• Title/Summary/Keyword: viscometer

Search Result 247, Processing Time 0.023 seconds

Kinitics of Thixotropy of Aqueous Bentonite Suspension

  • Kisoon Park;Taikyue Ree
    • Journal of the Korean Chemical Society
    • /
    • v.15 no.6
    • /
    • pp.293-303
    • /
    • 1971
  • The theological properties of aqueous suspensions of Black Hills bentonite were measured by using a Couette-type viscometer. Three kinds of flow units in aqueous bentonite suspension were postulated. Each has a different average relaxation time, one Newtonian. One of the non-Newtonian types is thixotropic, and the other is non-thixotropic. The thixotropic non-Newtonian unit is transformed to a Newtonian unit by shear stress. If the stress is relieved, the transformed unit returns to its original state. Two flow equations were derived by introducing chemical kinetics consideration for such a transition into the generalized theory of viscous flow. One equation describes the "upcurve," a diagram of rate of sheat versus shear stress, obtained by increasing the rate of shear, and the other relates to the "downcurve" obtained by decreasing the shear rate. The equations satisfactorilly describe the experimental thixotropic hysteresis of bentonite suspensions. The equations also were successfully applied to the flow curves of the suspensions containing various amounts of monovalent electrolyte (KCI).

  • PDF

Ettect of Electrolytes on Flow Properties of Aqueous Bentonite Suspension

  • Kisoon Park;Taikyue Ree;Henry Eyring
    • Journal of the Korean Chemical Society
    • /
    • v.15 no.6
    • /
    • pp.303-312
    • /
    • 1971
  • Dependence of the flow behavior of aqueous suspension of Black Hills bentonite on the concentration and the types of electrolytes was stydied. The flow properties were measured with a Couette-type totational viscometer. On addition of monovalent cations, the apparent viscosity determined from the reproducible flow curves (shear rate vs. shear stress) decreased followed by a rise as the ionic concentration further increased. Addition of multivalent cations (di- and tri-) resulted in the viscosity which increased to a maximum then decreased to a constant value. Anions of different chatges produced essentially the same relationship between viscosity and electrolyte concentration. The flow behavior of the electrolyte-containing suspensions was rationalized in terms of the Derjaguin-Landau-Verwey-Overbeek theory of colloidal stability and the generalized theory of viscosity.

  • PDF

Effect of Flavors on the Viscosity and Gelling Point of Aqueous Poloxamer Solution

  • Rhee, Yun-Seok;Shin, Young-Hee;Park, Chun-Woong;Chi, Sang-Cheol;Park, Eun-Seok
    • Archives of Pharmacal Research
    • /
    • v.29 no.12
    • /
    • pp.1171-1178
    • /
    • 2006
  • This study examined the effects of flavors, which are usually added to improve the appeal of pharmaceutical agents, on the viscosity and gelling point of 18% (w/w) aqueous poloxamer 407 solutions. Monoterpenes, esters, alcohols, aldehyde ketones and lactone type flavors were examined. The concentrations of flavor ranged from 0.1 to 1.0%(w/w). After adding a flavor to the aqueous poloxamer 407 solution, the viscosity of the solution was measured using a Brookfield viscometer, and the gelling point was determined from the viscosity vs. temperature plot. The gelling point of the aqueous poloxamer 407 solution decreased with increasing concentration of flavors except for coumarin, vanillin and ethylvanillin. Thermal analysis with DSC showed an interaction between the flavors and poloxamer 407. These results suggest that the flavors bind to the hydrophilic end chains of poloxamer 407, which increases the viscosity, causing gelation at lower temperatures.

Characteristics of Carbon Nano Fluid Added PVP (PVP가 첨가된 탄소나노유체의 특성에 대한 연구)

  • Seo, Hyang-Min;Park, Sung-Seek;Kim, Nam-Jin
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.22 no.5
    • /
    • pp.289-295
    • /
    • 2010
  • In this study, the enhancement of the thermal conductivity of water in the presence of multi-walled carbon nanotubes, MWCNT, was investigated. Sodium Dodecyl Sulfate, SDS, and Polyvinylpyrrolidone, PVP, were employed as the dispersant. SDS or PVP was added in pure water. And then, MWCNT of 0.0005, 0.001, 0.002, 0.003, 0.004, 0.005, 0.01, and 0.02 vol% was dispersed respectively. The thermal conductivity and the viscosity were measured with a transient hot-wire instrument built for this study and the DV II+ Pro viscometer. The results showed that PVP had good thermal conductivity at 300 wt% and this was better than that of SDS 100 wt%, also, the viscosity of nano fluid added PVP rapidly increased until 0.02 vol%.

Rheological Properties of Cement Pastes Blended Finex-Slag Powder (파이넥스 슬래그 미분말을 혼합한 시멘트 페이스트의 유동특성)

  • Lee, Keun-Jae;Byun, Seung-Ho;Song, Jong-Taek
    • Journal of the Korean Ceramic Society
    • /
    • v.46 no.6
    • /
    • pp.657-661
    • /
    • 2009
  • In this study, rheological properties of cement pastes containing ground Finex-slag (4000, 6000, 7000 c$m^2$/g) were investigated bymini-flow test and coaxial cylinder viscometer. And also blast furnace slag(4000, 6000, 7000 c$m^2$/g) were used for comparison. According to the experimental results, Finex-slag and blast furnace slag showed very similar trend in the rheological properties of the cement pastes. The fluidity of cement pastes blended Finex-slag and blast furnace slag powder were improved by high replacement ratio. In the relationship of plastic viscosity and yield stress appeared the tendency of the proportion greatly. And in the relationship of plastic viscosity, yield stress and mini-flow appeared the tendency of the inverse proportion.

Rheological Characteristics of Debris Flows (토석류 이동의 레올로지적 특성)

  • 김상규;서홍석
    • Geotechnical Engineering
    • /
    • v.13 no.5
    • /
    • pp.125-132
    • /
    • 1997
  • It is observed that debris mitred with a wide range of soil particles and water moves downwards like viscous fluid soon after a landslide has triggered. An Assumption can be made from the field observation that the debris flow behaves as a kind of non(non-Newtoniron) Newtonian fluid which has non linear viscosity. In this study, a series of viscosity tests are carried out to measure rheological properties of debris by using a viscometer with semples taken from a landslide site. It is proved that debris flows behave as Bingham plastic mod el of non-Newtonian fluid. This model can be used predict the movement of debris flows.

  • PDF

Vibration Control of a Semi-Active Engine Mount Using an ER Fluid (ER 유체를 이용한 반능동형 엔진마운트의 진동제어)

  • 전영식
    • Journal of the Korean Society of Safety
    • /
    • v.12 no.4
    • /
    • pp.47-56
    • /
    • 1997
  • This paper presents the vibration control of an engine mount featuring an ER(electro-rheological) fluid. The Bingham properties of the ER fluid to be employed to the ER engine mount are experimentally obtained through Coeutte type viscometer. The ER engine mount is devised ant its governing equation is derived. After evaluating the performance of the ER engine mount on the basis of the mathematical model, the novel type of the ER engine mount is then designed and manufactured. The electric field-dependent transmissibility of the ER engine mount is evaluated by changing the particle concentration and the electrode gap size. To investigate the control performance of the ER engine mount, neuro-control algorithm is adopted. It is shown that the proposed ER engine mount has prominent capabilities of controlling the damping force by tuning the electric fields and excellent vibration isolation performance.

  • PDF

Uncertainty Evaluation of Viscosity Measurement Standards (점도 측정표준 불확도 평가)

  • Choi, H.M.;Yoon, B.R.;Lee, Y.B.;Choi, Y.M.;Lee, S.H.
    • 유체기계공업학회:학술대회논문집
    • /
    • 2005.12a
    • /
    • pp.295-301
    • /
    • 2005
  • Viscosity measurement standards were evaluated according to ISO/IEC 17025. The step-up procedure was employed to calibrate a series of capillary type master viscometers. Uncertainty was calculated with evaluation of various uncertainty factors affected in viscosity measurement. The maximum expanded uncertainty(U) of the master viscometer was $3.0{\times}10^{-3}$(at the confidence level of 95 %). This evaluation example will be useful in viscosity measurement uncertainty determination of other standard measurement.

  • PDF

Acoustic Viscosity Characteristics of Oils with High Molecular Weight VI Improver Additives (고분자량 점도지수향상제가 첨가된 오일의 음향점도 특성)

  • Kong, H.;Ossia, C.V.;Han, H.G.
    • Tribology and Lubricants
    • /
    • v.25 no.4
    • /
    • pp.236-242
    • /
    • 2009
  • Oil viscosity is one of the important parameters for machinery condition monitoring. Basically, it is expressed as kinematic viscosity measured by capillary flow and dynamic or absolute viscosity measured by rotary shear viscometry. Recently, acoustic wave techniques appear in the market, measuring viscosity as the product of dynamic viscosity and density. For Newtonian fluids, knowledge of density allows conversion from one viscosity parameter to the other at a specific shear rate and temperature. In this work, oil samples with different chain lengths of viscosity index (VI) improvers and concentrations were examined by different viscometric techniques. Results showed that acoustic viscosity measurements give misleading results for oil samples with high molecular weight VI improvers and at low temperatures ${\leq}40^{\circ}C$.

A Study of Rheology Properties of AM50A Magnesium Alloy (AM50A 마그네슘합금의 레오로지 특성에 관한 연구)

  • Han S.H.;Lee J.H.;Kang C.G.
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2006.05a
    • /
    • pp.431-432
    • /
    • 2006
  • In this study, the effect of the temperature of magnesium slurry was investigated by mechanical stirring method. The evaluations of rheological behavior of AM50A magnesium alloy were measuring of viscosity and microstructures in the semisolid state. The apparent viscosity was investigated at continuous cooling rate using a concentric cylinder viscometer. Measurement of viscosity measures torque that act to stirrer rotating in slurry doing continuous cooling using torque-meter and expressed by POWER-LAW. Microstructures were observed after mechanical stirring that enforce time at steady state temperature of solid fraction.

  • PDF