• Title/Summary/Keyword: vertical shear

Search Result 931, Processing Time 0.026 seconds

Development of a Measuring Method for Dynamic Contact Forces between a Pantograph and a Contact Wire (열차 집전장치와 전차선 사이의 동적 접촉력 측정방법 개발)

  • 조용현;최강윤
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2002.05a
    • /
    • pp.281-285
    • /
    • 2002
  • A new method of dynamic contact force measurement between a pantograph and a contact wire is proposed in this paper The method does not require design modification of an original pantograph in order to install sensors such as load cells. Contact forces can be expressed as the sum of vertical shear forces at the support points and inertial forces. Using specially-designed strain gage rosettes. vertical shear forces at the supported points can be measured without noise mixing and thermal effects. In order to obtain contact forces from shear forces, 3 inertial force compansation methods are proposed and compared in this paper. By validation process, the new proposed measurement method is verified to be applicable to the on-line current collection test.

  • PDF

Vertical Vorticity Structure Associated with the Boreal Summer Intraseasonal Oscillation: Barotropic or Baroclinic? (여름철 계절내 진동에 의한 대기 와도의 연직 구조: 순압성 또는 경압성?)

  • Song, Eun-Ji;Seo, Kyong-Hwan
    • Atmosphere
    • /
    • v.22 no.2
    • /
    • pp.259-265
    • /
    • 2012
  • This study investigates the reason why the barotropic vorticity structure prevails vertically in response to the enhanced convection associated with the boreal summer intraseasonal oscillation over the central Indian Ocean. The relative vorticity tendency analysis for a 2.5-layer simplified model demonstrates that the barotopic vorticity structure is predominant due to the following two factors: 1) vertical easterly shear on the meridional gradient of barotropic divergence (which induces generation of barotropic vorticity twice larger than that of baroclinic vorticity); and 2) vertical easterly shear on the meridional gradient of baroclinic divergence (which appears only in relation to the generation of barotropic vorticity). The percentage of contribution by each term to barotropic and baroclinic vorticity tendency equations is presented.

Stress Analysis of Precast Concrete Large Panel Structures Taking Account of Stiffness of Vertical Joints (수직접합부 강성을 고려한 프리캐스트 콘크리트 대형판구조물의 응력해석)

  • 장극관;이한선;신영식;류진호
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 1993.10a
    • /
    • pp.149-156
    • /
    • 1993
  • Precast concrete (P.C.) large panel structures have usually weaker stiffness at joints than that of monolithic in-situ reinforced concrete structures. But structural designers do not in general take into account this characteristics of P. C. large panel structures and use the same analytical models as for the monolithic structure. Therefore, the results of analysis obtained by using these models may be quite different from those actually occuring in real P.C. structure. In this study, the change in force and stress distribution and deflections of structure caused by applying lower shear stiffness at vertical joints are investigated through trying several finite element modeling schemes specific for P.C. structures. Finally, for engineers in practice. a simplified model, which takes account of the effect of lower shear stiffness at vertical joints, is proposed with the understanding on possible amount of errors.

  • PDF

An Experimental Study on the Shear behavior of High Strength light-aggregate Reinforced Concrete Beam (고강도 경량 콘크리트 보의 전단거동에 관한 실험적 연구)

  • 박완신;진인철;윤현도;정수영
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 1999.10a
    • /
    • pp.385-388
    • /
    • 1999
  • This study is to investigate experimentally the shear capacity of high-strength reinforced concrete beams subjected to monotonic loading. Nine reinforced concrete beams using high strength concrete $(f'c=380kg/\textrm{cm}^2)$ are tested to determine their diagonal cracking and ultimate shear capacity. The main variables are shear span-depth ratio a/d=1.5, 2.5, 3.5, and shear reinforcement ratio. All specimens are 170mm wide and have a total depth of 300mm. The test results indicate that ACI 318-95(b) Code for shear capacity gave closest agrement with the exsprimental results. The beams with a shear spear-depth ratio 1.5 and 2.5. ACI 318-95 Code underestimates shear strength carried by vertical shear reinforcements.

A Study on Factors Influencing the Shear Strength of Shear Connectors (전단연결재 강도산정 영향인자에 대한 연구)

  • 여진호;임남형;강영종
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2001.11a
    • /
    • pp.1091-1096
    • /
    • 2001
  • Generally, in a steel girder and the concrete slab act as a composite structure, the connectors must have adequate strength and stiffness. If there are no horizontal or vertical separations at the interface, the connectors are described as rigid, and complete interaction can be said to exist under these idealized circumstances. In previous study, it was considered that the strength of stud is affected by the stud diameter, height of stud and compressive strength of concrete. The differences between previous study and this study are variables, which are shank diameter of shear connector, the spacing of shear connector, the size of specimen and the row of shear connector. So this paper, as a study on the strength of shear connector with the spacing of shear connector, size of specimen (block-out size), row of shear connector and shank diameter of shear connector resulted from the push-out specimen are conducted with ABAQUS program. It is to investigate the effects of characteristics of these factors. The load-slip relations obtained from the experiments are compared with those of analyses. From these results, the trends of stress are stress estimated and compared with push-out test.

  • PDF

Shear bond failure in composite slabs - a detailed experimental study

  • Chen, Shiming;Shi, Xiaoyu;Qiu, Zihao
    • Steel and Composite Structures
    • /
    • v.11 no.3
    • /
    • pp.233-250
    • /
    • 2011
  • An experimental study has been carried out to reveal the shear-bond failure mechanism of composite deck slabs. Thirteen full scale simply supported composite slabs are studied experimentally, with the influence parameters like span length, slab depth, shear span length and end anchorage provided by steel headed studs. A dozen of strain gauges and LVDTs are monitored to capture the strain distribution and variation of the composite slabs. Before the onset of shear-bond slip, the longitudinal shear forces along the span are deduced and found to be proportional to the vertical shear force in terms of the shear-bond strength in the m-k method. The test results are appraised using the current design procedures. Based on the partial shear-bond connection at the ultimate state, an improved method is proposed by introducing two reduction factors to assess the moment resistance of a composite deck slab. The new method has been validated and the results predicted by the revised method agree well with the test results.

Elastic solutions for shallow tunnels excavated under non-axisymmetric displacement boundary conditions on a vertical surface

  • Wang, Ling;Zou, Jin-Feng;Yang, Tao;Wang, Feng
    • Geomechanics and Engineering
    • /
    • v.19 no.3
    • /
    • pp.201-215
    • /
    • 2019
  • A new approach of analyzing the displacements and stress of the surrounding rock for shallow tunnels excavated under non-axisymmetric displacement boundary conditions on a vertical surface is investigated in this study. In the proposed approach, by using a virtual image technique, the shear stress of the vertical ground surface is revised to be zero, and elastic solutions of the surrounding rock are obtained before stress revision. To revise the vertical normal stress and shear stress of horizontal ground surface generated by the combined action of the actual and image sinks, the harmonic functions and corresponding stress function solutions were adopted. Based on the Boussinesq's solutions and integral method, the horizontal normal stress of the vertical ground surface is revised to be zero. Based on the linear superposition principle, the final solution of the displacements and stress were proposed by superimposing the solutions obtained by the virtual image technique and the stress revision on the horizontal and vertical ground surfaces. Furthermore, the ground settlements and lateral displacements of the horizontal and vertical ground surfaces are derived by the proposed approach. The proposed approach was well verified by comparing with the numerical method. The discussion based on the proposed approach in the manuscript shows that smaller horizontal ground settlements will be induced by lower tunnel buried depths and smaller limb distances. The proposed approach for the displacement and stress of the surrounding rocks can provide some practical information about the surrounding rock stability analysis of shallow tunnels excavated under non-axisymmetric displacement boundary conditions on a vertical surface.

Shear-Friction Truss Model for Reinforced Concrete Beams (철근콘크리트 보의 전단마찰모델)

  • 홍성걸;하태훈
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2001.11a
    • /
    • pp.873-878
    • /
    • 2001
  • This Paper Presents a new model, called the “shear-friction truss model,” for slender reinforced concrete beams to derive a clear and simple equation for their ultimate shear strength. In this model, a portion of the shear strength is provided by shear reinforcement as in the traditional truss model, and the remainder by the shear-friction mechanism. Friction resistance is derived considering both geometrical configuration of the rough crack surface and material Properties. The inclined angle of diagonal strut in the traditional truss model is modified to satisfy the state of balanced failure, when both stirrups and longitudinal reinforcement yield simultaneously. The vertical component of friction resistance is added to the modified truss model to form the shear-friction truss model. Test results from published literatures are used to find the effective coefficient of concrete strength in resisting shear on inclined crack surfaces.

  • PDF

Analytical simulation of reversed cyclic lateral behaviors of an RC shear wall sub-assemblage

  • Lee, Han Seon;Jeong, Da Hun;Hwang, Kyung Ran
    • Computers and Concrete
    • /
    • v.10 no.2
    • /
    • pp.173-196
    • /
    • 2012
  • Experimental results of cyclic reversed lateral force test on a two-story reinforced concrete shear wall sub-assemblage are simulated analytically by using the PERFORM-3D program. A comparison of experimental and analytical results leads to the following conclusions: (1) "Shear Wall" and "General Wall" models with "Concrete shear" cannot simulate the pinching phenomena due to shear and show larger amounts of inelastic energy absorption than those in the experiment. (2) Modeling a story-height wall by using two or more "General Wall" elements with "Diagonal shear" in the vertical direction induces the phenomenon of swelling-out at the belly, leading to the erroneous simulation of shear behaviors. In application to tall building structures, it is recommended to use one element of "General Wall" with "Diagonal shear" for the full height of a story. (3) In the plastic hinge area, concrete deformations of analytical models overestimate elongation and underestimate shortening when compared with experimental results.

Structural Performance Evaluation of Reinforced Concrete Shear Walls with Various Connection Type Under Load Reversals. (반복하중을 받는 철근콘크리트 전단벽체의 접합방식에 따른 구조성능 평가)

  • 신종학;하기주;권중배;전찬목
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 1997.10a
    • /
    • pp.513-518
    • /
    • 1997
  • In this study, nine reinforced concrete infilled frames involved bare frames were tested during vertical and cyclic loads simultaneously. This test programs were carried to investigate the horizontal strength and the crack propagation in variance with hoop reinforcement ratio. All specimens were modeling in one-third scale size. In this experimental program structural performance of reinforced concrete shear wall were focus at connection types. Based on the test results, the following conclusions are made. In the boundary column member of reinforced concrete shear wall, increasing the ratio of hoop bar in two or three times, in the fully babel type, the shear and horizontal strength of specimens were increased 1.1-1.2 times than that of fully rigid frame. And infilled shear wall specimen were increased 1.17-1.27 times than that. Fully rigid babel type shear wall specimens were increased 5.7~8.0 times, and infilled shear wall specimens were increased about 4.0~5.6 times than that of infilled shear wall specimens.

  • PDF