• 제목/요약/키워드: vibration

검색결과 25,040건 처리시간 0.036초

충격시험을 이용한 고정밀장비의 진동허용규제치 결정기법에 관한 연구 (A Study on the Determination of Vibration Criteria for Vibration Sensitive Equipments Using Impact Test)

  • 이홍기;박해동;김두훈;김사수
    • 소음진동
    • /
    • 제7권2호
    • /
    • pp.247-254
    • /
    • 1997
  • In the case of a precision equipment, it requires a vibration free environment to provide its proper function. Especially, lithography and inspection devices, which have sub-nanometer class high accuracy and resolution, have come to necessity for producing more improved giga class semiconductor wafers. This high technology equipments require very strict environmental vibration standard in proportion to the accuracy of the manufacturing, inspecting devices. The vibration criteria are usually obtained either by the real vibration exciting test on the equipment or by the analytical calculation. This paper proposes a new method to solve this problem at a time. The permissible vibration level to a precision equipment can be easily obtained by analyzing a process of Frequency Response Function. This paper also demonstrates its effectiveness by applying the proposed method to finding the vibration criteria of a Computer Hard Disk Driver by Impact Test.

  • PDF

국소진동 보호구의 적합성 평가와 진동공구에 적합한 가진 스펙트럼에 관한 연구 (A Study on the Compatibility Evaluation of Hand-arm Adequate Vibration and an Oscillating Spectrum for Vibrating Tools)

  • 윤희경;김태구;윤유성
    • 한국안전학회지
    • /
    • 제24권1호
    • /
    • pp.60-68
    • /
    • 2009
  • The aim of this paper is to evaluate the compatibility of anti-vibration gloves, to predict the attenuation of vibration with different types of anti-vibration gloves, to estimate the spectra of the ISO 10819 standard, and to present an oscillating spectrum adequate for vibrating tools. This paper use two ISO standards for the measurement and evaluation of hand-arm vibration. Some anti-vibration gloves can attenuate vibration, but all the anti-vibration gloves in this study do not satisfy the ISO 10819 requirements. In case of equal vibration types, the outside materials are effective in order of leather, fabrics and rubber-coating. Anti-vibration gloves manufactured in the United State satisfy ISO 10819 criteria using United State subjects, but do not satisfy ISO 10819 using Japanese subjects. M-spectrum acceleration exists below 10Hz and H-spectrum exists above 500Hz. Generally vibrating tools have the peak of Z-axis, but generation of vibration differ from each vibrating tools.

전단벽식 건축구조물의 수직진동 전달특성에 관한 실험연구 (An Experimental Study on the Vertical Vibration Transfer according to Shear Wall Building Structures due to Exciting Vibration Forces)

  • 전호민
    • 한국전산구조공학회:학술대회논문집
    • /
    • 한국전산구조공학회 2005년도 춘계 학술발표회 논문집
    • /
    • pp.159-166
    • /
    • 2005
  • The vibration on building structures due to exciting vibration forces has been studied only for the vibration level on existing buildings. Recently, several researches have been performed on the prediction of vertical vibration on structures by using an analytical method. However, these studies have been focused on mainly the vibration analysis through analytical modeling of structures. This study aims to investigate the characteristics of vertical vibration transfer in terms of the directions of transfer(upward transfer and downward transfer) on the shear wall building structures due to 2 type vibration forces. In order to examine the characteristics of vertical vibration transfer, the mode analysis and the impact experiment were conducted several times on one building structure. The results of this study suggest that the characteristics of vertical vibration transfer are different in terms of the directions of transfer.

  • PDF

지중 매설 가스 배관의 열차 주행 속도에 따른 진동 속도 특성 (Vibration Velocity Response of Buried Gas Pipelines according to Train Speed)

  • 김미승;선진선;김건;김문겸
    • 한국전산구조공학회:학술대회논문집
    • /
    • 한국전산구조공학회 2008년도 정기 학술대회
    • /
    • pp.561-566
    • /
    • 2008
  • Recently, because of development of the high speed train technology, the vibration loads by train is significantly increased ever than before. This buried gas pipelines are exposed to both repeated impact loads, and, moreover, they have been influencing by vibration loads than pipeline which is not located under vehicle loads. The vibration characteristic of pipeline is examined by dynamic analysis, and variable is only train speed. Since an effect of magnitude of vibration loads is more critical than cover depth, as increasing the train speed, the vibration speed of buried pipelines is also increased. The slope of vibration velocity is changed by attenuation of wave, at train speed, 300 km/h. From the analysis results, the vibration velocity of pipelines is satisfied with the vibration velocity criteria which are established by Korea Gas Corporation. The results present operation condition of pipelines under rail loads has fully sound integrity based on KOGAS specification.

  • PDF

감쇠진동계에 부착된 복합동흡진기의 효과에 관한 연구 (A Study on the Effects of Dual Dynamic Vibration Absorber for Damped Vibration System)

  • 안찬우;최석창;김동영
    • 소음진동
    • /
    • 제7권6호
    • /
    • pp.1039-1048
    • /
    • 1997
  • This paper describes the effects of dual dynamic vibration absorbers attached to a primary vibration system with damping. The efficiency of dual dynamic vibration absorbers was investigated with the height of amplitude ratio at the resonance frequency ratio of the damped vibration system according to mass ratio, natural frequency ratio and damping ratio. The variation of amplitude ratio related to frequency ratio of primary vibration system is verified experimentally and theoretically according to dual dynamic vibration systems using computer program designed to find mutual relationship between two absorbers.

  • PDF

고속 엘리베이터의 전후 진동제어를 위한 동적 모델링 및 능동 제어기 설계 (Dynamic Modeling and Controller Design for Active Control of High-speed Elevator Front-back Vibrations)

  • 백광현;김기영;곽문규
    • 한국소음진동공학회논문집
    • /
    • 제21권1호
    • /
    • pp.74-80
    • /
    • 2011
  • Front-back vibrations of high-speed elevator need to be suppressed as in the case of lateral vibrations. The dynamic model for the front-back vibrations is different from the lateral vibration model since the supporting structure varies. In this study, a dynamic model was derived using the energy method. Based on the free vibration analysis, it was observed that the fundamental frequency for the front-back vibration is slightly lower than the fundamental frequency of the lateral vibration, which means that the active vibration control should be carried out in both directions. The PPF control algorithm was applied to the numerical model under measured rail irregularities. The numerical results show that the active vibration control of elevator front-back vibration is also possible.

토크 측정을 이용한 차량 변속기용 비틀림 진동 절연 댐퍼 평가 (Evaluation of Torsional Vibration Isolation Damper in Automotive Transmissions Based on In-situ Torque Measurement)

  • 김기우;장재덕
    • 한국소음진동공학회논문집
    • /
    • 제22권4호
    • /
    • pp.377-382
    • /
    • 2012
  • This paper presents a proof-of-concept study on the evaluation of torsional vibration isolation performance through in-situ output torque measurement by using a non-contacting magneto-elastic torque transducer installed in the vehicle driveline system. The de-trending processing is first conducted to extract the torsional vibration from the measured driveline output torque. In order to estimate the transmissibility, primary performance indicator of a vibration isolator, the magnitude of transmitted torsional vibration with different frequencies is compared. From the conservative estimation results, the torsional damper built in a lock-up clutch of a torque converter is identified to be a vibration isolator. The evaluation results show that the fluid damping by torque converter outperforms the vibration isolation function of a torsional damper, and the isolation performance needs to be enhanced.

RC조 건축물의 구조시스템에 따른 수직진동 전달 특성 비교 (Characteristics of Vertical Vibration Transfer according to RC Structure Systems)

  • 전호민
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2006년도 추계학술대회논문집
    • /
    • pp.196-201
    • /
    • 2006
  • In general, the vertical vibration problems for strength of members and serviceability of building structures are not considered in structural design process, but the prediction of the vertical vibration is very important and essential to structural design process. This study aims to investigate the characteristics of vertical vibration in terms of the transfer of horizontal directions on the rahmen building structures and the shear wall building structures. In order to examine the characteristics of vertical vibration, the modal test and the heel-drop excitation experiments were conducted several times on the two type building structures. The results from the experiments are analyzed and compared with the results. The results of this study suggest that the characteristics of vortical vibration transfer in horizontal way are effected from the fundamental frequency of the slabs and excitation forces and are effected the shear wall on the path of the vibration transfer.

  • PDF

실험적 방법을 통한 전동식 지게차의 진동저감에 대한 연구 (The Study about Vibration Reduction of the Electronic Forklift on Experiment at Methods)

  • 정진태;박철준;임형빈;문창기
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2006년도 추계학술대회논문집
    • /
    • pp.577-581
    • /
    • 2006
  • In this study, it is presented a vibration cause of an electronic forklift by a variable excitation through experimental methods. It is presented a vibration influence by a variable excitation and established an FE model about structure vibration. It is used an FE model and presented parameters causing the vibration. It is presented a mechanism causing the vibration of the electronic forklift and proposed a vibration reduction of the electronic forklift.

  • PDF

고낙차 펌프-터빈에서의 축계 진동 특성 (Characteristics of the Shaft Vibration in a High Head Pump-Turbine)

  • 하현천;최성필
    • 유체기계공업학회:학술대회논문집
    • /
    • 유체기계공업학회 1998년도 유체기계 연구개발 발표회 논문집
    • /
    • pp.166-172
    • /
    • 1998
  • This paper describes the shaft vibration phenomena measured on a pump-turbine ofa pumped storage power plant. The pump-turbine runs at a rotational speed of 450 rpm (7.5 Hz). The power output (load) of the pump-turbine was varied from 100 to 300 MW in the generating mode. It was found that the magnitude of the shaft vibration was highly dependent upon the power load. The vibration magnitude of the shaft vibration is very high in the middle load zone from 170 to 210 MW, elsewhere the vibration low. From vibration spectra, it was found that the frequency of major vibration in that load zone was 2.5 Hz which is approximately $34\%$ of the shaft rotating speed in Hz. This frequency component disappeared below and above that load zone. This subsynchronous vibration is caused by the flow induced disturbance due to spiral vortex flow downstream of the pump-turbine runner. Furthermore, it was found that shaft vibration was highly decreased due to the increase of bearing preload.

  • PDF