• Title/Summary/Keyword: vibration level

Search Result 2,070, Processing Time 0.025 seconds

GFRP retrofitting effect on the dynamic characteristics of model steel structure

  • Tuhta, Sertac
    • Steel and Composite Structures
    • /
    • v.28 no.2
    • /
    • pp.223-231
    • /
    • 2018
  • Nowadays, there are a great number of various structures that have been retrofitted by using different FRP Composites. Due to this, more researches need to be conducted to know more the characteristics of these structures, not only that but also a comparison among them before and after the retrofitting is needed. In this research, a model steel structure is tested using a bench-scale earthquake simulator on the shake table, using recorded micro tremor data, in order to get the dynamic behaviors. Columns of the model steel structure are then retrofitted by using GFRP composite, and then tested on the Quanser shake table by using the recorded micro tremor data. At this stage, it is needed to evaluate the dynamic behaviors of the retrofitted model steel structure. Various types of methods of OMA, such as EFDD, SSI, etc. are used to take action in the ambient responses. Having a purpose to learn more about the effects of GFRP composite, experimental model analysis of both types (retrofitted and no-retrofitted models) is conducted to evaluate their dynamic behaviors. There is a provision of ambient excitation to the shake table by using recorded micro tremor ambient vibration data on ground level. Furthermore, the Enhanced Frequency Domain Decomposition is used through output-only modal identification. At the end of this study, moderate correlation is obtained between mode shapes, periods and damping ratios. The aim of this research is to show and determine the effects of GFRP Composite implementation on structural responses of the model steel structure, in terms of changing its dynamical behaviors. The frequencies for model steel structure and the retrofitted model steel structure are shown to be 33.916% in average difference. Finally, it is shown that, in order to evaluate the period and rigidity of retrofitted structures, OMA might be used.

A Study on Certification Requirements for Small Unmanned Aerial System(sUAS) (소형 무인항공기 운용을 위한 관련법 현황 및 인증방안 연구)

  • Ahn, Hyojung;Park, Jonghyuk
    • Transactions of the KSME C: Technology and Education
    • /
    • v.3 no.1
    • /
    • pp.71-78
    • /
    • 2015
  • Although there are differences in the classification of category adopted by each country, small UAS is usually classified as the one less than 25 kg. UAS has been mainly used for military and public purposes, but in recent years, it has spread to the private sector for hobby, media, and so on. Especially, considering the nature of the operating region and applications, it is necessary to improve operating time, noise and vibration in small UAS to ensure the same level of safety with a manned aircraft. This is because the drone can pose health and safety hazard through collision with manned aircraft or crashing into the ground. In this paper, we investigated operational regulations in the United States and European countries. Based on the investigation, a domestic system development plan for small UAS operation is under development.

Development of Simulator using RAM Disk for FTL Performance Analysis (RAM 디스크를 이용한 FTL 성능 분석 시뮬레이터 개발)

  • Ihm, Dong-Hyuk;Park, Seong-Mo
    • Journal of the Institute of Electronics Engineers of Korea CI
    • /
    • v.47 no.5
    • /
    • pp.35-40
    • /
    • 2010
  • NAND flash memory has been widely used than traditional HDD in PDA and other mobile devices, embedded systems, PC because of faster access speed, low power consumption, vibration resistance and other benefits. DiskSim and other HDD simulators has been developed that for find improvements for the software or hardware. But there is a few Linux-based simulators for NAND flash memory and SSD. There is necessary for Windows-based NAND flash simulator because storage devices and PC using Windows. This paper describe for development of simulator-NFSim for FTL performance analysis in NAND flash. NFSim is used to measure performance of various FTL algorithms and FTL wear-level. NAND flash memory model and FTL algorithm developed using Windows Driver Model and class for scalability. There is no need for another tools because NFSim using graph tool for data measure of FTL performance.

Liquefaction Prevention and Damage Reduction Effect of Reinforcement by Sheet Pile Using 1-G Shaking Table Test (1-G 진동대 실험을 이용한 시트파일 보강재의 액상화 및 피해 방지 효과)

  • Sim, Sung Hun;Yoon, Jong Chan;Son, Su Won;Kim, Jin Man
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.24 no.5
    • /
    • pp.211-217
    • /
    • 2020
  • Earthquake preparedness has become more important with recent increase in the number of earthquakes in Korea, but many existing structures are not prepared for earthquakes. There are various types of liquefaction prevention method that can be applied, such as compaction, replacement, dewatering, and inhibition of shear strain. However, most of the liquefaction prevention methods are applied before construction, and it is important to find optimal methods that can be applied to existing structures and that have few effects on the environment, such as noise, vibration, and changes in underground water level. The purpose of this study is to estimate the correlation between the displacement of a structure and variations of pore water pressure on the ground in accordance with the depth of the sheet file when liquidation occurs. To achieve this, a shaking table test was performed for Joo-Mun-Jin standard sand and an earth pressure, accelerometer, pore water pressure transducer, and LVDT were installed in both the non-liquefiable layer and the liquefiable layer to measure the subsidence and excess pore water pressure in accordance with the time of each embedded depth. Then the results were analyzed. A comparison of the pore water pressure in accordance with Hsp/Hsl was shown to prevent lateral water flow at 1, 0.85 and confirmed that the pore water pressure increased. In addition, the relationship between Hsp/Hsl and subsidence was expressed as a trend line to calculate the expected settlement rate formula for the embedded depth ratio.

Structural Analysis using Equivalent Models of Active Control Devices (능동형 제진장치의 등가모델을 이용한 구조해석)

  • Park, Ji-Hun;Yun, Soo-Yong
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.25 no.4
    • /
    • pp.339-346
    • /
    • 2012
  • In this paper, equivalent models for active control devices are proposed so that building structures with such devices are analyzed using commercial structural analysis programs for the assessment of the structural members under active vibration control. Equivalent link models represent active control device with a virtual linear spring and dashpot, and equivalent force models are control force history acting at the installation point in structural models. Active controllers are designed based on the reduced-order models for a vertical cantilever model and a high-rise building model and corresponding equivalent models are determined from control gain matrices. Based on acceleration, displacement and member force responses, the effectiveness of the equivalent models is verified. As a result, proposed equivalent models, of which equivalent link model showed better performance, appear to enable detailed investigation of structural behavior to the extent of member force level.

Design and Evaluations of Underwater Hydrophone with Self Noise Suppressing Structures -Part Ⅰ. Noise Transfer Characteristics & Effects of Structure Modifications - (저 잡음 수중 청음기의 설계 방안 연구 -Ⅰ. 잡음 전달 특성 및 구조 변경 영향 -)

  • Im, Jong-In;Roh, Young-Rae
    • The Journal of the Acoustical Society of Korea
    • /
    • v.16 no.2
    • /
    • pp.10-15
    • /
    • 1997
  • The hydrophones is mounted in many applications on a vibrating surface and functions as an underwater acoustic signal receiver without sensing the vibrations from the mounting surface. However, their performance is usually degraded by the interference of exterior noises such as acoustic cavitation in water stream, host structural vibration in the hull, and propeller motions. This paper describes the design and evaluation of a self noise suppressing hydrophones which shows very poor sensitivity to the external noises, first, effects of the external noise on the its receiver performance is simulated with finite element method(FEM). Second, the geometrical variations are implemented on the original structure that include additional air pockets and acoustic walls which work as acoustic shied or scatter of the noises. The results show that the effect of the external noise is the most significant when it is applied near to the bottom of the side wall of the hydrophones. The transverse noise induced by the outside water flow is isolated most effectively when a thin compliant (damping) layer combined with two air pockets is inserted to the circumference of the nose. Noise level is reduced about fifty nine percent of that of the original structure.

  • PDF

A Clinical Investigation in Primary Male Infertility During Recent 5 Years (최근 5년간 원발성 남성불임증 환자의 임상적 분석)

  • Kim, Tae-Hyoung;Kim, Kyung-Do;Kim, Sae-Chul
    • Clinical and Experimental Reproductive Medicine
    • /
    • v.21 no.3
    • /
    • pp.253-259
    • /
    • 1994
  • A clinical investigation was undertaken on primary male infertility patients of recent 5 years. The results obtained were as follow: 1. Suspective etiologic factors were: 1) testicular failure, 36.1 %; 2) varicocele, 18.7%; 3) endocrine abnormality, 13.5%; 4) obstruction, 13.5%; 5) idiopathic, 10.9%; 6) cryptorchidism, 2.6%; 7) necrospermia, 0.9%. 2. On semen analyses, azoospermia was found in 55.8%, single abnormal parameter in 21.5 %, and multiple/all abnormal parameter in 22.7% of the 163 cases. 3. For the evaluation of the sensitivity and specificity of noninvasive variables in predict in obstruction as the cause of azoospermia in patient who had undergone testicular biopsy, the testicular size and serum follicle-stimulating hormone(FSH) level revealed 100% of sensitivity. 4. Among the 43 patients with a testicular biopsy confirmed diagnosis there was a significant difference in testicular size, ejaculate volume(p<0.0001) and serum FSH(p<0.0001) between patients with testicular failure and those with ductal obstruction. 5. Of 93 treated patients with primary male infertility, 42 were managed by medical treatment including endocrine treament, retrograde ejaculation treatment, infection treatment and observation; 29 were managed by surgical treatment including varicocelectomy, vasovasostomy, vasoepididymostomy and TUR of ejaculatory duct; 20 were managed by sperm preparation treatment including artificial insemination(AI), electroejaculation plus AI and vibration ejaculation plus AI ; 2 were managed by microscopic epididymal sperm aspiration plus IVF, repectively. 6. 42 patients who could be followed-up, 21 patients(50%) impregnated their wives.

  • PDF

Design of Instrumented Pod for Flight Aeroacoustic Environment (비행 공력음향 환경 측정을 위한 계측포드 설계)

  • Jun, Oo-Chul;Kim, Sang-Yong
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.40 no.6
    • /
    • pp.536-541
    • /
    • 2012
  • An instrumented pod has been developed to measure the aeroacoustic environment as well as the conventional data such as load, vibration, and aerodynamic heating of fighters during flight tests, confirming to the recently developed external pod design for fighters. This study presents the development of the measurement system in detail, being the first indigenous effort in its kind. The pod was designed to meet the requirements of the MIL-HDBK-1763 and MIL-STD-810 Method 515, which are the base to determine the locations and range of sensors. The Endevco 8510B-2 was selected as the sensor to withstand the harsh environment during the flight tests. In order to assess the integrity of the fabricated pod design, a ground run-up test of a KF-16 has been conducted with the pod installed at Station 5. The test results show that the system works well but the sound level exceeds the predetermined sensor range. The sensor range has been readjusted for flight test performed later.

An application plan of NSWC-98/LE1 when predicting the reliability of mechanical components of design and development phase (체계 개발 단계별 기계 부품에 대한 신뢰도 예측 시 NSWC-98-LE1 적용 방안)

  • Kwon, Ki Sang;Park, Eun Sim;Cho, Cha Hyun;Lee, Dong Woo;Lee, Su Jung
    • Journal of the Korean Society of Systems Engineering
    • /
    • v.4 no.1
    • /
    • pp.35-43
    • /
    • 2008
  • Generally, in analysis of reliability of Design and Development Phase, reliability of electrical components is analyzed based on standards such as MIL-HDBK-217F, Bellcore Issue 4,5,6 by analyzing stress of architectural side (Power, Voltage, Current and quality level of components) of weapon system and stress of operational side (operational environment, operational temperature, Operational Profile). But the reliability of mechanical components is analyzed based on the data book of failure history of mechanical parts called NPRD-95(Nonelectronic Parts Reliability Data-95) without any analysis of above stress. However, even if it's the same mechanical parts, it might have different failure rate(fatigue, wear, corrosion) during operation depending on how weary(stress : pressure, vibration, temperature during operation) the parts are. Therefore, analyzing reliability using just data book can cause big difference in reliability instead of analyzing based upon stressfulness that parts might have, operational concept, and other various factors. Thus, This paper will guide the way of predicting reliability by organizing ways of predicting reliability for system organization and adopt ing NSWC-98/LE1(Naval Surface Warfare Center-98/LE1) for mechanical components.

  • PDF

A Study of Design of Hollow Fiber Membrane Modules for using in Artificial Lung by the PZT Actuator

  • Kim, Gi-Beum;Kim, Seong-Jong;Hong, Chul-Un;Lee, Yong-Chul;Kim, Min-Ho
    • Journal of Biomedical Engineering Research
    • /
    • v.27 no.4
    • /
    • pp.143-153
    • /
    • 2006
  • The purpose of this work was to assess and quantify the beneficial effects of gas exchange, while testingto the various frequencies of the sinusoidal wave that was excited by the PZT actuator, for patients suffering from acute respiratory distress syndrome (ARDS) or chronic respiratory problems. Also, this paper considered a simulator to design a hollow type artificial lung, and a mathematical model was used to predict a behavior of blood. This simulation was carried out according to the Montecarno's simulation method, anda fourth order Runge-Kutta method was used to solve the equation. The experimental design and procedure are then applied to the construction of a new device to assess the effectiveness of the membrane vibrations. As a result, the vibration method is very effective in the increase of gas transport. The gas exchange efficiency for the vibrating intravascular lung assist device can be increased by emphasizing the following design features: consistent and reproducible fiber geometry, and most importantly, an active means of enhancing convective mixing of water around the hollow fiber membranes. The experimental results showed the effective performance of the vibrating intravascular lung assist device. Also, we concluded that important design parameters were blood flow rates, fiber outer diameter and oxygen pressure drop. Based on the present results, it was believed that the optimal level of blood flow rates was 200$cm^3$/min.