• 제목/요약/키워드: voltage flicker

검색결과 100건 처리시간 0.034초

LED에 의한 무대조명의 조도제어 시스템 (Dimming control system of stage lighting by using LED)

  • 박종연;이규민
    • 산업기술연구
    • /
    • 제30권B호
    • /
    • pp.109-112
    • /
    • 2010
  • Unlike the general lighting systems, stage lighting system requires accurate dimming control and reduction of flicker phenomenon. In this paper, we studied PWM dimming control and linear voltage level control methods. PWM Dimming is easy control and flicker phenomenon of linear voltage level dimming does not happen by experiment result. We concluded that stage lighting dimming system required to combine two techniques of the PWM and linear voltage level dimming control method.

  • PDF

Improvement in Computation of Δ V10 Flicker Severity Index Using Intelligent Methods

  • Moallem, Payman;Zargari, Abolfazl;Kiyoumarsi, Arash
    • Journal of Power Electronics
    • /
    • 제11권2호
    • /
    • pp.228-236
    • /
    • 2011
  • The ${\Delta}\;V_{10}$ or 10-Hz flicker index, as a common method of measurement of voltage flicker severity in power systems, requires a high computational cost and a large amount of memory. In this paper, for measuring the ${\Delta}\;V_{10}$ index, a new method based on the Adaline (adaptive linear neuron) system, the FFT (fast Fourier transform), and the PSO (particle swarm optimization) algorithm is proposed. In this method, for reducing the sampling frequency, calculations are carried out on the envelope of a power system voltage that contains a flicker component. Extracting the envelope of the voltage is implemented by the Adaline system. In addition, in order to increase the accuracy in computing the flicker components, the PSO algorithm is used for reducing the spectral leakage error in the FFT calculations. Therefore, the proposed method has a lower computational cost in FFT computation due to the use of a smaller sampling window. It also requires less memory since it uses the envelope of the power system voltage. Moreover, it shows more accuracy because the PSO algorithm is used in the determination of the flicker frequency and the corresponding amplitude. The sensitivity of the proposed method with respect to the main frequency drift is very low. The proposed algorithm is evaluated by simulations. The validity of the simulations is proven by the implementation of the algorithm with an ARM microcontroller-based digital system. Finally, its function is evaluated with real-time measurements.

Matlab/Simulink를 이용한 무효전력 보상장치의 플리커 저감 효과 연구 (Comparative Simulation of flicker Mitigating Efficiencies of Various Compensating Devices using Matlab/Simulink)

  • 정재안;조수환;장길수;강문호
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2008년도 제39회 하계학술대회
    • /
    • pp.83-84
    • /
    • 2008
  • Voltage fluctuation, also known as flicker, is a power quality problem caused by nonlinear loads like electric arc furnace. Since it is interpreted as a variation of the supplied electrical energy, it causes the residential customers to feel much annoyed visually through the lamps. Due to the statistical nature of IEC (International Electrotechnical Commission) short-term flicker severity index, Pst, it is not feasible to pre-evaluate the flicker level using the transient power system simulators such as Sim Power System in Matlab/Simulink. So this paper presents not only how to design the Matlab/Simulink IEC flickermeter to yield the Pst value, which considering electric distribution environments of South Korea, but also how to mitigate the voltage flicker at the Point of Common Coupling (PCC). In order to achieve this, the flicker mitigation efficiencies of various compensating devices, such as Static Var Compensator (SVC), STATCOM will be applied and compared. The simulated result demonstrates which compensating equipment is the most efficient method to mitigate the flicker phenomenon.

  • PDF

전기로 부하에서 SVC의 플리커 효과에 관한 연구 (A Study on the Fliker Effect of SVC in Electric Arc Furnace Loads)

  • 김경철;진성은;이일무
    • 조명전기설비학회논문지
    • /
    • 제20권8호
    • /
    • pp.48-53
    • /
    • 2006
  • 제철소에서 사용되고 있는 전기로는 전력계통에 전압 변동을 일으키며 시간에 따라 변하는 비선형 부하이다. 플리커는 전압 변동의 크기에 따라 램프의 방출 변화에 의한 인간의 지각 효과로 정의된다. 플리커 레벨은 전압 변동의 크기, 주파수 및 기간에 의해 결정된다. 본 논문에서는 전기로 부하로 인한 154[kV] 시스템에서의 전압 변동 문제를 측정하고, 플리커 저감을 위한 SVC 적용 결과를 분석하고, IEC 61000-3-7에 의하여 플리커를 평가하였다.

계통연계 풍력발전 시스템의 플리커 지수 계산방법 (A Method to Calculate Flicker Emission of a Grid-Connected Wind Turbine System)

  • 안덕근;노경수
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2002년도 하계학술대회 논문집 A
    • /
    • pp.310-312
    • /
    • 2002
  • The development of IEC 61400-21 provides firm basis for assessment of the impact of wind turbines on voltage quality. This paper presents analysis and modeling of the flicker emission of wind turbines. The paper concentrates on the theoretical aspects of the flicker algorithm, wind turbine characteristics and the generation of flicker during continuous operation of wind turbines. It also introduces a simplified assessment to limit the flicker emission.

  • PDF

철도차량용 보조전원장치에 관한 연구 (The Study of Auxiliary Power Unit for locomotive)

  • 하인용;이원철;이상석;김태환;원충연
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2009년도 춘계학술대회 논문집 특별세미나,특별/일반세션
    • /
    • pp.615-619
    • /
    • 2009
  • There are many increasing demands for efficient high power density of auxiliary power unit(APU) for high speed traction application. Many techniques have been proposed to measure the voltage flicker on the traditional pulse width modulation(PWM) inverter. This paper proposes a novel functionality of the static inverter on the APU to mitigate the voltage flicker and regulate the output voltage. A new control algorithm for the inverter based on the Hilbert transform(HT) is presented. The HT is employed as an effective technique for tracking the voltage flicker levels in APU systems. Simulation results are provided to verify the tracking capabilities of the HT and to evaluate the performance of the proposed DG interface for multi-function operation.

  • PDF

Matlab/Simulink 기반의 IEC 플리커미터를 이용한 플리커 저감효과 모의에 대한 연구 (Analysis of Flicker Mitigation Effects using IEC Digital Flickermeter based on Matlab/Simulink Simulation)

  • 정재안;조수환;권세혁;장길수;강문호
    • 전기학회논문지
    • /
    • 제58권2호
    • /
    • pp.232-238
    • /
    • 2009
  • Flicker, also known as voltage fluctuation, is a newest problem of power quality issues, because it is caused by nonlinear loads such as electrical arc furnace and large-scale induction motor, which are country-widely used as the heavy industries of a country develop. An international standard, International Electrotechnical Commission (IEC) 61000-4-15, was published in 1997 and revised in 2003. With increasing concerns about flicker, its mitigation methods have been also studied. General countermeasures for flicker are divided into three categories: a) enhancing the capacity of supplying system, b) Series elements including series reactor and series capacitor and c) power electronic devices including static VAR compensator (SVC) and static synchronous compensator (STATCOM). This paper introduces how to mitigate the voltage flicker at the point of common coupling (PCC) and presents how to simulate and compare the flicker alleviating effects by each mitigation method, using IEC flickermeter based on the Matlab/Simulink program.

상호고조파에 의한 플리커의 측정에 가능한 IEC 플리커미터의 설계 (Modification of IEC Flickermeter to Measure the Flicker Caused by Inter-Harmonics)

  • 조수환;정재안;장길수;권세혁
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2007년도 제38회 하계학술대회
    • /
    • pp.69-70
    • /
    • 2007
  • Now the IEC flicker measuring algorithms and its flicker index of $P_{st}$ and $P_{lt}$ are accepted internationally as standards. But it is recently found that IEC flickermeter has a main drawback that it cannot afford to detect the fluctuating patterns of voltage envelope caused by interharmonics higher than 102Hz in the 60Hz power system. This is brought about by two components of IEC flicker measuring steps, squaring and low-pass filtering. This paper presents the innate defect of IEC flickermeter and proposes a modified measuring method considering the voltage flickers by subharmonics and interharmonics.

  • PDF

전압플리커 저감과 역률 보상 기능을 갖는 배전용 STATCOM의 실계통연계 운전결과 분석 (Analysis of the Distribution STATCOM for Improving the power factor and Mitigation of Voltage Flicker in Real System)

  • 오관일;전영수;박상태;추진부
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2000년도 하계학술대회 논문집 A
    • /
    • pp.245-248
    • /
    • 2000
  • This paper presents the test and operation results of the domestic demonstration of the reactive power compensation device called STATCOM (STATic COMpensator). The object of the paper is to describe the reliability of the unit based on the extensive operation databases. By controlling reactive power, the technology offers utilities the opportunity for increased efficiency and their capabilities will permit transmission planners make the best use of their existing transmission resources STATCOM is a custom power device in a way and can be used in a similar way for the dynamic compensation of power transmission systems, mitigation of voltage flicker and improving the power factor. It is shown that the STATCOM has clear advantages in areas such as: mitigation of voltage flicker and improving power factor.

  • PDF

전기설비의 플리커 저감을 위한 TCR 시뮬레이션 (TCR simulation for flicker suppression of electrical equipment)

  • 이홍기;강창섭;윤철섭;손재현
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1998년도 하계학술대회 논문집 B
    • /
    • pp.763-765
    • /
    • 1998
  • Flicker embrace all diverse effects of rapid voltage fluctuation. To minimize these effects, the voltage fluctuation must be kept below the limit. The aim of this study is to simulate TCR for flicker suppression. To do this, we built models similar to electrical systems of fields using EMTP and attached TCR to them. After attaching TCR, we confirmed reduction of incoming voltage fluctuation and reactive power compensation.

  • PDF