pp.472-477
    • /
    • 2006
  • This paper presents a new voltage/current mixed method for driving synchronous rectifiers (SR) adapted to the flyback topology. The synchronous rectifier driven by the proposed voltage/current mixed method can operate at a wide load range with high efficiency. The gate voltage of MOSFET in the synchronous rectifier can be easily controlled by changing the ratio of resistors, irrespective of a line and load fluctuation. A 200W (12V/17A) prototype converter was built and an efficiency of 93% was measured at 10A load current.

A Study on the Secondary Rectification-Methods for the Three-Level Converter

  • Bae, Jin-Yong;Kim, Yong
    • Journal of Electrical Engineering and Technology
    • /
    • 제2권1호
    • /
    • pp.81-88
    • /
    • 2007
  • This paper proposes a coupled inductor-based rectifier of a Three-Level (TL) DC/DC converter and compares the rectification methods of a TL converter. The CICDR- TL (Coupled Inductor Current Doubler Rectifier Three-Level) converter achieves ZVS (Zero Voltage Switching) for the switches in a wide load range. CDR (Current Doubler Rectifier) and CICDR Three-Level converter have low voltage and current ripple. Advantages and disadvantages of topology compared to the rectifier of bridge, center-tap, CDR, and CICDR are discussed. Experimental estimation results are obtained on a 27V, 60A DC/DC TL converter prototype for the 1.8kW, 40kHz IGBT based experimental circuit.

전류제어형 PWM컨버터를 이용한 동기발전기용 여자시스템에 관한연구 (A Study on Excitation System for Synchronous Generator using Current Mode Controlled PWM Converter)

  • 장수진;류동균;서민성;김준호;원충연;배기훈
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2002년도 학술대회논문집
    • /
    • pp.151-156
    • /
    • 2002
  • The output voltage of Synchronous Generator is regulated constantly by field current control in excitation system. A synchronous generator is equipped with an automatic voltage regulator(AVR), which is responsible for keeping the constant output voltage under normal operating conditions about various levels. High frequency PWM converter (Current Mode Control Buck converter) type excitation system for synchronous generator is able to sustain output voltage level properly when the fault condition happened. This paper deals with the design and evaluation of the excitation system controller for a synchronous generator to improve the steady state and transient stability. The simulation and experimental results show that the proposed excitation system is improve the respons time by the AVR(automatic voltage regulator) of 50kW synchronous generator that is applied the current mode control excitation system.

  • PDF

Analysis of a New Parallel Three-Level Zero-Voltage Switching DC Converter

  • Lin, Bor-Ren;Chen, Jeng-Yu
    • Journal of Electrical Engineering and Technology
    • /
    • 제10권1호
    • /
    • pp.128-137
    • /
    • 2015
  • A novel parallel three-level zero voltage switching (ZVS) DC converter is presented for medium voltage applications. The proposed converter includes three sub-circuits connected in parallel with the same power switches to share load current and reduce the current stress of passive components at the output side. Thus, the size of the output chokes is reduced and the switch counts in the proposed converter are less that in the conventional parallel three-level DC/DC converter. Each sub-circuit combines one half-bridge converter and one three-level converter. The transformer secondary windings of these two converters are connected in series in order to reduce the size of output inductor. Due to the three-level circuit topology, the voltage stress of power switches is equal to $V_{in}/2$. Based on the resonant behavior by the output capacitance of power switches and the leakage inductance (or external inductance) at the transition interval, each switch can be turned on under ZVS. Finally, experiments based on a 2 kW prototype are provided to verify the performance of the proposed converter.

2단 역률보상회로를 구성하는 Interleaved 승압형 컨버터의 해석 및 설계 (Analysis and Design of Interleaved Boost Power Factor Corrector on Two Stage AC/DC PFC Converter)

  • 허태원;손영대;김동완;김춘삼;박한석;우정인
    • 대한전기학회논문지:전기기기및에너지변환시스템부문B
    • /
    • 제52권7호
    • /
    • pp.343-351
    • /
    • 2003
  • In this paper, interleaved boost converter is applied as a first-stage converter in switch mode power supply. The first-stage converter plays a role to improve power factor. Interleaved Boost Power Factor Corrector(IBPFC) can reduce input current ripple as a single voltage control loop only without inner current loop, because input current is divided each 50% by two switching devices. Each converter cell is also operated in discontinuous current mode and inductor current of each converter is discontinuous. Total input current which is composed by each converter cell is continuous current. Thus, IBPFC is able to improve input current ripple. IBPFC operating in discontinuous current mode can be classified as six modes from switching state and be carried out state space averaging small signal modeling. A control transfer function is obtained according to the modeling. Not only steady-state characteristics but also dynamic characteristics is considered. Single voltage control loop is also constructed by the control transfer function. From experimental result, improvement of power factor and input current ripple are verified.

Voltage control of three phase rectifier with current-controlled voltage type converter

  • 우명호;정승기
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1991년도 추계학술대회 논문집 학회본부
    • /
    • pp.207-209
    • /
    • 1991
  • This paper deals with voltage control method of PWM rectifier using current-controlled voltage type converter. A linearized model of the current-controlled rectifier is derived, which is used to examine the effect of controller gains to its dynamic responses. Through the simulation, it is shown that the proposed model is generally valid, which is confirmed by experimental results.

  • PDF