• Title/Summary/Keyword: voltage signal

Search Result 2,137, Processing Time 0.03 seconds

The Performance Analysis of the Parameter Extracting Technique for the Vibration Monitoring System in High Voltage Motor (고압전동기용 진동 감시 시스템의 계수 추출기법 성능 분석)

  • Park, Jung-Cheul;Lee, Dal-Ho
    • The Journal of Korea Institute of Information, Electronics, and Communication Technology
    • /
    • v.12 no.5
    • /
    • pp.529-536
    • /
    • 2019
  • In this paper, the signals of the sensor for extracting characteristic parameters of the rotor are collected and the performance of the extraction technique is analyzed. To this end, a vibration test league was developed for conducting model tests to analyze the signal characteristics under normal operation. As a result, it is judged that no change in the measured the raw data amplitude will occur in the acceleration sensor with the unbalanced mass measured from the acceleration sensor. Performing FFT showed a significant increase in amplitude of the rotational frequency of 20 Hz as the unbalanced mass increased. The analysis results according to the change in the unequal mass of the speed sensor also showed a significant increase in the 1X Harmonics component, such as the acceleration sensor. There was no change in the amplitude of the acceleration sensor data when the misalignment occurred, and for the Envelope data, the amplitude of 2X (40 Hz) was increased depending on the degree of misalignment. The velocity sensor at change of misalignment also showed similar results to the acceleration sensor, and the peak was reduced at 600 Hz as the load increased in the frequency spectrum.

An experimental analysis of vibration-induced noise isolation characteristics of a sonar acoustic sensor (소나 음향센서의 진동유기 소음 차단 특성에 대한 실험적 연구)

  • Kim, Kyungseop;Je, Yub;Kim, Ho-Jun;Cho, Yo-Han;Lee, Jeong-Min;Kim, Donghyeon;Chang, Woosuk
    • The Journal of the Acoustical Society of Korea
    • /
    • v.38 no.2
    • /
    • pp.193-199
    • /
    • 2019
  • In this paper, the results of underwater vibration experiment are analyzed to verify platform vibration-induced noise isolation characteristics of a hull-mounted acoustic sensor. The experimental condition causing platform vibration-induced noise is generated using the mock-up hull, where the acoustic sensor is installed, with shaker in an acoustic water tank. The performance indices of ATF (Acceleration Transfer Function), AVS (Acceleration Voltage Sensitivity), and IL (Insertion Loss) for the acoustic sensor are calculated from the output of the standard accelerometers, which are installed on the mock-up hull and the acoustic sensor, and the output signal of the acoustic sensor. The frequency-dependent noise isolation characteristics of the acoustic sensor are analyzed based on the calculated performance indices and an effectiveness of the experiment is examined.

Using Taguchi design of experiments for the optimization of electrospun thermoplastic polyurethane scaffolds

  • Nezadi, Maryam;Keshvari, Hamid;Yousefzadeh, Maryam
    • Advances in nano research
    • /
    • v.10 no.1
    • /
    • pp.59-69
    • /
    • 2021
  • Electrospinning is a cost-effective and versatile method for producing submicron fibers. Although this method is relatively simple, at the theoretical level the interactions between process parameters and their influence on the fiber morphology are not yet fully understood. In this paper, the aim was finding optimal electrospinning parameters in order to obtain the smallest fiber diameter by using Taguchi's methodology. The nanofibers produced by electrospinning a solution of Thermoplastic Polyurethane (TPU) in Dimethylformamide (DMF). Polymer concentration and process parameters were considered as the effective factors. Taguchi's L9 orthogonal design (4 parameters, 3 levels) was applied to the experiential design. Optimal electrospinning conditions were determined using the signal-to-noise (S/N) ratio with Minitab 17 software. The morphology of the nanofibers was studied by a Scanning Electron Microscope (SEM). Thereafter, a tensile tester machine was used to assess mechanical properties of nanofibrous scaffolds. The analysis of DoE experiments showed that TPU concentration was the most significant parameter. An optimum combination to reach smallest diameters was yielded at 12 wt% polymer concentration, 16 kV of the supply voltage, 0.1 ml/h feed rate and 15 cm tip-to-distance. An empirical model was extracted and verified using confirmation test. The average diameter of nanofibers at the optimum conditions was in the range of 242.10 to 257.92 nm at a confidence level 95% which was in close agreement with the predicted value by the Taguchi technique. Also, the mechanical properties increased with decreasing fibers diameter. This study demonstrated Taguchi method was successfully applied to the optimization of electrospinning conditions for TPU nanofibers and the presented scaffold can mimic the structure of Extracellular Matrix (ECM).

Design of Compact Wideband Loop Antenna with Horizontal Slits for Terrestrial DTV and UHD TV Applications (지상파 DTV 및 UHD TV용 수평 슬릿이 추가된 소형 광대역 루프 안테나 설계)

  • Yeo, Junho;Lee, Jong-Ig
    • Journal of Advanced Navigation Technology
    • /
    • v.24 no.6
    • /
    • pp.581-586
    • /
    • 2020
  • In this paper, the design process and method for a compact wideband loop antenna for terrestrial digital TV (DTV) and ultra high definition (UHD) TV applications was proposed. Horizontal slits were added on the two circular sectors of the proposed loop antenna in order to miniaturize the existing wideband loop antenna consisting of a square loop and two circular sectors. A CPW transmission line was inserted in the center of the lower circular sector as a feed line. The CPW feed line was designed using the 75 ohm port impedance for DTV and UHD TV applications, and a tapered center-signal line was designed to improve the impedance matching. The final designed antenna was fabricated on an FR4 substrate with a thickness of 0.8 mm. The experiment results show that the proposed compact loop antenna operates in the frequency band of 444.3-820.1 MHz for a VSWR < 2, which fully covers the DTV and UHD TV bands.

Evaluation for the Usefulness of Copper Filters according to Mode Change in Digital Radiography System (DR 시스템에서 모드 변화에 따른 구리필터의 유용성 평가)

  • Kim, Jae-Kyeom;Kim, Jeong-Koo
    • Journal of radiological science and technology
    • /
    • v.44 no.1
    • /
    • pp.39-46
    • /
    • 2021
  • This study confirmed the usefulness of the copper filter according to the mode change by comparing and analyzing the energy change according to the application of the copper filter and the change in effective dose and image quality according to the distance to the subject in the DR(Digital Radiography) system. The average energy increased when the copper filter was applied and the reduction rate by 50% of mAs was increased as the thickness of the copper filter increased according to the application of the 10 kVp rule in AEC mode. The effective dose decreased as the thickness increased when the copper filter was applied in AEC(Automatic Exposure Control) mode and manual mode according to the application of the 10 kVp rule, and the decrease rate decreased with increasing 10 kVp increments. As a result of analyzing the dicom images for AEC mode and manual mode with Image J. the PSNR(Peak Signal to Noise Ratio) values were approximate values of less than 30 dB for each mode and for each copper filter thickness. When the copper filter was applied, the average energy increased, so when the 10 kVp rule was applied, the mAs for each mode could be reduced, and the effective dose could also be reduced. However, as the distance and tube voltage increased, the reduction rate of mAs decreased, and the quality of the image was found to decrease when the copper filter was applied, but there was no difference in quality of the image when the copper filter thickness increased.

Measurement of the ICRH antenna phasing using antenna strap probe based diagnostic system in EAST tokamak

  • Liu, L.N.;Liang, Q.C.;Yang, H.;Zhang, X.J.;Yuan, S.;Mao, Y.Z.;Zhang, W.;Zhu, G.H.;Wang, L.;Qin, C.M.;Zhao, Y.P.;Cheng, Y.;Zhang, K.
    • Nuclear Engineering and Technology
    • /
    • v.54 no.10
    • /
    • pp.3614-3619
    • /
    • 2022
  • To operate the ion cyclotron resonance heating (ICRH) antennas in a better heating state and produce relatively low impurities, it is necessary to control the antenna spectrum by changing the antenna phasing. As the electrical length of the antenna feeding transmission lines is changing as a matter of the standing wave pattern at the ceramic supports, 90° elbows, T-connectors and antenna loops, we chose to measure the current at the grounding points of the antenna loops by antenna strap probe. The voltage drops along a small, several millimeter-long paths at the end of the antenna loops give a signal that is proportional to the current in the antenna loop. Through the simulation of the antenna strap probe and the actual measurement of the antenna phasing under vacuum conditions, the reliability of the antenna strap probe based diagnostic system have been successfully proved. Moreover, this system was successfully applied to the ICRH daily experiments in the spring of 2021. In the near future, the active real-time feedback control of the antenna phasing system will be developed based on this diagnostic system in the EAST tokamak.

High Power W-band Power Amplifier using GaN/Si-based 60nm process (GaN/Si 기반 60nm 공정을 이용한 고출력 W대역 전력증폭기)

  • Hwang, Ji-Hye;Kim, Ki-Jin;Kim, Wan-Sik;Han, Jae-Sub;Kim, Min-Gi;Kang, Bong-Mo;Kim, Ki-chul;Choi, Jeung-Won;Park, Ju-man
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.22 no.4
    • /
    • pp.67-72
    • /
    • 2022
  • This study presents the design of power amplifier (PA) in 60 nm GaN/Si HEMT technology. A customized transistor model enables the designing circuits operating at W-band. The all matching network of the PA was composed of equivalent transformer circuit to reduce matching loss. And then, equivalent transformer is several advantages without any additional inductive devices so that a wideband power characteristic can be achieved. The designed die area is 3900 ㎛ × 2300 ㎛. The designed results at center frequency achieved the small signal gain of 15.9 dB, the saturated output power (Psat) of 29.9 dBm, and the power added efficiency (PAE) of 24.2% at the supply voltage of 12 V.

High Noise Density Median Filter Method for Denoising Cancer Images Using Image Processing Techniques

  • Priyadharsini.M, Suriya;Sathiaseelan, J.G.R
    • International Journal of Computer Science & Network Security
    • /
    • v.22 no.11
    • /
    • pp.308-318
    • /
    • 2022
  • Noise is a serious issue. While sending images via electronic communication, Impulse noise, which is created by unsteady voltage, is one of the most common noises in digital communication. During the acquisition process, pictures were collected. It is possible to obtain accurate diagnosis images by removing these noises without affecting the edges and tiny features. The New Average High Noise Density Median Filter. (HNDMF) was proposed in this paper, and it operates in two steps for each pixel. Filter can decide whether the test pixels is degraded by SPN. In the first stage, a detector identifies corrupted pixels, in the second stage, an algorithm replaced by noise free processed pixel, the New average suggested Filter produced for this window. The paper examines the performance of Gaussian Filter (GF), Adaptive Median Filter (AMF), and PHDNF. In this paper the comparison of known image denoising is discussed and a new decision based weighted median filter used to remove impulse noise. Using Mean Square Error (MSE), Peak Signal to Noise Ratio (PSNR), and Structure Similarity Index Method (SSIM) metrics, the paper examines the performance of Gaussian Filter (GF), Adaptive Median Filter (AMF), and PHDNF. A detailed simulation process is performed to ensure the betterment of the presented model on the Mini-MIAS dataset. The obtained experimental values stated that the HNDMF model has reached to a better performance with the maximum picture quality. images affected by various amounts of pretend salt and paper noise, as well as speckle noise, are calculated and provided as experimental results. According to quality metrics, the HNDMF Method produces a superior result than the existing filter method. Accurately detect and replace salt and pepper noise pixel values with mean and median value in images. The proposed method is to improve the median filter with a significant change.

Compensation of low Frequency Resonance in Current Driven Loudspeakers using DSP (DSP를 이용한 전류구동 스피커의 저주파 공진 보상)

  • Park, Jong-phil;Eun, Changsoo
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2021.05a
    • /
    • pp.584-588
    • /
    • 2021
  • The impedance of the speaker is likely to be recognized as a fixed value. However, speaker impedance continues to vary with frequency variation, especially larger in resonant frequency region. The sound pressure level of loudspeakers is determined by the current flowing throughout the coil that consists loudspeakers. If loudspeakers are driven by voltage, sound pressure level of the loudspeaker is distorted by the variation of loudspeaker impedance. Current-drive of loudspeakers can solve this problem, but distortion of sound pressure level occurs in low frequencies due to resonance. The distortion can degrade the sound quality of the sound system. So to solve this problem, In this paper, we propose a resonance compensation circuit using DSP. we simulates audio systems using an equivalent model of loudspeakers to verify distortion of sound pressure level due to impedance variation and propose a circuit to compensate it. The proposed circuit is configured using a state variable filter and it can adjust the center frequency and output, so it will be used various sound systems.

  • PDF

Performance Evaluation of an Electrometer for Quality Control and Dosimetry in Radiation Therapy (방사선 치료의 정도관리 및 선량측정에 이용되는 전리계의 성능평가)

  • Kim, Chang-Seon;Kim, Chul-Yong;Park, Myung-Sun
    • Progress in Medical Physics
    • /
    • v.11 no.2
    • /
    • pp.123-130
    • /
    • 2000
  • The performance of an electrometer directly affects on the accuracy and precision in radiation dosimetry. This study is to list of the quality control for maintaining performance and to perform evaluation tests of an electrometer. Performance tests selected include proper polarizing voltages, warm-up and equalization time, leakages, long-term stability, linearity, and effect of ambient conditions. An electrometer connected with a rigid stem ionization chamber was evaluated with a Strontium-90 check device. Bias voltage was measured directly on the input socket. Equalization time is the time required for reaching threshold of charged state after the power is on or the bias voltage is changed. Pre- and post-signal leakages are defined as the accumulation of signal with no exposure and after exposure, respectively. Over three months period, the electrometer's long-term stability was measured by comparison of the temperature-pressure corrected readings. Linearity was expressed as the deviation of readings from multiple short exposures from one continuous exposure. Effect of ambient conditions was expressed as the zero drift of the electrometer over 17-34$^{\circ}C$ temperature ranges. For two nominal values, 300 and 500 volts, measured voltages were lower by 2.5 and 5.8%, respectively. The warm-up time, 20 minutes, was longer than the lamp time by 9 minutes and the equalization time was less than 1 minute. Without exposure, the zero-drift was 0.002 scale-unit in 15 minutes and the leakage after 10 minutes exposure was minimal. The IQ-4 was stable over 99.4% for three-month periods. Deviation from the linearity was 0.9% for measurement scale, 0.000-9.991. Over 17-34$^{\circ}C$ temperature range, the zero-drift was minimal, less than 0.2%. For a clinically-used electrometer, a list for the basic peformance evaluations is proposed. By running this program, the measurement error using an electrometer can be reduced and in turn the improvement in accuracy and precision of radiation dosimetry can be achieved.

  • PDF