• 제목/요약/키워드: voltage-controlled current source

검색결과 223건 처리시간 0.026초

PERFORMANCE EVALUATIONS OF ADVANCED GENERATION IGBTS AND MCT IN SINGLE-ENDED RESONANT INVERTER

  • Ishimaru, N.;Fujita, A.;Hirota, I.;Yamashita, H.;Omori, H.;Nakamizo, Tetsuo;Shirakawa, S.;Nakaoka, Mutsuo.
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 1998년도 Proceedings ICPE 98 1998 International Conference on Power Electronics
    • /
    • pp.851-854
    • /
    • 1998
  • In recent years, a cost-effective voltage-source type single-ended resonant-load inverter using MOS gate power switching devices and its related resonant inverter topologies have been commonly used for induction-heated cooking appliances because of relatively-lowered switching losses, simple circuit topology, low cost, compactness and low harmonic current in utility AC side. This paper present some comparative performance evaluations of IGBTs as sample devices in each generation and MOS controlled Thyristor(MCT) incorporated into the voltage-source type single-ended load resonant inverter for induction-heating rice cookers used for consumer power electronic applications, in which the output power can be regulated on the basis of Frequency Modulation Scheme.

  • PDF

공간벡터 변조방식을 이용한 계통연계형 태양광발전시스템 (Utility Interactive Photovoltaic Generation System using a Space Vector Modulation)

  • 조문택;이충식;이상철
    • 전기학회논문지P
    • /
    • 제59권4호
    • /
    • pp.345-350
    • /
    • 2010
  • This paper presents a Photovoltaic Generation system using a Space Vector Modulation. PWM voltage source inverter using inverter consists of complex type of electric power converter to compensate for the defect, that is solar cell cannot be developed continuously by connecting with the source of electric power for ordinary use. It can cause the effect of saving electric power, from 10 to 20[%]. Synchronous signal and control signal was processed by the 56F8323 microprocessor for stable modulation. Also, Waveforms output current and voltage of system controlled so that phase conforms and can supply electric power that stabilize by the unit power factor.

수중 아-크 방전음원에 관한 연구 (ARC Discharge Sound Source in Underwater)

  • 장재환;장지원
    • 수산해양기술연구
    • /
    • 제21권1호
    • /
    • pp.12-18
    • /
    • 1985
  • 고압변압기의 1차측을 제어하고 2차측에 유도된 전압을 이용한 수중방전음원의 전기음향학적 제특성을 분석.검사한 결과는 다음과 같다. 1. 방전시 2차측 전류는 초기에는 Ohm 법칙을 따르다가 전류가 최고 6.3A 흘러 절연 파괴되었으며, 그 순간 방전음이 생성되었다. 2. 전류인가점과 방전음 생성문의 시간차는 약 3ms였으며, 전압이 최고일 때 절연파괴가 일어나 방전음이 생성되었다. 3. 전극의 끝이 뾰족할수록 2차측 전압이 높을수록 음압수준은 높았다. 4. 뾰족한 형태의 전극은 전극간격이 100cm일 때도 방전이 일어났으며 전극간격이 1cm이상부터 비교적 안정된 방전음이 생성되었다. 5. 방전음의 펄스폭은 약 0.15ms인 Shock Wave였으며, 10HKz 이하의 합성저주파 성분이었다.

  • PDF

IMT2000을 위한 혼성마이크로 동력원 개발에 관한 연구 (A Study on the Development of Hybrid Micro Power Sources for the IMT2000)

  • 김일송;윤명중;김정한;주훈
    • 전력전자학회논문지
    • /
    • 제10권2호
    • /
    • pp.203-210
    • /
    • 2005
  • IMT2000과 같은 휴대용 무선통신 시스템을 위한 혼성마이크로 동력원에 대한 연구를 수행하였다. 혼성마이크로 동력원은 태양전지, 슈퍼커패시터, 리튬이온 전지로 이루어져 있다. 주기적인 펄스성 부하에 대응하기 위하여, 슈퍼 커패시터가 리튬이온 전지와 병렬로 연결되어 펄스전류를 흡수한다. 태양전지는 배터리에 전류를 공금하며, 최대전력점에서 동작하도록 제어된다. 펄스성 부하에도 적용될 수 있는 최대전력점 추적기법이 소개되며, 실험을 통해서 완벽한 추적성능을 입증하였다. 혼성마이크로 동력원들 간의 매칭을 위한 제어기 설계 기법이 제시되며, 실험을 통해 성능을 입증하였다.

불평형 전압 운전시 유도전동기의 동작 특성 해석 (Analysis on the Operation Characteristics of Induction Motor Operated by Unbalanced Voltage)

  • 김종겸;박영진;정종호;이은웅
    • 대한전기학회논문지:전기기기및에너지변환시스템부문B
    • /
    • 제53권6호
    • /
    • pp.372-379
    • /
    • 2004
  • Most of the loads in industrial power distribution systems are balanced and connected to three power systems. However, in the user power distribution systems, most of the loads are single & three phase and unbalanced, generating voltage unbalance. Rotating machines operating on an unbalanced voltage will draw a highly unbalanced current. As a result, the three-phase currents may differ considerably, thus resulting in an increased temperature rise in the machine. This paper presents a scheme on steady states of a three-phase induction motor under unbalanced voltages. The three-phase voltages applied to the stator winding of the studied induction motor are controlled by respectively adjusting the magnitude and phase angle of each phase. The voltage unbalanced factor(VUF) of the three-phase source voltages can then be varied to examine the different values of VUF on machine's operation characteristics.

A New Study on Indirect Vector AC Current Control Method Using a Matrix Converter Fed Induction Motor

  • Lee Hong-Hee;Nguyen Hoang M.
    • Journal of Power Electronics
    • /
    • 제6권1호
    • /
    • pp.67-72
    • /
    • 2006
  • This paper introduces two different types of AC current control methods for an indirect vector controlled induction motor using a matrix converter. The proposed methods combine the advantages of matrix converters with the advantages of the indirect vector AC current control methods. The first proposed method explains the basic idea of the hysteresis current control method for matrix converters and shows its capability and stability in comparison to the conventional method usually used for VSI. With the aid of the special configuration of the matrix converter, we also propose another current method which is modified from the first one in order to reduce both current ripple and torque ripple. Simulation results have verified the feasibility and the effectiveness of the proposed methods.

Microcontroller-Based Improved Predictive Current Controlled VSI for Single-Phase Grid-Connected Systems

  • Atia, Yousry;Salem, Mahmoud
    • Journal of Power Electronics
    • /
    • 제13권6호
    • /
    • pp.1016-1023
    • /
    • 2013
  • Predictive current control offers the potential for achieving more precise current control with a minimum of distortion and harmonic noise. However, the predictive method is difficult to implement and has a greater computational burden. This paper introduces a theoretical analysis and experimental verification for an improved predictive current control technique applied to single phase grid connected voltage source inverters (VSI). The proposed technique has simple calculations. An ATmega1280 microcontroller board is used to implement the proposed technique for a simpler and cheaper control system. To enhance the current performance and to obtain a minimum of current THD, an improved tri-level PWM switching strategy is proposed. The proposed switching strategy uses six operation modes instead of four as in the traditional strategy. Simulation results are presented to demonstrate the system performance with the improved switching strategy and its effect on current performance. The presented experimental results verify that the proposed technique can be implemented using fixed point 8-bit microcontroller to obtain excellent results.

PSII 펄스 시스템의 동적 플라즈마 부하 회로 모델 개발 (Development of a Circuit Model for the Dynamic Plasma Load in a PSII Pulse System)

  • 정경재;최재명;황휘동;김곤호;고광철;황용석
    • 한국진공학회지
    • /
    • 제15권3호
    • /
    • pp.246-258
    • /
    • 2006
  • 음의 고전압의 인가에 따라 반응하는 동적 플라즈마를 부하로 갖는 PSII(plasma source ion implantation) 펄스 시스템을 분석하기 위한 회로 모델을 개발하였다. 플라즈마 내에 삽입된 평판 전극 앞에서의 플라즈마 쉬스의 움직임은 동적 차일드-랑뮤어 쉬스 모델을 따르는 것으로 가정하였다. 표적 전극에 흐르는 전류는 전극에 인가되는 전압과 서로 영향을 주며 변하므로 동적 플라즈마 부하를 전압 의존 전류 원으로 표현하여 자기모순이 없는 회로 모델을 구현하였다. 회로 해석은 Pspice 프로그램을 이용하여 수행하였으며, 다양한 플라즈마 조건과 펄스인가 조건에서의 실험 결과와 비교하여 회로 모델의 타당성을 검증하였다.

전동기 구동을 위한 반포화 적분-비례 제어기 설계 (Anti-windup IP Controller for Motor Drives)

  • 박종규;손병성;유치밍;이순영;신휘범
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 1999년도 전력전자학술대회 논문집
    • /
    • pp.80-83
    • /
    • 1999
  • The windup phenomenon appears and results in performance degradation such as large overshoot, slow settling time when the integral-proportional (IP) controller output is saturated. An anti-windup IP controller is proposed to improve the control performance for the motor drives. The proposed algorithm is applied to the current control of a vector-controlled induction motor driven by a pulse width modulated(PWM) voltage-source inverter. The integral state is separately controlled corresponding to whether the IP controller output is saturated or not. The experimental results show that the current response has much improved performance such as little overshoot and fast settling time.

  • PDF

무정전전원장치의 병렬운전 제어기법에 관한 연구 (A Study on the Parallel Operation Control Technique of On-line UPS System)

  • 곽철훈;최규하
    • 전력전자학회논문지
    • /
    • 제8권6호
    • /
    • pp.585-592
    • /
    • 2003
  • The parallel operation system of UPS is used to increase reliability of power source at critical load. But parallel UPS system has a few defects, impedance is different from each other and circulating current occurs between UPSs, due to line impedance and parameter variation, though controlled by the same synchronization signal. According to such characteristic of parallel UPS, balanced load-sharing control is the most important technique in parallel UPS operation. In this paper, a novel power deviation compensation algorithm is proposed. it is composed of voltage controller to compensate power deviation that be calculated by using active and reactive current deviation between Inverters on synchronous d-q reference frame.