• Title/Summary/Keyword: vertical testing

Search Result 333, Processing Time 0.021 seconds

Across-wind dynamic loads on L-shaped tall buildings

  • Li, Yi;Li, Qiu-Sheng
    • Wind and Structures
    • /
    • v.23 no.5
    • /
    • pp.385-403
    • /
    • 2016
  • The across-wind dynamic loads on L-shaped tall buildings with various geometric dimensions were investigated through a series of wind tunnel testing. The lift coefficients, power spectral densities and vertical correlation coefficients of the across-wind loads were analyzed and discussed in details. Taking the side ratio and terrain category as key variables, empirical formulas for estimating the across-wind dynamic loads on L-shaped tall buildings were proposed on the basis of the wind tunnel testing results. Comparisons between the predictions by the empirical formulas and the wind tunnel test results were made to verify the accuracy and applicability of the proposed formulas. Moreover, a simplified procedure to evaluate the across-wind dynamic loads on L-shaped tall buildings was derived from the proposed formulas. This study aims to provide a simple and reliable way for the estimation of across-wind dynamic loads on L-shaped tall buildings.

Research on non-destructive testing technology for existing bridge pile foundations

  • Zhang, Xue-feng;Ni, Ying-sheng;Song, Chunxia;Xu, Dong
    • Structural Monitoring and Maintenance
    • /
    • v.7 no.1
    • /
    • pp.43-58
    • /
    • 2020
  • Pile foundations of existing bridges lie in soil and water environment for long term and endure relatively heavy vertical loads, thus prone to damages, especially after stricken by external forces, such as earthquake, collision, soil heap load and etc., and the piles may be injured to certain degrees as well. There is a relatively complete technical system for quality inspection of new bridge pile foundations without structures on the top. However, there is no mature technical standard in the engineering community for the non-destructive testing technology specific to the existing bridge pile foundations. The quality of bridge pile foundations has always been a major problem that plagues bridge maintenance. On the basis of many years' experiences in test engineering and theoretical studies, this study developed a new type of detection technology and equipment for the existing bridge piles.

On Study the Safety Diagnosis of Carbody Structure for Crashed Electric Multiple Units (사고전동차 구조체의 안전진단에 관한 고찰)

  • Bae Dae-Sung;Park Geun-Soo;Chung Jong-Duk
    • Journal of the Korean Society for Railway
    • /
    • v.8 no.3
    • /
    • pp.253-259
    • /
    • 2005
  • This paper describes 3D Dimensional Measurement(EDM testing) and tensile testing results of carbody structure for crashed EMU(Electric Multiple Units). Tensile tests were performed on two different types of specimens in order to evaluate the strength changes before and after damages, obtained from plastic deformed area and nondeformed region of the crashed EMU. And Structural analysis of EMU was performed for the criteria of safety assessment. Structural analysis using commercial I-DEAS software provided important information on the stress distribution and load transfer mechanisms as well as the amount of damages during rolling stock crash. The testing results have been used to provide the critical information for the criteria of safety diagnosis.

An Evaluation of Structural Strength by Testing the Carbody of Light Composite Material (경량 복합소재 차체의 시험에 의한 구조강도 평가)

  • Yoon S.C.;Jeon C.S.;Kim W.K.;Kim M.Y.
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2006.05a
    • /
    • pp.393-394
    • /
    • 2006
  • This study introduces the testing results of the composite carbody which is applied to tilting train. The composite carbody is made of aluminum honeycomb structure materials like a sandwich. The static load test was performed to evaluate the structural characteristic and stability of the composite carbody. Considering the vertical, compressive, twisting load and 3-point supporting type as a testing terms, the structural stability of a carbody was evaluated.

  • PDF

An Experimental Study on the Impact Collapse Characteristics of CFRP Composite Circular Structures (탄소섬유강화 복합재료 원통부재의 충격압궤특성에 관한 실험적 연구)

  • 김영남;양현수
    • Journal of the Korea Safety Management & Science
    • /
    • v.3 no.1
    • /
    • pp.127-137
    • /
    • 2001
  • Because of the inherent flexibility in their design for improved material properties, composites have wide applications in aerospace vehicles and automobiles. The purpose of this study is to investigate the energy absorption characteristics of CFRf (Carbon Fiber Reinforced Plastics) tubes on static and impact tests. Static compression tests have been carried out using the static testing machine(Shin-gang buckling testing machine) and impact compression tests have been carried out using the vertical crushing testing machine. When such tubes were subjected to crushing loads, the response is complex and depends on the interaction between the different mechanisms that control the crushing process. The collapse characteristics and energy absorption were examined. Trigger and interlaminar number affect the energy absorption capability of CFRP tubes.

  • PDF

Power performance Testing of Small Wind Turbine Generator System (소형 풍력발전시스템의 출력성능검사)

  • Kim, Hyeon-Ki;Kim, Byeong-Min;Yoo, Neung-Soo
    • Journal of Industrial Technology
    • /
    • v.31 no.A
    • /
    • pp.123-128
    • /
    • 2011
  • In this study, procedures, a power performance testing system of Wind Turbine System Research Center of Kangwon National University is introduced. Test prodedures and results are presented on a stand-alone vertical-axis 200W wind turbine manufactured by Geum-Poong Energy Inc.. Power performance test is performed according to IEC standard. The test results are compared with the power performance standard. Also, the effects of normalization and disturbed sectors are considered.

  • PDF

Critical evaluation of fracture strength testing for endodontically treated teeth: a finite element analysis study

  • Uzunoglu-Ozyurek, Emel;Eren, Selen Kucukkaya;Eraslan, Oguz;Belli, Sema
    • Restorative Dentistry and Endodontics
    • /
    • v.44 no.2
    • /
    • pp.15.1-15.8
    • /
    • 2019
  • Objectives: The aim of this study was to investigate whether the diameter and direction of the plunger and simulation of the periodontal ligament (PDL) affected the stress distribution in endodontically treated premolars. Methods: A fracture strength test was simulated via finite element analysis. A base model was set up, and the following parameters were modified: plunger diameter (3 mm vs. 6 mm), plunger direction (vertical vs. $135^{\circ}$ angular to the central fossa), and PDL simulation. The analysis was conducted using the CosmosWorks structural analysis program, and the results are presented in terms of von Mises stresses. Results: The smaller plunger increased the stresses at the contact area of the crown, but the plunger diameter had no effect on the stress distribution within the root. An angular plunger direction increased stresses within the root, as well as at the buccal cusp of the crown, compared with the vertical direction. Simulation of the PDL caused higher stress accumulation, especially in the cervical region of the root. Conclusions: The plunger diameter had no effect on the stress distribution in the roots, whereas the plunger direction and PDL simulation did affect the stress distribution. More stringent standards can be established by taking such parameters into account when performing fracture testing in future studies.

The Characteristics of Consolidation and Permeability in Normally Consolidated Region Using a Remolded Decomposed Mudstone Soil (재성형된 이암풍화토를 이용한 정규압밀영역의 압밀 및 투수특성)

  • 김영수;김기영;이상웅
    • Journal of the Korean Geotechnical Society
    • /
    • v.16 no.2
    • /
    • pp.61-70
    • /
    • 2000
  • When clay foundations of embankments are treated with vertical drain, essentially, the strain occurs to vertical direction but the water flow is radial. The initial horizontal permeability and its variation with the vertical compression are key parameters for the choice of the type of drains, their spacing, and affect to the cost of the project. In this study, CRS consolidation test is performed to investigate the anisotropic characteristics of decomposed mudstone soil and direct permeability test is performed on the same specimens. The results of testing show that Ch is larger than Cv. specially, the Cv - $\sigma$v relationship for a soil sample is viewed from three different curve segments corresponding to overconsolidated, transition and normally consolidated states. The anisotropic ratio, rk(kh/kv) is 2.19. Coefficient of permeability in normally consolidated state is related to its void ratio and permeability parameter n. C can be determined from a linear plot of log[k(1+e)] versus log e. The slope, n, of graphs is the same, whereas the vertical intercept, log C, seems to vary somewhat for anisotropic.

  • PDF

Real-scale field testing for the applicability examination of an improved modular underground arch culvert with vertical walls

  • Tae-Yun Kwon;Jin-Hee Ahn;Hong-duk Moon;Kwang-Il Cho;Jungwon Huh
    • Advances in concrete construction
    • /
    • v.15 no.6
    • /
    • pp.377-389
    • /
    • 2023
  • In this study, an improved modular arch system with the lower arch space composed of a precast arch block and an outrigger was proposed as an underground culvert, and its applicability and structural behaviors were confirmed. This modular arch culvert structure with vertical walls was designed using precast blocks and by adjusting the placement spacing of concrete blocks to the upper part form an arch shape and the lower part form a vertical wall shape, based on previously researched modular arch systems. Owing to the vertical wall of the proposed modular arch system, it is possible to secure a load-carrying capacity and an arch space that can sufficiently resist the earth pressure generated from the backfill soil and loading on the arch system. To verify the structural characteristics, and applicability of the proposed modular precast arch culvert structure, a full-scale modular culvert specimen was fabricated, and a loading test was conducted. By examining its construction process and loading test results, the applicability and constructability of the proposed structure were analyzed along with its structural characteristics. In addition, its the structural predictability and safety for the applicability were evaluated by comparing the construction process and loading test results with the FE analysis results.

Conformity Assessment of Vertical Static Stiffness Test Method for Rail Pad (레일패드 정적 수직강성 시험방법의 적합성 평가)

  • Bae, Young-Hoon;Kim, Man-Cheol
    • Journal of the Korean Society for Railway
    • /
    • v.18 no.1
    • /
    • pp.33-42
    • /
    • 2015
  • The vertical static stiffness of rail pads or baseplate pads, which are important components in rail fastening systems for track safety, is a key factor to determine the total track stiffness and a guideline of quality control in the manufacturing process. The vertical static stiffness can be checked by laboratory testing: test methods are EN 13146-9 and KRS TR 0014, which are widely used in the railway field. In this paper, to correct some problems, namely the preloading step, the unloading level, and the holding time in the loading program in the vertical static stiffness test of EN 13146-9 and KRS TR 0014, domestic and foreign test standards of pads were analyzed and then certain schemes for a vertical static stiffness test were proposed. To assess the reliability of the proposed schemes, the vertical static stiffness tests were performed with 4 pads and the validity of the test results was estimated.