• Title/Summary/Keyword: viscosity measurement

Search Result 336, Processing Time 0.029 seconds

A Study of the Characteristics of Thickness Distribution of Liquid Sheet Formed by Two Low Speed Impinging Jets (저속 충돌 제트로 생성되는 액막의 두께 분포 특성 연구)

  • Han, M.J.;Jeon, Y.U.;Seo, T.W.;Kang, B.S.
    • Journal of ILASS-Korea
    • /
    • v.26 no.1
    • /
    • pp.26-32
    • /
    • 2021
  • In this study, the thickness of the liquid sheet formed by two low speed impinging jets was measured by the direct contact method. The effects of jet velocity and liquid viscosity on the thickness were analyzed and the results were compared with theoretical modeling and optical thickness measurement results. The liquid film thickness decreased as the radius and circumferential angle increased. The jet velocity did not affect the liquid film thickness as predicted in theoretical modeling. In the theoretical modeling, there was no influence of the fluid properties on thickness, but in the case of low viscosity liquids, the thickness was predicted high, and it was well matched in high viscosity liquids. The direct measurement results showed no significant difference from the optical measurement results, thus confirming the reliability of the optical measurement method.

Experimental Study on the Effect of the Amount of Acrylic Viscosity Agent on the Physical Properties of High-Fluidity Concrete using Low-Binder (아크릴계 증점제 사용량이 저분체 고유동 콘크리트의 물리적 특성에 미치는 영향에 관한 실험적 연구)

  • Ko, Hye-Bin;Kong, Tae-Woong;Cho, In-Sung;Lee, Han-Seung
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2021.05a
    • /
    • pp.72-73
    • /
    • 2021
  • For the development of high-fluidity concrete using low-binder, The effect of the use of the developed acrylic viscosity agent on the physical properties of concrete evaluated. The amount acrylic viscosity agent used was 1.5%, 1.7%, and 2.0% based on the binder amount of 400kg/m3, and slump flow test, slump flow 500mm arrival time measurement, air volume measurement, and U-Box passing test were conducted to determine the effect of the physical properties of concrete. it was judged that 1.5% of the acrylic viscosity agent used in high-fluidity concrete using low-binder was most suitable.

  • PDF

Simultaneous measurements of red blood cell aggregation and blood viscosity in a slit rheometry with light transmission analysis (광 투사법을 이용한 슬릿 점도계에서의 적혈구 응집성 및 점도 측정에 관한 연구)

  • Park, Myung-Su;Ku, Yun-Hee;Shin, Se-Hyun;Suh, Jang-Su
    • Proceedings of the KSME Conference
    • /
    • 2004.04a
    • /
    • pp.1678-1681
    • /
    • 2004
  • The light-transmission technique has been applied to a slit rheometer for measuring red blood cell aggregation as well as blood viscosity over a range of shear rates. For measurement of blood viscosity and aggregation, instantaneous pressure and transmit-light intensity are measured with time. Using a precision pressure measurement, one can determine the shear stress and shear rate. In addition, a transmitted light through a blood sample indicates degree of RBC aggregation. With abruptly flowing with high shear rate, RBCs rapidly disaggregate and the intensity of the transmitted light becomes low. When continuously flowing with decreasing shear rate, RBCs tend to re-aggregate and the corresponding transmit-intensity gradually increases with time. The light intensity as a degree of RBC aggregation is plotted against shear rate and compared with blood viscosity. The advantages of this design are dual measurement at a time, simplicity, i.e., ease of operation and no moving parts, low cost, short operating time, and the disposable kit which is contacted with blood sample.

  • PDF

Experimental study on the shear thinning effects of viscosity index improver added lubricant by in-situ optical viscometer

  • Jang, Siyonl
    • Korea-Australia Rheology Journal
    • /
    • v.15 no.3
    • /
    • pp.117-124
    • /
    • 2003
  • Elastohydrodynamic lubrication (EHL) film is measured under the condition of viscosity index improver added to base oil. In-situ optical contact method using the interference principle make the measuring resolution of ~5 nm possible and enables the measuring range all over the contact area of up to ~300 $\mu\textrm{m}$ diameter. What is more important to the developed method by the author is that the measurement of EHL film thickness is possible in the range from 100 nm to 2 $\mu\textrm{m}$, which is the regime of worst contact failures in precision machinery. Viscosity index improver (VII) is one of the major additives to the modem multigrade lubricants for the viscosity stability against temperature rise. However, it causes shear thinning effects which make the film thickness lessened very delicately at high shear rate (over $10^5 s^{-1}$) of general EHL contact regime. In order to exactly verify the VIIs performance of viscosity stability at such high shear rate, it is necessary to make the measurement of EHL film thickness down to ~100 nm with fine resolution for the preliminary study of viscosity control. In this work, EHL film thickness of VII added lubricant is measured with the resolution of ~5 nm, which will give very informative design tool for the synthesis of lubricants regarding the matter of load carrying capacity at high shear rate condition.

Measurement of the Viscosity of Semi-Soild Foods by Extrusion Capillary Viscometer (Extrusion Capillary Viscometer를 이용한 반고체 식품의 점도 측정 방법)

  • 김길환;이부용;김동만
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.20 no.5
    • /
    • pp.509-512
    • /
    • 1991
  • Rheological property and apparent viscosity(η)of several semi-solid foods were measured with extrusion capillary viscometer. Apparent viscosities of several semi-solid foods ranged from 0.2714 Pa.s to 2.6453 Pa.s Rheological property of spread type semi-solid foods was pseudoplastic (with yield value). Especially, as the moisture content and temperature of Chungkook-jang spread increased, apparent viscosity decreased. On the contrary, as the added soybean oil content of Chungkook-jang spread increased, apparent viscosity also increased.

  • PDF

A Study of the Thickness Characteristics of the Liquid Sheet Formed by an Impinging Jet onto a Plate (평판 충돌 제트로 생성되는 액막의 두께 분포 특성 연구)

  • Kim, M.S.;Oh, J.H.;Jeong, H.M.;Kang, B.S.
    • Journal of ILASS-Korea
    • /
    • v.27 no.2
    • /
    • pp.77-83
    • /
    • 2022
  • In this study, the thickness of the liquid sheet formed by a low speed impinging jet onto a flat plate was measured by the direct contact method. The spatial distribution characteristics of the sheet thickness in the radial and circumferential directions, and the effects of jet velocity and liquid viscosity were analyzed. The measurement results were compared with the theoretical predictions. The wavy surface was observed in the case of low viscosity water, but not in the high viscosity aqueous glycerol solutions. The sheet thickness increased as the circumferential angle increased or the distance from the impinging point increased, but the thickness decreased as the circumferential angle increased around the impinging point. As the jet speed increased, the sheet thickness decreased, and the sheet thickness increased as the liquid viscosity increased. Comparison with the theoretical predictions showed that the measurement results agreed well in the case of low viscosity water or high viscosity liquids around the impinging point. The distribution characteristics of the sheet thickness can provide useful means for prediction of spray characteristics in splash plate injectors.

Mechanical Impedance at the Interface between a Torsionally-Vibrating Rod and a Viscous Fluid (비틀림 진동 봉과 점성 유체의 경계면에서의 역학적 임피던스)

  • 전한용;김진오
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2002.05a
    • /
    • pp.153-159
    • /
    • 2002
  • This paper deals with the measurement of the fluid viscosity by using the torsional vibration of a circular red excited by a torsional vibrator at one end. The effect of an adjacent viscous fluid on the torsional vibration of the rod has been studied theoretically and expressed in terms of the mechanical impedance. The theoretically-obtained trend that the mechanical impedance is proportional to the square root of the viscosity times the density of the fluid has been confirmed by the impedance measurement. The paper demonstrates that a torsionally-vibrating rod can be used as a sensor to measure the viscosity of a fluid.

  • PDF

Process Analysis and Experimental Evaluation by the Viscosity Measurement of Rheological Materials (레오로지 소재의 점도측정에 의한 공정해석 및 실험적 평가)

  • 서판기;강충길
    • Proceedings of the Korean Society for Technology of Plasticity Conference
    • /
    • 2002.05a
    • /
    • pp.70-73
    • /
    • 2002
  • Using a simple compression test, the viscosity measurement experiment is carried out with the grain-refined Al-Si alloy(A356). The measured rheological data are expressed with power-law(Ostwald-de Waele) model and using commercial package, MAGMAsoft, coefficients of Ostwald-de Waele model and Carreau-Yasuda model are calculated. To verify the viscosity data, the die is designed to be applicable to the semi-solid die casting of automotive component and filling test is carried out. The filling test and the simulation result are compared and in good agreement. Hereafter, these data are considered to be usefully allied other product in the semi-solid die casting.

  • PDF

Method for Rapid and Accurate Measurement of Chitosan Viscosity

  • No, Hong -Kyoon;Samuel P. Meyers
    • Preventive Nutrition and Food Science
    • /
    • v.4 no.2
    • /
    • pp.85-87
    • /
    • 1999
  • A simple and rapid method to estimate the viscosity of chitosan using laboratory pipettes was developed. The voscosities of nine different chitosan samples, prepared ini 1 % acetic acid at a 1% concentration , were measured with a standard viscometer. Prior to measurement of flow time of 1% chitosan solution with a pipette, twelve pipettes were assorted into three groups with flow times of 4, 5 and 6 sec after measuring passage of 9 ml of 1% acetic acid througth a 10 ml pipette. With each group of pipettes. flow time of 1% chitosan solution was determined by measuring the delivery time of 5 ml of the 10ml solution through a 10 ml pipette. Results of regression analyses revealed high linear relationship(R2=0.9812, 0.9663, and 0.9754) between viscosities calculated with a viscometer and flow times measured with 4, 5 or 6 sec group pipettes. The viscosity of chitosan could be readily and accurately estimated from these linear regression equation by measuring flow times based on pipette delivery.

  • PDF

A Study on the Thickness Characteristics of the Liquid Sheet Formed by an Impinging Jet Onto a Wall (벽 충돌 제트로 생성되는 액막의 두께 분포 특성 연구)

  • J. S. Lee;T. Y. Lee;J. M. Jo;B. S. Kang
    • Journal of ILASS-Korea
    • /
    • v.28 no.2
    • /
    • pp.68-74
    • /
    • 2023
  • In this study, the thickness of the liquid sheet formed by a low speed impinging jet onto a wall was measured by the direct contact method. The spatial distribution characteristics of the sheet thickness in the radial and circumferential directions, and the effects of jet velocity and liquid viscosity were analyzed. The measurement results were compared with the theoretical predictions for two impinging jets. The wavy surface was observed for low viscosity water, but not for high viscosity glycerol solutions. The sheet thickness decreased as the circumferential angle or the distance from the impinging point increased. The sheet thickness increased as the liquid viscosity increased. Comparison with the theoretical predictions showed some differences from the measurement results.