Fabrication and Characteristics of Ring-Dot type Piezoelectric Transformer (Ring-dot형 감압형 압전변환기의 제작과 특성)

  • Nam, Sung-Jin;Lee, Yeung-Min;Nam, Hyo-Duk;Sohn, Joon-Ho;Lee, Joon-Hyung
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2004.07b
    • /
    • pp.722-725
    • /
    • 2004
  • Voltage step-down characteristics in Ring/Dot type piezoelectric transformer were examined as a function of the area of input electrode when the area of output electrode is fixed. The effects of driving frequency and load resistance on the voltage step-down characteristics were also examined. Voltage gain was greatly dependent on the driving frequency and load resistance, and showed a maximum gain at resonance frequency of the step-down transformer. The frequency where the maximum output voltage appears increased about 0.2% as the load resistance increased from 10 to $150\Omega$. As the area of input electrode increased, the voltage gain and the efficiency of the transformer increased. Frequency dependence of efficiency of the step-down transformer revealed a similar tendency with the voltage gain curves. The maximum efficiency remarked 94% when the input voltage and the load resistance were 20 $V_{PP}$ and $120\Omega$, respectively.

  • PDF

The Design and Performance Test of Mold Transformer for Outdoor Pole (50 kVA 주상용 몰드변압기의 설계 및 특성평가)

  • Cho, Han-Goo;Lee, Un-Yong;HwangBo, Kuk
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2002.05c
    • /
    • pp.132-137
    • /
    • 2002
  • The mold transformers have been widely used in underground substations in large building and have some advantages in comparison to oil-transformer, that is low fire risk, excellent environmental compatibility, compact size and high reliability. In addition, the application of mold transformer for outdoor is possible due to development of epoxy resin. The mold transformer generally has cooling duct between low voltage coil and high voltage coil. A mold transformer made by one body molding method has been developed for small size and low loss. The life of transformer is significantly dependent on the thermal behavior in windings. To analyse winding temperature rise, many transformer designer have calculated temperature distribution and hot spot point by finite element method(FEM). Recently, numerical analyses of transformer are studied for optimum design, that is electric field analysis, magnetic field, potential vibration, thermal distribution and thermal stress. In this paper, the temperature distribution of 50 kVA pole mold transformer for power distribution are investigated by FEM program and the temperature rise test of designed mold transformer carried out and test result is analyzed compare to simulation data. In this result, the designed mold transformer is satisfied to limit value of temperature and the other property is good such as voltage ratio, winding resistance, no-load loss, load loss, impedance voltage and percent regulation.

  • PDF

Magnetic Flux Saturation Analysis of Matching Transformer Considering Characteristic of Dynamic Voltage Restorer(DVR) (DVR의 특성을 고려한 매칭변압기의 자속포화 해석)

  • Shon, Jin-Geun;Kim, Dong-Joon;Kang, Min-Gu;Jeon, Hee-Jong
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.57 no.3
    • /
    • pp.236-243
    • /
    • 2008
  • This paper analyses magnetic flux saturation of matching transformer considering characteristic of dynamic voltage restorer(DVR) system to solve voltage sags which are considered the dominant disturbances affecting power quality. This DVR consist of PWM inverter to inject arbitrary voltage, LC low pass filter and matching transformer for isolation and grid connection. However, the matching transformer has an excess of inrush current by magnetic flux saturation in the core of transformer. Due to this inrush current, the rating of matching transformers is double for needed nominal rating for protection of DVR. Therefore, in this paper, an advanced modeling method of magnetic flux saturation is used to analyze a magnitude and characteristic of magnetizing current. Simulation and experimental results considering characteristic of DVR system are provided to demonstrate the validity of the proposed analysis method.

Flux Saturation Modeling of Matching Transformer for Dynamic Voltage Restore (동적전압보상기를 구성하기 위한 정합변압기의 자속포화현상 모델링)

  • Kim Wang-Rae;Kang Ho-Hyun;Jeon Hee-Jong;Han Woon-Dong;Oh Joong-Min
    • Proceedings of the KIPE Conference
    • /
    • 2006.06a
    • /
    • pp.428-431
    • /
    • 2006
  • Matching transformer in Dynamic Voltage Compensator is needed for grid connection and isolation. Flux saturation in transformer will be occurred by voltage of transformer from inverter and DC offset voltage and flux saturation makes over current in transformer. In this paper, mathematical modeling of matching transformer is proposed for flux saturation simulation of Dynamic Voltage Compensator.

  • PDF

Electric power characteristic test of diagnostic X-ray high voltage transformer by input power condition (고전압트랜스포머의 진공이 방사선출력 노이즈에 미치는 영향)

  • Kim, Young-Pyo;Cheon, Min-Woo;Park, Young-Pil
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2008.06a
    • /
    • pp.499-499
    • /
    • 2008
  • High voltage transformer of Diagnostic X-ray system has been contributed to wiping out disease to get a good quality images from patients. High voltage transformer of diagnostic X-ray system has been usefully used for diagnostic purpose but if high voltage transformer performances are deteriorated, low quality image will be archived. In this case, operator has to exposure to get a more good quality images. In this case, unexpected radiation could be exposed to patient and it is very harmful to the patient. And I would like to design and make equipment to checkable high voltage transformer performance after that I wish to test and study what it is most influences in radiation output quality.

  • PDF

Copper Particle Effect on the Breakdown Strength of Insulating Oil at Combined AC and DC Voltage

  • Wang, You-Yuan;Li, Yuan-Long;Wei, Chao;Zhang, Jing;Li, Xi
    • Journal of Electrical Engineering and Technology
    • /
    • v.12 no.2
    • /
    • pp.865-873
    • /
    • 2017
  • Converter transformer is the key equipment of high voltage direct current transmission system. The solid suspending particles originating from the process of installation and operation of converter transformer have significant influence on the insulation performance of transformer oil, especially in presence of DC component in applied voltage. Under high electric field, the particles easily lead to partial discharge and breakdown of insulating oil. This paper investigated copper particle effect on the breakdown voltage of transformer oil at combined AC and DC voltage. A simulation model with single copper particle was established to interpret the particle effect on the breakdown strength of insulating oil. The experimental and simulation results showed that the particles distort the electric field. The breakdown voltage of insulating oil contaminated with copper particle decreases with the increase of particle number, and the breakdown voltage and the logarithm of particle number approximately satisfy the linear relationship. With the increase of the DC component in applied voltage, the breakdown voltage of contaminated insulating oil decreases. The simulation results show that the particle collides with the electrode more frequently with more DC component contained in the applied voltage, which will trigger more discharge and decrease the breakdown voltage of insulating oil.

Investigation and Mitigation of Overvoltage Due to Ferroresonance in the Distribution Network

  • Sakarung, Preecha;Bunyagul, Teratam;Chatratana, Somchai
    • Journal of Electrical Engineering and Technology
    • /
    • v.2 no.3
    • /
    • pp.300-305
    • /
    • 2007
  • This paper reports an investigation of overvoltages caused by ferroresonance in the distribution system, which consists of a bank of open-delta single-phase voltage transformers. The high voltage sides of the voltage transformer are connected to the distribution system via three single-phase fuse cutouts. Due to the saturation characteristic of the transformer cores, ferroresonance can occur in the condition that the transformer is energized or deenergized with single-phase switching operation of the fuse cutouts. The simulation tool based on EMTP is used to investigate the overvoltages at the high side of voltage transformer. Bifurcation diagrams are used to present the ferroresonance behavior in ranges of different operating conditions. The simulation results are in good agreement with the results from the experiment of 22 kV voltage transformers. The mitigation technique with additional damping resistors in the secondary windings of the voltage transformers will be introduced. Brief discussion will be made on the physical phenomena related to the overvoltage and the damage of voltage transformer.

Help of Microcontroller on Voltage Control to Reduce Transformer Inrush Current

  • Fard, Ali Asghar Fathollahi
    • Transactions on Electrical and Electronic Materials
    • /
    • v.15 no.1
    • /
    • pp.12-15
    • /
    • 2014
  • At the moment of transformer energization by the supply voltage, a high current called transient inrush current, which may rise to ten times the transformer full load current, could be drawn by the primary winding. This paper discusses a microcontroller circuit with the intention of controlling and limiting the inrush current for a transformer, by the method of ramping up the supply voltage feeding to the transformer primary. Simulations and the experimental results show a significant reduction of inrush current, when the ramping up voltage is applied to the three-phase transformer load. The inrush current could be almost eliminated if the correct switching step rate is chosen.

External Resonant Ignitior for HID Lamps by Using the Transformer (변압기를 이용한 외장형 HID 램프용 공진형 이그니터)

  • Lee, Woo-Cheol
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.28 no.11
    • /
    • pp.9-16
    • /
    • 2014
  • The electronic ballast for HID lamps needs high ignition voltage which is consisted of high voltage pulse ignitor. However, In the case of street lamp it is far from a lamp to a ballast, the conventional pulsed high voltage ignitor can not turn on the HID lamps because of reduction of ignition voltage. Therefore, it needs to do the research on a resonant ignition to turn on the HID lamps. However, the resonant circuit which is consisted of LC occurs over current, so the capacity of the ignitor increases. The capacity of the ignitor can be reduced by using the transformer. In this case, the capacitor for resonance is installed to the secondary of the transformer, and the capacitor needs high withstanding voltage. Therefore, it needs to do the research on a resonant ignition to reduce the voltage over the resonant capacitor by dividing the secondary of the transformer.

Characteristics of Step-Down Transformer in PZT Piezoelectric Ceramics (PZT계 압전 세라믹 변압기의 감압특성)

  • 김오수;이준형;손정호;남효덕;조상희
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.14 no.11
    • /
    • pp.885-891
    • /
    • 2001
  • Ring/dot-type step-down piezoelectric transformer was manufactured by using Pb[(Mn$\sub$1/3/Sb$\sub$2/3)$\sub$0.05/Zr$\sub$0.475/Ti$\sub$0.475/]O$_3$ ceramics, which have excellent high-power piezoelectric properties. The characteristics of step-down piezoelectric transformer as a function of load resistance at output terminal was examined. Voltage gain was greatly dependent on drive frequency and load resistance, and showed maximum voltage gain at the resonance frequency. The output voltage was linearly increased as the input voltage increased. Voltage gain of the step-down piezoelectric transformer with respect to input voltage was very stable when the load resistance was in the range of 50-500 $\Omega$ .

  • PDF