• Title/Summary/Keyword: video imaging

Search Result 241, Processing Time 0.025 seconds

City-Scale Modeling for Street Navigation

  • Huang, Fay;Klette, Reinhard
    • Journal of information and communication convergence engineering
    • /
    • v.10 no.4
    • /
    • pp.411-419
    • /
    • 2012
  • This paper proposes a semi-automatic image-based approach for 3-dimensional (3D) modeling of buildings along streets. Image-based urban 3D modeling techniques are typically based on the use of aerial and ground-level images. The aerial image of the relevant area is extracted from publically available sources in Google Maps by stitching together different patches of the map. Panoramic images are common for ground-level recording because they have advantages for 3D modeling. A panoramic video recorder is used in the proposed approach for recording sequences of ground-level spherical panoramic images. The proposed approach has two advantages. First, detected camera trajectories are more accurate and stable (compared to methods using multi-view planar images only) due to the use of spherical panoramic images. Second, we extract the texture of a facade of a building from a single panoramic image. Thus, there is no need to deal with color blending problems that typically occur when using overlapping textures.

Design of Subband Image Encoder by Discrete Wavelet Transform

  • Huh, Young;Rhee, Kang-Hyeon
    • Proceedings of the IEEK Conference
    • /
    • 2002.07b
    • /
    • pp.864-867
    • /
    • 2002
  • Introduction of digital communication network such as Integrated Services Digital Networks(ISDN) and digital storage media have rapidly developed. Due to a large amount of image data, compression is the key techniques in still image and video using digital signal processing for transmitting and storing. Digital image compression provides solutions for various image applications that represent digital image requiring a large amount of data. in this paper, the proposed DWT(Discrete Wavelet Transform) filter bank is consisted of simple architecture, but it is efficiently designed that a user obtains a wanted compression rate as only input parameter. If it is implemented by FPGA chip, the designed encoder operates in 12MHz.

  • PDF

Epilepsy Surgery of the Cerebral Paragonimiasis

  • Lee, Woo-Jong;Koh, Eun-Jeong;Choi, Ha-Young
    • Journal of Korean Neurosurgical Society
    • /
    • v.39 no.2
    • /
    • pp.114-119
    • /
    • 2006
  • Objective : The authors investigate appropriate evaluation and surgical methods in treatment of the cerebral paragonimiasis accompanying epilepsy. Methods : Thirteen patients with the cerebral paragonimiasis accompanying epilepsy were included for this study. Preoperative evaluation methods included history taking, skin and serologic tests for Paragonimus westermani, neurologic examinations, computerized tomography, magnetic resonance imaging, amytal test, PET or SPECT, and video-EEG monitoring with depth and subdural grid electrodes. Seizure outcome was evaluated according to Engel's classification. Results : Surgical methods were temporal lobectomy including lesions in six, lesionectomy in five, and temporal lobectomy plus lesionectomy in two. Postoperative neurological complications were not noticed, and seizure outcomes were class I in 12 patients [92%], class II in one [8%]. Conclusion : In patients with a cerebral paragonimiasis accompanying epilepsy, further evaluation methods must be done to define the epileptogenic zone, and complete resection of the epileptogenic zone with different surgical methods should be performed for seizure control.

Study on the Real Time Medical Image Processing (실시간 의학 영상 처리에 관한 연구)

  • Yoo, Sun-Kook;Lee, Gun-Ki;Paik, Nam-Chill;Kim, Won-Ky
    • Journal of Biomedical Engineering Research
    • /
    • v.8 no.2
    • /
    • pp.117-117
    • /
    • 1987
  • The medical image processing system is intended for a diverse set of users in the medical Imaging Parts. This system consists of a 640 Kbyte IBM-PC/AT with 30 Mbyte hard disk, special purpose image processor with video input devices and display monitor. Image may be recorded and processed in real time at sampling rate up to 10 MHz. This system provides a wide range of image enhancement processing facilities via a menu-driven software packages. These facilities include point by point processing, image averaging, convolution filter and subtraction.

An Implementation of Laser image drawing with the uiversal joint (유니버셜 관절을 이용한 2차원 레이저 영상 구현)

  • Kim, Jong-Koul;Kim, Tae-Kagn;Lee, Keon-Young
    • Proceedings of the KIEE Conference
    • /
    • 2000.07d
    • /
    • pp.2705-2707
    • /
    • 2000
  • The branch of the laser imaging has implemented 3D graphics, color graphics and video images after it drew a simple image by development the salvo's X-Y scanner in 1960 year. Now it is used as the multimedia show of an event and an advertisement. The latest issue of laserist is the ability to generate laser images with the same ease and speed associated with traditional computer graphics. All laser projector used in the interior of a countris was imported from other country. The most important component of the laser projector is the speed and the accuracy of a actuator and the software which actuates the controller on computer. In this paper we developed the controller with a universal joint and the PC based user interface software in order to implement the laser image of two dimension, and will prepare the base of beginning the home laser projector

  • PDF

A Study on the Rotating Displacement Measurement of Rigid Body by ESPI Method (ESPI법에 의한 강체 회전 변위 측정에 관한 연구)

  • 김경석;홍명석
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.1 no.2
    • /
    • pp.125-133
    • /
    • 1993
  • Electronic Speckle Pattern Interferometry(ESPI) using a CW laser, a video system and image processor was applied to the rotating displacement of rigid body. ESPI require no special surface preparation or attachments and displacements between any two arbitrary points on the surface can be measured. The characteristic speckle pattern formed when imaging a scattering surface illuminated by laser light retains phase information, which can be used for interferometric measurement of surface displacement. The application of this principle to measuring in-plane displacement resolved in one direction is described, together with the novel use of television equipment to detect and process the information contained in the speckle pattern. This is faster, and more convenient and versatile than customary photographic methods.

  • PDF

Successful Diagnosis and Treatment of a Pancreaticopleural Fistula in a Patient Presenting with Unusual Empyema and Hemoptysis

  • Kim, Eunji;Ahn, Hyo Yeong;Kim, Yeong Dae;I, Hoseok;Cho, Jeong Su
    • Journal of Chest Surgery
    • /
    • v.52 no.3
    • /
    • pp.174-177
    • /
    • 2019
  • Pancreaticopleural fistula (PPF) is a rare complication in patients with pancreatitis. Its symptoms are similar to those of empyema or pleural effusion; therefore, it is important to consider PPF in the differential diagnosis. Herein, we describe the diagnosis and treatment of PPF in a patient presenting with unusual empyema and delayed hemoptysis.

Designing a 3D-CNN for Non-Contact PPG Signal Acquisition Based on Video Imaging (영상기반 비접촉식 PPG 신호 취득을 위한 3D-CNN 설계)

  • Tae-Wan Kim;Chan-Uk ,Yeom;Keun-Chang Kawk
    • Proceedings of the Korea Information Processing Society Conference
    • /
    • 2023.05a
    • /
    • pp.627-629
    • /
    • 2023
  • 생체 신호를 분석하여 사용자의 건강과 정신 상태를 예측하고, 관련 질병에 관해 예방하는 연구가 늘어나고 있다. 생체 신호 중 심박은 사람의 육체, 정신적인 상태를 반영하는 대표적인 신호이지만 기존의 접촉 패드를 통한 ECG나 광학 센서를 통한 PPG로 심박을 예측할 때는 구속적인 환경이 필요하여 일상적인 상황 속에 적용하기 어려웠다. 이러한 단점을 해결하고자 본 논문은 UBFC-RPPG 데이터셋의 동영상 프레임을 RGB 채널마다 다른 가중치를 적용하는 전처리를 하여 학습 데이터의 크기를 줄이면서 정확도를 높이고, 3D-CNN을 활용한 딥러닝으로 순간적인 영상에서도 PPG 신호를 예측할 수 있도록 1초 전처리 영상을 학습한 후, 신호를 예측하는 것을 목표로 한다. 이렇게 비접촉식으로 취득된 신호는 더 다양한 환경에서의 감정분류, 우울증 진단, 질병 감지 등 다양한 분야에 활용될 수 있다.

Komi type 2 pancreaticobiliary maljunction: Minimal access surgical treatment (with video)

  • Freddy Pereira Graterol;Francisco Salazar Marcano;Yeisson Rivero-Moreno;Yajaira Venales Barrios
    • Annals of Hepato-Biliary-Pancreatic Surgery
    • /
    • v.28 no.3
    • /
    • pp.393-396
    • /
    • 2024
  • Pancreaticobiliary maljunction (PBM) is associated with the development of neoplasms of bile ducts. Cholecystectomy with diversion of the biliary-pancreatic flow is considered the treatment of choice. To describe the surgical treatment employed for a patient with Komi's type 2 PBM and its long-term results. Laparoscopic common bile duct exploration, intraoperative cholangioscopy, and Roux-en-Y hepatico-jejunostomy were performed. Postoperative evolution was satisfactory. The patient was discharge 72 hours after the surgery. There was no associated morbidity. At 62-month follow-up, clinical examination, laboratory tests, and imaging studies confirmed an adequate patency of bilio-enteric anastomosis. The surgical approach employed was effective and safe, with satisfactory long-term results.

When Evaluated Using CT Imaging Phantoms AAPM Phantom Studies on the Quantitative Analysis Method (AAPM Phantom을 이용한 CT 팬텀 영상 평가 시 정량적 분석 방법에 관한 연구)

  • Kim, Young-Su;Ye, Soo-Young;Kim, Dong-Hyun
    • The Journal of the Korea Contents Association
    • /
    • v.16 no.8
    • /
    • pp.592-600
    • /
    • 2016
  • AAPM CT performance for special medical equipment quality control checks using a standard phantom for evaluation, using the evaluator's subjective assessment as to minimize errors due computerized assessment program to evaluate their usefulness. Phantom for evaluation AAPM CT Performance Phantom: was used, the default shooting conditions are the same as quality control checks. And, we use IMAGE J to evaluate the program. Quantitative evaluation with CT attenuation coefficient and the noise measurement, the uniformity measurement, the slice thickness measurement, contrast resolution of the measurement, a phantom image of the spatial resolution determined by the evaluation program is evaluated as self-extracting the result after processing the image, CT uniformity measurement for the evaluation that was smaller and the standard deviation of a video image processing more uniform slice thickness measurements it is difficult to evaluate due to the difference of the ratio of the measured value of the phantom image. Contrast resolution was measured cylindrical diameter 6th evaluate the shape of a circle obtained a mean value and a standard deviation of diameters, the spatial resolution of the group of source, including acceptance criteria automatically extracted result as a result of both the number of the extracted circularIt appeared. Evaluate the source image and video processing, and video to qualitative evaluation by gross were processed video image is shown excellent results. If the evaluators in order to minimize the errors of subjective judgment based on the results of the above should be done with a quantitative evaluation and qualitative evaluation utilizes a computerized assessment program is considered that further evaluation be made more efficient.