• Title/Summary/Keyword: vibration method

Search Result 8,826, Processing Time 0.043 seconds

Experimental Study for Prediction of Ground Vibration Responses by the Low-vibration Pile Driving Methods (저진동 파일시공법에 따른 지반진동 응답 예측을 위한 실험적 연구)

  • Kang, Sung-Hoo;Jeoung, Sug-Kyu;Park, Sun-Joon
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.21 no.4
    • /
    • pp.299-306
    • /
    • 2011
  • This study investigated the SIP-method as a low-vibration, low-noise engineering method. The ground vibrations caused by the SIP-method were measured and analyzed in each step. From the analysis results, quantitative ground vibration values and reliable vibration estimation equations were proposed. Furthermore, the ground vibrations caused by the SIP-method were compared with the ground vibrations caused by other methods presented by existing studies. Based on the vibration estimation equation with 50 % reliability, the ground vibration values by the SIP-method at the distance of 10~150 m corresponded to 17~57 % of the ground vibration values by the equation proposed by Attewell & Famer, and 14~96 % of the ground vibration values by the equation proposed by Prof. Park in his study using a diesel drop hammer. These results showed that the ground vibration reduction effect of the SIP-method was higher those of other general engineering methods. Finally, the permissible scope of work using the SIP-method which meets the domestic vibration standards was presented.

Comparison of Assessment method of Blast Vibration (발파 진동 평가의 문제점과 개선방안)

  • Chang, Seo-Il;Lee, Jae-Won;Kim, Hyung-Kon
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2002.11a
    • /
    • pp.357.2-357
    • /
    • 2002
  • The blast vibration can generate occupants dissatisfy as well as damage of physics nearby building. Then blast vibration estimation issue important problems. But, now blast vibration prediction inside-outside country not established objective method according to blast number to express magnitude of vibration. In this study, Our propoes show our country problem of blast vibration about blast vibration measurement and this problems be able to find improve method. (omitted)

  • PDF

A Study on Application of Vibration Testing Method (진동 시험 기법의 적용에 관한 고찰)

  • Lee, Chang-Hoon
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2012.10a
    • /
    • pp.587-591
    • /
    • 2012
  • Review of practical vibration test methods those applied in various industrial fields - such as automotive industry, electrics and electronics industry, defense industry and aerospace industry - is described on this paper. Swept sine test, random vibration test and advanced vibration techniques are explained according to their parametric values and also application fields of each test method are suggested by the characteristic of each method. For more proper application of each test method, standardized test specifications should be always reviewed and revised according to the transition of environmental factors.

  • PDF

A Study on the Characteristics of Piling Vibration by SIP Method about Variation of Various Earth Conditions (지반조건의 변화에 따른 SIP 항타진동의 특성에 관한 실험적 연구)

  • Kwak, Kwang-Soo;Park, Jae-Young;Lee, Byeong-Yun;Kim, Jae-Soo
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2000.06a
    • /
    • pp.927-932
    • /
    • 2000
  • Recently, construction vibration has caused annoyance for a number of dwellers in nearby construction field and that induced from operating of large construction equipment, has become a very serious issue in our living environment. But, construction vibration standard of our living environment. But construction vibration standard of our country is efficient. Especially, directly blow method(diesel piling method, oil pressure method, etc) has caused much problems of highly impactive vibration. Construction works, in order to solve these problem, will be used SIP(Soilcement Injected Precast Pile) method of low vibration equipment. In this point, this study attempts to survey on the characteristics of piling vibration by SIP method for various earth conditions in construction field. And this study intends to get the basic data to establish a standard about construction vibration.

  • PDF

Torsional Vibration Stress Analysis for Shafting in Reciprocating Machine by Transfer Stiffness Coefficient Method (전달강성계수법에 의한 왕복 기계 축계의 비틀림진동 응력해석)

  • 최명수
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.14 no.8
    • /
    • pp.749-756
    • /
    • 2004
  • While designing shafting in reciprocating machines with internal combustion engines which derive generators, pumps, and vehicles, it is very important to calculate the additional stress of shafting by torsional vibration. In this paper, the transfer stiffness coefficient method which is based on the successive transfer of stiffness coefficient was applied to the calculation of the additional stress of shafting in reciprocating machine by torsional vibration. In order to confirm the effectiveness of the present method, a propulsion shafting with a diesel engine in a vessel was considered as the computational example of shafting in reciprocating machine. The results calculated by the present method were compared with those of the modal analysis method, the mechanical impedance method, and free vibration analysis.

A Study on the Vibration Behavior of Composite Laminate under Tensile Loading by ESPI (ESPI에 의한 인장하중 하에서의 복합재 적층판의 진동 거동에 관한 연구)

  • Yang, Seung-Pil;Kim, Koung-Suk;Jung, Hyun-Chul;Chang, Ho-Seob;Kim, Chong-Soo
    • Proceedings of the KSME Conference
    • /
    • 2000.11a
    • /
    • pp.516-521
    • /
    • 2000
  • Most of studies, using ESPI method, have handled tension, thermal and vibration analysis, and is limited to isotropic materials. However, tension and vibration simultaneously are loaded in real structure. Also, almost study using ESPI method is locally limited to the analysis on the isotropic materials and a few studies on the anisotropic materials have reported. Existing methods, such as the accelerometer method and FEA method, to analyze vibration have some disadvantages. Using the accelerometer method that is generally used to analyze vibration phenomena, it is impossible to analyze vibration on the oscillating body and one can observe no vibration mode shape during experiment. In case of the FEA method, it is difficult to define boundary conditions correctly if the shape of a body tested is complex, and one can just obtain vibration mode shapes on the peak amplitude in each modes. In this study, plane plate of stainless steel(STS304), isotropic material, that is used as structural steel is analyzed about vibration characteristics under tension. Also, in the study of stainless steel, the characteristics of composite material(AS4/PEEK) used as high strength structural material in aircraft is evaluated about vibration under tension, and studies the effect of tension on vibration.

  • PDF

Study on the Precision Method of Measuring angular displacement for the Angular Vibration Calibration System (회전 진동 교정 장치 구현을 위한 고정밀 측정기법에 대한 연구)

  • Cheung, Wan-Sup;Lee, Yong-Bong;Lee, Doo-Hee
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2004.11a
    • /
    • pp.685-688
    • /
    • 2004
  • This paper addresses the study on developing the angular vibration calibration system which requires the highly accurate measurement technique of the amplitude and period of an oscillating angular motion. Two developed models for the low and high frequency ranges are introduced and their main features are also compared. In addition to the angular vibration exciters, a new measurement method, referred to the 'equi-angle sampling method', is proposed and its theoretical backgrounds are introduced. The proposed method is shown to provide much less measurement uncertainty, compared the fringe counting method. Experimental results demonstrate what amount of angular vibration amplitude measurement uncertainty is improved by suing the proposed equi-angle sampling method.

  • PDF

The Study on The Evaluation of The Ground Vibration of Cast in Place Concrete Pile Method Effect to Precision Equipment (현장타설 말뚝 공법의 지반진동이 정밀장비에 미치는 영향성 평가)

  • Hong, Byung-Kuk;Kim, Young-Chan;Jang, Kang-Seok;Yoon, Je-Won;Sim, Sang-Deok
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2011.04a
    • /
    • pp.97-102
    • /
    • 2011
  • The size of TV and TFT-LCD are bigger and bigger for the next generation exposure equipment install that existing fab are getting a lot of additions. When the new fab build an extension that the shortening of the construction and non-vibration are use cast in place concrete pile method. In this study when lay the foundation of existing fab adjoin use vibration monitoring system are rotator type all casing method among cast in place concrete pile method. The evaluation of ground vibration of rotator type all casing method effect to precision equipment and vibration area of influence.

  • PDF

Application of Finite Element Method and Taguchi Method to Reduce Floor Impact Vibration in Apartment Buildings (공동주택의 바닥충격진동 저감을 위한 유한요소법 및 다구찌법의 활용)

  • Seo, Sang-Ho;Jeon, Jin-Yong
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2005.11a
    • /
    • pp.385-388
    • /
    • 2005
  • Finite element method and Taguchi method were used to reduce the floor impact vibration of the reinforced concrete slab in the apartment buildings. At first, experimental results show that sound peak components to influence the rating of floor impact sound insulation were coincident with natural frequencies of the reinforced concrete slab, and there is a high linear relation between floor impact vibration and sound. The tables of orthogonal arrays were used for finite element analysis with 5 factors related to slab shape parameters and its results were analyzed by statistical method. The most effective factor to reduce the floor impact vibration was the length of living/kitchen room and the floor impact vibration was predicted by 30% reduction in the acceleration peak by the optimal design values of the factors.

  • PDF

Experimental Study for Prediction of Ground Vibration Responses by the Low-Vibration Pile Driving Methods (저진동 파일시공법에 따른 지반진동 응답 예측을 위한 실험적 연구)

  • Park, Sun-Joon;Kang, Sung-Hoo;Jung, Seug-Gyu
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2010.10a
    • /
    • pp.201-207
    • /
    • 2010
  • In this study, the SIP (Soil-cement Injected precast Pile) method among the Low-vibration & Low-noise pile driving methods was decided into study compensation. Ground vibrations by the SIP methods step by step divide and were analyzed. Quantitative response values and ground vibration equations with reliability were presented from findings of this study. Also, vibration responses that are occurred by the SIP method of construction were compared as quantitative with vibration responses by general method of construction that are presented in existent study. Ground vibration values by the SIP method correspond to level of 17 ~ 57% of values that are assumed by the Attewell & Famer's equation, respectively, and these result compares in reliability 50% and separated distance 10 ~ 50 m. Also, those values were analyzed that correspond to level of 14 ~ 96% of ground vibration values by the Prof. Park's equation, respectively. Construction limit extents, separation distances from vibration occurs position, were presented that can satisfy domestic criteria for vibration control for the SIP methods. Those presented in this paper were divided newly according to reliability.

  • PDF