• 제목/요약/키워드: voltage standard

검색결과 979건 처리시간 0.024초

MMC 기반 STATCOM 용 밸브의 성능시험 장치를 위한 새로운 토폴로지 (New Topology for Valve Performance Test Equipment of MMC based STATCOM)

  • 배종우;정재헌;노의철;정용호;백승택;이진희;김영우
    • 전력전자학회논문지
    • /
    • 제22권1호
    • /
    • pp.82-88
    • /
    • 2017
  • This study proposes a new topology for the performance test of a valve consisting of a modular multilevel converter (MMC)-based static synchronous compensator (STATCOM). The conventional valve performance test equipment requires high-voltage AC source of several kV rating because the number of submodules to be tested in a valve should be at least six or eight. However, the power source of the proposed scheme is DC and not AC source. The DC power source voltage range of the proposed test circuit is from several volts to several tens of volts. Therefore, the size and cost for the performance test equipment can be reduced considerably compared with the conventional method. The proposed scheme satisfies the requirements of the IEC 62927 standard. Simulations are conducted for a valve of 50[MVA] MMC-based STATCOM. Experimental results with a scale-downed setup show the validity of the proposed performance test topology.

고압계통 지락고장시 인체안전에 미치는 영향 (Effects of Ground Faults on the Safety of Persons in High Voltage Distribution Systems)

  • 강성만;김한수;이종철;이주철
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2007년도 추계학술대회 논문집
    • /
    • pp.195-197
    • /
    • 2007
  • This paper presents experimental results on the safety of persons due to a ground fault in 22.9 kV-Y distribution system In order to evaluate the touch voltages due to internal ground faults in a step down transformer based on the newly prescribed KS C IEC 60364 standard series, the verification tests in a 22.9 kV multi-grounded neutral system were carried out From the experimental results, it was found that there will be significant potential rise jeopardizing LV equipment insulation in case of separate grounding between HV and LV system and the effective measures against hazardous touch voltages due to a IN side ground fault in the common grounding system between HV and LV system are proposed. As a consequence, it was found that the equipotential bonding is an important prerequisite for the effectiveness of the protective measures for the safety of persons in the common ground system between 22.9 kV-Y and low-voltage grounding system.

  • PDF

절연파괴 특성에 미치는 나노첨가제($SiO_2$)의 영향 (Affect of $SiO_$ depending on the characteristics of break-down)

  • 김정식;정인범;이혁진;최광진;류부형;이충호;홍진웅
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2009년도 하계학술대회 논문집
    • /
    • pp.376-377
    • /
    • 2009
  • In the study the affect of $SiO_$ depending on the characteristics of break-down, we have experimented the break-down for the $SiO_$ and variable temperature change after mading nano $SiO_$ of the diameter 12 [nm] at the epoxy resin. As the experimental results, we have continued that the break-down strength is increased at the adding change but the break-down strength is decreased again as the 0.4 [wt%] standard. Also, the break-down voltage is not changed at 25, 50 [$^{\circ}C$] as the temperate change. But break-down voltage is largely changed when temperate is rising up.

  • PDF

Insulation Test for the 22.9 kV Class HTS Power Transmission Cable

  • J.W. Cho;Kim, H.J.;K.C. Seong;H.M. Jang;Kim, D.W.;Kim, S.H.
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제5권3호
    • /
    • pp.48-51
    • /
    • 2003
  • HTS power transmission cable is expected to transport large electric power with a compact size. We are developing a 3-core, 22.9 kV, 50 MVA class HTS power cable, and each core consists of a conductor and shield wound with Bi-2223 tapes, electrical insulation with laminated polypropylene paper (LPP) impregnated with liquid nitrogen. This paper describes the design and experimental results of the model cable for the 22.9 kV, 50 MVA class HTS power transmission cable. The model cable was used the SUS tapes instead of HTS tapes because of testing the electrical characteristics only. The model cable was 1.3 m long and electrical insulation thickness was 4.5 mm. The model cable was evaluated the partial discharge (PD), AC and Impulse withstand voltage in liquid nitrogen. The AC and Impulse withstands voltage and PD inception stress was satisfied with the standard of Korea Electric Power Corporation (KEPCO) in the test results. The 3-core 22.9 kV, 50 MVA class HTS power cable has been designed and manufactured based on these experimental results.

Enhanced Field Electron Emission from Dielectric Coated Highly Emissive Carbon Fibers

  • Almarsi, Ayman M.;Hagmann, Mark J.;Mousa, Marwan S.
    • Applied Microscopy
    • /
    • 제47권1호
    • /
    • pp.55-62
    • /
    • 2017
  • This paper describes experiments aimed at characterizing the behavior of field electron emitters fabricated by coating carbon fibers with epoxylite resin. Polyacrylonitrile carbon fibers of type VPR-19, thermally treated at $2,800^{\circ}C$, were used. Each was initially prepared in a "uncoated" state, by standard electro polishing and cleaning techniques, and was then examined in a scanning electron microscope. The fiber was then baked overnight in a field electron microscope (FEM) vacuum chamber. Current-voltage characteristics and FEM images were recorded on the following day or later. The fiber was then removed from the FEM, coated with resin, "cured" by baking, and replaced in the FEM. After another overnight bake, the FEM characterization measurements were repeated. The coated fibers had significantly better performance than uncoated fibers. This confirms the results of earlier experiments, and is thought to be due in part to the formation of a conducting channel in the resin over layer. For the coated fiber, lower voltages were needed to obtain the same emission current. The coated fibers have current-voltage characteristics that show smoother trends, with greater stability and repeatability. No switch-on phenomena were observed. In addition, the emission images on the phosphor-coated FEM screen were more concentrated, and hence brighter.

저 전압용 96-dB 신호대잡음비를 갖는 저역통과 디지털 과표본화 잡음변형기의 설계 (Design of a 96-dB SNR and Low-Pass Digital Oversampling Noise-Shaping Coder for Low Supply Voltage)

  • 김대정;손영철
    • 대한전자공학회논문지SD
    • /
    • 제41권5호
    • /
    • pp.91-97
    • /
    • 2004
  • 음성신호 대역을 처리할 수 있는 정밀도를 가지는 디지털 과표본화 잡음변형기를 설계하였다. 디지털 잡음변형기가 IP의 형태로서 최적화 된 설계가 되기 위해, 2.0 V의 저 전압에서 동작할 수 있고 하드웨어 소모면적을 최소화 할 수 있는 방안에 초점을 맞추어 디지털 데이터처리 동작을 위한 곱셈기능, ROM 구조 등의 회로설계를 최적화 할 수 있는 방안을 제시하였다. 설계 및 검증의 방법론에 있어서는 동작수준의 시뮬레이션을 통하여 전체 구조 및 내부 비트 수를 결정하였고, 트랜지스터 수준의 시뮬레이션을 통해 전체 타이밍과 최종 성능을 예측하였다. 또한 0.35-㎛ 표준 CMOS 공정으로써 테스트 칩을 제작한 후 측정하여 시뮬레이션 결과와 부합함을 확인함으로써 제안하는 회로와 설계 방법론이 효과적임을 검증하였다.

용량성 지문센서를 위한 저전력 감지회로 (Low Power Detection Circuit for a Capacitive Fingerprint Sensor)

  • 정승민
    • 한국정보통신학회논문지
    • /
    • 제15권6호
    • /
    • pp.1343-1348
    • /
    • 2011
  • 본 논문에서는 개선된 회로를 적용한 용량성 센서용 저전력 전하분할 방식의 지문센서 감지회로를 제안하고 있다. 제안된 회로는 기존회로에 비하여 전력소모를 크게 줄이고 융선과 골간의 감지전압차를 확대하였다. 설계된 회로는 40MHz 동작주파수, 3.3V 전원에 $0.35{\mu}m$ 표준 CMOS 공정 파라미터를 적용하여 시뮬레이션을 실시하였다. 검증결과 47% 전력소모 감소를 보였고 융선과 골간의 감지 전압 차에 있어서 90% 증가를 나타내었다. 제안된 회로는 면적의 증가 없이 기존 픽셀 레이아웃에 구현되었다.

XLPE 절연케이블의 열화진단 정확도 향상을 위한 VLF tanδ 판정기준 개선 (An Amendment of the VLF tanδ Criteria to Improve the Diagnostic Accuracy of the XLPE-insulated Power Cables)

  • 이재봉;정연하
    • 전기학회논문지
    • /
    • 제59권9호
    • /
    • pp.1644-1651
    • /
    • 2010
  • VLF $tan{\delta}$ diagnosis technology is introduced in IEEE Std 400 and proposed as evaluation criterion in an effective way of detecting water tree which mainly causes the failure of XLPE insulated cables. In order to inspect the accuracy of the VLF $tan{\delta}$ method for XLPE insulated power cables in Korean distribution system, diagnosis for 41 cables which were being serviced in the fields has been carried out and they were removed for AC breakdown voltage test after. Regarding the 41 cables, it was hard to confirm any relation between the VLF $tan{\delta}$ values and AC breakdown voltages and also water tree in the insulation was not detected. However, the other cables were failed several days after the diagnosis of the 41 cables. Water trees were found and their VLF $tan{\delta}$ values were also much higher than the criterion of IEEE standard. It has been ascertained that we need to change the IEEE criteria in order to improve the accuracy of detecting water trees by additional analyzing of field examples of failure and case studies from overseas countries and therefore amended VLF $tan{\delta}$ test voltage and evaluation criteria have been proposed.

가정용 연료전지시스템 계통연계형 전력변환장치의 보호기능 성능평가에 관한 연구 (A Study on the Protective Function Performance Evaluation of Grid-Connected Power Conditioning System for Residential Fuel Cell System)

  • 이정운;서원석;김영규
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2009년도 춘계학술대회 논문집
    • /
    • pp.341-344
    • /
    • 2009
  • In this paper, protective function evaluation was conducted to determine the performance and safety of a power conditioning system(PCS) for 1kW residential fuel cell system. It is essential to have a power quality, grid-connection and safety of PCS. Even though it is under 500ms by KGS-A410 standard, it is shown a rapid response time of 25ms from input under-voltage test. In terms of output over/under-voltage test, it is shown 29.15 and 79.4ms. Especially using anti-islanding test, it is shown all times under 100ms for combination cases of real and reactive power. We confirmed a rapid response characteristics and safety of PCS. The results of this evaluation are being used to develop a new test protocols of PCS.

  • PDF

TRIAC위상 제어 조광기에서의 LED구동을 위한 Single-Stage 준 공진형 PSR(Primary Side Regulation) PWM 컨버터 (Single-Stage Quasi Resonant Type PSR(Primary Side Regulation) PWM Converter for the LED Drive in TRIAC Phase Controlled Dimmer)

  • 한재현;임영철;정영국
    • 조명전기설비학회논문지
    • /
    • 제27권2호
    • /
    • pp.84-94
    • /
    • 2013
  • In case when the existing TRIAC phase controlled dimmer is drove for the LED lighting equipments, there are many problems such as the LED flicker in low phase-angles, the acoustic noise and elements damage by increase of the peak voltage in the input filter capacitor, mulfunction by insufficiency of the TRIAC holding current, and the abnormal oscillation by LC resonant. In this paper, we proposes the single-stage quasi-resonant PSR(Primary Side Regulation) PWM converter, and the design, the simulation and experiment are performed. As a result, it could confirm that the proposed PWM converter is the lighting equipments for LED drive which can alternate the existing 60W class incandescent bulbs and it has the high drive performance of the efficiency 80% and over, the power factor 0.95 and over under the normal voltage 220V. Finally, total harmonic distortion(THD) is gratified with a standard[1] of the lighting equipments and the durability is evaluated as the high reliablilty of 150,000 hours and over.