• 제목/요약/키워드: viscometer

검색결과 247건 처리시간 0.027초

회전형 레오미터와 진동형 점도계를 이용한 세라믹 슬러리의 점도 비교 (Comparison of the Viscosity of Ceramic Slurries using a Rotational Rheometer and a Vibrational Viscometer)

  • 지혜;임형미;장영욱;이희수
    • 한국세라믹학회지
    • /
    • 제49권6호
    • /
    • pp.542-548
    • /
    • 2012
  • The viscosity of a ceramic slurry depends on the slurry concentration, particle shape and size, hydrodynamic interactions, temperature, shear rate, pre-treatment condition and the method of measurement with the selected equipment. Representative ceramic slurries with low to high viscosity levels are selected from colloidal silica, barium titanate slurry and glass frit paste. Rotational rheometers and vibrational viscometers are used to compare the measured viscosity for various ceramic slurries. The rotational rheometer measured the viscosity according to the change of the shear rate or the rotational speed. On the other hand, the vibrational viscometer measured one point of the viscosity in a fixed vibrational mode. The rotational rheometer allows the measurement of the viscosity of a ceramic paste with a viscosity higher than 100,000 cP, while the vibrational viscometer provides an easy and quick method to measure the viscosity without deformation of the ceramic slurry due to the measurement method. It is necessary to select suitable equipment with which to measure the viscosity depending on the purpose of the measurement.

회전식 점도측정기를 이용한 ER 및 MR유체의 특성 비교 (The Comparison of Properties of ER and MR Fluids Using a Rotational Viscometer)

  • 이영록;전도영
    • 유변학
    • /
    • 제11권2호
    • /
    • pp.73-81
    • /
    • 1999
  • 회전식 점도 측정기를 이용하여 상용화된 전기유변(electrorheological, ER)유체와 자기유변(magnetorheological, MR)유체의 특성을 비교하여 이를 이용한 장치 설계시 두 유체 중에 유리한 것을 선택하는데 도움이 되고자 하는 것이 본 논문의 의도이며, 이러한 유체의 특성에서 전단변형률의 변화에 따른 전단응력의 변화, 온도변화에 따른 전단응력의 변화, 작용하는 장의 세기에 따른 전단응력의 변화 등을 비교하였다. 온도의 변화에 따른 유체의 특성 변화는 MR유체가 ER유체보다 적게 받는 경향이 있었다. 두 유체의 응용 예로서 제작된 댐퍼의 경우에 유압 시험기를 이용하여 인장과 압축될 때 장의 On/Off에 따른 시간지연과 감쇄력을 비교하였다.

  • PDF

과도유동현상을 이용한 모세관점도계 개발 및 적용 (Development and Application Capillary Tube Viscometer Transient Flow Concept)

  • 서상호;조민태;김동주;노형운
    • 유체기계공업학회:학술대회논문집
    • /
    • 유체기계공업학회 2002년도 유체기계 연구개발 발표회 논문집
    • /
    • pp.489-492
    • /
    • 2002
  • The objective of the present study were to measure the viscosities of non-Newtonian fluids by the transient flow concept in a capillary tube and to apply to hemodynamic studies and pump performance evaluations. The developed capillary tube viscometer could be used to measure the viscosities of the non-Newtonian fluids for a wide range of the shear rate by a run of experiment in a very short time interval. The measured viscosities of water and blood fur different shear rates were good agreement with those of the well established data. The measured viscosities for muddy water varied with the shear rates.

  • PDF

진동장에서의 전단박화 유체 점도의 특성 연구 (Characteristics of Shear-Thinning Fluid Viscosity under Traversal Vibration)

  • 구윤희;이지형;신세현
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2002년도 학술대회지
    • /
    • pp.317-320
    • /
    • 2002
  • The effect of vibration on the viscosity of a shear-thinning fluid was investigated with a newly designed pressure-scanning capillary viscometer. The viscometer was designed to measure non-Newtonian viscosity continuously over a range of shear rates at a time. Low frequency vibration was applied perpendicularly to the direction of the flow. The effect of the transversal vibration was investigated for both Newtonian fluids and non-Newtonian fluids. The experimental results showed that the vibration had no effect on the viscosity of the Newtonian fluids. However, the vibration caused a significant reduction of the shear-thinning fluid viscosity. The viscosity reduction was strongly dependent on both vibration frequency and shear rate. In addition, the viscosity reduction was affected by the amplitude of vibration, and, the bigger amplitude applied, the more viscosity reduction occurred.

  • PDF

젖소의 준임상형유방염 검진을 위한 Rolling Ball Viscometer법과 California Mastitis Test법의 비교시험 (Comparisons of the Rolling Ball Viscometer Test and California Mastitis Test for the Subclinical mastitis Screening Test of Dairy Cow)

  • 박동수;하영주;이주홍;조희택;강호조
    • 대한수의사회지
    • /
    • 제23권8호
    • /
    • pp.537-543
    • /
    • 1987
  • In order to compare the diagnosis values the Rolling Ball Viscometer(RBV) and the California Mastitis Test(CMT) for detection of bovine subclinical mastitis, A total of 2204 quarter milk samples from 565 heads of Holstein in Gyeongnam area were examined d

  • PDF

낙구식 점도계를 이용한 아이스슬러리의 점도측정에 관한 연구 (A Study on the Measuring Method of Ice Slurry Viscosity Using the Falling Sphere Viscometer)

  • 김명준;유직수;임재근;최순열
    • 설비공학논문집
    • /
    • 제19권8호
    • /
    • pp.593-598
    • /
    • 2007
  • The present study has dealt with the measuring method of ice slurry viscosity using falling sphere viscometer. The experimental apparatus was composed by test section and high-speed video system. And the spheres used in this study were alumina and glass. The main parameters were ice packing factor (IPF) and falling velocity of sphere so the acquired results were discussed for these parameters. The viscosity of ice slurry was calculated by using measured falling velocity and moving distance at instantaneous time and the Stokes hypothesis was used for this calculation. It was clarified that possible measuring range was $IPF\;=\;0.06{\sim}0.14$ of this type of measuring device and measuring method. In addition, it was clarified that the viscosity of ice slurry increased to increase of ice packing factor (IPF) of ice slurry.

혈액점도 측정용 평행판 점도계 (A parallel plate viscometer for blood viscosity measurement)

  • 서동길;안경현;강지훈;박상수
    • 문화기술의 융합
    • /
    • 제9권4호
    • /
    • pp.331-335
    • /
    • 2023
  • 혈액의 점도가 높아질수록 혈액은 더 끈적하고 흐름이 어려워지므로 혈전의 발생 가능성이 높아져 허혈성 뇌경색의 발생 확률이 증가한다. 혈액 점도 측정은 최근 순환기계 질환의 예방을 위하여 그 중요성이 강조되고 있으며 혈액의 점도를 쉽고 정확하게 측정할 수 있는 점도계의 필요성이 대두되고 있다. 본 연구에서는 평행판 점도계 ARS-Medi에 의한 점도표준액과 인공혈액의 측정값들을 국제적으로 정확성과 신뢰성을 인정받는 TA instrument의 Ares-G2로 측정한 값들과 비교하였다.. 뉴턴성 용액인 N44 표준용액의 점도는 모든 전단율에서 두 기기 간에 거의 완벽하게 일치하였다, 비뉴턴성 용액인 인공혈액의 경우 가장 낮은 전단율인 1 rad/s 에서는 약 10%의 차이를 보였으나, 임상적으로 유의한 전단율인 10 rad/s 이상에서는 두 기기간의 측정값이 오차범위 내에서 모두 일치하였다. 우리는 새로 개발한 혈액 전용 평행판형 점도계 ARS-Medi가 1회용 평행판을 사용하므로 혈액 점도 측정의 편의성과 위생성이 향상되어 임상에 매우 유용할 것으로 기대한다.

낙구식 점도계와 모세관 점도계를 이용한 점탄성유체의 점성과 특성시간의 측정 (Measurements of Viscosity and Characteristic Times of Viscoelastic Fluids with the Falling ball Viscometer and Capillary Tube Viscometer)

  • 전찬열;황태성;유상신
    • 유변학
    • /
    • 제2권2호
    • /
    • pp.19-27
    • /
    • 1990
  • 레이저와 타이머장치를 설치한 낙구식 점도계에서 구와 니들이 주어진 구간을 통과 하는 시간을 측정하여 종말속도를 정확히 결정하였고 점성이 작은유체와 낮은 전단률 점성 과 영전단률 점성은 속이 빈 알루미늄 구와 니들이 이용하여 측정하였다. 알루미늄 구와 니 들의 속에 철분을 삽입하여 밀도를 다양하게 변화시켰다. 낙구식 점도계에서 측정한 낮은 전단률 점성과 영 전단률 점성 그리고 모세관점도계에서 측정한 높은전단률 점성과 무한 전 단률 점성을 이용하여 점탄성 유체의 특성이완시간을 결정하였다. 실린더 속의 시험용 유체 를 교란시키지 않고 밑면에 떨어진 구를 회수하는 장치를 설치하였다. 이 장치는 하나의 구 로써 점탄성유체의 특성확산시간을 측정하는데 대단히 효과적이었다. Polyacrylamide Separan AP-273 용액(농도 500-200 wppm)의 특성이안시간과 특성화산시간을 낙구식 점도 계와 모세관 점도계의 실험결과를 이용하여 결정하고 폴리며 용액의 퇴화 현상을 실험적으 로 분석하였다.

  • PDF

모세관내 과도유동현상을 이용한 비뉴턴유체의 점도측정 (Viscosity Measurement of Non-Newtonian Fluids Using the Transient Flow Phenomena in the Capillary Tube)

  • 조민태;서상호;유상신
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2001년도 춘계학술대회논문집E
    • /
    • pp.738-741
    • /
    • 2001
  • The purpose of the present study is to measure the viscosity of liquid in the capillary tube viscometer using the unsteady flow concept. The capillary tube viscometer is consisted of a small cylindrical reservoir, capillary tubes, and the mass flow rate measuring system interfaced with computer. Two capillary tubes with 1.152 and 3.002 mm I.D. are used to determine the diameter effects on the viscosity measurements. The instantaneous shear rate and gravitational driving force in the capillary tube are determined by measuring the mass flow rate through the capillary tube instantaneously. The measured viscosities of water and aqueous Separan solution are in good agreement with the reported experimental data.

  • PDF