• Title/Summary/Keyword: voltage flicker

Search Result 100, Processing Time 0.025 seconds

Analysis of Active Characteristic the Low-voltage Circuit Breaker for Harmonics (고조파에 의한 저압용 차단기의 동작특성 해석)

  • Choi, M.G.;Jeong, B.H.;Park, J.C.;Kim, H.G.;Mok, H.S.;Choe, G.H.
    • Proceedings of the KIEE Conference
    • /
    • 2005.07b
    • /
    • pp.1474-1476
    • /
    • 2005
  • Because MCCB, ELB, etc. discharge both technical and economical duty, it is important that the study of circuit breaker guarantee high-performance and realize the power distribution system with reliability. Because of complexity electrical equipment, the accident with imbalance and flicker occur often according to technical improvement. However, study of accident with harmonics remains. In this paper, the essential characteristic of circuit breaker is introduced. To analysis operation of circuit breaker, theoretical model and several simulations have been performed.

  • PDF

The Development of Integrated Power Quality Diagnosis System for Power System (전력계통 전력품질 통합진단시스템 개발)

  • Kwak, N.H.;Jeon, Y.S.;Park, S.H.;Lee, I.M.;Park, H.C.
    • Proceedings of the KIEE Conference
    • /
    • 2005.07a
    • /
    • pp.277-279
    • /
    • 2005
  • Recently, due to the increase of power conversion devices and nonlinear loads with the development of information, communication and control technologies, the instantaneous minute interruption factors such as voltage & current harmonics, surge occurring frequency, instantaneous voltage variation, voltage unbalance, flicker etc. have greatly threatened the power quality, and the deterioration of electric power facilities and the functional error of controllers are increasing. As such an instantaneous minute interruption appears to be small and local, accurate evaluation with measurement is difficult and total analysis system is required through a wide range of power quality effect analysis such as the simultaneous measurement on various power supply phenomena and the analysis on the interrelation with system loads. Most of conventional power quality diagnosis equipments have beer developed and applied, which were able to measure the stability rate of frequency, the stability rate of voltage, the electricity-failure duration etc, However, they were insufficient to analyze the system present situation, understand the cause of the failure occurred by the problem of power quality and analyze out the phenomena. Accordingly, this study will address the development of the system for a wide range of power quality diagnosis over the present level, the system for supporting the determination such as the analysis on risk factors, failure mode and impact, the system for harmonic evaluation based on international standards(IEC 61000 Series) and the total power quality diagnosis network & system with the extension and openness as a local and national-scale broadband power quality diagnosis system.

  • PDF

A Study on T5 28W Fluorescent Lamp Ballast Using a Piezoelectric Transformer and One-chip Microcontroller (One Chip Microcontroller와 압전변압기를 이용한 T5 28W 형광등용 전자식 안정기에 관한 연구)

  • 황락훈;류주현;장은성;조문택;안익수;홍재일
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.8 no.1
    • /
    • pp.70-79
    • /
    • 2003
  • In this paper, T5 28-watt fluorescent lamp ballast using a piezoelectric transformer is fabricated and its characteristic is investigated. Developed electronic ballast is composed of basic circuits and blocks, such as rectifier part, active power factor corrector part, frequency oscillation part using microcontroller and feedback control, piezoelectric transformer and resonant half bridge inverters. The fabricated ballast uses to variable frequency methode in external so exciting that the frequency of piezoelectric transformer could be generated by voltage control oscillator using microcontroller(AT90S4433). The current of fluorescent lamp is detected by feedback control circuit. The signal of inverter output is received using Piezoelectric transformer, and then its output transmitted to fluorescent lamp. Traditional electromagnetic ballasts operated at 50-60Hz have been suffered from noticeable flicker, high loss, large crest factor and heavy weight. A new electronic ballast is operated at high frequency about 75kHz, and then Input power factor, distortion of total harmonic and lamp current crest factor are measured about 0.9!35, 12H and 1.5, respectively Accordingly, the traditional ballast is by fabricated electronic ballast using piezoelectric transformer and voltage control oscillator because of its lighter weight, high efficiency, economic merit and saving energy.

Harmonics Analysis for Electric Arc Furnace According to the Operation Condition (전기 아크로 운전 상태에 따른 고조파 해석)

  • Kim, Jae-Chul;Park, Kyung-Ho;Park, Hyun-Teak;Moon, Jong-Fil;Im, Sang-Kug;Son, Hag-Sig
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.18 no.5
    • /
    • pp.118-125
    • /
    • 2004
  • The use of electric arc furnace has been increasing as the steel consumption is increasing and the operation technique of electric arc furnace are developing. But as the use of electric arc furnace is increased, the furnace have produced the adverse effects of power quality: voltage and current harmonics, voltage and current imbalances, low power factor, and voltage flicker. One of the power quality problems, the harmonic have the characteristics of the time-varying and non-linear. This paper analyzed the harmonics for the various operation conditions of electric arc furnace. The power system model with electric arc furnace have been made, and the harmonic's effects on the power system has been analyzed according to the various operating conditions, first melting, second melting, so on. Also, the filter reducing the harmonic components have been designed and its effects on the power system have been examined.

Research on the Effect of Interconnected Distributed Wind Power Generation(225[kV], AC Link Method) on Power Quality in System (연계형 풍력발전설비(225[kV], AC 링크방식)가 전력계통의 전원 품질에 미치는 영향에 관한 연구 분석)

  • Na, Chae-Dong;Park, Jung-Shin
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.24 no.6
    • /
    • pp.147-153
    • /
    • 2010
  • When small scale wind and solar power generation systems are connected to conventional power distribution system. It is worried that it can affect the quality of electricity such as voltage variation, power factor, frequency, harmonics and flicker. Therefore, in this research, in order to investigate the effects of wind power generation equipments(AC link method) on electrical power quality, when they are connected to distribution system. Power quality analyzer was installed respectively at the front side of power conversion system of conventional wind generation system and secondary side of consumer's power supply at distribution line. Measurements on power quality were performed and the effects of the wind generation system on distribution system were analyzed when it was and was not operated. The results show that 0.34[%] increase on voltage variation, 0.145 increase on current crest factor and 0.6[$^{\circ}$] deviation on phase difference when the power generation system was operated.

Design and Fabrication of a X-band Voltage Control Dielectric Resonator Oscillator with The Low Phase Noise (낮은 위상잡음을 갖는 X-band 전압제어 유전체 공진형 발진기의 설계 및 제작)

  • 박창현;최병하
    • Journal of the Institute of Electronics Engineers of Korea TC
    • /
    • v.41 no.5
    • /
    • pp.69-76
    • /
    • 2004
  • In this paper, a VCDRO (Voltage Control Dielectric Resonator Oscillator) with low phase noise for X-band application has been designed and fabricated. A low noise and low flicker noise MESFET and a high Q dielectric resonator were selected to obtain good phase noise Performance. Also, a varactor diode having high Q, qualify factor was used to reduce the loading effects and a big Gamma of diode was chosen for linearity of frequency over voltage tuning range. The fabricated circuits was simulated with circuit design tools, ADS to provide the optimum performances. As the measured results of fabricated oscillator, the output power was 5.8 ㏈m at center frequency 12.05㎓ and harmonic suppression -30㏈c, phase noise -114 ㏈c at 100 KHz offset frequency, respectively, and the frequency tuning range as the function of valtage applied to varactor diode was 15.2 MHz and its power variation with frequency was 0.2 ㏈. This oscillator could be available to a local oscillator in X-band.

Fully Differential 5-GHz LC-Tank VCOs with Improved Phase Noise and Wide Tuning Range

  • Lee, Ja-Yol;Park, Chan-Woo;Lee, Sang-Heung;Kang, Jin-Young;Oh, Seung-Hyeub
    • ETRI Journal
    • /
    • v.27 no.5
    • /
    • pp.473-483
    • /
    • 2005
  • In this paper, we propose two LC voltage-controlled oscillators (VCOs) that improve both phase noise and tuning range. With both 1/f induced low-frequency noise and low-frequency thermal noise around DC or around harmonics suppressed significantly by the employment of a current-current negative feedback (CCNF) loop, the phase noise in the CCNF LC VCO has been improved by about 10 dB at 6 MHz offset compared to the conventional LC VCO. The phase noise of the CCNF VCO was measured as -112 dBc/Hz at 6 MHz offset from 5.5 GHz carrier frequency. Also, we present a bandwidth-enhanced LC VCO whose tuning range has been increased about 250 % by connecting the varactor to the bases of the cross-coupled pair. The phase noise of the bandwidth-enhanced LC-tank VCO has been improved by about 6 dB at 6 MHz offset compared to the conventional LC VCO. The phase noise reduction has been achieved because the DC-decoupling capacitor Cc prevents the output common-mode level from modulating the varactor bias point, and the signal power increases in the LC-tank resonator. The bandwidth-enhanced LC VCO represents a 12 % bandwidth and phase noise of -108 dBc/Hz at 6 MHz offset.

  • PDF

Development of a Chaotic Electric Arc Furnace Model (전력 품질 해석을 위한 개선된 전기아크로 모델 개발)

  • Jang, Gil-Soo;Wang, Weiguo;Lee, Byong-Jun;Kwon, Sae-Hyuk
    • Proceedings of the KIEE Conference
    • /
    • 2000.07a
    • /
    • pp.55-57
    • /
    • 2000
  • 대규모의 전력을 사용하며 전력 수요가 일정하지 않고 변동하는 제철소의 전기아크로 (electric arc furnace) 부하는 전압 플릭커 (voltage flicker) 등 전력품질을 저하시키는 현상의 주 원인이 되고 있다. 따라서, 전력품질의 향상을 위한 전력계통의 계획과 운용에 있어서 이러한 부하들의 비선형적인 전압-전류 특성을 해석하고 모델링하는 것이 우선 되어야 한다. 특히 전기아크로 부하의 비선형적이고 랜덤 신호에 가까운 특성은 stochastic 접근법에 의해 주로 모델링되어 왔으나, 전기아크로 부하에 의한 전력계통에서의 영향을 평가를 위해서는 deterministic 접근법에 의한 모델링이 필요하며 전기아크로 부하가 가지는 chaos 특성을 Lorenz 시스템으로 표현한 부하모델이 개발되었다[1]. 개발된 모델에 의해 하나의 chaos 시스템으로 예측된 전기아크로 부하 패턴은 전 동작 범위에서 부하 특성을 정확하게 반영하는데 문제가 있다. 따라서, 전기아크로 부하 패턴을 표현할 수 있는 복수의 chaos 시스템을 이용하여 보다 나은 예측 특성을 가진 부하 모델의 개발이 필요하다. 본 논문에서는 기존의 Lorenz 시스템과 전기아크로 부하의 고주파영역 특성을 보다 적절하게 반영할 수 있는 Logistic 시스템을 혼합한 형태의 chaos 모델을 개발하고, 전력 계통에서의 전력품질 저하현상을 정량화하는 지수를 통해 모델의 유용성과 정확성을 검증하고자 한다.

  • PDF

LNA with Chopper Stabilization Technique Using Sample and Hold Circuit (샘플 홀드 회로를 이용한 초퍼 안정화 기법이 적용된 저잡음 증폭기)

  • Park, Youngmin;Nam, Minho;Cho, Kyoungrok
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.53 no.10
    • /
    • pp.27-33
    • /
    • 2016
  • This paper proposes a Low Noise Amplifier (LNA) with chopper stabilization technique with a sample-hold circuit. Chopper stabilization technique is effective in terms of reducing low frequency offset and flicker noise. Conventional chopper amplifier has a disadvantage in area because of using Low Pass Filter (LPF) for remove chopping spike. The proposed chopper amplifier employed sample and hold technique to decrease chopping spike instead of LPF that improves 36% in voltage damping and 11% in area.

Development of a Mixed Chaotic Electric Arc Furnace Model (전력 품질 해석을 위한 개선된 전기아크로 모델 개발)

  • Jang, Gil-Soo;Wang, Weiguo;Lee, Byongjun;Kwon, Sae-Hyuk
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.50 no.2
    • /
    • pp.90-95
    • /
    • 2001
  • Electric arc furnaces (EAFs) has a process to cause the degradation of the electric power quality such as voltage flicker. In order to adequately understand and analyze the effects on the power system from these loads, obtaining an accurate representation of the characteristics of the loads is crucial. In this paper, a mixed chaotic EAF model to represent the low frequency and high frequency variations of the arc current respectively has been proposed. The Lorenz system may contribute to the low frequency components of arc current and the logistic equation may contribute to the high frequency components, and the proposed mixed model will be a combination of both Lorenz and logistic model. The concept of chaotic parameters, such as chaotic resistance, inductance of admittance has been also proposed for the characterization of arc furnace operation and the highly nonlinear physical processes. The power quality indices are calculated from the simulated waveforms and compared with the actual power quality indices statistics in order to illustrate the model's capabilities.

  • PDF