• 제목/요약/키워드: visual physiology

검색결과 115건 처리시간 0.03초

시각적 상사 척도의 신뢰도 검사 -급성 통증 측정- (Reliability of Visual Analog Scale in Assessment of Acute Pain)

  • 최자윤
    • 한국간호교육학회지
    • /
    • 제9권1호
    • /
    • pp.136-143
    • /
    • 2003
  • The purpose of this study was to test the reliability of visual analog scale in assessing the degree of acute pain related to blood sugar test. A sample of 113 subjects is composed of 56 DM patients and 57 their family who are admitted in a ward of medical part of C university hospital in Gwangju. Data are collected from July, 2001 to December, 2001. The degree of pain is twice measured in a week interval. Correlations were moderate between times in DM patients group and healty group. In both measures, correlations were high between VAS score and the score of color pain circle measurement tool. Visual analog scale is methodologically sound instrument for assessment of acute pain. Further study will be needed to evaluate the correlation with physiology measurement.

  • PDF

The effect of visual information on gait parameters with induced ankle muscle fatigue

  • Suh, Hye Rim;Hwang, Jin-Hee;Lee, Su-Young
    • Physical Therapy Rehabilitation Science
    • /
    • 제6권3호
    • /
    • pp.140-145
    • /
    • 2017
  • Objective: The purpose of this study was to investigate the effect of visual block with ankle joint fatigue on gait and dynamic balance ability. Design: Cross-sectional study. Methods: Thirty healthy young adults (men=15, women=15) between 22 to 25 years of age voluntarily participated in this study. All subjects performed the gait and dynamic balance test successively in two conditions: the visual block and the open eyes condition. Before the gait and dynamic balance test, muscle fatigue on the ankle joint was induced to all subjects by doing ankle dorsiflexion and plantarflexion alternately, and then gait parameters (step length, stride length, cadence, velocity, single limb support, and double limb support) were assessed by walking on the GAITRite system (CIR Systems Inc., USA). Subjects also performed the functional reach test (FRT) for assessment of dynamic balance. This study examined gait parameters and FRT scores in each visual block and open eyes condition. Results: The results showed that FRT scores with the visual block condition significantly decreased compared to without visual blocking (p<0.01). Step length, stride length, cadence, and velocity of gait parameters decreased significantly in the visual block condition (p<0.01) while there was no significant difference for single limb support. However, double limb support increased significantly in the visual block system (p<0.01). Conclusions: Therefore, blocking of visual information with muscle fatigue of the ankle joint can affect gait and balance ability of young adults and increase the risk of falls.

전력전자 기술을 응용한 의료장비 개발 사례 (Example Development of Medical equipment applying Power Electronics Technique)

  • 고종선;이태훈;김영일;김규겸;박병림;김민선
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2002년도 전력전자학술대회 논문집
    • /
    • pp.661-664
    • /
    • 2002
  • A control of the body posture and movement is maintained by the vestibular system, vision, and proprioceptors. Afferent signals from those receptors are transmitted to the vestibular nuclear complex, and the efferent signals from the vestibular nuclear complex control the eye movement. The postural disturbance caused by loss of the vestibular function results in nausea, vomiting, vertigo and loss of craving for life. The purpose of this study is to develop a off-vertical rotatory system for evaluating the function of semicircular canals and otolith organs, selectively, and visual stimulation system for stimulation with horizontal, vertical and 3D patterns. The Off-vertical axis rotator which stimulates semicircular canals and otolith organs selectively is composed of a comportable chair, a DC servo-motor with reducer and a tilting table controlled by PMSM. And a double feedback loop system containing a velocity feedback loop and a position feedback loop is applied to the servo controlled rotatory chair system. Horizontal, vertical, and 3D patterns of the visual stimulation for applying head mounted display are developed. And wireless portable systems for optokinetic stimulation and recording system of the eye movement is also constructed. The Gain, phase, and symmetry is obtained from analysis of the eye movement induced by vestibular and visual stimulation. Detailed data were described.

  • PDF

시야 가림막을 활용한 자세 조절 훈련이 중등도-중증 뇌성마비 아동의 머리 조절, 몸통 조절, 앉기 능력에 미치는 효과: 예비연구 (Effects of Postural Control Training Using a Visual Blind Board on Head Control, Trunk Control, and the Sitting Abilities of Children with Moderate to Severe Cerebral Palsy: A Pilot Study)

  • 김건우;이민구;함석찬
    • 대한물리의학회지
    • /
    • 제17권3호
    • /
    • pp.31-40
    • /
    • 2022
  • PURPOSE: This study was conducted to investigate the effects of postural control training using a visual blind board, on head control, trunk control, and the sitting abilities of children with moderate-to-severe cerebral palsy. METHODS: Ten children with moderate to severe cerebral palsy participated in this study. Postural control training with a visual blind board was given for 40 minutes per session, 3 times a week for 4 weeks (12 sessions). Before and after the intervention, head control, trunk control, and sitting abilities were quantified using the head control scale, Korean version-trunk control measurement scale, and the sitting part of the Korean version-gross motor function measure-88, respectively. RESULTS: Postural control with the visual blind board significantly improved the head control ability of children with moderate to severe cerebral palsy (p = .015). Their trunk control abilities also showed significant improvement after the intervention (p = .016). However, their sitting ability did not show a significant change. CONCLUSION: These results showed that postural control training using a visual blind board is effective in improving the head and trunk control abilities of children with cerebral palsy. Further studies with suitable sample sizes and control groups are needed to reach a conclusion about the use of postural control training with visual blind boards for improvement of postural control of children with moderate to severe cerebral palsy.

Clinical Application of Automatic EEG Interpretation: Automatic Detection of Artifacts and Vigilance Level

  • Nakamura, Masatoshi;Sugi, Takenao;Shibasaki, Hiroshi;Ikeda, Akio
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 1994년도 Proceedings of the Korea Automatic Control Conference, 9th (KACC) ; Taejeon, Korea; 17-20 Oct. 1994
    • /
    • pp.572-577
    • /
    • 1994
  • The automatic detection of artifacts and vigilance level as for pre-processing of the automatic EEG interpretation are discussed. The equations for detecting artifacts and vigilance level were determined such that they would conform to the procedures that an EEGer (one of the authors, H.S.) usually adopts for visual inspection of the actual EEG record. The automatic EEG interpretation was found to be improved by the newly developed pre-processing method even will artifact contamination or in drowsy condition of the subjects.

  • PDF

체외충격파 시술 후 내원한 족저근막염 환자 치험 1례 (Clinical Case Study on Plantar Fasciitis after Extracorporeal Shock Wave Treatment)

  • 추민규;최진봉;김환영;정일문
    • 동의생리병리학회지
    • /
    • 제23권1호
    • /
    • pp.232-236
    • /
    • 2009
  • Plantar fasciitis is most common cause of heel pain which starts anterior tubercle of calcaneus. It is chronic inflamation of plantar fascia, reduces collagen and water content of heel pain which incur the degenerative changes with elastic fiber weakness. We treated one patient after extracorporeal shock wave treatment. We diagnosed him with X-ray and treated her conservative maneuver as to oriental medical method. We measured Vas(Visual analogue scale) and thermographic picture of both leg. Visual analogue scale is from 10 to 4 and thermographic picture of both leg were improved in cases.

전정기능 평가를 위한 탈수직축 회전자극 시스템 및 HMD 시스템의 개발 (Development of the Off-vertical Rotary Chair and Visual Stimulation system for Evaluation of the Vestibular Function)

  • 김규겸;고종선;박병림
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2001년도 전력전자학술대회 논문집
    • /
    • pp.377-380
    • /
    • 2001
  • The vestibular system located in the inner ear controls reflex body posture and movement. It has the semicircular canals sensing an angular acceleration and the otolith organs sensing a linear acceleration. With this organic signal, medical doctor decide if a person has disease or not. To obtain this data, a precision stimular system is considered. Robust control is needed to obtain eye signals induced by off-vertical axis rotation because of an unbalanced load produced by tilting the axis of the system upto 30 degrees. In this study, off-vertical axis rotatory system with visual stimulation system are developed. This system is consisted of head mounted display for generating horizontal, vertical, and three dimensional stimulus patterns. Furthermore wireless recording system using RF modem is considered for noiseless data transmission.

  • PDF

반하사심탕(半夏瀉心湯)을 활용한 소화성 궤양 치험 3례 (Three Case Reports of Peptic Ulcer Patients Treated with Banhasasim-tang)

  • 박근희;최선욱;박수정;주종천;박혜선
    • 동의생리병리학회지
    • /
    • 제26권6호
    • /
    • pp.940-946
    • /
    • 2012
  • This study was designed to evaluate the effects of Korean medicine therapy(Banhasasim-tang) on a peptic ulcer patient. Three peptic ulcer patients with symptoms of epigastric pain, heartburn and nausea, were treated with Banhasasim-tang. The progress was evaluated with the Visual analogue scale. In all three cases, after 3 weeks of treatment with Banhasasim-tang, the patient's symptom of epigastric pain, heartburn and nausea evaluated with the Visual analogue scale improved. This study suggests that Korean medicine(Banhasasim-tang) could be effective in the treatment of peptic ulcer.

인간시각필터의 수학적 모델링 해석 (Mathematical Modeling Analysis of the Human Visual Filters)

  • 이적식
    • 대한전자공학회논문지SP
    • /
    • 제38권6호
    • /
    • pp.617-629
    • /
    • 2001
  • 인간시각체계에서 단순세포의 수용영역에 대한 수학적인 모델 연구가 정신물리학, 생리학, 신경과학 측면에서 발전되어 왔다. 여러 분야에서 사용되는 모델은 Gabor 복소함수, Gaussian 미분, Hermite 함수를 포함하며, 영상처리와 컴퓨터 시각 분야에 많이 응용되고 있다. 본 논문에서는 불확실성원리에 기초하여 고려된 함수들의 결합유효폭을 계산하고, 인간시각필터와 일치되는 중심주파수와 각 함수의 변수들을 결정하고, 결과적인 대역폭을 분석한다. 더욱이 함수들의 위치와 주파수 영역의 특성을 파악하여 정신물리학적으로 획득한 실험적인 데이터와의 관련성을 검토한다.

  • PDF

최적선형필터를 이용한 망막신경절세포 Spike Train으로부터의 시각자극 세기 변화 추정 (Estimation of Visual Stimulus Intensity From Retinal Ganglion Cell Spike Trains Using Optimal Linear Filter)

  • 류상백;김두희;예장희;김경환;구용숙
    • 대한의용생체공학회:의공학회지
    • /
    • 제28권2호
    • /
    • pp.212-217
    • /
    • 2007
  • As a preliminary study for the development of electrical stimulation strategy of artificial retina, we set up a method fur the reconstruction of input intensity variation from retinal ganglion cell(RGC) responses. In order to estimate light intensity variation, we used an optimal linear filter trained from given stimulus intensity variation and multiple single unit spike trains from RGCs. By applying ON/OFF stimulation(ON duration: 2 sec, OFF duration: 5 sec) repetitively, we identified three functional types of ganglion cells according to when they respond to the ON/OFF stimulus actively: ON cell, OFF cell, and ON-OFF cell. Experiments were also performed using a Gaussian random stimulus and a binary random stimulus. The input intensity was updated once every 90 msec(i. e. 11 Hz) to present the stimulus. The result of reconstructing 11 Hz Gaussian and binary random stimulus was not satisfactory and showed low correlation between the original and reconstructed stimulus. In the case of ON/OFF stimulus in which temporal variation is slow, successful reconstruction was achieved and the correlation coefficient was as high as 0.8.