• 제목/요약/키워드: vertical structure

검색결과 2,451건 처리시간 0.041초

Vertical Shortening Considerations in the 1 km Tall Jeddah Tower

  • Peronto, John;Sinn, Robert;Huizinga, Matthew
    • 국제초고층학회논문집
    • /
    • 제6권1호
    • /
    • pp.21-31
    • /
    • 2017
  • Jeddah Tower will be the first man-made structure to reach a kilometer in height upon its completion in 2019. From conception, it was clear that an all-concrete superstructure would present many advantages for a building of such unprecedented height and slenderness. An all-concrete structure, however, did present many challenges that needed to be addressed in the system arrangement and through comprehensive analysis and design, among them vertical shortening effects due to the time-dependent creep and shrinkage of concrete. This paper outlines and presents the engineering solutions developed by the authors regarding this complex concrete material phenomenon, while addressing the construction and regional challenges associated with realizing a concrete tower of this unprecedented scale.

Optimized electrode design to improve transmittance in the Patterned Vertical Alignment Liquid Crystal Display

  • Hwang, Seong-Jin;Kim, Youn-Sik;Lee, Seung-Hee;Lyu, Jae-Jin;Kim, Kyeong-Hyeon
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 한국정보디스플레이학회 2007년도 7th International Meeting on Information Display 제7권1호
    • /
    • pp.549-552
    • /
    • 2007
  • Patterned vertical alignment (PVA) mode requires multi-domain to exhibit wide viewing angle whereas the transmittance is sacrificed. To overcome the demerit, a fine pattern was formed at folded region in PVA Z-shape electrode structure. In the present work fine patterns were formed near domain boundary regions where the unwanted field direction which causes the LC to tilt down in unwanted direction exists. Thereby transmittance is improved near those fine patterns. This method is very simple and more cost-effective process than the other methods. In this article, we show the method of fine pattern formation and its influence on LC molecule in PVA mode with Z-shape electrode structure.

  • PDF

박물관 대공간의 공간구조 형식과 특성에 관한 연구 (A Study on the Type and Characteristics of the Spatial Structure in Major Space of Museums)

  • 박세민;정성욱
    • 한국실내디자인학회논문집
    • /
    • 제17권6호
    • /
    • pp.178-187
    • /
    • 2008
  • This study aims to analyze general features and forms of spatial structure of major space in museums and for the scope of this study, set up major space and the surrounding areas structured around major space and for the target of analysis, selected 10 museums of overseas examples from 19th century to 2006. And this study on focus, on the circulation structure and visual structure will be analyzed in qualitative method by focusing on the floor plan and section structures; deepening process of analysis, visual structure will turn into numerical value to analyze the spatial structure of the major space. The results of this study are as follow. First, vertical elements should be critically considered in a circulation plan for functional performance of dimensional circulation distribution in a major space. Second, a plan by location of vertical and horizontal moving elements related to a major space affects a circulation relation more than a connection type between a major space and an exhibition area. Third, it could be categorized into 4 types by considering the features of spatial structure followed by connecting relationship between areas. Fourth, comparable figures were drawn out among large space and surrounding areas but it couldn't draw out types.

LCD 에서 해상도와 Display Quality 의 상관관계 (A Function of Resolution and Display Quality in LCD)

  • 최승규;강인병;송영철
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 2003년도 신호처리소사이어티 추계학술대회 논문집
    • /
    • pp.343-346
    • /
    • 2003
  • In this paper, we try to make a systematic analysis for the vertical crosstalk on LCD driving. The vertical Crosstalk is one of the inevitable phenomena in the high-resolution TFT-LCDs. At first, the vortical Crosstalk is defined. Considering the structure of the pixels and data lines, a LCD (a pixel) is modeled electrically by its' equivalent circuit. The circuit is verified by experiment and used to find the cause of the vertical Crosstalk.

  • PDF

Submerged Membrane Breakwaters I: A Rahmen Type System Composed of Horizontal and Vertical Membranes

  • Kee, Sung-Tae
    • International Journal of Ocean Engineering and Technology Speciallssue:Selected Papers
    • /
    • 제5권1호
    • /
    • pp.14-21
    • /
    • 2002
  • In the present paper, the hydrodynamic properties of a Rahmen-type, flexible, porous breakwater interacting with obliquely or normal- incident small amplitude waves are numerically investigated. This system is composed of dual vertical porous membranes, hinged at the side edges of a submerged horizontal membrane. The dual vertical membranes are extended downward and hinged at seabed. The effects of permeability, Rahmen-type membrane breakwater geometry, pre-tensions on membranes, relative dimensionless wave number, and incident wave headings are thoroughly examined.

  • PDF

Flow separator가 부착된 수직벽 후류유동의 실험적 연구 (Experimental study of vertical fence wake with flow separator)

  • 최영호;김형범
    • 한국가시화정보학회:학술대회논문집
    • /
    • 한국가시화정보학회 2006년도 추계학술대회 논문집
    • /
    • pp.68-72
    • /
    • 2006
  • Vertical fence has the coherent flow structure in front of the fence. In the present study, the wake change due to the flow separator in front of the vertical fence was experimentally investigated. Quantitative method was applied to study the separated shear flow field. The results show the flow separator changes the downstream shear flow and alters the curvature of separated shear layer As the freestream velocity increased, the reattachment length also increased.

  • PDF

유체와 구조물이 조합된 대형 수직펌프의 동특성 개선 (Modal Analysis In The Dynamic Behavior Identification of the fluid-structure coupled Vertical Pump)

  • 배춘희;조철환;김성휘;박영필
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2001년도 추계학술대회논문집 II
    • /
    • pp.622-627
    • /
    • 2001
  • The paper presents the possibilities of a wide practical application of the modal analysis methods in dynamic testing of vertical pump. A pneumatic impact of testing vertical pumps submerged under deep water was developed and successfully applied. The problem with the enviroment is the it causes significants changes in modal parameters, compared with those in the airenviroment.

  • PDF

Directional Orbital Angular Momentum Generator with Enhanced Vertical Emission Efficiency

  • Tran, Thang Q.;Kim, Sangin
    • Current Optics and Photonics
    • /
    • 제3권4호
    • /
    • pp.292-297
    • /
    • 2019
  • We propose a ring resonator-based orbital angular momentum carrying vortex beam generator design with high vertical directional emission efficiency. By adopting a vertically asymmetric grating structure in the ring resonator, optimized for enhanced vertical emission, an emission efficiency in one direction reaches as high as 78%, exceeding the 50% theoretical limit of previously designed vertically symmetric grating-assisted ring resonator-based structures.

납-고무면진장치가 적용된 트러스-아치 구조물의 지진거동 분서 (The Seismic Behavior of the Truss-Arch Structure with Lead Rubber Bearing(LRB))

  • 신민기;김기철;강주원
    • 한국공간구조학회:학술대회논문집
    • /
    • 한국공간구조학회 2008년도 춘계 학술발표회 논문집
    • /
    • pp.133-138
    • /
    • 2008
  • 본 연구에서는 대공간구조물의 기본적인 동적특성을 가지고 있으며 동시에 가장 간단한 구조이기도 한 아치에 납-고무면진 장치를 적용하여 지진거동을 분석하였다. 대공간구조물의 지진거동은 일반적인 골조구조물의 지진거동과 달리 수평지진에 의하여 수직방향으로 큰 지진응답이 나타나고 있다. 면진장치를 대공간 구조물에 적용할 경우에 수평지진하중에 의하여 수평방향 지진응답이 저감되는 것은 물론 면진장치의 수직강성으로 인하여 수직응답도 현저하게 저감되는 것을 알 수 있었다.

  • PDF

면진장치 설치각도에 따른 아치구조물의 지진응답 (Seismic Response of Arch Structure with Base Isolation Device Depending on Installation Angle)

  • 김기철;이준호
    • 한국공간구조학회논문집
    • /
    • 제22권1호
    • /
    • pp.25-32
    • /
    • 2022
  • The seismic behaviors of the arch structure vary according to the rise-span ratio of the arch structure. In this study, the rise-span ratio (H/L) of the example arch structure was set to 1/4, 1/6, and 1/8. And the installation angle of the seismic isolator was set to 15°, 30°, 45°, 60° and 90°. The installation angles of the seismic isolator were set by analyzing the horizontal and vertical reaction forces according to the rise-span ratio of the arch structure. Due to the geometrical and dynamic characteristics of the arch structure, the lower the rise-span ratio, the greater the horizontal reaction force of the static load, but the smaller the horizontal reaction force of the dynamic load. And if the seismic isolator is installed in the direction of the resultant force of the reaction forces caused by the seismic load, the horizontal seismic response becomes small. Also, as the installation angle of the seismic isolator increases, the hysteresis behavior of the seismic isolator shows a plastic behavior, and residual deformation appears even after the seismic load is removed. In the design of seismic isolators for seismic response control of large space structures such as arch structures, horizontal and vertical reaction forces should be considered.