• Title/Summary/Keyword: video imaging

Search Result 241, Processing Time 0.026 seconds

DEVELOPMENT OF CCD IMAGING SYSTEM USING THERMOELECTRIC COOLING METHOD (열전 냉각방식을 이용한 극미광 영상장비 개발)

  • Park, Young-Sik;Lee, Chung-Woo;Jin, Ho;Han, Won-Yong;Nam, Uk-Won;Lee, Yong-Sam
    • Journal of Astronomy and Space Sciences
    • /
    • v.17 no.1
    • /
    • pp.53-66
    • /
    • 2000
  • We developed low light CCD imaging system using thermoelectric cooling method collaboration with a company to design a commercial model. It consists of Kodak KAF-0401E(768$\times$512 pixels) CCD chip, thermoelectric module manufactured by Thermotek. This TEC system can reach an operative temperature of $-25^{\circ}C$. We employed an Uniblitz VS25s shutter and it has capability a minimum exposure time 80ms. The system components are an interface card using a Korea Astronomy Observatory (hereafter KAO) ISA bus controller, image acquisition with AD9816 chip, that is 12bit video processor. The performance test with this imaging system showed good operation within the initial specification of our design. It shows a dark current less than 0.4e-/pixel/sec at a temperature of $-10^{\circ}C$, a linearity 99.9$\pm$0.1%, gain 4.24e-/adu, and system noise is 25.3e-(rms). For low temperature CCD operation, we designed a TEC, which uses a one-stage peltier module and forced air heat exchanger. This TEC imaging system enables accurate photometry($\pm$0.01mag) even though the CCD is not at 'conventional' cryogenic temperatures(140k). The system can be a useful instrument for any other imaging applications. Finally, with this system, we obtained several images of astronomical objects for system performance tests.

  • PDF

Video Rate Image Signal Processing for Optical Coherence Tomography (광학 영상기를 위한 실시간 영상 신호 처리에 관한 연구)

  • 나지훈;이병하;이창수
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.10 no.3
    • /
    • pp.239-248
    • /
    • 2004
  • Optical coherence tomography(OCT) is high resolution imaging system which can see the cross section of microscopic organs in the living tissue. In this paper, we analyze the relation between the light source and the resolution of modulated signal in Michelson interferometer. We construct 1-D OCT signal processing hardware such as amplifiers, filters, and demodulate electronic signals from the photo detector. In order to get 2-D OCT image, the synchronization among optical delay line, sample stage and A/D converter is dealt with. In experiments, we verify analog and digital signal processing blocks which apply to the stacks of glasses. Finally we aquire high resolution 2-D OCT image with respect to the onion tissue. We expect that this result can be applied to the medical instrument through performance improvement.

Phenomenological behavior of Bubbles and dry spots at CHF on a short heated wall: Pool boiling of R-113 (소형가열면에서 CHF 발생시 Bubble 및 Dry Spot의 현상학적 거동 R-113의 수조비등)

  • Chung, H.J.;Kim, B.D.;Chun, S.Y.;No, H.C.
    • Proceedings of the KSME Conference
    • /
    • 2001.06d
    • /
    • pp.189-194
    • /
    • 2001
  • A simultaneous visualization of the behavior of bubbles and dry spots has been carried out for pool boiling of R-1l3 on a horizontal heater. From video imaging and image processing analysis, the formation of bubbles and dry spots occurs simultaneously, and therefore they should be considered as a synchronized concept rather than independent identities. The dry spot density is equivalent to the active site density in the region before CHF. At CHF point, large dry areas due to the coalescence of neighboring dry areas cover the heater surface.

  • PDF

Difficult airway management in a patient with a parapharyngeal tumor

  • Ji, Sung-Mi
    • Journal of Dental Anesthesia and Pain Medicine
    • /
    • v.15 no.3
    • /
    • pp.153-156
    • /
    • 2015
  • A 47-year-old man was referred to the operating room to treat a dentigenous cyst of the mandibular bone. Initial assessment of the airway was considered normal. However, after the induction of anesthesia, we could not intubate the patient due to severe distortion of the glottis. Fiberoptic bronchoscopy and video laryngoscopy were not effective. Intubation using a retrograde wire technique was successful. After the conclusion of surgery, the patient recovered without any complications. Subsequent magnetic resonance imaging of the patient's neck showed a $6{\times}4{\times}8.6cm$ heterogeneous T2 hyperintense, T1 isointense well-enhancing mass in the prestyloid parapharyngeal space. The patient was scheduled for excision of the mass. We planned awake intubation with fiberoptic bronchoscopy. The procedure was successful and the patient recovered without complications. Anesthetic induction can decrease the muscle tone of the airway and increase airway distortion. Therefore, careful airway assessment is necessary.

Study on the Digital VCR System and Its Image Enhancement Techniques (디지털 VCR의 영상압축 기술 및 그의 화질 개선에 관한 연구)

  • 이형호;백준기
    • Journal of Broadcast Engineering
    • /
    • v.1 no.2
    • /
    • pp.142-151
    • /
    • 1996
  • The digital video cassette recorder(DVCR) is considered as next generation VCR due to its performance breakthrough in various aspects, such as digital recording and various digital image processing techniques. The purpose of our study is to understand the standardized specifications of the DVCR system, evaluate the performance of the system, and improve the quality of the reconstructed DVCR image. More specifically, in order to enhance the DVCR Image we consider a series of discrete cosine transform(DCT), quantization, inverse DCT, and Inverse quantization as a degradation process of the Imaging system, and propose a fast adaptive image restoration algorithm for reducing blocking artifacts.

  • PDF

Acute Ethanol Reduces Calcium Signaling Elicited by K+ Depolarization in Cultured Cerebellar Granule Neurons

  • Kim, Jong-Nam
    • Toxicological Research
    • /
    • v.16 no.1
    • /
    • pp.63-66
    • /
    • 2000
  • The effects of acute ethanol on the high K+ induced $Ca^{2+}}$ signals were examined from primary cultures of cerebellar granule neurons. $Ca^{2+}}$ signals were measured with Calcium Green-1 based microscopic video imaging. Because $Ca^{2+}}$ signal was low in most of granule neurons without stimuli, high KCI was used for depolarization. In most case, acute exposure to ethanol reduced the peak amplitude of the $Ca^{2+}}$ signals, induced by high K+, even though low concentration of ethanol(2~10mM) was used and the effects lasted more than 30min. In was also possible to see differences of ethanol inhibition, i.e. the temporal pattern of $Ca^{2+}}$ signal reductions and the strength of inhibition of $Ca^{2+}}$ signals in cerebellar granule neurons. These results indicate that low concentration of ethanol has diverse actions on the $Ca^{2+}}$ signals in cerebellar granule neurons.

  • PDF

Thermal Imager Implementation Using Infrared Sensor (적외선 센서를 이용한 열상장비의 구현)

  • Yu, W.K.;Yoon, E.S.;Kim, C.W.;Song, I.S.;Hong, S.M.
    • Proceedings of the KIEE Conference
    • /
    • 1992.07b
    • /
    • pp.1250-1254
    • /
    • 1992
  • This paper describes the designed and fabricated thermal imaging system with the SPRITE(Signal PRocessing in The Element) detector, operating in the 3-12 micron band. This system consists of an afocal telescope, a scan unit containing the SPRITE detector, an electronic processor unit and a cooler. The optical scan system utilizing rotating polygon and oscillating mirror, is 2-dimensional serial/parallel scan type using five elements of the detector. And the electronic processor unit performs digital scan conversion to reform the parallel data stream into serial analog data compatable with conventional RS-170 video. The scan field of view is 40 ${\times}$ 26.7 and the MRTD(Minium Resolvable Temperature Difference) is 0.6 K at 7.5 cycles/mm. The acquired thermal image indicates that this system has a satisfactory performance.

  • PDF

Construction of HMD-based Interactive Realistic Media Algorithm Using L-System (L-System을 이용한 HMD기반 인터렉티브 실감형 미디어 알고리즘 구축)

  • Lim, Sang Guk
    • Journal of Korea Multimedia Society
    • /
    • v.23 no.1
    • /
    • pp.58-66
    • /
    • 2020
  • 5G-based HMD technology grew rapidly in the context of the environment change of convergence technology media and mobile networks in the fourth industrial era. It has also grown into a core technology that transforms our digital visual system. However, there is no research or system that can understand and verify radical visual system changes. Therefore, it is necessary to have an engineering understanding and verification of the diffusion of HMD media imaging devices. Beyond the distinction between virtual and real, research is urgently needed on the new three-dimensional interface of the 21st century through viewer participation. For this reason, research on the algorithm structure of interactive video media using L-System is an essential process and will be a guide to understanding the virtual reality interactive environment.

A Study on the Imaging Formation in Ferroelectric Film

  • 조국래
    • Journal of the Korean Graphic Arts Communication Society
    • /
    • v.14 no.1
    • /
    • pp.133-146
    • /
    • 1996
  • Eastman Kodak Co. has announced the concept of photo CD System in September, 1990 With Photo CD System technology, Kodak Co. Furnishes a convinent way to view, use and store photographic images. The heart of this system is a format provides progressively higher levels of image quality to meet the demands of NTSC, PAL and HDTV video displays as well as hard copy output. Also, image professionals are instrested in the capability of Photo CD, such as a way to store image at low cost in a high-resolution digital format that can be played back on different computer platforms. Many editors wish to use Photo CD images in the printing and publishing industry. However, Photo CD images were not processed detail enhancement and some others to use in the lithographic offset printing. Therefore, in this paper discribes a method to improve the sharpness of Photo CD images.

  • PDF

Unattended fire detection system using a wireless communication device (무선통신 단말기를 이용한 무인화재 감지시스템)

  • Chang, Rak-Ju;Lee, Soon-Yi;Kang, Suk-Won
    • Proceedings of the Korea Contents Association Conference
    • /
    • 2015.05a
    • /
    • pp.25-26
    • /
    • 2015
  • The Unattended fire detection system using a wireless communication device is designed in this paper. If a fire occurs in some area, the system can detect and automatically extinguish the fire. The major functions for the system are: Unattended detection system for fire based on wireless communication system and Automatic extinguish device system; Thermal imaging camera and video camera system; Monitoring viewer and map viewer system.

  • PDF