• 제목/요약/키워드: vibrating device

검색결과 67건 처리시간 0.026초

중이 이식형 보청기에서 DFMT의 진동에 의한 등골 및 고막 방향으로 전달되는 진동력 측정 (Measurement of transmitted vibration to stapes and tympanic membrane by DFMT's vibration in implantable middle ear hearing devices)

  • 이명원;성기웅;임형규;김민우;정의성;이장우;김동욱;이정현;이상흔;이규엽;조진호
    • 센서학회지
    • /
    • 제18권4호
    • /
    • pp.286-293
    • /
    • 2009
  • The implantable middle ear hearing devices(IMEHDs) have been developed to overcome the conventional hearing aid's problem(ringing effect caused by the acoustic feedback, cosmetic problem, etc.). In the IMEHDs, the vibrating transducer is a key component because its vibration enables to hear for hearing impaired people. The vibrating transducer is implanted on ossicular chain by surgical operation. The coupling status between implanted transducer and ossicular chain has an effect on delivering vibrating force from transducer to stapes. Noninvasive method is required to investigate the output characteristics of IMEHDs after implementation. Recently, emitted sound pressure measuring method of tympanic membrane is proposed to investigate the output characteristics of IMEHDs. However, the relationship between displacement of stapes and sound pressure by tympanic membrane was not cleared. In this paper, displacement of stapes and sound pressure by tympanic membrane were measured using the differential floating mass transducer(DFMT) that implanted on the ossicular chain of the human temporal bone and physical ear model. Through the experiments results, the relationship between displacement of stapes and sound pressure by tympanic membrane was investigated.

압전구동기를 이용한 정밀 가공용 초음파 진동장치 설계 (Design of Ultrasonic Vibration Device using PZT Actuator for Precision Laser Machining)

  • 김우진;;조성학;박종권;이문구
    • 한국레이저가공학회지
    • /
    • 제14권2호
    • /
    • pp.8-12
    • /
    • 2011
  • As the aged population grows around the world, many medical instruments and devices have been developed recently. Among the devices, a drug delivery stent is a medical device which requires precision machining. Conventional drug delivery stent has problems of residual polymer and decoating because the drug is coated on the surface of stent with the polymer. If the drug is impregnated in micro hole array on the surface of the stent, the problem can be solved. Micro sized holes are generally fabricated by laser machining; however, the fabricated holes do not have an enough aspect ratio to contain the drug or a good surface finish to deliver it to blood vessel tissue. To overcome these problems, we propose a vibration-assisted machining mechanism with PZT (Piezoelectric Transducers) for the fabrication of micro sized holes. If the mechanism vibrates the eyepiece of the laser machining head, the laser spot on the workpiece will vibrate vertically because objective lens in the eyepiece shakes by the mechanism's vibration. According to the former researches, the vibrating frequency over 20kHz and amplitude over 500nm are preferable. The vibration mechanism has cylindrical guide, hollowed PZT and supports. In the cylinder, the eyepiece is mounted. The cylindrical guide has upper and low plates and side wall. The shape of plates and side wall are designed to have high resonating frequency and large amplitude of motion. The PZT also is selected to have high actuating force and high speed of motion. The support has symmetrical and rigid characteristics.

  • PDF

FEA를 이용한 이식형 인공중이용 차동전자 트랜스듀서의 진동 모델링과 최적 설계 (Vibration Modeling and Optimal Design of Differential Electromagnetic Transducer for Implantable Middle Ear Hearing Devices using the FEA)

  • 김민규;임형규;한찬호;송병섭;박일용;조진호
    • 한국음향학회지
    • /
    • 제24권7호
    • /
    • pp.379-386
    • /
    • 2005
  • 최근까지 개발되었던 청각 보조기 중에서 공기 전도형 보청기의 하울링 (howling) 현상과 수술 후 이소골 등 기존 음향계의 재생이 불가능한 인공 와우 (cochlear implant system)의 단점을 해결하고, 동시에 청음 명료도가 높은 음성 신호를 전달하기 위한 수단으로 연구된 것이 인공중이 (implantable middle ear hearing device) 이다. 본 연구에서는 인공중이의 음성 신호 재현을 위한 진동 장치인 차동전자 트랜스듀서 (differential electromagnetic transducer, DET)에 대한 수학적 모형화와 계의 진동을 기술하는 운동방정식을 유도하고 그 해를 구하였다. 제한된 크기와 인가 전류 $1\;mA_{rms}$ 정현파에서 최대 구동력을 얻기 위해서 전자기력에 대한 유한요소해석을 수행하였고, 결과에 의해서 자석과 코일에 대한 최적 크기를 결정하였다. 사람의 중이 내 등자뼈 (stapes)의 진동 특성과 유사한 진동을 갖는 DET를 설계하기 위해서, 진동막의 강성계수를 변화하면서 진동해석을 시뮬레이션 하였다. 설계된 DET는 마이크로 머시닝 기술에 의해서 제작하였고, 그 진동 특성을 측정 하였다. 최종적으로 측정된 진동 특성에 대한 분석을 통하여 인공중이를 위한 진동 장치로서의 적용 가능함을 확인하였다.

배터리 구동방식 정형외과용 핸드피스 개발에 대한 연구 (A study about development of hand-piece for orthopedic surgery drived by battery)

  • 손창우;장성희;장영주;서태일
    • Design & Manufacturing
    • /
    • 제9권1호
    • /
    • pp.31-35
    • /
    • 2015
  • Recently, life expectancy increased in the development of medicine, the need for health has increased. Market for medical equipment is growing rapidly to an increase in the interest in health and aging worldwide. It is a device intended for ultra sensitive cleavage process of bone during joint replacement surgery on a technical advanced surgery, finishing, and hole. Domestic demand of the hand piece is a necessary condition on an ongoing basis. However, hand piece was made on the basis of the experience of many years in the country Japan, Germany, and the United States has spread to more than 90% domestic market. Feel the need for the development of the hand piece in the country, many companies are trying to in-house production hand piece. In an attempt to solve the problems with the hand piece of the present, in this paper, it was supposed to be a study of rechargeable hand piece to replace the existing pneumatic.

  • PDF

중공사막에서의 물질전달 특성에 관한 연구 (A Study on the Characteristics of Mass Transfer in Hollow Fiber Membranes)

  • 김기범;김종석;김종수;유일수;이왕로;김성종
    • 멤브레인
    • /
    • 제14권2호
    • /
    • pp.142-148
    • /
    • 2004
  • 본 연구는 호흡부전환자를 위한 진동형 혈관 내 폐 보조장치를 사용하여 산소전달효율을 향상시키기 위한 연구이다. 유량은 점프와 유량을 사용하여 조정하였다. 가진 장치는 압전 진동자, 함수 발생기와 전력 증폭기로 구성하였다. 기체의 유량은 120 cm 길이의 중공사를 통하여 6 L/min까지 하였으며 압전 진동자로 가진 하였다. PVDF 센서와 FRF를 사용하여 VIVLAD에서 발생하는 주파수를 검출하였다. 실험결과, 최대 진폭이 발생하고 중공사들에 진동이 전달되어 최대 산소전달속도가 발생함을 확인할 수 있었다. 이 최대 진폭은 다양한 유속과 각각의 모듈에서 35 Hz 영역에서 발생함을 확인할 수 있었다.

초음파 진동을 이용한 취성재료 가공기술에 관한 연구 (A Study on Micro Ultrasonic machining for Brittle Material Using Ultrasonic vibration)

  • 이석우;최헌종;이봉구
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 1997년도 추계학술대회 논문집
    • /
    • pp.969-972
    • /
    • 1997
  • Ultrasonic machining technology has been developed over recent years for he manufacture of cost-effective and quality-assured precision parts for several industrial application such as optics, semiconductors, aerospace, and automobile application. The past decade has seen a tremendous in the use of ceramic in structural application. The excellent thermal, chemical and wear resistance of these material can be realized because of recent improvement in the overall strength and uniformity of advanced ceramics. Ultrasonic machining, in which abrasive particles in slurry with water are presented to the work surface in the presence of an ultrasonic-vibrating tool, is process which should be of considerable interest, as its potential is not limited by he electrical or chemical characteristics of the work material, making it suitable for application to ceramics. In order to improve the currently used ultrasonic machining using ultrasonic energy, technical accumulation is needed steadily through development of exciting device of ultrasonic machine composed of piezoelectric vibrator and horn. This paper intends to further the understanding of the basic mechanism of ultrasonic machining for brittle material and ultrasonic machining of ceramics based in the fracture-mechanic concept has been analyzed.

  • PDF

핵연료봉 프레팅마멸 시험기 개발 (Development of Fuel Rod Fretting Wear Tester)

  • 김형규;하재욱;윤경호;강흥석;송기남
    • 한국윤활학회:학술대회논문집
    • /
    • 한국윤활학회 2001년도 제34회 추계학술대회 개최
    • /
    • pp.245-251
    • /
    • 2001
  • A fretting wear tester is developed for experimental study on the fuel fretting problem of light water reactor. The feature of the developed tester is it can simulate the existence of gap between spring and fuel rod as well as different contacting force including the just-contact condition (0 N on the contact). Used are a servo-motor, an eccentric cylinder and lever mechanism for driving system. A spacer grid cell is constituted with four strap segments (each segment has a spring). This fretting wear tester can also be used as a fatigue tester of a spacer grid spring with the frequency of more than 10 Hz. It is required to simulate the frequency of the vibrating fuel rod due to flow-induced vibration in a reactor. In fretting wear test, up to two span-length of a fuel cladding tube can be accommodated. A specimen of cladding tube of one span-length is specially designed, which can be extended for two-span test. For .fatigue test, a device for clamping the spring fixture is installed additionally, Presently, the tester is designed for the condition of air environment and room temperature. The variation of the reciprocal distance is measured to check the stability of input force, which will be exerted to the cladding (for fretting wear. test) and the spring (for fatigue test) specimen.

  • PDF

질감 제시 장치를 이용한 촉감인지 특성 연구 (Study of Human Tactile Sensing Characteristics Using Tactile Display System)

  • 손승우;경기욱;양기훈;권동수
    • 제어로봇시스템학회논문지
    • /
    • 제11권5호
    • /
    • pp.451-456
    • /
    • 2005
  • This paper describes three kinds of experiments and analysis of their results related to human tactile sensitivity using an integrated tactile display system. The device can provide vibration, normal pressure and lateral slip/stretch which are important physical quantities to sense texture. We have tried to find out the efficient method of stimulating, limitation of surface discrimination by kinesthetic farce feedback and the effectiveness of the combination of kinesthetic force and tactile feedback. Seven kinds of different stimulating methods were carried out and they are single or combination of the kinesthetic force, normal static pressure, vibration, active/passive shear and moving wave. Both prototype specimen and stimulus using tactile display were provided to all examinees and they were allowed to answer the most similar sample. The experimental results show that static pressure is proper stimulus for the display of micro shape of the surface and vibrating stimulus is more effective for the display of fine surface. And the sensitivities of active touch and passive touch are compared. Since kinesthetic force feedback is appropriate to display shape and stiffness of an object, but roughness display has a limitation of resolution, the concurrent providing methods of kinesthetic and tactile feedback are applied to simulate physical properties during touching an object.

Multi Antenna GPS를 이용한 취약사면 상시모니터링 시스템 (The Monitoring System Using Multi Antenna GPS for Weak Slope)

  • 노원석;김완종;장현익;김학수
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2009년도 세계 도시지반공학 심포지엄
    • /
    • pp.677-694
    • /
    • 2009
  • While the budget has been allocated more for repairs and reinforcements, casualties are gradually increased due to slope disaster. Slope disaster causes road damaged as well as casualties. It also causes significant social and economic loss. The measurement device, which is installed inside ground of slope like inclinometer, has the high loss rate when slope is being slided. The electric type and the vibrating wire type have low durability because of corrosion. To cover the demerit of the present slope monitoring, the measurement method using the Multi-Antenna GPS has been developed. The Multi-Antenna GPS has been installed in the local slope as the regular monitoring system for slope. Although the initial cost of the Multi-Antenna GPS for installation is high, the additional cost is low. So it is the suitable method for large slope. The regular monitoring system using the Multi-Antenna GPS is the suitable measurement method for watching slope collapse, which is occurred widely, because it is economical, has high durability, and collects data with high resolution.

  • PDF

이식형 중이용 청각보조 트랜스듀서의 설계 (Design of Implantable Transducer for Middle Ear Hearing Aid)

  • 박형욱;송병섭;원철호;박세광;이상흔;조진호
    • 대한의용생체공학회:학술대회논문집
    • /
    • 대한의용생체공학회 1996년도 춘계학술대회
    • /
    • pp.243-247
    • /
    • 1996
  • Electro-magnetic type implantable middle ear hearing aid has been empirically developed. But for further improvement of the system performance more quantitative approach is necessary. In this paper, we analyzed vibrating transducer which is most important to design the system, appropriate for given hearing level, and implemented it. Using this transducer, implantable hearing aid system are developed. To verify the design process, we experimented with driving metal strip by the developed system. From the experiment, frequency response of implemented device showed good characteristic at audio frequency and we confirmed that each part of the developed system operated well.

  • PDF