• Title/Summary/Keyword: visual system calibration

Search Result 78, Processing Time 0.022 seconds

Detection of Calibration Patterns for Camera Calibration with Irregular Lighting and Complicated Backgrounds

  • Kang, Dong-Joong;Ha, Jong-Eun;Jeong, Mun-Ho
    • International Journal of Control, Automation, and Systems
    • /
    • v.6 no.5
    • /
    • pp.746-754
    • /
    • 2008
  • This paper proposes a method to detect calibration patterns for accurate camera calibration under complicated backgrounds and uneven lighting conditions of industrial fields. Required to measure object dimensions, the preprocessing of camera calibration must be able to extract calibration points from a calibration pattern. However, industrial fields for visual inspection rarely provide the proper lighting conditions for camera calibration of a measurement system. In this paper, a probabilistic criterion is proposed to detect a local set of calibration points, which would guide the extraction of other calibration points in a cluttered background under irregular lighting conditions. If only a local part of the calibration pattern can be seen, input data can be extracted for camera calibration. In an experiment using real images, we verified that the method can be applied to camera calibration for poor quality images obtained under uneven illumination and cluttered background.

Calibration off multiple-sensor measuring system for efficient visual inspection (형상 검사를 위한 multiple-sensor 측정 시스템의 캘리브레이션 연구)

  • 김승만;손석배;이관행
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2002.05a
    • /
    • pp.579-582
    • /
    • 2002
  • In acquiring the surface information of a part, two types of measuring machines have been used: contact type and non-contact type. Since each measuring device has the pres and cons, an integrated measuring system is proposed to acquire the optimal point data. In order to implement the integrated measuring system, the relationship of coordinate systems between each measuring device should be established. In this paper, a new datum fixture and a calibration method for the multiple-sensor measuring system are proposed. The datum fixture is designed to interface two machines, a CMM and a laser scanner. The position of the datum fixture is calibrated by the axis information off motorized rotation stage which is used for a part setup.

  • PDF

A development of the simple camera calibration system using the grid type frame with different line widths (다른 선폭들로 구성된 격자형 교정판을 이용한 간단한 카메라 교정 시스템의 개발)

  • 정준익;최성구;노도환
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1997.10a
    • /
    • pp.371-374
    • /
    • 1997
  • Recently, the development of computer achieves a system which is similar to the mechanics of human visual system. The 3-dimensional measurement using monocular vision system must be achieved a camera calibration. So far, the camera calibration technique required reference target in a scene. But, these methods are inefficient because they have many calculation procedures and difficulties in analysis. Therefore, this paper proposes a native method that without reference target in a scene. We use the grid type frame with different line widths. This method uses vanishing point concept that possess a rotation parameter of the camera and perspective ration that perspect each line widths into a image. We confirmed accuracy of calibration parameter estimation through experiment on the algorithm with a grid paper with different line widths.

  • PDF

Development of a Robot's Visual System for Measuring Distance and Width of Object Algorism (로봇의 시각시스템을 위한 물체의 거리 및 크기측정 알고리즘 개발)

  • Kim, Hoi-In;Kim, Gab-Soon
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.17 no.2
    • /
    • pp.88-92
    • /
    • 2011
  • This paper looks at the development of the visual system of robots, and the development of image processing algorism to measure the size of an object and the distance from robot to an object for the visual system. Robots usually get the visual systems with a camera for measuring the size of an object and the distance to an object. The visual systems are accurately impossible the size and distance in case of that the locations of the systems is changed and the objects are not on the ground. Thus, in this paper, we developed robot's visual system to measure the size of an object and the distance to an object using two cameras and two-degree robot mechanism. And, we developed the image processing algorism to measure the size of an object and the distance from robot to an object for the visual system, and finally, carried out the characteristics test of the developed visual system. As a result, it is thought that the developed system could accurately measure the size of an object and the distance to an object.

A Study on the Camera Calibration Algorithm using the Grid Type Frame with Different Line Widths (다른 선폭들로 구성된 격자형 교정판을 이용한 카메라 교정 알고리즘에 관한 연구)

  • Jeong, Jun-Ik;Han, Young-Bae;Rho, Do-Hwan
    • Proceedings of the KIEE Conference
    • /
    • 1998.07g
    • /
    • pp.2333-2335
    • /
    • 1998
  • Recently, the development of computer achieves a system which is similar to the mechanics of human visual system. The 3D measurement using monocular vision system must be achieved a camera calibration. So far, the camera calibration technique required reference target in a scene. But, these methods are inefficient because they have many calculation procedures and difficulties in analysis. Therefore, this paper proposes a native method that without reference target in a scene. We use the grid type frame with different line widths. This method uses vanishing point concept that possess a rotation parameter of the camera and perspective ration that perfect each line widths into a image. We confirmed accuracy of calibration parameter estimation through experiment on the algorithm with a grid paper with different line widths.

  • PDF

Automation of Primary Vibration Calibration System Using Laser Interferometer (레이저 간섭계를 이용한 진동 가속도계 절대교정 시스템 자동화)

  • Cho, Seung-Il;Lee, Yong-Bong;Jeon, Byeong-Su;Lee, Jong-Kyu;Lee, Doo-Hee
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.15 no.11 s.104
    • /
    • pp.1241-1247
    • /
    • 2005
  • An automation of primary vibration calibration system was developed and tested. Using GPIB interface, the console PC make the control of equipments, signal collecting and save measuring results automatically by the instructions in the program by Visual Basic. Several trials of automatic calibration for the accelerometer(ENDEVCO 2270) using this developed system give the reliable results.

Viewing Angle-Improved 3D Integral Imaging Display with Eye Tracking Sensor

  • Hong, Seokmin;Shin, Donghak;Lee, Joon-Jae;Lee, Byung-Gook
    • Journal of information and communication convergence engineering
    • /
    • v.12 no.4
    • /
    • pp.208-214
    • /
    • 2014
  • In this paper, in order to solve the problems of a narrow viewing angle and the flip effect in a three-dimensional (3D) integral imaging display, we propose an improved system by using an eye tracking method based on the Kinect sensor. In the proposed method, we introduce two types of calibration processes. First process is to perform the calibration between two cameras within Kinect sensor to collect specific 3D information. Second process is to use a space calibration for the coordinate conversion between the Kinect sensor and the coordinate system of the display panel. Our calibration processes can provide the improved performance of estimation for 3D position of the observer's eyes and generate elemental images in real-time speed based on the estimated position. To show the usefulness of the proposed method, we implement an integral imaging display system using the eye tracking process based on our calibration processes and carry out the preliminary experiments by measuring the viewing angle and flipping effect for the reconstructed 3D images. The experimental results reveal that the proposed method extended the viewing angles and removed the flipping images compared with the conventional system.

A Study on Visual Servoing Application for Robot OLP Compensation (로봇 OLP 보상을 위한 시각 서보잉 응용에 관한 연구)

  • 김진대;신찬배;이재원
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.21 no.4
    • /
    • pp.95-102
    • /
    • 2004
  • It is necessary to improve the exactness and adaptation of the working environment in the intelligent robot system. The vision sensor have been studied for this reason fur a long time. However, it is very difficult to perform the camera and robot calibrations because the three dimensional reconstruction and many processes are required for the real usages. This paper suggests the image based visual servoing to solve the problem of old calibration technique and supports OLP(Off-Line-Programming) path compensation. Virtual camera can be modeled from the real factors and virtual images obtained from virtual camera gives more easy perception process. Also, Initial path generated from OLP could be compensated by the pixel level acquired from the real and virtual, respectively. Consequently, the proposed visually assisted OLP teaching remove the calibration and reconstruction process in real working space. With a virtual simulation, the better performance is observed and the robot path error is calibrated by the image differences.

A Camera Calibration Method using Several Images for Three Dimensional Measurement (여러 장의 영상을 사용하는 3차원 계측용 카메라 교정방법)

  • Kang, Dong-Joong
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.13 no.3
    • /
    • pp.224-229
    • /
    • 2007
  • This paper presents a camera calibration method using several images for three dimensional measurement applications such as stereo systems, mobile robots, and visual inspection systems in factories. Conventional calibration methods that use single image suffer from errors related to reference point extraction in image, lens distortion, and numerical analysis of nonlinear optimization. The camera parameter values obtained from images of same camera is not same even though we use same calibration method. The camera parameters that are obtained from several images of different view for a calibration target is usaully not same with large error values and we can not assume a special probabilistic distribution when we estimate the parameter values. In this paper, the median value of camera parameters from several images is used to improve estimation of the camera values in an iterative step with nonlinear optimization. The proposed method is proved by experiments using real images.