• Title/Summary/Keyword: voltage signal

Search Result 2,137, Processing Time 0.034 seconds

Design and fabrication of Ka-band high-power, high-efficiency spatial combiner using TM01 mode Transducer (TM01 모드 변환을 이용한 Ka 대역 고출력 고효율 공간 결합기 설계 및 제작)

  • Kim, Hyo-Chul;Cho, Heung-Rae;Lee, Ju-Heun;Lee, Deok-Jae;An, Se-Hwan;Lee, Man-Hee;Joo, Ji-Han;Kim, Hong-Rak
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.21 no.6
    • /
    • pp.25-32
    • /
    • 2021
  • In this study, it proposes a mode converter that is relatively easy to implement and can shorten the transmission line length of the final combining port and it was fabricated and tested by applying it to an 8-way spatial combiner. The proposed mode converter converts the signal converted from the doorknob-shaped circular disk connected to the ground into the TM01 mode by opening it in the circular waveguide. The 8-way waveguide spatial combiner is designed and implemented so that 8 signals input from the H-plane are combined in a circular waveguide at the center, and the final combining mode is TM01. The test results confirmed excellent performance with an insertion loss of less than 0.4dB and a combining efficiency of 95% or more. In addition, it was confirmed that it is suitable for high output by calculating the breakdown voltage and discharge threshold power of the new mode conversion structure through electric field analysis. The results confirmed through this study are expected to be applicable to high-power, high-efficiency SSPA in various fields in the future.

Design of 4th Order ΣΔ modulator employing a low power reconfigurable operational amplifier (전력절감용 재구성 연산증폭기를 사용한 4차 델타-시그마 변조기 설계)

  • Lee, Dong-Hyun;Yoon, Kwang-Sub
    • Journal of IKEEE
    • /
    • v.22 no.4
    • /
    • pp.1025-1030
    • /
    • 2018
  • The proposed modulator is designed by utilizing a conventional structure employing time division technique to realize the 4th order delta-sigma modulator using one op-amp. In order to reduce the influence of KT/C noise, the capacitance in the first and second integrators reused was chosen to be 20pF and capacitance of third and fourth integrators was designed to be 1pF. The stage variable technique in the low power reconfigurable op-amp was used to solve the stability issue due to different capacitance loads for the reduction of KT/C noise. This technique enabled the proposed modulator to reduce the power consumption of 15% with respect to the conventional one. The proposed modulator was fabricated with 0.18um CMOS N-well 1 poly 6 metal process and consumes 305uW at supply voltage of 1.8V. The measurement results demonstrated that SNDR, ENOB, DR, FoM(Walden), and FoM(Schreier) were 66.3 dB, 10.6 bits, 83 dB, 98 pJ/step, and 142.8 dB at the sampling frequency of 256kHz, oversampling ratio of 128, clock frequency of 1.024 MHz, and input frequency of 250 Hz, respectively.

Analysis of acoustic emission parameters according to failure of rock specimens (암석시편 파괴에 따른 acoustic emission 특성인자 분석)

  • Lee, Jong-Won;Oh, Tae-Min;Kim, Hyunwoo;Kim, Min-Jun;Song, Ki-Il
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.21 no.5
    • /
    • pp.657-673
    • /
    • 2019
  • A monitoring method based on acoustic emission (AE) sensor has been widely used to evaluate the damage of structures in underground rock. The acoustic emission signal generated from cracking in material is analyzed as various acoustic emission parameters in time and frequency domain. To investigate from initial crack generation to final failure of rock material, it is important to understand the characteristics of acoustic emission parameters according to the stress ratio and rock strength. In this study, uniaxial compression tests were performed using very strong and weak rock specimen in order to investigate the acoustic emission parameters when the failure of specimen occurred. In the results of experimental tests, the event, root-mean-square (RMS) voltage, amplitude, and absolute energy of very strong rock specimen were larger than those of the weak rock specimen with an increase of stress ratio. In addition, the acoustic emission parameters related in frequency were more affected by specification (e.g., operation and resonant frequency) of sensors than the stress ratio or rock strength. It is expected that this study may be meaningful for evaluating the damage of underground rock when the health monitoring based on the acoustic emission technique will be performed.

Low-cost Impedance Technique for Structural Health Monitoring (임피던스 기반 저비용 구조물 건전성 모니터링 기법)

  • Lee, Jong-Won
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.19 no.12
    • /
    • pp.265-271
    • /
    • 2018
  • This paper presents a method for detecting damage to a structure at low cost using its impedance. The impedance technique is a typical method to detect local damage for structural health monitoring. This is a common technique for estimating damage by monitoring the electro-mechanical admittance signal of the structure. To apply this technique, an expensive impedance analyzer is generally used. On the other hand, it is necessary to develop a low-cost variant to effectively disseminate the technique. In this study, a method based on the transfer impedance using a function generator and digital multimeter, which are generally used in the laboratory instead of an impedance analyzer, was developed. That is, this technique estimates the damage by comparing the damage index using the amplitude ratio of the output voltage measured in the healthy and damaged state. A transfer impedance test was carried out on a steel specimen. By comparing the damage index, the presence of damage could be assessed reasonably. This study is a basic investigation of an impedance-based low-cost damage detection method that can be used effectively for structural health monitoring if supplemented with future research to estimate the damage location and severity.

Study on the Plan to Reduce the EVENT of the Gas Regulator (정압기 EVENT 감소방안 연구)

  • Kang-ok Yun;Tae-jun Eom;Ki-beom Kim;Yong-woo Lee;Hyoung-Min Lee;Byeong-Geun Gong
    • Journal of the Korean Institute of Gas
    • /
    • v.27 no.1
    • /
    • pp.57-62
    • /
    • 2023
  • The Gas Regulator EVENT is a signal sent by the Remote Terminal Unit(RTU) installed in each local gas regulator (hereinafter referred to as "regulator"), and is an abnormal alarm that can be intuitively checked in our client server. This is an important data that enables immediate dispatch order and initial action in the situation room when a regolator abnormality occurs, and can analyze the cause of the regulator abnormality. Looking at the trend of EVENT data for regulator over the past three years, there is a clear trend of increasing unchecked EVENT data. The increase in non-checking event (actual abnormality or noise event) may mean that firstly, mechanical or pressure abnormality occurs in the actual regulator, and secondly, there is no abnormality in the actual regulator, but communication error occurred in the RTU, reset. EVENT Data may be formed as if an abnormality occurred in the static voltage due to an error, sensor error, power failure (instantaneous power failure), etc. Among them, this study analyzed the recently generated unchecked EVENT data to identify critical noise events among RTU errors, which are noise events, and reviewed ways to increase the reliability of Regulator EVENTs by reducing them.

Development and Characterization of Hafnium-Doped BaTiO3 Nanoparticle-Based Flexible Piezoelectric Devices (Hf 도핑된 BaTiO3 나노입자 기반의 플렉서블 압전 소자 개발 및 특성평가)

  • HakSu Jang;Hyeon Jun Park;Gwang Hyeon Kim;Gyoung-Ja Lee;Jae-Hoon Ji;Donghun Lee;Young Hwa Jung;Min-Ku Lee;Changyeon Baek;Kwi-Il Park
    • Journal of Sensor Science and Technology
    • /
    • v.33 no.1
    • /
    • pp.34-39
    • /
    • 2024
  • Energy harvesting technology that converts the wasted energy resources into electrical energy is emerging as a semipermanent power source for self-powered electronics and wireless low-power sensor systems. Among the various energy conversion techniques, flexible piezoelectric energy harvesters (f-PEHs), using materials with piezoelectric effects, have attracted significant interest because they can harvest a small mechanical energy into electrical signals without constraints of time and space in various environments. In this study, we used a flexible piezoelectric composite film fabricated by dispersing BaHfxTi(1-x)O3 (x = 0, 0.01, 0.05, 0.1) piezoelectric powders inside a polymeric matrix to facilitate f-PEHs. The fabricated f-PEH with optimal Hf contents (x = 0.05) generated a maximum output voltage of 0.95 V and current signal of 130 nA with stable electrical/mechanical disabilities under periodically bending deformations. In addition, we demonstrated a cantilever-type f-PEH and investigated its potential as a sensor by characterizing the output performance under mechanical vibrations at various frequencies. This study provides the breakthrough for realizing self-powered energy harvesting and sensing systems by adopting the lead-free piezoelectric composites under vibrational environments.

Structural Behavior of Mixed $LiMn_2O_4-LiNi_{1/3}Co_{1/3}Mn_{1/3}O_2$ Cathode in Li-ion Cells during Electrochemical Cycling

  • Yun, Won-Seop;Lee, Sang-U
    • Proceedings of the Materials Research Society of Korea Conference
    • /
    • 2011.05a
    • /
    • pp.5-5
    • /
    • 2011
  • The research and development of hybrid electric vehicle (HEV), plug-in hybrid electric vehicle (PHEV) and electric vehicle (EV) are intensified due to the energy crisis and environmental concerns. In order to meet the challenging requirements of powering HEV, PHEV and EV, the current lithium battery technology needs to be significantly improved in terms of the cost, safety, power and energy density, as well as the calendar and cycle life. One new technology being developed is the utilization of composite cathode by mixing two different types of insertion compounds [e.g., spinel $LiMn_2O_4$ and layered $LiMO_2$ (M=Ni, Co, and Mn)]. Recently, some studies on mixing two different types of cathode materials to make a composite cathode have been reported, which were aimed at reducing cost and improving self-discharge. Numata et al. reported that when stored in a sealed can together with electrolyte at $80^{\circ}C$ for 10 days, the concentrations of both HF and $Mn^{2+}$ were lower in the can containing $LiMn_2O_4$ blended with $LiNi_{0.8}Co_{0.2}O_2$ than that containing $LiMn_2O_4$ only. That reports clearly showed that this blending technique can prevent the decline in capacity caused by cycling or storage at elevated temperatures. However, not much work has been reported on the charge-discharge characteristics and related structural phase transitions for these composite cathodes. In this presentation, we will report our in situ x-ray diffraction studies on this mixed composite cathode material during charge-discharge cycling. The mixed cathodes were incorporated into in situ XRD cells with a Li foil anode, a Celgard separator, and a 1M $LiPF_6$ electrolyte in a 1 : 1 EC : DMC solvent (LP 30 from EM Industries, Inc.). For in situ XRD cell, Mylar windows were used as has been described in detail elsewhere. All of these in situ XRD spectra were collected on beam line X18A at National Synchrotron Light Source (NSLS) at Brookhaven National Laboratory using two different detectors. One is a conventional scintillation detector with data collection at 0.02 degree in two theta angle for each step. The other is a wide angle position sensitive detector (PSD). The wavelengths used were 1.1950 ${\AA}$ for the scintillation detector and 0.9999 A for the PSD. The newly installed PSD at beam line X18A of NSLS can collect XRD patterns as short as a few minutes covering $90^{\circ}$ of two theta angles simultaneously with good signal to noise ratio. It significantly reduced the data collection time for each scan, giving us a great advantage in studying the phase transition in real time. The two theta angles of all the XRD spectra presented in this paper have been recalculated and converted to corresponding angles for ${\lambda}=1.54\;{\AA}$, which is the wavelength of conventional x-ray tube source with Cu-$k{\alpha}$ radiation, for easy comparison with data in other literatures. The structural changes of the composite cathode made by mixing spinel $LiMn_2O_4$ and layered $Li-Ni_{1/3}Co_{1/3}Mn_{1/3}O_2$ in 1 : 1 wt% in both Li-half and Li-ion cells during charge/discharge are studied by in situ XRD. During the first charge up to ~5.2 V vs. $Li/Li^+$, the in situ XRD spectra for the composite cathode in the Li-half cell track the structural changes of each component. At the early stage of charge, the lithium extraction takes place in the $LiNi_{1/3}Co_{1/3}Mn_{1/3}O_2$ component only. When the cell voltage reaches at ~4.0 V vs. $Li/Li^+$, lithium extraction from the spinel $LiMn_2O_4$ component starts and becomes the major contributor for the cell capacity due to the higher rate capability of $LiMn_2O_4$. When the voltage passed 4.3 V, the major structural changes are from the $LiNi_{1/3}Co_{1/3}Mn_{1/3}O_2$ component, while the $LiMn_2O_4$ component is almost unchanged. In the Li-ion cell using a MCMB anode and a composite cathode cycled between 2.5 V and 4.2 V, the structural changes are dominated by the spinel $LiMn_2O_4$ component, with much less changes in the layered $LiNi_{1/3}Co_{1/3}Mn_{1/3}O_2$ component, comparing with the Li-half cell results. These results give us valuable information about the structural changes relating to the contributions of each individual component to the cell capacity at certain charge/discharge state, which are helpful in designing and optimizing the composite cathode using spinel- and layered-type materials for Li-ion battery research. More detailed discussion will be presented at the meeting.

  • PDF

Abosrbed Dose Measurements and Phantom Image Ecaluation at Minimum CT Dose for Pediatric SPECT/CT Scan (소아 SPECT/CT 검사를 위한 최저조건에서의 피폭선량측정 및 팬텀의 영상평가)

  • Park, Chan Rok;Choi, Jin Wook;Cho, Seong Wook;Kim, Jin Eui
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.18 no.1
    • /
    • pp.82-88
    • /
    • 2014
  • Purpose: The purpose of study was to evaluate radiation dose for pediatric patients by changing tube voltage (kVp) and tube current (mA) at minimum conditions. By evaluating radiation dose, we want to provide dose reduction for pediatric patients and maintain good quality of SPECT/CT images. Materials and Methods: Discovery NM/CT 670 Scanne was used as SPECT/CT. Tube voltages are 80 and 100 kvP. Tube currents are 10, 15, 20, 25 mA. Using PMMA (Polymethyl methacrylate) Phantom, radiation dose which were calculated at center and peripheral dose and SNRD (Signal to Noise Ratio Dose) were evaluated. Using the CT performance phantom, spatial resolution was evaluated as the MTF (Modulation Transfer Function) graph. Jaszczak phantom was used for SPECT image evaluation by CNR (Contrast to Noise to Ratio). Results: Radiation dose using the PMMA phantom was higher peripheral dose than center dose about 7%. SNRD were 7.8, 8.2, 8.3, 8.8, 8.8, 9.9, 9.8, 9.6 for 80 kVp 10, 15, 20, 25 mA, 100 kVp 10, 15, 20, 25 mA. We can distinguish 35, 45, 70, 71, 52, 58, 90, 110 linepair for 80 kVp 10, 15, 20, 25 mA, 100 kVp 10, 15, 20, 25 mA at resolution with MTF. CNR of SPECT images using CT attenuation map were 57.8, 57.7, 57.1, 56.7, 56.6, 56.7, 56.7, 56.7% for 80 kVp 10, 15, 20, 25 mA, 100 kVp 10, 15, 20, 25 mA. Conclusion: In this study, radiation dose for pediatric patients showed decreased low dose condition. And SNRD value was similar in all condition. Resolution showed higher value at 100kVp than 80kVp. for CNR, there was no significant difference. we should take additional study to prove better quality and dose reduction.

  • PDF

Evaluation of Virtual Grid Software (VGS) Image Quality for Variation of kVp and mAs (관전압과 관전류량 변화에 대한 가상 그리드 소프트웨어(VGS) 화질평가)

  • Chang-gi Kong
    • Journal of the Korean Society of Radiology
    • /
    • v.17 no.5
    • /
    • pp.725-733
    • /
    • 2023
  • The purpose of this study is to evaluate the effectiveness of virtual grid software (VGS). The purpose of this study is to evaluate the changes in energy and object thickness by dividing the use of VGS into two cases (Without-VGS) without using a movable grid. We attempted to determine the effectiveness of VGS by acquiring images using a chest phantom and a thigh phantom and analyzing SNR and CNR. In the chest phantom and femoral phantom, the tube flow was fixed at 2.5 mAs, and the tube voltage was changed by 10 kVp from 60 to 100 kVp to measure SNR and CNR, and SNR was about 1.09 to 8.86% higher in the chest phantom than in Without-VGS, and CNR was 4.18 to 14.56% higher in the VGS than in Without-VGS. And in the femoral phantom, SNR was about 9.78 to 18.05% higher in VGS than in Without-VGS, and CNR was 21.07 to 44.44% higher in VGS than in Without-VGS. The tube voltage was fixed at 70 kVp in the chest phantom and the femoral phantom, and the amount of tube current was changed at 2.5 to 16 mAs, respectively, and after X-ray irradiation, SNR and CNR were measured in the chest phantom, which was about 1.49 to 11.11% higher in VGS than in Without-VGS, and CNR was 4.76 to 13.40% higher in VGS than in Without-VGS. And in the femoral phantom, SNR was about 2.22 to 17.38% higher in VGS than in Without-VGS, and CNR was 13.85 to 40.46% higher in VGS than in Without-VGS. Therefore, if an inspection is required with a mobile X-ray imaging device, it is believed that good image quality can be obtained by using VGS in an environment where it is difficult to use a mobile grid, and it is believed that the use of mobile X-ray devices can be increased.

A Study on Bismuth tri-iodide for X-ray direct and digital imagers (직접방식 엑스선 검출기를 위한 $BiI_3$ 특성 연구)

  • Lee, S.H.;Kim, Y.S.;Kim, Y.B.;Jung, S.H.;Park, J.K.;Jung, W.B.;Jang, M.Y.;Mun, C.W.;Nam, S.H.
    • Journal of the Korean Society of Radiology
    • /
    • v.3 no.2
    • /
    • pp.27-31
    • /
    • 2009
  • Now a days, the Medical X-ray equipments has become digitalized from analog type such as film, cassette to CR, DR. And many scientists are still researching and developing the Medical X-ray equipment. In this study, we used the Bismuth tri-iodide to conversion material for digital X-ray equipments and we couldn't get the satisfying result than previous study, but it opened new possibility to cover the disadvantage of a-Se is high voltage aplly and difficultness of make. In this paper, we use $BiI_3$ powder(99.99%) as x-ray conversion material and make films that have thickness of 200um and the film size is $3cm{\times}3cm$. Also, we deposited an ITO(Indium Tin Oxide) electrode as top electrode and bottom electrode using a Magnetron Sputtering System. To evaluate a characteristics of the produced films, an electrical and structural properties are performed. Through a SEM analysis, we confirmed a surface and component part. And to analyze the electrical properties, darkcurrent, sensitivity and SNR(Signal to Noise Ratio) are measured. Darkcurrent is $1.6nA/cm^2$ and sensitivity is $0.629nC/cm^2$ and this study shows that the electrical properties of x-ray conversion material that made by screen printing method are similar to PVD method or better than that. This results suggest that $BiI_3$ is suitable for a replacement of a-Se because of the reduced manufacture processing and improved yield.

  • PDF