• Title/Summary/Keyword: vital signs

검색결과 550건 처리시간 0.029초

음악요법 유형이 척추마취 수술환자의 수술 중 불안 및 활력징후에 미치는 영향 (Effects of Types of Music in Music Therapy on Anxiety and Vital signs of Surgical Patients Undergoing Operation Using Spinal Anesthesia)

  • 김연옥;김주현
    • Journal of Korean Biological Nursing Science
    • /
    • 제13권2호
    • /
    • pp.149-155
    • /
    • 2011
  • Purpose: The purpose of this research is to examine types of music (relax music or preferred music that patients have chosen) can effects on anxiety, blood pressure and pulse, and whether there are differences depending on the kinds of music in order to reduce anxiety of surgical patients using spinal anesthesia. Methods: This research's design is quasi-experimental design and non-equivalent control group pretest-posttest experimental design conducted on 60 surgical patients(experimental group 1=relax music therapy group, experimental group 2=preferred music therapy group, and group 3=control group) using spinal anesthesia. The Variables were trait anxiety, state anxiety, blood pressure, and pulse. Results: 1) In the state anxiety, there was a significant difference among the experimental groups 1, group 2 and the control group. 2) There was a significant difference in systolic blood pressure among the experimental group 1, group 2, and the control group. 3) In pulse, no significant difference among the experimental group 1, group 2 and the control group was detected. Conclusion: Regardless of the types of music, music therapy is thought to be effective nursing mediation to mitigate the state anxiety of surgical patients undergoing spinal anesthesia.

효율적인 보행자의 EEG 신호 전송을 위한 드론기반 센서네트워크 시나리오 (Drone Based Sensor Network Scenario for the Efficient Pedestrian's EEG Signal Transmission)

  • 조준모
    • 한국전자통신학회논문지
    • /
    • 제11권9호
    • /
    • pp.923-928
    • /
    • 2016
  • 오늘날 사람들의 건강을 실시간으로 점검하고 응급상황에 대처하기 위해 다양한 기술들이 개발되어지고 있다. 지금까지는 대부분 맥박과 같은 생체신호를 측정하여 활용하고 있지만 최근에는 뇌파(EEG)를 활용하는 연구가 늘어나고 있다. 그러나 길에서 걸어 다니는 모든 사람들의 EEG 신호를 실시간으로 검출하여 해당 서버에 전송하는 것은 여러 가지 문제점을 야기시킨다. 특히, 2차원 공간에서 실시간으로 EEG 신호를 수집 및 전송하는 제약이 존재하기 때문에 본 논문에서는 이러한 제약을 피할 수 있는 3차원 공간의 드론을 활용하는 효율적인 네트워크 모델을 제안하고자 한다. 이러한 모델을 Opnet 시뮬레이터를 활용하여 네트워크 구조를 설계하고 시뮬레이션하고 평가하였다.

증식 치료와 근육내 자극술시의 수면 마취 (The Sedation Anesthesia for Prolotherapy and Intramuscular Stimulation)

  • 조대현;김명희;홍지희
    • The Korean Journal of Pain
    • /
    • 제19권1호
    • /
    • pp.77-80
    • /
    • 2006
  • Background: Painful experiences during procedures such as prolotherapy and intramuscular stimulation are stressful to patients and can affect the treatment outcome. We present a method for relieving pain and increasing the level of patient comfort during the procedure. Methods: Twenty six patients who requested sedation anesthesia during the procedure were examined. All patients were injected with 500 ml of 0.9% normal saline and were monitored by electrocardiography, blood pressure and pulse oximetry. The patients were supplied with oxygen (3 L/min) through a nasal cannula. Midazolam (0.02 mg/kg) and alfentanil ($8{\mu}g/kg$) was injected before the procedure and a bolus injection was administered during the procedure if patients felt any pain. The duration of the procedure, the total amount of drugs, the changes in the systolic blood pressure, heart rate, pulse oxygen saturation, sedation and pain level during procedure, satisfaction scale after the procedure, complications and the incidence of amnesia were evaluated. Results: Twenty one patients had a moderate level of sedation, 15 patients did not feel any pain during the procedure, 17 patients had high level of satisfaction (8-10). No patient experienced complications after the procedure, or unstable vital signs, and 6 patients could not remember the procedure. Conclusions: Sedation anesthesia is a safe method for relieving pain during the procedure, and most patients had a high level of satisfaction.

Development Brief of A Body Area Network for Ubiquitous Healthcare : An Introduction to Ubiquitous Biomedical Systems Development Center

  • Hong Joo-Hyun;Kim Nam-Jin;Cha Eun-Jong;Lee Tae-Soo
    • 대한의용생체공학회:의공학회지
    • /
    • 제26권5호
    • /
    • pp.331-335
    • /
    • 2005
  • The fusion technology of small sensor and wireless communication was followed by various application examples of the embedded system, where the social infrastructural facilities and ecological environment were wirelessly monitored. In addition, this technology represents the primary application area being extended into the healthcare field. In this study, a body area network for ubiquitous healthcare is presented. More specifically this represents a wireless biomedical signal acquisition device characterized by small size, low power consumption, pre-processing and archiving capability. Using this device, a new method for monitoring vital signs and activity is created. A PDA-based wireless sensor network enables patients to be monitored during their daily living, without any constraints. Therefore, the proposed method can be used to develop Activities of Daily Living (ADL) monitoring devices for the elderly or movement impaired people. A medical center would be able to remotely monitor the current state of elderly people and support first-aid in emergency cases. In addition, this method will reduce medical costs in society, where the average life expectancy is increasing.

Recurrent hemoptysis in a 26-year-old woman with a ground-glass opacity lesion of the lung

  • Kim, Jong Ha;Park, Sin-Youl
    • Journal of Yeungnam Medical Science
    • /
    • 제37권1호
    • /
    • pp.59-62
    • /
    • 2020
  • Hemoptysis is a major reason for emergency department (ED) visits. Catamenial hemoptysis (CH), a rare condition of thoracic endometriosis, can cause recurrent hemoptysis but is difficult to diagnose in the ED due to the scarcity of cases and nonspecific clinical findings. We report a case of a 26-year-old woman who presented to the ED with recurrent hemoptysis since 2 years without a definite cause. Her vital signs and blood test findings were unremarkable. Chest computed tomography (CT) did not show any specific lesions other than a non-specific ground-glass opacity pattern in her right lung. She was on day 4 of her menstrual cycle and her hemoptysis frequently occurred during menstruation. Although there was no histological confirmation, based on her history of hemoptysis during menstruation and no other cause of the hemoptysis, the patient was tentatively diagnosed with CH and was administered gonadotropin-releasing hormone. She had no recurrence of hemoptysis for 3 months. While CH is difficult to diagnose in the ED, the patient's recurrent hemoptysis related to menstruation was a clue to the presence of CH. Therefore, physicians should determine the relationship between hemoptysis and menstruation for women of childbearing age presenting with repeated hemoptysis without a definite cause.

성상신경절 차단 후 발생한 심한 경부혈종 -증례 보고- (Severe Hematoma in the Neck Following the Stellate Ganglion Block -A case report-)

  • 강형창;김유재
    • The Korean Journal of Pain
    • /
    • 제11권2호
    • /
    • pp.346-349
    • /
    • 1998
  • The technique of the stellate ganglion block is widely used as it is relatively simple and safe. But it can cause severe complications because there are major blood vessels and nerves around the stellate ganglion. We practiced CPR because of the respiratory failure caused by severe hematoma in the neck following the stellate ganglion block. A 46-year-old male patient admitted to ENT department because of the both sudden sensorineural hearing loss that happened after URI. He was referred to Pain Clinic for further evaluation and treatment. We decided to block the stellate ganglion. We injected 6ml of 0.5% mepivacaine on both sides of the stellate ganglion. There were no blood aspiration and abnormal vital signs during the 30 minute observation, either. Three hours after he went to the private room, he had pain and edema in his neck, but no respiratory defficulty. But later, respiratory failure was suddenly followed. So we practiced CPR. We confirmed severe hematomas in the neck through CT scanning. Hematomas is removed and the ruptured blood vessels which is supposed to be muscular branch of vertebral artery is ligated under general anesthesia. The patient was discharged from hospital after the treatment of pneumonia and duodenal ulcer as complications. We recommand you to compress the block site more than five minutes and not to prick with the needle several times at one point to prevent the formation of hematomas.

  • PDF

칼만 필터를 이용한 흉곽 임피던스법 기반의 호흡 신호 계측시스템 개발 (Development of Pneumography Impedance Based Respiration Measurement System Using Kalman Filter)

  • 남은혜;최창현;김용주;신동렬
    • Journal of Biosystems Engineering
    • /
    • 제33권5호
    • /
    • pp.326-332
    • /
    • 2008
  • A respiration measurement system for vital signs was developed. Respiration signals were measured, processed, and analyzed. Four electrodes, attached on the surface of the skin, were used to monitor respiration signals by impedance pneumography. The measured signals were amplified, detrended, filtered, and transferred toan embedded module. The Kalman filter was used to remove motion artifact from the respiration signals. Experiments were conducted at stable condition and walking condition to evaluate the performance of the system. Respiration rates of five males and five females were measured and analyzed at each condition. The referenced respiration signal was determined by temperature of nose surroundings. The results showed that the respiration rates at the walking condition had more motion artifacts than the stable condition. The accuracies of the respiration measurement system with Kalman filter were found as 96% at the stable condition and 95% at the walking condition. The results showed that the Kalman filter was an effective tool to remove the motion artifact from the respiration signal.

휴대용 불안 증후 측정기 개발에 관한 연구 (A study on an Ambulatory Monitoring of Vital Signs for Anxiety)

  • 윤형로;김광준
    • 대한의용생체공학회:의공학회지
    • /
    • 제12권4호
    • /
    • pp.235-242
    • /
    • 1991
  • This research has reported that the selection and assessment of treatment in anxiety disorders depend to a large extend on patient reports of somatic symptomatology. However, the correspondence between such reports and actual physiological data Is unknown as the physiological measures used were taken in laboratory. The purpose of the ambulatory momboring device is, therefore, to present for analysis physiological data derived from the sub jects during their daily activities. The physiological parameters of interest are heart rate, respiratory rate, skin conductance level/response, skin temperature, and activity level. This device had an microcomputer based data acquisition unit, Interfaced to it for the purpose of data collection. The data is collected usually over a period of 12 hours. The data from the ambulatory monitoring device can be used to assess the psychophysiology of anxiety in the field. The data from the device will also reveal if patients who report different sets of symptoms differ physiologically too. Thls will help physicians for the right kind of treatment and also solve the many uncertainties that have existed thus far in quantizing anxiety.

  • PDF

임베디드 리눅스 환경에서 RFID 기반의 Mobile Telemedicine System 구현 (Design of Mobile Telemedicine System using RFID based on Embedded Linux)

  • 윤찬영
    • 한국콘텐츠학회:학술대회논문집
    • /
    • 한국콘텐츠학회 2006년도 춘계 종합학술대회 논문집
    • /
    • pp.479-482
    • /
    • 2006
  • Mobile Telemedicine은 의료진과 환자간의 정보교환을 제공하기위한 일반적인 기술로 사용되어지고 있다. 또한 유비쿼터스 센서 네트워크의 기술을 활용하여 의료진은 원격지 환자의 다양한 생체데이터를 획득하고자 한다. 본 논문은 임베디드 리눅스 운영체제를 기반으로 Intel X-Hyper PXA255 ARM CPU를 이용하여 구현한 RFID 리더 시스템에서 RFID 리더에서 수신되어진 환자의 태그 정보를 무선 LAN을 통하여 인터넷에 연결되어진 병원의 MySQL서버에 전달하는 기능을 수행하는 RFID 리더 플랫폼의 설계 및 구현을 위한 것이다. 구현되어진 임베디드 리눅스 기반의 RFID 리더는 크게 RFID 모듈, ARM 프로세서, RS-232 인터페이스, 무선 LAN 등으로 구성되고, 제안된 논문은 RFID의 개념 및 리더의 동작원리를 소개하고 임베디드 리눅스기반에서 QT 및 MySQL을 사용하여 구현되어진 리더플랫폼을 제안하고 구현한다.

  • PDF

휴대용 무선 응급 단말기 및 통합 시스템 개발 (Development of Portable Wireless Emergency Units and Integrated System)

  • 송미혜;명현석;이경중
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2006년도 제37회 하계학술대회 논문집 D
    • /
    • pp.2161-2162
    • /
    • 2006
  • In this study, we developed five mobile units and an integrated system which can manage vital signs from each unit using Bluetooth wireless communication. The five kinds of mobile unit were so designed that each has different function to be applied according to the condition of patient properly. The mobile units can measure ECG signal of single or 12 channel, blood pressure, pulse and SpO2 signal from a patient. Also, to reduce the uncomfortable measurement, several types of units such as belt type, wrist type and necklace type were designed. Our proposed system can integrate and monitor several biological signals from different patient by using Bluetooth wireless communication simultaneously. The developed system was evaluated in the simulated emergent situation and showed the system can monitor 5 patients in maximum according to the data quality. It showed the possibilities that the developed system can be used effectively for emergency situation or in- or out-hospital transport of patient. In future, with the combination of mobile communication technique, a patient who is in emergency situation can be provided with proper first-aid and a doctor can pile information of patient and give better diagnosis and treatments.

  • PDF